N436AA
Anduril Industries INC ROADRUNNER FAA →
registration
earlier registrations
1 past record
- 1987
service difficulty reports
90 reports
- 22 Jul 2016
Warning Light, illuminated
DURING DESCENT RECEIVED A NR 1 BRAKE HIGH TEMPERATURE INDICATION. EMERGENCY DECLARED. LANDING UNEVENTFUL. MAINTENANCE OBSERVED NR 1 BRAKE TEMPERATURE READING…
- 8 Apr 2016
Pump, malfunctioned
AIRCRAFT WAS GNDED. DURING TAKEOFF, THE NR 2 ENG EXPERIENCED AN UNCOMMANDED POWER REDUCTION. TAKEOFF WAS ABORTED AT APPROX 110 KNOTS. R & R RT ENG DRIVEN FUEL…
- 8 Apr 2016
Fcu, faulty
AIRCRAFT WAS GNDED. DURING TAKEOFF, THE NR 2 ENG EXPERIENCED AN UNCOMMANDED POWER REDUCTION. TAKEOFF WAS ABORTED AT APPROX 110 KNOTS. R & R RT ENG DRIVEN FUEL…
- 20 Feb 2016
Boot, dislodged
TAIL COMP HIGH INDICATION SHORTLY AFTER TAKEOFF. PERFORMED RED BOX & QRH PROCEDURES. THE FLIGHT DECLARED AN EMER. LIGHT EXTINGUISHED AFTER 3 OR 4 MINUTES. THE…
- 2 Feb 2016
Intercostal, cracked
AFT ACCESSORY LT INTERCOSTAL IS CRACKED AT CANT 1510, OTBD OF SLIDE PLATFORM. INSTALLED NEW INTERCOSTAL PN 9917701-3 IAW SRM 51-30-05. ACFT IN BASE MX.
- 2 Feb 2016
Frame, worn
AIRCRAFT WAS IN BASE MX. FRAME AT FS 1510, BETWEEN LONGERON 28R & 28R IS WORN FROM CONTACT WITH TAIL CONE LOWER SECTION. REPAIRED FRAME IAW EA 257868.
- 1 Feb 2016
Cusp Web, corroded
AFT CARGO CORROSION ON BOTTOM SIDE OF RT CUSP, STATION 1287 - 1309. REPLACED CUSP WEB MEMBRANE AT STATION 1250 - 1309 IAW AARD 51-00-05, SRM 51-10-03, SRM…
- 22 May 2015
Uplock, leaking
EMERGENCY DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING CRUISE, A LOW HYD PRESS WARNING OCCURRED. FOUND LT MLG DOOR UPLOCK LEAKING. R & R UPLOCK.…
- 20 Aug 2014
Skin, cracked
TWO SKIN CRACKS AT STATION 1436 & STRINGER 3 RT. INSTALLED REPAIR DOUBLER IAW SRM 53-01-00.
- 20 Aug 2014
Skin, cracked
2.5 INCH CRACK ON LT SIDE ABOVE PACK RAM AIR. INSTALLED REPAIR DOUBLER IAW SRM 55-01-00.
- 19 Aug 2014
Former, cracked
LEFT WING LE NR 4 SLAT TRACK INBD FORMER IS CRACKED. INSTALLED LT WING NR 4 INBD FORMER DOUBLER IAW WORK CARD 57-98-05.
- 19 Aug 2014
Former, cracked
RIGHT WING LE NR 4 SLAT TRACK INBD FORMER IS CRACKED. INSTALLED RT WING NR 4 INBD FORMER DOUBLER IAW WORK CARD 57-98-06.
- 13 Jun 2014
Splice, burned
CREW REPORTED BOTH CABIN PRESS CONTROL INOPERATIVE. FLIGHT RETURNED & LANDED WITHOUT INCIDENT. PLACARDED BOTH PRESSURIZATION CONTROLLERS INOPERATIVE IAW MEL.…
- 10 Jun 2014
Power Supply, discharged
TAIL COMPARTMENT EMER LIGHTS INOPERATIVE. REPLACED POWER SUPPLY FOR TAIL COMPARTMENT EMER LIGHTS. OPERATIONS CHECKED NORMAL.
