N443SW
Bombardier INC CL-600-2B19 FAA →
registration
service difficulty reports
151 reports
- 14 May 2021
Frame, corroded
MAIN AVIONICS COMPARTMENT, FRAME FS 394.00 HAS SURFACE CORROSION ON FWD LOWER CAP BETWEEN STGR 26L-26R. (FILED CLOSED) REMOVED AND REPLACED SKIN SUPPORT ON…
- 31 Mar 2020
Skin, scratched
TRANSFER FROM EAML 410648 : SCRATCH DOWN TO BARE METAL. APROX 5 FEET BEHIND SERVICE DOOR, EYE LEVEL. DAMAGE FOUND TO BE AT FUSELAGE SKIN BETWEEN FS409.00 AND…
- 7 Aug 2019
Strut, failed
GEAR DISAGREE AFTER TAKEOFF. FOLLOWED QRH - RTF. FLT 4992. REMOVED AND REPLACED NLG DRESSED SHOCK STRUT IAW AMM. OPS CHECK GOOD.
- 6 Jul 2019
Fitting, damaged
THREE LOOSE BOLTS NOTED DURING INSPECTION OF HORIZONTAL STABILIZER STEADY FITTING (P/N 600-21402), REQUIRES FURTHER INSPECTION/REPAIR. REPAIRED HORIZONTAL…
- 3 Jul 2019
Floor Support, corroded
LH FLOOR SILL HAS TWO SPOTS OF CORROSION AROUND NUTPLATE HOLES BETWEEN F.S. 439.00 AND F.S. 449.85 LBL 42. (C-CHECK) REPAIRED LH FLOOR SILL IAW REO.
- 2 Jul 2019
Attach Bracket, corroded
PAX DOOR INTERCOSTAL DD5, ATTACH BRACKET CORRODED. (C-CHECK) REMOVED AND REPLACED BRACKET IAW SRM.
- 2 Jul 2019
Intercostal, corroded
PAX DOOR INTERCOSTAL DD6, CORRODED. (C-CHECK) REMOVED AND INSTALLED NEW SERVICEABLE CLEAT IAW SRM.
- 1 Jul 2019
Intercostal, corroded
UPON REMOVAL OF PAX DOOR INNER SKIN, FOUND UPPER INTERCOSTAL UNDER LATCH-LOCK BOX TO BE CORRODED. (C-CHECK) RO: 08/06/2019 LOCATED, DRILLED AND INSTALLED NEW…
- 1 Jul 2019
Cleat, corroded
PAX DOOR CLEAT IS CORRODED. BS 311.75 ATTACHED TO INTERCOSTAL DD4. (C-CHECK) REMOVED AND INSTALLED NEW SERVICEABLE CLEAT IAW SRM.
- 1 Jul 2019
Intercostal, corroded
PAX DOOR INTERCOSTAL DD7A IS CORRODED. (C-CHECK) LOCATED, DRILLED AND INSTALLED NEW SERVICEABLE PAX DOOR LWR FWD INTERCOSTAL (DD7A) IAW SRM.
- 1 Jul 2019
Intercostal, corroded
PAX DOOR INTERCOSTAL CORRODED LOCATED APPROX: FS 347.25. (C-CHECK) REINSTALLED NEW PAX DOOR INTERCOSTAL IAW REO.
- 1 Jul 2019
Intercostal, corroded
PAX DOOR INTERCOSTAL DD6 IS CORRODED. (C-CHECK) LOCATED, DRILLED AND INSTALLED NEW SERVICEABLE PAX DOOR INTERCOSTAL IAW SRM.
- 28 Jun 2019
Trunnion, damaged
RH TRUNNION HAS 1EA OVERSIZE FASTENER HOLE AT AFT MOST HOLE THROUGH STEEL PLATE. (C-CHECK) REPAIRED RT TRUNNION 1EA OVERSIZED FASTENER HOLE AT AFT MOST HOLE…
- 25 Jun 2019
Frame, corroded
FS 349 FRAME IS CORRODED ON THE AFT FACE OF THE FRAME BETWEEN STR 26L AND 26R. (C-CHECK) RO: 08/06/2019 REMOVED AND REPLACED FRAME SECTION WITH NEW P/N…
- 25 Jun 2019
Floor Support, corroded
FLOOR BEAM CAP IS CORRODED BETWEEN F.S. 589.00 AND F.S. 621.00 AROUND FASTENER HOLES ON LBL 9. (C-CHECK) RO: 08/06/2019 REMOVED DAMAGED FLOOR BEAM CAP AT…
- 22 Jun 2019
Skin, chafed
L/H LOWER WING PLANK CHAFED AT TRAILING EDGE OF ACCESS PANEL 193AB LBL 45.0. (C-CHECK) PERFORMED CHAFING REPAIR TO L/H LOWER WING PLANK AT TRAILING EDGE OF…
- 19 Jun 2019
Bulkhead Web, cracked
4EA AREAS OF CRACK INDICATIONS NOTED ON FS621 RPB WEB IN THE HEEL LINE AREA OF VERT POSTS, (C-CHECK) RO: 08/06/2019 REPAIRED IAW REO.
