N447US
reservations
service difficulty reports
44 reports
- 12 Sep 2006
Frame, cracked
CRACK AT FRAME STA 616 RBL 64 JUST BELOW FLOOR LEVEL. REPAIRED IAW SB 737-53-1182 FIG 9.
- 8 Sep 2006
Stringer Clip, cracked
TIE CLIP CRACKED AT STA 344 STR 12R. REMOVED AND REPLACED TIE CLIP IAW SRM 51-10-02.
- 6 Sep 2006
Stringer Splice, cracked
STRINGER SPLICE CRACKED AT STA 907 STR 4L. REPLACED STRINGER SPLICE IAW 51-40-02.
- 5 Sep 2006
Stringer Clip, cracked
STRINGER TIE CRACKED AT STA 500G STR 8R. REPLACED TIE CLIP IAW SRM 51-40-02.
- 5 Sep 2006
Stringer Clip, cracked
STRINGER TIE CRACKED AT STA 907 STR 7R. REPLACED TIE CLIP IAW SRM 51-10-02.
- 5 Sep 2006
Stringer Clip, cracked
STRINGER TIE CLIP CRACKED AT STA 706 STR 11R. REPLACED TIE CLIP IAW SRM 51-10-02.
- 5 Sep 2006
Stringer Clip, cracked
STRINGER TIE CLIP CRACKED AT STA 706 STR 11L. REPLACED STRINGER TIE CLIP IAW SRM 51-10-02.
- 1 Sep 2006
Stringer Clip, cracked
STRINGER TIE CRACKED AT STA 420 STR 4R. REPLACED TIE CLIP IAW SRM 51-40-02.
- 1 Sep 2006
Frame, cracked
FRAME CRACKED AT STA 787 BETWEEN STR 8&9 R. REPAIRED PER SRM 51-70-11.
- 1 Sep 2006
Stringer Splice, cracked
STRINGER SPLICE CRACKED AT STA 727 STR 2L. REPLACED STRINGER SPLICE IAW SRM 51-40-02.
- 31 Aug 2006
Stringer Clip, cracked
STRINGER TIE CRACKED AT STA 500F STR 8R. REPLACED STRINGER TIE IAW SRM 51-10-02.
- 31 Aug 2006
Stringer Clip, cracked
STRINGER TIE CRACKED AT STA 500E. REPLACED STR TIE IAW SRM 51-10-02.
- 31 Aug 2006
Frame, cracked
FRAME CRACKED AT STA 907 BETWEEN STR 8&9L. REPAIRED PER SRM 51-70-11.
- 30 Aug 2006
Stringer Clip, cracked
STRINGER TIE CRACKED AT STA 727A S-8L. REMOVED AND REPLACED PER SRM 51-10-02.
- 30 Aug 2006
Stringer Clip, cracked
STRINGER TIE CRACKED AT STA 727C S4L. REMOVED AND REPLACED PER SRM 51-10-02.
- 30 Aug 2006
Stringer Clip, cracked
STRINGER TIE CLIP CRACKED AT STA 727A STR 2L. REMOVED AND REPLACED PER SRM 51-10-02.
- 30 Aug 2006
Stringer Clip, cracked
STRINGER TIE CLIP AT STA 277 STR 12R CRACKED. REMOVED AND REPLACED PER SRM 51-40-01.
- 30 Aug 2006
Stringer Clip, cracked
STRINGER TIE CRACKED AT STA 807 STR 4L. REMOVED AND REPLACED PER SRM 51-10-02.
- 30 Aug 2006
Stringer Clip, cracked
STRINGER TIE CRACKED AT STA 807 STR 4L. REPLACED STRINGER TIE IAW SRM 51-10-02.
- 30 Aug 2006
Stringer Clip, cracked
STRINGER TIE CRACKED AT STA 727A STR 2L. REPLACED STRINGER TIE IAW SRM 51-10-02.
- 30 Aug 2006
Stringer Clip, cracked
STRINGER TIE CRACKED AT STA 727A STR 8L. REPLACED STRINGER TIE IAW SRM 51-10-02.
- 30 Aug 2006
Stringer Clip, cracked
STRINGER TIE CRACKED AT STA 277 STR 12R. REPLACED STRINGER TIE IAW SRM 51-40-01.
- 30 Aug 2006
Stringer Clip, cracked
STRINGER TIE CRACKED AT STA 727C STR 4L. REPLACED STRINGER TIE IAW SRM 51-40-02.
- 30 Aug 2006
Stringer Clip, cracked
STRINGER TIE CLIP CRACKED AT STA 847 STR 4L. REPLACED TIE CLIP PER SRM 51-40-02.