- 26 Mar 2013
Fitting, leaking
CENTER TANK - LEFT BATHTUB FITTING IS LEAKING AT STATION 870 LEFT SIDE OF KEEL BEAM BOX FORWARD OF THE WHEEL WELL. INSTALLED NEW FORWARD AND AFT LEFT BATHTUB…
- 13 Mar 2013
Structure, corroded
CORROSION AND SHEARED RIVET HEADS AT STATION 646 BETWEEN LONGERONS 30 AND 29 LEFT. CUT OUT CORROSION AND INSTALLED DOUBLER PER EA.
- 13 Mar 2013
Seat Track, corroded
CORROSION ON NUMBER 6 SEAT TRACK AT STATION 370 AROUND FASTENER HOLE FOR SIDEWALL SUPPORT. CUT OUT CORROSION AND PERFORMED STRAP DOUBLER REPAIR PER AARD…
- 11 Mar 2013
Cusp Web, corroded
CORROSION ON CUSP AT STATION 258 LEFT SIDE. REMOVED CORROSION AND INSTALLED DOUBLER PER AARD 53-20-00-16 AND SRM 51-30-00.
- 10 Mar 2013
Cusp Web, corroded
RIGHT CUSP FROM STATIONS 503 TO 598 CORRODED. INSTALLED CUSP SHEET PER AARD 51-00-05-1.
- 10 Mar 2013
Cusp Web, cracked
CUSP SHEET CRACKED BELOW NUMBER 6 SEAT TRACK FROM STATIONS 218 TO 237. INSTALLED NEW CUSP SHEET FROM STATIONS 218 TO 237 PER AARD 51-00-05-1.
- 9 Mar 2013
Longeron, cracked
FORWARD NUMBER THREE LONGERON LEFT AT STATION 160 CRACKED. INSTALLED NEW LONGERON SECTION PER SRM 53-02-00 FIGURE 18.
- 7 Mar 2013
Skin, dented
DENT WITH GOUGE AT STATION 179, LONGERON 30. INSTALLED DOUBLER PER SRM 53-04-03 FIGURE 4.
- 7 Mar 2013
Bracket, cracked
CRACK ON MOUNT BRACKET AT AFT END TIE-DOWN TRACK INTERCOSTAL, STATION 788 BETWEEN LONGERONS 28 AND 27 RIGHT. REMOVED AND INSTALLED NEW BRACKET PER SRM 51-30-05.
- 1 Mar 2013
Retainer, damaged
RUDDER, LEFT SIDE 6 SEAL RETAINER HOLES BORED OUT TO QUARTER INCH IN SIZE. ACCOMPLISHED BONDED REPAIR PER SRM 51-70-01A.
- 27 Feb 2013
Cusp Web, corroded
CORROSION ON AFT SERVICE DOOR SUBFLOOR UNDER AFT GIRT BAR SUPPORT BRACKET. REMOVED CORROSION AND INSTALLED DOUBLER PER AARD 53-20-00-16.
- 27 Feb 2013
Membrane, corroded
CORROSION ON SUB FLOOR UNDER G-1 GALLEY DRAIN PAN. REMOVED CORROSION AND INSTALLED DOUBLER PER AARD 53-20-00-16.
- 27 Feb 2013
Floorbeam, corroded
CORROSION ON FLOORBEAM AT STATION 160, RIGHT BUTTLINE 10. REMOVED CORROSION AND INSTALLED A SPLICE ANGLE REPAIR PER SRM 51-70-05-FIGURE 3 SHEET 7.
- 27 Feb 2013
Membrane, corroded
CORROSION ON SUB FLOOR AT STATION 160, RIGHT BUTTLINE 10 UNDER G1 INBOARD GALLEY MOUNT. REMOVED CORROSION AND INSTALLED DOUBLER PER AARD 53-20-00-16.