- 19 Jun 2019
Door Frame, corroded
PAX DOOR FWD FRAME IS CORRODED INSIDE PANEL 832HL.(C-CHECK). INSTALLED NEW SERVICEABLE PAX DOOR FWD FORMER IAW SRM.
- 19 Jun 2019
Intercostal, corroded
PAX DOOR FWD INTERCOSTAL IS CORRODED INSIDE PANEL 832GL. C-CHECK. REMOVED AND REPLACED PAX DOOR FWD INTERCOSTAL IAW SRM.
- 21 May 2019
Selector Valve, failed
MOMENTARY GEAR DISAGREE ON FINAL WHEN PUTTING GEAR DOWN (NOSE WHEEL), NOSE DOOR WARNING MESSAGE. EXTINGUISHED AND ALL INDICATIONS WERE GREEN AND NORMAL…
- 26 Sep 2018
Strut, discharged
GEAR DISAGREE MASTER WARNING. NOSE GEAR WOULD NOT RETRACT. (FLT#4574) CLOSED PERFORMED FULL OIL AND NITROGEN SERVICE ON THE NLG ASSY IAW AMM. JACKED AIRCRAFT…
- 11 Jun 2018
Pump, weak
GEAR DISAGREE ON APPROACH. REMOVED AND REPLACED HYDRAULIC PUMP 3A IAW AMM. OPS CHECKED GOOD, NO LEAKS NOTED. PERFORMED GEAR SWINGS IAW AMM. OPS CHECKED GOOD
- 20 May 2018
Window Frame, cracked
WINDOW FRAME CRACKED.
- 30 May 2017
Floor Support, corroded
FLOOR SUPPORT HAS CORROSION ON THE RIGHT SIDE BS 319.7. INSTALLED A NEW FLOOR SUPPORT IAW SRM AND REO.
- 28 May 2017
Angle, corroded
LOWER STOP FITTING ON PAX DOOR LOCK MECHANISM IS CORRODED AROUND THE STOP BOLT. INSTALLED A NEW LOWER STOP FITTING ANGLE IAW SRM.
- 26 May 2017
Panel, chafed
AILERON LEADING PANEL 599AB IS CHAFED. INSTALLED A NEW LEADING EDGE PANEL IAW SRM.
- 23 May 2015
Floor Panel, delaminated
FLOOR PANEL 343AR HAS DELAMINATION. R & R THE FLOOR PANEL IAW EA.
- 22 May 2015
Floor Panel, cracked
CRACKS NOTED ON FUSELAGE PRESSURE FLOOR PANEL BS 461, RBL 9 TO LBL 9. REPAIRED IAW REO.
- 21 May 2015
Floor Support, corroded
PRESSURE FLOOR SUPPORT BS 499 - 513 AT LBL 45 HAS CORROSION. REPAIRED THE FLOOR SUPPORT IAW REO.
- 21 May 2015
Floor Support, corroded
PRESSURE FLOOR SUPPORT BS 460 - 473.15 LBL 45 HAS CORROSION. REPAIRED THE FLOOR SUPPORT IAW REO.
- 21 May 2015
Floor Support, corroded
PRESSURE FLOOR SUPPORT BS 559 LBL 45 HAS CORROSION. REPAIRED IAW SRM.
- 21 May 2015
Floor Support, corroded
PRESSURE FLOOR SUPPORT BS 424 LBL 45 HAS CORROSION. REPAIRED IAW REO.
- 21 May 2015
Floor Support, corroded
PRESSURE FLOOR SUPPORT BS 460 - 461 RBL 45 HAS CORROSION. REPAIRED THE FLOOR SUPPORT IAW REO.
- 21 May 2015
Floor Support, corroded
PRESSURE FLOOR SUPPORT BS 473.15 RBL 45.0 HAS CORROSION. REPAIRED THE FLOOR SUPPORT IAW REO.
- 21 May 2015
Floor Support, corroded
PRESSURE FLOOR SUPPORT BS 484 RBL 45 HAS CORROSION. REPAIRED IAW REO.
- 21 May 2015
Floor Support, corroded
PRESSURE FLOOR SUPPORT BS 499 RBL 45 HAS CORROSION. REPAIRED IAW REO.
- 21 May 2015
Floor Support, corroded
PRESSURE FLOOR SUPPORT BS 599 RBL 45.0 HAS CORROSION. REPAIRED IAW REO.
