N429US
Boeing 737-4B7 FAA →
reservations
earlier registrations
1 past record
service difficulty reports
37 reports
- 3 Jul 2003
Charger, failed
MAINTENANCE REPORTED THE FORWARD FLOOR PROXIMITY EMERGENCY EXIT LIGHT AT SEAT ROW 11, LEFT SIDE, ALONG WITH THE FLOOR PATH EMERGENCY LIGHTS FROM SEAT ROWS 7…
- 21 Nov 2002
Warning Light, illuminated
PBI - FLT 1246 - ON CLIMB-OUT FROM MIA, EN ROUTE TO PIT, THE NR 2 ENGINE OIL FILTER BYPASS LIGHT ILLUMINATED. ALL OTHER ENGINE INDICATIONS WERE NORMAL. CREW…
- 8 Sep 2001
Downlock Sensor
SDF - FLT 1144 - IN PREPARATION FOR LANDING AT SDF, THE CREW RECEIVED A RIGHT MAIN LANDING GEAR UNSAFE LIGHT DURING GEAR EXTENSION. CAPTAIN ACCOMPLISHED A…
- 28 Jun 2001
Skin, cracked
CLT - FOUND SKIN CRACKED 1.5 INCH, BS 727D, STRINGER 23R. DAMAGE REMOVED, INSTALLED REPAIR DOUBLER PER TYPICAL REPAIR 53-60-03. (M)
- 27 Apr 2001
Bulkhead, cracked
CLT - FOUND PRESSURE WEB WITH 5 CRACKS, TWO .250 INCH, TWO .150 INCH AND ONE .100 INCH, BS 178, WL 195, 198, 201.5, 206.6; LBL 5 TO RBL 7. DAMAGE CUTOUT,…
- 15 May 2000
Skin, cracked
CLT - FOUND SKIN CRACKED .250 INCH, EXT SKIN AFT ENTRANCE DOOR LOWER HINGE UPPER CUTOUT. INSTALLED DOUBLER PER SRM 52-00-01. (M)
- 11 May 2000
Floorbeam, corroded
CLT - FOUND FLOORBEAM CORRODED 2 INCHES BY 70 INCHES, FS 328 BETWEEN RBL 56 AND RBL 14. INSTALLED NEW T-CAP PER SRM 53-10-51. CORROSION LEVEL 2. (M)
- 11 May 2000
Frame, cracked
CLT - FOUND FRAME CRACKED 2 INCHES, BS 601 RT, WL 202. INSTALLED STIFFENER AND FILLER PER EA 67119. (M)
- 11 May 2000
Frame, cracked
CLT - FOUND FRAME CRACKED 1 INCH, BS 296, STRINGER 17R FORWARD SERVICE DOOR CUTOUT. INSTALLED DOUBLER AND FILLER ANGLE PER SRM 51-70-11. (M)
- 11 May 2000
Frame, cracked
CLT - FOUND FRAME CRACKED .25 INCH, BS 440, STRINGER 8R. INSTALLED DOUBLER PER TR 53-10-14. (M)
- 11 May 2000
Frame, cracked
CLT - FOUND FRAME CRACKED .25 INCH, BS 787, STRINGER 8L. INSTALLED DOUBLER PER TR 53-10-14. (M)
- 11 May 2000
Frame, cracked
CLT - FOUND FRAME CRACKED .25 INCH, BS 747, STRINGER 8L. INSTALLED REPAIR DOUBLER PER TR 53-10-14. (M)
- 11 May 2000
Frame, cracked
CLT - FOUND FRAME CRACKED .25 INCH, BS 440, STRINGER 8L. INSTALLED DOUBLER PER TR 53-10-14. (M)
- 11 May 2000
Floor Support, corroded
CLT - FOUND FLOOR SUPPORT BEAM CORRODED 1 INCH BY 2 INCH, 9 INCHES INBOARD OF AFT ENTRY DOOR STATION 986.5. INSTALLED NEW T-CAP PER TR 53-60-01. CORROSION…
- 4 May 2000
Skin, cracked
CLT - FOUND SKIN CRACKED .25 INCH, OUTBOARD EDGE OF PANEL 5727L CUTOUT. INSTALLED DOUBLER PER TR 54-30-07. (M)
- 1 May 2000
Floor Support, corroded
CLT - FOUND FLOOR SUPPORT CORRODED, RIGHT AFT DOOR Z-ANGLE. LEVEL 1 CORROSION. INSTALLED DOUBLER PER SRM 51-70-11. (M)
- 1 May 2000
Floorbeam, corroded
CLT - FOUND BEAM CRACKED 2 INCHES BY 55 INCHES, NUMEROUS CORROSION LEVEL 2, FLOORBEAM AT FS 344 BETWEEN RBL 11 AND LBL 44. INSTALLED NEW T-CAP AND SPLICE PER…
- 1 May 2000
Angle, corroded
CLT - FOUND Z-ANGLE CORRODED .250 INCH BY .250 INCH, FORWARD SERVICE DOOR JAM. INSTALLED NEW Z-ANGLE PER SRM 53-10-13. (M)