- 31 Mar 2011
Exciter, failed
MCO INFLIGHT TPA-ORD. CREW REPORTED LIGHTNING STRIKE TO RIGHT SIDE OF AIRCRAFT WITH RIGHT ENGINE SHUTDOWN (SINGLE ENGINE TIME 1 MINUTE). EMERGENCY DECLARED…
- 1 Jan 2011
Control Valve, leaking
YYC - CREW REPORTED LOSS OF HYDRAULIC PRESSURE. EMERGENCY DECLARED FLIGHT RETURNED YYC LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED RIGHT…
- 19 Aug 2009
Battery Pack, discharged
EMERGENCY LIGHTS IN SEATS INOPERATIVE. INSTALLED BATTERY PACK FOR EMERGENCY LIGHTS.
- 19 Aug 2009
Battery Pack, discharged
EMERGENCY LIGHTS IN SEATS INOPERATIVE. INSTALLED SERVICEABLE BATTERY PACK FOR EMERGENCY LIGHTS.
- 19 Aug 2009
Battery Pack, discharged
EMERGENCY LIGHTING IN SEATS INOPERATIVE. INSTALLED SERVICEABLE BATTERY PACK FOR EMERGENCY LIGHTING IN SEATS.
- 19 Aug 2009
Battery Pack, discharged
EMERGENCY LIGHTING IN SEATS INOPERATIVE. INSTALLED SERVICEABLE BATTERY PACK FOR EMERGENCY LIGHTING.
- 9 Jun 2009
Controller, inoperative
DFW - CREW REPORTED AIRCRAFT LOST PRESSURIZATION AND NOTICED THE CABIN ALTITUDE CLIMBING. DECLARED AND EMERGENCY AND DESCENDED, O2 MASKS DID NOT DEPLOY.…
- 26 Apr 2009
Battery Pack, discharged
LGA - CEILING EMERGENCY LIGHTS AT ROW 7 TO 11 INOPERATIVE. REPLACED BATTERY PACK AT ROW 8 FOR EMERGENCY LIGHTS.
- 6 Dec 2008
Bracket, corroded
LOWER CORNER BRACKET IN AFT CARGO AT STATION 1211 AND LONGERON 27 RIGHT CORRODED BEYOND LIMITS. REMOVED AND REPLACED BRACKET PER SRM 51-30-00.
- 6 Dec 2008
Bracket, cracked
MID CARGO DOOR UPPER FORWARD STOP BRACKET CRACKED. INSTALLED A SERVICEABLE BRACKET PER ESO 80174.
- 6 Dec 2008
Bracket, cracked
MID CARGO DOOR UPPER AFT STOP BRACKET CRACKED. INSTALLED SERVICEABLE BRACKET PER ESO80174.
- 6 Dec 2008
Frame, cracked
CRACK IN DOUBLER REPAIR AT BASE OF ACTUATOR CRADLE AT FRAME STATION 1485. INSTALLED SERVICEABLE DOUBLER PER AARD 53-10-00-33.
- 5 Dec 2008
Cargo Track, corroded
LEFT TIE DOWN TRACK IN AFT CARGO HAS CORROSION SEVERAL PLACES FROM STATION 1212 TO STATION 1117. REPLACED LEFT FORWARD TRACK FROM STATION 1212 TO STATION 1117.
- 4 Dec 2008
Bracket, corroded
CORROSION IN MID CARGO DOOR JAMB FORWARD LOWER CORNER FITTING. OLD BRACKET WAS REMOVED AND NEW BRACKET INSTALLED.
- 4 Dec 2008
Intercostal, cracked
FORWARD ENTRY DOOR THIRD FROM BOTTOM INTERCOSTAL CRACKED. REPAIRED PER AARD 52-10-00-3.
- 4 Dec 2008
Beam, cracked
FORWARD ENTRY DOOR, NUMBER 6 DOOR BEAM CRACKED. REPAIRED PER SRM 52-05-00 FIGURE 3.
- 3 Dec 2008
Beam, corroded
MID CARGO DOOR BEAM VERTICAL LEG CORRODED. INSTALLED 2 DOUBLERS PER AARD 53-10-00-3.