- 20 May 2015
Bulkhead, cracked
CRACK NEXT TO PARKING BREAK BULKHEAD FITTING BS 202. REPAIRED IAW REO.
- 19 May 2015
Skin, chafed
LT INBD GROUND SPOILER IS CHAFED ON LOWER L/E SKIN OTBD OF INBD HINGE APPROXIMATELY SP STA 56.177. BLENDED CHAFE AT LOWER FLANGE OF LT INBD GROUND SPOILER AT…
- 19 May 2015
Lug, gouged
LEFT AILERON CENTER OTBD PCU LINK LUG ON AILERON IS GOUGED. REPAIRED LT AILERON CENTER OTBD PCU LINK LUG GOUGE IAW REO.
- 19 May 2015
Door, dented
RT FUSELAGE BELOW POTABLE WATER SERVICE DOOR DENTED. REPAIRED THE DOOR IAW EA AND AMM.
- 18 May 2015
Cap, chipped
LT HORIZONTAL STABILIZER END CAP L/E INBD CHIPPED. REPAIRED THE LT HORIZONTAL STAB END CAP L/E IAW SRM.
- 18 May 2015
Cap, chipped
RIGHT HORIZONTAL STABILIZER END CAP CHIPPED OTBD L/E. REPAIRED THE HORIZONTAL STAB END CAP L/E IAW SRM.
- 17 May 2015
Skin, dented
DENT ON RT ELEVATOR LOWER SURFACE BETWEEN ES 69.103 - 77.682, AND BETWEEN RIBS 9 AND 10. COMPLIED WITH PERMANENT REPAIR IAW EA.
- 27 Apr 2015
O-Ring, failed
FUEL ODOR IN FLIGHT AND ON THE GROUND COMING FROM THE GASPER VENTS. REPLACED O-RING ON APU FUEL CONTROL OUTLET, NO FUEL ODOR.
- 15 Nov 2014
Battery Pack, failed
EMERGENCY LIGHTS FLOOR STRIP BETWEEN ROW 2 THRU 8 AND LT LOWER SIDEWALL EXIT LIGHT AT OVERWING E EXIT INOPERATIVE. R & R BATTERY PACK NR 1 AND NR 4 ALSO…
- 14 Nov 2014
Warning Message, false activation
DURING TAKEOFF AT 800 FT, RECEIVED RT AOA HEAT CAUTION MESSAGE. RAN QRH. DID NOT FIX. RETURN TO FIELD. RESET IAW FIM INTRODUCTION-MSG CLEARED.
- 14 Nov 2014
Warning Message, false activation
AFTER TAKEOFF AT 1100 FT, RECEIVED RT PITOT HEAT CAUTION MESSAGE. RAN QRH - DID NOT FIX. RETURNED TO FIELD. RESET IAW FIM INTRODUCTION - MSG CLEARED.
- 3 Oct 2014
Skin, dented
RIGHT ELEVATOR BOTTOM SIDE DENTED. REPAIRED IAW REO.
- 2 Oct 2014
Battery Pack, inoperative
SECOND OVERHEAD EMERGENCY FLOODLIGHT FROM THE BACK IS INOPERATIVE. R & R NR 3 EMERGENCY LIGHT BATTERY IAW AMM. PN ON: 2013-1A, PN OFF: AD-2013-1A, SN ON:…
- 6 Aug 2014
Uplock Switch, out of adjust
LT MAIN GEAR EICAS BOX DID NOT GO GREEN. PSEU FLAGS S20. ADJUSTED UPLOCK PROXIMITYSWITCH S20.
- 24 May 2014
Lamp, burned out
RIGHT AND LEFT WING MIDDLE EMERGENCY LIGHTS INOPERATIVE, REPLACED THE LAMPS.
- 29 Apr 2014
Skin, damaged
SKIN DAMAGED ON RT SIDE OF ACFT BELOW WINDOW APPROXIMATELY FS430 AND STRINGER 15A. DAMAGE IS ACTUALLY LOCATED BETWEEN FS409+96-FS409+112, STR 15R-STR 16R DENT…
- 26 Apr 2014
Skin, damaged
SKIN DAMAGED UNDERNEATH F/O WINDSHIELD FWD OF SIDE WINDOW DUE TO BIRDSTRIKE. DAMAGE IS LOCATED BETWEEN FS 220.00-FS235.00 AND BETWEEN THE CO-PILOT WINDSHIELD…
- 29 Jan 2014
Sign, broken
MAIN CABIN DOOR EMERGENCY EXIT SIGN BROKEN. FLT 4647 RELAMPED, PN BR9279-22.
- 25 Oct 2013
Light, inoperative
EMERGENCY LIGHT POD BURNED OUT. FLT 4475 RELAMPED.