- 1 Sep 2005
Battery Pack, discharged
PIT - MAINTENANCE REPORTED THE SEAT MOUNTED EMERGENCY LIGHTS FROM ROWS 12 THROUGH 19 INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BATTERY PACK AND FUSE.…
- 8 Aug 2005
Charger, inoperative
PIT - MAINTENANCE REPORTED FOUR EMERGENCY LIGHTS AT SEAT ROWS 7 THROUGH 10 INOPERATIVE. MAINTENANCE REMOVED AND REPLACED CHARGER ASSEMBLY M1134 AND THE…
- 12 Jan 2005
Skin, cracked
CLT - FOUND SKIN 2.5 INCHES CRACK, STATION 727G STRINGER 22L. INSTALLED DOUBLER IAW SRM 53-00-1. (M)
- 16 Aug 2004
Structure, cracked
PIT - FOUND FORWARD SERVICE DOOR CRACKED .5 INCH, TWO EACH, FORWARD MOST RIVET HOLE IN ROW DIRECTLY UNDER UPPER HINGE ARM. CUT OUT DAMAGE, INSTALLED FILLER…
- 25 Jul 2004
Light, inoperative
ORD - MAINTENANCE FOUND THE FORWARD MAIN ENTRY DOOR EXTERIOR EMERGENCY LGIHT INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE EXTERIOR EMERGENCY EXIT…
- 15 Jul 2004
Skin, cracked
CLT - FOUND SKIN CRACKED .8 INCH, EXTERIOR FUSELAGE SKIN BELOW S23L AT STATION 727D. INSTALLED DOUBLER PER SRM 53-00-01. (M)
- 7 Jan 2003
Skin, cracked
CLT - FOUND SKIN CRACKED 1.5 INCHES LONG, STATION 727E AT STRINGER 23 RIGHT. INSTALLED DOUBLER PER TYPICAL REPAIR 53-60-03. (M)
- 24 Sep 2002
Skin, cracked
FUSELAGE SKIN CRACKED, STA 727D AT STRINGER 23L, 2.2500 CRACK. INSTALLED EXTERIOR DOUBLER IAW SRM.
- 16 Jan 2002
Skin, delaminated
PIT - FOUND ELEVATOR DELAMINATED .375 INCH, OUTER PLIES ON LOWER SKIN 75.5 FROM TIP 8 FROM L/E. REPAIRED PER SRM 55-20-01 AND 51-70-17 .5 INCH PER PLY PER EA…
- 11 Jan 2002
Sleeve, damaged
PIT - FOUND SLEEVE RIGHT WITH 3 INCH PUNCTURE, INNER AND OUTER SKIN AND HONEYCOMB CORE 6 INCH EDGE PANEL. COMPOSITE REPAIR IAW 54-30-70 FIG 201 AND SRM…
- 9 Jan 2002
Splice, damaged
PIT - FOUND STRINGER WITH 16 INCH SPLICE, FORWARD CARGO STRINGER 27R STATION 500E TO 500F. REPAIRED WITH 16 INCH SPLICE PER SRM 53-00-03 FIG 201. (M)
- 4 Jan 2002
Hinge Fitting, corroded
PIT - FOUND SCATTERED CORROSION ON HINGE SUPPORT FITTING 2 SQUARE INCHES, NR 6 HORIZONTAL STABILIZER TO ELEVATOR FITTING, LEFT HINGE SUPPORT FITTING.…
- 12 Aug 2000
Battery Pack, discharged
ATL - DURING OVERNIGHT CHECK, MAINTENANCE FOUND A SECTION OF FLOOR PROXIMITY EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE M1136 BATTERY…
- 11 Aug 2000
Charger, failed
PHL - MAINTENANCE FOUND THE MID-CABIN EMERGENCY LIGHT INOPERATIVE. MAINTENANCE REMVOED AND REPLACED THE BATTERY PACK (P/N AD2013-1A) AND CHARGER ASSY. OPS…
- 25 Apr 2000
Vane, failed
PHL - FLT 1167 - ON CLIMB-OUR FROM PHL, THE CREW RECEIVED A CONTINUOUS STICK SHAKER. CREW ACCOMPLISHED PROCEDURES AND PULLED THE STALL WARNING, ASYMMETRY MODE…
- 22 Aug 1998
Outflow Valve, failed
MIA - FLT 1431 - ON CLIMB-OUT FROM MIA, CREW WAS UNABLE TO PRESSURIZE AIRCRAFT OR CONTROL CABIN IN STANDBY OR MANUAL MODES. FLIGHT RETURNED TO FIELD AT MIA…
- 25 Nov 1997
Controller, failed
PIT - FLT 721 - CAPTAIN REPORTED AIRCRAFT WOULD NOT PRESSURIZE AFTER TAKEOFF. FLIGHT RETURNED TO FIELD AT PIT AND LANDED WITHOUT FURTHER INCIDENT. NO…
- 23 Apr 1995
Valve, inop
PBI - FLT 188 - UNABLE TO PRESSURIZE ACFT AFTER TAKEOFF. FLIGHT RETURNED TO PBI WHERE LANDING WAS WITHOUT FURTHER INCIDENT. MAINTENANCE FOUND DUCT CLAMP AND…
- 23 Apr 1995
Clamp, loose
PBI - FLT 188 - UNABLE TO PRESSURIZE ACFT AFTER TAKEOFF. FLIGHT RETURNED TO PBI WHERE LANDING WAS WITHOUT FURTHER INCIDENT. MAINTENANCE FOUND DUCT CLAMP AND…
- 27 Feb 1995
Fuse, inoperative
CLT - EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE RPELACED FUSE ON M1479 EMERGENCY LIGHT BATTERY PACK AND RESAFTIED AFT FLIGHT ATTENDANT EMERGENCY EXIT LIGHT…