- 3 Dec 2008
Angle, corroded
CORROSION ON ANGLE FRAME 9 INCHES TO THE RIGHT OF AIRCRAFT CENTER LINE AT STATION 1380, LOWER AFT SIDE OF APU ENCLOSURE. REPAIR DOUBLER INSTALLED PER ESO…
- 3 Dec 2008
Angle, corroded
CORROSION IN LOWER "J" ANGLE AT STATION 1322 BETWEEN LONGERON 29 LEFT AND LONGERON 29 RIGHT. REPAIR DOUBLER INSTALLED PER AARD 53-10-00-17.
- 2 Dec 2008
Cusp Web, corroded
CORROSION ON LOWER SIDE OF RIGHT CUSP STATION 1200. INSTALLED REPAIR PER AARD 53-20-00-16.
- 2 Dec 2008
Longeron, cracked
STATION 160 AT LONGERON LEFT 3 IS CRACKED AT FASTENER. INSTALLED REPLACEMENT SPLICE LONGERON AT STATION 160 AT LEFT 3 PER SRM 53-02.
- 2 Dec 2008
Bracket, corroded
BRACKET CORRODED, BETWEEN LONGERON 27 AND 28 RIGHT AT AFT CARGO DOOR CUTOUT STATION 1210. REMOVED BRACKET AND INSTALLED SERVICEABLE BRACKET PER SRM 51-01-00.
- 28 Nov 2008
Angle, corroded
PLOW ANGLE CORRODED IN AFT CARGO STATION 1338. INSTALLED A SERVICEABLE ANGLE PER SRM 53-01.
- 28 Nov 2008
Seat Track, broken
NUMBER 4 SEAT TRACK TANG BROKEN FROM STATION 928 TO 930. INSTALLED REPAIR PLUG.
- 28 Nov 2008
Seat Track, broken
NUMBER 4 SEAT TRACK TANG BROKEN FROM STATION 916 TO 919. INSTALLED REPAIR PLUG.
- 28 Nov 2008
Fitting, cracked
VAULT DOOR BELL CRANK FITTING CRACKED. INSTALLED A SERVICEABLE FITTING.
- 26 Nov 2008
Cusp Web, corroded
CORROSION ON LOWER SIDE OF RIGHT CUSP STATION 560. REPAIRED PER AARD 53-20-00-16.
- 26 Nov 2008
Mount, corroded
G2 GALLEY INBOARD GALLEY MOUNT CORRODED IN HOLE AND TOP. NEW GALLEY MOUNT WAS INSTALLED PER SRM 51-01.
- 26 Nov 2008
Fitting, cracked
DOOR STOP BACK UP FITTING IS CRACKED AT LOWER FASTENER ON LEFT SIDE OF VAULT DOOR OPENING, LOWER FITTING. INSTALLED SERVICEABLE DOOR STOP FITTING PER SRM 51-01.
- 26 Nov 2008
Mount, corroded
CORROSION ON INBOARD AFT NUMBER 2 GALLEY MOUNT. INSTALLED SERVICEABLE GALLEY MOUNT.
- 25 Nov 2008
Cusp Web, corroded
RIGHT CUSP CORRODED STATION 845. REPAIRED PER AARD 53-20-00-10.
- 19 Sep 2008
Lens, inoperative
DFW EMERGENCY LIGHT BETWEEN RT SEAT ROWS 6 AND 7 MISSING LENS. REPLACED LENS FOR EMERGENCY LIGHT BETWEEN RT SEAT ROWS 6 AND 7. SYSTEM GROUND CHECKED NORMAL OPS.
- 19 Sep 2008
Shroud, broken
DFW EMERGENCY LIGHT AT SEAT 22D HAS BROKEN SHROUD. REPLACED SHROUD FOR EMERGENCY LIGHT AT SEAT 22D. SYSTEM GROUND CHECKED NORMAL OPS.