- 23 Aug 2013
Skin Panel, damaged
RT EXTERNAL FS SKIN PANEL DAMAGED BETWEEN FS 625.30 & FS640, STRINGERS 18R TO 20R. C-CHECK REPAIRED IAW REO.
- 17 Aug 2013
Bulkhead, cracked
FS 280 BULKHEAD WEB CRACKED OUT OF FASTENER HOLE AT INBD SIDE OF RBL9.0. C-CHECK REPAIRED IAW REO.
- 13 Aug 2013
Bulkhead, damaged
REAR PRESSURE BULKHEAD WEB HAS INDICATION NOTED AT BL0.0 WL 110 APPROXIMATELY 1.3 INCHES IN LENGTH. C-CHECK REPAIRED REAR PRESSURE BULKHEAD WEB HAS INDICATION…
- 4 Aug 2013
Light, inoperative
EMERGENCY OVERHEAD LIGHT ROW 12 & 13 IS BURNED OUT. FLT#7428 RELAMPED.
- 26 Jul 2013
Light, disconnected
FIRST EMERGENCY LIGHT STRIP ON FLOOR DOES NOT ILLUMINATE. FLT#5337 RE-CONNECTED FIRST EMERGENCY LIGHT STRIP.
- 7 Jun 2013
Light, inoperative
LEFT AFT OVERWING EMERGENCY LIGHT IS BURNED OUT. RELAMPED.
- 17 Nov 2012
Light, inoperative
NR 1 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 5373) RELAMPED EMERGENCY LIGHT.
- 9 Sep 2012
Battery Pack, failed
OVERHEAD EMERGENCY EXIT SIGN AT ROW 8 IS OUT. (FLT 4458) REPLACED BATTERY PACK ELBP NR 2 AND ELBP BATTERY CHARGER NR 2 IN REFERENCE TO AMM. P/N: AD-2013-1A…
- 10 Jul 2012
Light, inoperative
NR 3 OVERHEAD EMERGENCY LIGHT IS BURNED OUT. (FLT 5261) RELAMPED EMERGENCY LIGHT.
- 8 Jun 2012
Light, inoperative
NR 1 AND NR 3 OVERHEAD EMERGENCY LIGHTS ARE OUT. (FLT 4754) RELAMPED EMERGENCY LIGHTS.
- 15 May 2012
Light, inoperative
NR 3 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 4499) RELAMPED EMERGENCY LIGHT.
- 19 Mar 2012
Light, inoperative
NR 3 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 4557) RELAMPED EMERGENCY LIGHT.
- 21 Jan 2012
Drain Line, contaminated
FIRST OFFICER'S IVSI FLUCTUATING +/- 1000 FT. ALTIMETER FLUCTUATING +/- 100. BOTH WHILE CAPTAIN SIDE STABLE. (FLT 3975) REMOVED MOISTURE FROM NR 2 ADC PITOT…
- 8 Jan 2012
Inverter, failed
LEFT EMERGENCY EXIT LIGHT IS OUT. (FLT 6281) REPLACED NR 2 EMERGENCY LIGHT INVERTER.
- 15 Dec 2011
Light, inoperative
LEFT FORWARD, RIGHT FORWARD AND RIGHT AFT EXTERIOR EMERGENCY LIGHTS INOPERATIVE. (FLT 5263) RELAMPED EMERGENCY LIGHTS.
- 14 Dec 2011
Light, inoperative
THE 3RD OVERHEAD EMERGENCY CEILING LIGHT INOPERATIVE. (FLT 5363) RELAMPED EMERGENCY LIGHT.
- 20 Nov 2011
Light, inoperative
LEFT SIDE MIDDLE EXTERIOR OVERWING EMERGENCY LIGHT IS OUT. (FLT 5484) RELAMPED EMERGENCY LIGHT.
- 21 Oct 2011
Skin, cracked
FORWARD FUSELAGE SKIN CRACKED AT LEFT TRU DOOR AFT LATCH. (C-CHECK) REPLACED FUSELAGE SKIN PER SRM.
- 21 Oct 2011
Skin, damaged
FUSELAGE SKIN ABOUT 20 INCHES ABOVE GROUND AIR PORT, AFT OF 1ST SPLICE OF CARGO IS DENTED. (C-CHECK) REPAIRED PER REO.
- 19 Oct 2011
Skin, cracked
PASSENGER DOOR INNER SKIN HAS A CRACK AT FS 340 WHERE SKIN MATES TO INTERCOSTAL AT LOWER PORTION OF PAX DOOR. (C-CHECK) REPAIRED IAW CRJ200 SRM.
- 19 Oct 2011
Bulkhead, cracked
CRACK INDICATED ON THE LEFT SIDE FS 559.0 PRESSURE BULKHEAD. (C-CHECK) REPAIRED PER REO.