- 1 May 2000
Frame, cracked
CLT - FOUND FRAME CRACKED 2 INCHES, BS 601 LT AT WL 202. INSTALLED DOUBLER PER EA 67119 AND TR 53-62-01. (M)
- 1 May 2000
Bulkhead, cracked
CLT - FOUND WEB CRACKED 1 INCH, 178 BULKHEAD, LBL 5.7 AND WL 202 AND 199. INSTALLED DOUBLER PER TR 53-10-07 REV A. (M)
- 28 Apr 2000
Frame, cracked
CLT - FOUND FRAME CRACKED .25 INCH, BS 727D, STRINGER 8 RT. INSTALLED DOUBLER PER TR 53-10-14. (M)
- 28 Apr 2000
Frame, cracked
CLT - FOUND FRAME CRACKED .25 INCH, BS 727D, STRINGER 8 LEFT. INSTALLED DOUBLER PER TR 53-10-14. (M)
- 28 Apr 2000
Frame, cracked
CLT - FOUND FRAME CRACKED .25 INCH, BS 380 STRINGER 8 RIGHT. INSTALLED DOUBLER PER TR 53-10-14. (M)
- 28 Apr 2000
Frame, cracked
CLT - FOUND FRAME CRACKED .25 INCH, BS 380 STRINGER 8 LEFT. INSTALLED DOUBLER PER TR 53-10-14. (M)
- 28 Apr 2000
Frame, cracked
CLT - FOUND FRAME CRACKED .25 INCH, BS 400 STRINGER 8 LEFT. INSTALLED DOUBLER PER TR 53-10-14. (M)
- 28 Apr 2000
Frame, cracked
CLT - FOUND FRAME CRACKED .25 INCH, BS 867, STRINGER 8 LEFT. INSTALLED DOUBLER PER TR 53-10-14. (M)
- 28 Apr 2000
Frame, cracked
CLT - FOUND FRAME CRACKED .25 INCH, BS 907 STRINGER 8 RIGHT. INSTALLED DOUBLER PER TR 53-10-14. (M)
- 21 Mar 2000
Skin, cracked
CLT - FOUND FUSELAGE SKIN CRACKED 1 INCH, LEFT SIDE FUSELAGE AFT OF LT WING BODY FAIRING. REPAIRED DOUBLER AND FILLER PER TR 53-60-03. (M)
- 2 Feb 2000
Circuit Breaker, tripped
BOS - FLT 2030 - CREW RECEIVED A GEAR INDICATION WARNING FOR THE NOSE GEAR WHILE PREPARING TO LAND AT BOS. CAPTAIN ACCOMPLISHED A FLYBY THE TOWER TO VERIFY…
- 18 Dec 1999
Skin, cracked
TPA - DURING AC-5 CHECK VISUAL INSPECTION, FOUND THE DOOR SKIN BENT AND CRACKED JUST ABOVE LOWER HINGE CUTOUT. REPAIRED PER EA 66130. (M)
- 15 Nov 1998
Light, inoperative
TPA - MAINTENANCE FOUND THE FORWARD ENTRY EGRESS EMERGENCY LIGHT AND THE RIGHT AFT FUSELAGE EGRESS EMERGENCY LIGHT INOP. MAINTENANCE REMOVED AND REPLACED THE…
- 19 Oct 1998
Skin, cracked
TPA - DURING C-2 CHECK VISUAL INSPECTION, FOUND A 1.75 INCH CRACK ELEV STATION 51-54 AT STAB STATION 67.54 HORIZONTAL STABILIZER SKIN. CUTOUT CRACK AND…
- 19 Oct 1998
Skin, cracked
TPA - DURING C-2 CHECK VISUAL INSPECTION, FOUND A 1.75 INCH CRACK ELEVATOR STATION 81.54 AT STAB STATION 67.54 HORIZ STAB SKIN. CUTOUT CRACK AND INSTALLED…
- 8 Jan 1997
Battery Pack, discharged
CLE - MX FOUND THE FORWARD SERVICE DOOR EMERGENCY LIGHTS INOP. MAINTENANCE REMOVED AND REPLACED THE BATTERY PACK. OPS CHECK GOOD. (M)
- 25 Jul 1996
Coalescer Bag, failed
DEN-PIT - FLT 132 - CREW REPORTED A SMOKE TYPE SMELL IN THE COCKPIT AND FORWARD CABIN. SMELL IS STRONGEST IN THE COCKPIT. HAPPENS AT DIFFERENT FLIGHT…
- 25 Jun 1996
Fan, failed
MCO - FLT 1981 - ON DESCENT TO MCO, CREW NOTICED A VERY STRONG ODOR. SMELLED LIKE HYDRAULIC FLUID ON A HOT DUCT. NO EMERGENCY WAS DECLARED AND THE FLIGHT…
- 20 Jul 1995
Circuit Breaker, failed
LGA - FLT 2235 - THE 'NOSE GEAR UNSAFE' LIGHT ILLUMINATED WHEN THE POWER WAS BROUGHT TO IDLE. VISUALLY VERIFIED GEAR POSITION AND PERFORMED TOWER FLYBY.…