- 19 Sep 2008
Battery Pack, inoperative
DFW EMERGENCY LIGHTS AT AISLE OVERHEAD SEAT ROWS 22 TO 28 INOPERATIVE. REPLACED BATTERY PACK AT STATION 1100 FOR EMERGENCY LIGHTS AT AISLE OVERHEAD SEAT ROWS…
- 19 Sep 2008
Battery Pack, inoperative
DFW EMERGENCY LIGHT EXIT SIGNS AT AFT OVERWING LT AND RT INOPERATIVE. REPLACED BATTERY PACK AT STATION 900 FOR EMERGENCY LIGHT EXIT SIGNS AT AFT OVERWING LT…
- 19 Sep 2008
Lamp, inoperative
DFW EMERGENCY LIGHT AT SEAT 12D INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT SEAT 12D. SYSTEM GROUND CHECKED NORMAL OPS.
- 31 Jan 2007
Module, inoperative
LGA - FOUND AFT EMERGENCY EXIT FLOOR LIGHT FROM AFT MODULE AB54 INOPERATIVE. REPLACED CONTROL MODULE AND BATTERY FOR AFT EMERGENCY EXIT FLOOR LIGHT FROM AFT…
- 24 Jan 2007
Switch, inoperative
LGA INFLIGHT T1142/24JAN - EN ROUTE TO LGA EXPERIENCED PRESSURIZATION LOSS. INITIATED EMERGENCY DESCENT AND PASSENGER OXYGEN MASKS DROPPED WITH EXCEPTION OF…
- 6 Dec 2006
Blades, damaged
ORD - ON TAKE OFF, AIRCRAFT YAWED TO THE RIGHT. FLIGHT ATTENDANTS REPORTED LOUD PBP BEFORE FLIGHT CREW ABORTED TAKEOFF. BRAKE TEMPERATURES DID NOT EXCEED 150…
- 30 Oct 2004
Battery Pack, inoperative
DURING EMERGENCY LIGHT CHECK OVERHEAD EMERGENCY LIGHTS AT STA 982 RT AND LT, STA 1039 LT AND STATION 1096 RT AND LT WERE INOPERATIVE. REPLACED BATTERY PACK AT…
- 15 Feb 2004
Light, inoperative
DFW - FORWARD EMERGENCY LIGHT ARROW INOPERATIVE. REPLACED FORWARD EMERGENCY ARROW LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 15 Feb 2004
Sign, unserviceable
DFW - LEFT HAND EMERGENCY LIGHT EXIT MARKER AT FORWARD OVERWING EXIT UNREADABLE. REPLACED LEFT HAND EMERGENCY LIGHT EXIT MARKER AT FORWARD OVERWING EXIT.…
- 15 Feb 2004
Sign, unserviceable
DFW - EMERGENCY LIGHT EXIT MARKER AT RIGHT AFT OVERWING EXIT UNREADABLE. REPLACED EMERGENCY LIGHT EXIT MARKER AT RIGHT AFT OVERWING EXIT. SYSTEM GROUND…
- 22 Sep 2003
Battery Pack, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTING WAS INOPERATIVE AT THE OVERWING EXIT. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL…
- 27 May 2002
Duct, damaged
ORD - FLT 1511 - EN ROUTE ORD-PSP - 15 MINUTES AFTER TAKEOFF TAIL COMPARTMENT HIGH TEMPERATURE LIGHT ILLUMINATED. FOLLOWED PROCEDURES AND LIGHT EXTINGUISHED…
- 26 May 2002
Sensor, malfunctioned
ORD - FLT 1381 - EN ROUTE ORD-SAT, DURING CLIMB-OUT, THE TAIL COMPARTMENT TEMPERATURE HIGH WARNING LIGHT ILLUMINATED. CHECKLIST WAS RUN AND LIGHT…
- 4 May 2002
Splice, damaged
DFW - DURING OVERNIGHT MAINTENANCE, AFT AIRSTAIR EMERGENCY EXIT LIGHT LEFT SIDE SIDEWALL INOPERATIVE. REPAIRED AFT AIRSTAIR EMERGENCY EXIT SIDEWALL LIGHT WIRE…
- 7 Apr 2002
Battery, discharged