- 19 Oct 2011
Post, cracked
CRACK AT FS 409.0+128 BL 0.00 LEFT AND RIGHT AFT RADIUS OF VERTICAL POST. (C-CHECK) REPAIRED IN REFERENCE TO CRJ200 SRM.
- 19 Oct 2011
Post, cracked
CRACK AT FS 409.0+128 BL 18.00 OUTBOARD AFT RADIUS OF VERTICAL POST. (C-CHECK) REPLACED VERTICAL POST IN REFERENCE TO CRJ200 SRM.
- 29 Mar 2011
Light, inoperative
LEFT AND RIGHT OVERWING EXTERIOR EMERGENCY LIGHTS ARE OUT. (FLT 6872) RELAMPED EMERGENCY LIGHT.
- 4 Mar 2011
Sign, low
AFT OVERWING EMERGENCY EXIT SIGN ILLUMINATES VERY DIMLY. (FLT 6407) REPLACED AFT OVERWING EMERGENCY EXIT SIGN ASSEMBLY.
- 27 Feb 2011
Light, inoperative
AFT OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 6452) RELAMPED EMERGENCY LIGHT.
- 2 Dec 2010
Light, inoperative
AFT OVERHEAD EMERGENCY LIGHT INOPERATIVE. (FLT 6700) RELAMPED EMERGENCY LIGHT.
- 3 Oct 2010
Shaft, damaged
RIGHT ENGINE AFT THRUST SHAFT SCORED. (ENGINE CHANGE) REPLACED RIGHT ENGINE AFT MOUNT THRUST SHAFT PER AMM.
- 3 Oct 2010
Bolt, damaged
RIGHT ENGINE FORWARD MOUNT BOLT IS SCORED. (ENGINE CHANGE) REPLACED ONE RIGHT ENGINE FORWARD MOUNT BOLT PER AMM.
- 3 Oct 2010
Link, corroded
RIGHT ENGINE FORWARD MOUNT LINK ASSEMBLY PITTED. (ENGINE CHANGE) REPLACED RIGHT ENGINE FORWARD MOUNT YOKE LINK ASSEMBLY PER AMM.
- 11 Jan 2010
Bulkhead, cracked
FS 621 AFT BULKHEAD CRACKED AT CARGO DOOR ROLLER GUIDE TRACK. (C CHECK) REPAIRED PER REO.
- 8 Jan 2010
Bulkhead, cracked
FS 559 BULKHEAD AT RBL 18 WL 59 CRACKED. (C CHECK) REPAIRED PER REO.
- 23 Dec 2009
Light, inoperative
NR 2 AND NR 4 EMERGENCY CEILING LIGHTS INOP. (FLT 6450) RELAMPED EMERGENCY CEILING LIGHT.
- 27 Oct 2009
Trim Panel, failed
RUDDER TRIM RUNAWAY DURING APPROACH WITH FULL RIGHT DEFLECTION. (FLT 5928) REPLACED RUDDER TRIM PANEL.
- 19 Oct 2009
Light, inoperative
EMERGENCY EXIT LIGHT ON AIRCRAFT EXTERIOR ABOVE RIGHT WING INOP. (FLT 5848) RELAMPED EMERGENCY LIGHT.
- 23 Sep 2009
Light, inoperative
NR 1 EMERGENCY LIGHT POD IN CABIN INOP. (FLT 6575) RELAMPED IAW CRJ200 MM 33-51-01.
- 9 Aug 2009
Light, inoperative
NR 3 CEILING EMERGENCY LIGHT INOP. (FLT 4844) RELAMPED EMERGENCY LIGHT.
- 8 Jul 2009
Light, inoperative
EMERGENCY LIGHT NR 4 INOP. (FLT 5991)RELAMPED.
- 1 Jul 2009
Light, inoperative
OVERHEAD EMERGENCY CABIN LIGHT INOP. (FLT 5814) RELAMPED EMERGENCY LIGHT.
- 30 Mar 2009
Lamp, burned out
FLT 4674 - OVERHEAD EMERGENCY EXIT LIGHT ABOVE ROW 10 INOP. RELAMPED.
- 30 Jan 2009
Lamp, burned out
FLT 6391 - NR 2 OVERHEAD EMERGENCY LIGHT INOP. RELAMPED.
- 19 Dec 2008
Battery Pack, failed
FLT 4390 - FLOOR EMERGENCY LIGHTING INOP. REPLACED INVERTER AT EMERGENCY BATTERY NR 3.
- 16 Dec 2008
Lamp, burned out
FLT 4507 - THIRD AFT CEILING EMERGENCY FLOOD LIGHTS INOP. RELAMPED.
- 21 Nov 2008
Sign, inoperative
FLT 5800 - EMERGENCY EXIT SIGN AT ROW 8D INOP. RESECURED CONNECTOR.
- 8 Aug 2008
Bushing, corroded
C-CHECK, RIGHT ENGINE FORWARD MOUNT YOKE FLANGED BUSHINGS CORRODED, REPLACED.
- 8 Aug 2008
Bushing, corroded
C-CHECK, LEFT ENGINE FORWARD MOUNT YOKE FLANGED BUSHING CORRODED, REPLACED.
- 8 Aug 2008
Fitting, corroded
C-CHECK, RIGHT ENGINE THRUST FITTING CORRODED, REPLACED.
- 8 Aug 2008
Floorbeam, cracked
C-CHECK, FS 280 RBL9 SUPPORT CRACKED. REPAIRED PER REO.
- 8 Aug 2008
Floorbeam, cracked
C-CHECK, FS 280 FORWARD FLOOR SUPPORT CRACKED AT RADIUS, REPLACED.
- 8 Aug 2008
Floorbeam, cracked
C-CHECK, FS 280 RBL9 LOWER FLOOR SUPPORT CRACKED. REPAIRED PER REO.
- 8 Aug 2008
Floorbeam, cracked
C-CHECK, FS 280 LOWER FLOOR SUPPORT CRACKED AT LBL9.. REPAIRED PER REO.
- 24 Jul 2008
Sign, broken
BROKEN WINDSCREEN EMERGENCY EXIT SIGN. (FLIGHT NR 4122) REPLACED LIGHT ASSEMBLY. OPS CHECK GOOD.
- 11 Nov 2007
Lamp, burned out
FLT 3751 - EMERGENCY LIGHT PODS AT ROWS 5 AND 10 ARE INOP. RELAMPED AS REQUIRED. OPS CHECK GOOD.
- 2 Nov 2006
Web, cracked
PAX DOOR FWD WEB CRACKED UNDER THE HAND RAIL HOLD DOWN BRACKET. DISCOVERED DURING C-CHECK INSPECTION. INSTALLED DOUBLER AND ANGLES PER REO 601R-52-11-702.
- 2 Nov 2006
Web, cracked
PAX DOOR FWD WEB CRACKED BETWEEN FIXED STEPS 1 & 2. DISCOVERED DURING C-CHECK INSPECTION. INSTALLED DOUBLER, ANGLE AND SHIMS PER REO 52-11-1141.
- 2 Nov 2006
Handle, cracked
PASSENGER DOOR OUTER HANDLE CRACKED. DISCOVERED DURING C-CHECK INSPECTION. REPLACED PASSENGER DOOR OUTER HANDLE P/N 601R31704-7 PER CRJ200 AMM REF 52-11-03 PG…
- 2 Nov 2006
Web, cracked
PASSENGER DOOR AFT WEB CRACKED BETWEEN THE 3RD AND 4TH FIXED STEPS. DISCOVERED DURING C-CHECK INSPECTION. INSTALLED DOUBLER, ANGLE & FILLERS PER REO…
- 2 Nov 2006
Web, cracked
PASSENGER DOOR AFT WEB CRACKED BETWEEN THE FIXED STEPS 1 AND 2 UNDER HANDRAIL HOLD DOWN BRACKET. DISCOVERED DURING C-CHECK INSPECTION. INSTALLED DOUBLER &…
- 2 Nov 2006
Drag Angle, cracked
PASSENGER DOOR AFT DRAG CRACKED AT THE DOOR ASSIST CABLE PULLEY BRACKET. DISCOVERED DURING C-CHECK INSPECTION. INSTALLED NEW DRAG ANGLE SECTION P/N…
- 2 Nov 2006
Arm, cracked
CREW ESCAPE HATCH - LT HINGE ARM IS CRACKED. DISCOVERED DURING C-CHECK INSPECTION. REPLACED AND ADJUSTED LT HINGE ARM ON CREW ESCAPE HATCH REF CRJ200 AMM…
- 2 Nov 2006
Floorbeam, cracked
THE 280 FLOOR SUPPORT CRACKED RIGHT HAND UPPER RBL 9.0 RIGHT HAND INBOARD AND OUTBOARD CLIP CRACKED. DISCOVERED DURING C-CHECK INSPECTION. INSTALLED CLIPS P/N…
- 2 Nov 2006
Floorbeam, cracked
THE 280 FLOOR SUPPORT CRACKED LT UPPER LBL 10 LT INBOARD CLIP CRACKED. DISCOVERED DURING C-CHECK INSPECTION. INSTALLED CLIPS P/N 601R31113-57 & ANGLES AT FS…
- 2 Nov 2006
Attach Bracket, cracked
STA 484 FAIRLEAD BRACKET INBOARD AND OUTBOARD CLIPS CRACKED LBL 27 AND 36. DISCOVERED DURING C-CHECK INSPECTION. INSTALLED NEW CLIP AND NEW REPAIR ANGLE IAW…
- 2 Nov 2006
Support Beam, cracked
ENGINE SUPPORT BEAM LOWER WEB CRACKED AT LT ACCESS COVER OPENING. DISCOVERED DURING C-CHECK INSPECTION. INSTALLED REPAIR DOUBLER, SHIM, STRAP AND WEB FILLER…
- 2 Nov 2006
Support Beam, cracked
ENGINE SUPPORT BEAM LOWER WEB CRACKED AT RT ACCESS COVER OPENING. DISCOVERED DURING C-CHECK INSPECTION. INSTALLED REPAIR DOUBLER, WEB FILLER & STRAP IAW…
- 12 Sep 2006
Pump, leaking
HYDRAULIC PAGE SHOWED PRESSURE BUT "O" (QUANTITY) FLUID. REPLACED NR 2 EDP IAW 29-11-01. OPERATIONAL CHECKS GOOD.