ORD - DURING OVERNIGHT MAINTENANCE, RIGHT FORWARD HALF OF CABIN EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT BATTERY. SYSTEM GROUND…
- 24 Mar 2002
Battery, discharged
DFW - DURING OVERNIGHT MAINTENANCE, FIRST CLASS AND HALF OF COACH EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT BATTERIES. SYSTEM GROUND…
- 18 Jul 2001
Battery Pack, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, FIRST CLASS OVERHEAD EMERGENCY EXIT LIGHTING INOPERATIVE. REPLACED BATTERY PACK TO FIRST CLASS EMERGENCY EXIT LIGHTS.…
- 17 Jul 2001
Generator, defective
MSP - FLT 1103 - EN ROUTE ORD-SEA - LEFT GENERATOR TRIPPED IN FLIGHT. RESET AND TRIPPED AGAIN AFTER FIVE MINUTES. AIR INTERRUPTED AND LANDED MSP WITHOUT…
- 18 Apr 2001
Frame, chafed
TUL - FOUND STATION 1401 L21R FRAME WORN FROM INCORRECT LINE STAND OFF. BLENDED OUT WEAR AREA. TREATED, PRIMED AND INSTALLED DOUBLERS PER 53-03 P5 FLT 32…
- 18 Apr 2001
Skin, damaged
TUL - FOUND TEMPORARY REPAIR INSTALLED AT LONGERON 21R STATION 500. INSTALLED DOUBLER PER SRM 53-04 FIG 38, SHEET 24 AND ESO 80559 DATED 4/10/2001. (M)
- 17 Apr 2001
Frame, cracked
TUL - FOUND CRACK AT BASE OF CANT FRAME 1485 RIGHT JUST OUTBOARD OF STAIR ACT. REMOVED DAMAGE (CRACK), AND INSTALLED WEB SPLICE PER ESO 80559 DATED 2-23-01. (M)
- 14 Apr 2001
Floorbeam, damaged
TUL - FOUND RIGHT AFT LAVATORY STATION 1338 FLOORBEAM DAMAGED, CORROSION AROUND FASTENER HOLE. REPAIRED FLOORBEAM PER SRM 53-05 PART 1. (M)
- 13 Apr 2001
Skin Panel, damaged
TUL - FOUND VERTICAL STAB SKIN WORN 50 PERCENT THROUGH BY DAMAGED SEAL BRACKET JUST AFT OF RIGHT ROLLER TRACK. PART REPLACEMENT. REMOVED AND REPLACED STAB…
- 12 Apr 2001
Seat Track, corroded
TUL - FOUND CORROSION ON SEAT TRACK 6 AT STATION 215. REMOVED CORRODED SECTION AND SPLICED IN NEW SEAT TRACK FROM STATION 215 TO 303 PER 53-05 PT 1 FIG 4F. (M)
- 12 Apr 2001
Skin, dented
TUL - FOUND DENT WITH SHARP CREASES DOWN INSIDE, LEFT FUSELAGE STATION 290 L22L, MARKED. INSTALLED DOUBLER PER SRM 53-04 FIG 38 SHEET 24. (M)
- 9 Apr 2001
Seat Track, corroded
TUL - FOUND CORROSION AND WEAR ON SEAT TRACK NR 1 FROM 1118-1121. INSTALLED SEAT TRACK PLUG STATION 1110-1123 PER SRM 53-05 PART 1, FIG 4A. APPLIED COAT OF…
- 19 Feb 1999
Oven, smoking
BOS - FLT 449 - EN ROUTE BOS-MIA, DURING CLIMB-OUT FLIGHT ATTENDANT REPORTED LIGHT SMOKE IN CABIN. SMOKE STARTED IN BACK OF THE AIRCRAFT AND WORKED FORWARD,…
- 8 Jan 1997
Connector, loose
DFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS AT AFT PART OF MAIN CABIN INOPERATIVE. RESECURED LOOSE EMERGENCY FLOOR LIGHT STRIP CONNECTORS AT AFT PART…
- 16 Sep 1995
Eel Strip, defective
DFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS AT AFT CABIN INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT STRIP AT AFT CABIN. SYSTEM GROUND CHECKED NORMAL…