- 12 Apr 2006
Bulb, burned out
ONE OVERHEAD EMERGENCY FLOODLIGHT IS INOP. REPLACED OVERHEAD EMERGENCY FLOODLIGHT BULB. OPERATIONAL CHECK GOOD.
- 22 Jan 2006
Door, out of rig
SERVICE DOOR IS HARD TO OPEN AND CLOSE. RIGGED DOOR AS NEEDED, OPERATIONAL CHECK GOOD.
- 27 Dec 2005
Lamp, burned out
CEILING "LEVEL" EMERGENCY LIGHT (FLOOD) 1 AT FARTHEST AFT "INOP". RELAMPED LAMP. OPERATIONAL CHECK GOOD.
- 17 Sep 2005
Pcu, malfunctioned
ON DEPARTURE THROUGH 2000' RT FLIGHT SPOILER DEPLOYED MSG WAS DISPLAYED, FOLLOWED BY A SPOILER FAULT MESSAGE. REPLACED RT OB FLIGHT SPOILER PCU IAW MM…
- 7 Jul 2005
Control Unit, malfunctioned
FLAPS HALFSPEED STATUS MESSAGE. REPLACED FLAP ELECTRONIC CONTROL UNIT IAW MM 27-51-05. OPERATIONAL CHECK GOOD.
- 31 May 2005
Window, cracked
DURING DESCENT INTO SLC, F/O'S SIDE WINDOW CRACKED. REPLACED RIGHT SIDE WINDOW PER MM 56-12-01. OPERATIONAL CHECK GOOD. P/N OFF 601R33033-12, S/N OFF…
- 21 May 2005
Smoke Detector, malfunctioned
SMOKE CARGO WARNING ON THE GROUND, NO SMOKE OBSERVED. REMOVED AND REPLACED FWD CARGO SMOKE DETECTOR IAW M/M 26-15-01. OPERATIONAL CHECK GOOD. P/N 478597-19;…
- 4 May 2005
Lamp, burned out
AFT CEILING EMERGENCY LIGHT INOPERATIVE. RELAMPED AFT CEILING EMERGENCY LIGHT IAW CRJ MM33-51-00. OPERATIONAL CHECK GOOD.
- 11 Apr 2005
Intercostal, cracked
FS 484 RIGHT INTERCOSTAL OUTBOARD FLANGE RBL 36 CRACKED, ITEM FOUND AT C-CHECK INSPECTION. REPAIRED INTERCOSTAL IAW CRJ REO 601R-53-41-059 REV A.
- 11 Apr 2005
Floorbeam, cracked
FS 460 RIGHT OUTBOARD FLOOR FITTING RBL 9.0 CRACKED, ITEM FOUND AT C-CHECK INSPECTION. REPAIRED IAW CRJ SRM 51-42-06, 51-42-21, 51-23-00, 51-25-16 & 51-21-11.
- 11 Apr 2005
Intercostal, cracked
FS 625 LEFT INTERCOSTAL ANGLE STR 14L CRACKED, ITEM FOUND AT C-CHECK INSPECTION. REPLACED ANGLE IAW CRJ SRM 51-40-11, 51-42-06.
- 11 Apr 2005
Intercostal, cracked
FS 625 RIGHT INTERCOSTAL ANGLE STR 14R CRACKED, ITEM FOUND AT C-CHECK INSPECTION. REPLACED ANGLE IAW CRJ SRM 51-40-11, 51-42-06.
- 11 Apr 2005
Floorbeam, cracked
FS 621 RIGHT SIDE FLOOR SUPPORT ANGLE RBL 42 CRACKED, ITEM FOUND AT C-CHECK INSPECTION. CRACKED ANGLE REPAIRED IAW CRJ REO 601R-53-61-117 REV "B" .
- 11 Apr 2005
Sill, corroded
FS 589.0 CARGO BAY FLOOR SILL RBL 44 ANGLE CORRODED, ITEM FOUND AT C-CHECK INSPECTION. ANGLE REPLACED IAW CRJ SRM 51-40-11, 51-42-06, 51-42-21, 51-23-00,…
- 1 Apr 2005
Pcu, malfunctioned
SPOILERON FAULT STATUS MESSAGE. REPLACED LEFT SPOILERON INBOARD PCU IAW MM 27-62-01. OPERATIONAL CHECK GOOD.
- 9 Sep 2004
Lamp, burned out
ONE CEILING EMERGENCY LIGHT IS INOPERATIVE. RELAMPED EMERGENCY LAMP. OPERATIONAL CHECK GOOD.
- 8 Mar 2004
Gearbox, malfunctioned
NR 1 THRUST LEVER STUCK AT CRUISE POWER SETTINGS. PERFORMED QRH AND SHUT DOWN NR 1 ENGINE. REMOVED AND REPLACED LT POWER LEVER CONTROL GEAR BOX IAW CRJ MM…
- 9 Feb 2004
Actuator, failed
FLAPS HALFSPEED STATUS ON TAXI OUT. FOUND 3 OF THE 4 ACTUATORS FAILED TORQUE CHECK. REMOVED AND REPLACED ALL FLAP ACTUATORS LT AND RT SIDE IAW MM 27-53-01 AND…
- 27 Jan 2004
Fcu, out of rig
AFTER TAKEOFF, SELECTED FLAP FROM 20 DEGREES TO 8 DEGREES AND GOT A FLAPS FAIL MESSAGE. RETURNED TO FAT. RE-RIGGED FECU IAW 27-51-10. OPS CHECK GOOD ON GROUND.
- 30 Nov 2003
Pcu, malfunctioned
SPOILERONS FAULT ON TAXI OUT. REMOVED AND REPLACED LEFT INBOARD FLIGHT SPOILERON PCU IAW CRJ AMM 27-62-01. OPS CHECK GOOD.
- 21 Oct 2003
Floorbeam, cracked
FS 280 LT FLOORBEAM LBL 9.0 IB AND OB ATTACH ANGLES CRACKED. (DISCOVERED DURING C-CHECK INSPECTION) REPLACED ANGLES IAW CRJ SRM 51-40-11. P/N: 601R31113-57
- 21 Oct 2003
Floorbeam, cracked
FS 280 RT FLOORBEAM RBL 9.0 IB AND OB ATTACH ANGLES CRACKED. (DISCOVERED DURING C-CHECK INSPECTION) REPLACED ANGLES IAW CRJ SRM 51-40-11. P/N: 601R31113-58
- 21 Oct 2003
Intercostal, cracked
FS 484 LT INTERCOSTAL OB FLANGE LBL 36 CRACKED. (DISCOVERED DURING C-CHECK INSPECTION) REPAIRED INTERCOSTAL IAW CRJ RE 601R-53-41-059 REV ''A'' & RII 53-401.
- 21 Oct 2003
Floor Support, cracked
FS 621.00, LBL 42, FLOOR SUPPORT ANGLE CRACKED. (DISCOVERED DURING C-CHECK INSPECTION) DAMAGE REPAIRED IAW CRJ REO 601R-53-61-117 REV ''A'', RII 53-401. P/N:…
- 26 May 2003
Bulb, burned out
RT WING FORWARD EMERGENCY LIGHT INOP. REPLACED BULB PER CRJ MM 33-51-21. OPS CHECK GOOD.
- 17 Feb 2003
Wire, corroded
EMERGENCY ROW EXIT LIGHTS OUT IN THE BACK SECTION. FOUND WIRE PIGTAIL FOR AFT LIGHT SECTION TO BE CORRODED. REPLACED PIGTAIL. OPS CHECK GOOD.
- 1 Jan 2003
Heater, malfunctioned
LT AOA HEAT CAUTION MESSAGE CAME ON IN FLIGHT, WOULD NOT GO OUT. CYCLED POWER AND COULDN'T DUPLICATE PROBLEM. PROBE HEATED OK.
- 13 Sep 2002
Control Unit, malfunctioned
STAB TRIM CH 2 AND MACH TRIM DISENGAGED CLIMBING OUT OF SLC. RAN QRH PROCEDURE. DID NOT RE-ENGAGE. RETURNED TO SLC. REMOVED AND REPLACED HORIZONTAL STABILIZER…
- 17 Aug 2002
Control Unit, malfunctioned
SHORTLY AFTER ROTATION, STAB TRIM NR 2 AND MACH TRIM WENT INOP AND WOULD NOT RESET. PERFORMED QRH AND RETURNED TO DFW. REMOVED AND REPLACED HORIZONTAL STAB…