N426XJ
Saab-Scania SAAB 340B standard FAA →
earlier registrations
1 past record
service difficulty reports
73 reports
- 10 Oct 2014
Guide, chafed
SPRINGS FOUND CHAFING INTO SPRING GUIDES ENOUGH TO PROHIBIT PROPER CABLE TENSION ADJUSTMENT. THIS DISCREPANCY OCCURRED UNDER NORMAL WEAR AND UTILIZATION. WALL…
- 21 Sep 2010
Acm, seized
DURING TAXI OPERATIONS WITH RT ENGINE FEATHERED AND RT HP ON, NOTED, A SMELL SIMILAR TO MATCHES. NOT LONG AFTER NOTICING THE SMELL, AIR GOT EXTREMELY HOT. F/A…
- 11 Sep 2010
Battery Pack, failed
EMERGENCY LIGHTING BATTERY PACK 24LN FAILED OPS TEST. REPLACED EMERG BATTERY PACK 24LN, PN 3301-51, SN OFF 2102, SN ON 1370, IAW AMM 33-50-10-04-1.
- 11 Sep 2010
Battery Pack, failed
EMERGENCY LIGHTING BATTERY PACK, 23LN FAILED OPS TEST. R & R EMERGENCY POWER SUPPLY AT 23LN PN 330-51 ON/OFF SN ON 2103 OFF 2166 IAW AMM 33-50-10-04-1.
- 31 Aug 2010
Seat Track, corroded
CARGO CENTER AISLE SEAT TRACK CORROSION: BL 0, STA 622-686. REPAIRED IAW S53060.
- 31 Aug 2010
Seat Track, corroded
CENTER AISLE SEAT TRACK CORROSION: LBL 18.3, STA 297-308. REPAIRED IAW S53060.
- 31 Aug 2010
Seat Track, corroded
CTR AISLE SEAT TRACK CORROSION: BL 0, STA 297-307. REPAIRED IAW S53060.
- 31 Aug 2010
Frame, unknown
LOWER FRAME, UPPER FLANGE, STA 294 LBL 18 TO BL0. REPAIRED IAW S53776.
- 31 Aug 2010
Frame, unknown
LOWER FRAME, UPPER FLANGE, STA 294 RBL 18.3. REPAIRED IAW S53108.
- 9 Oct 2009
Power Supply, no test
DURING TASK CARD 335003 POWER SUPPLY 20LN FAILED CAPACITY CHECK. REMOVED AND REPLACED 20LN POWER SUPPLY IAW SAAB AMM 33-50-10-04-1.
- 25 Jul 2009
Skin, corroded
NOTED 20 SPOTS OF CORROSION UNDER WEAR STRIP NR 9 ON LT FLAP UPPER SKIN PANEL 541AT. REPAIRED IAW EO S57263.
- 21 Jul 2009
Skin, dented
2 DENTS WERE NOTED ON RT ELEVATOR, ONE LWR AND ONE UPPER. REPAIRED IAW EO S51031.
- 21 Jul 2009
Skin, dented
1 DENT WAS NOTED ON LT ELEVATOR ON LWR SKIN. REPAIRED IAW EO S51031.
- 2 Feb 2009
Duct, defective
DURING CLIMBOUT OF PIB CREW NOTICED FLAMES COMING FROM THE RT INTAKE AREA, TURNED OFF ENG HEAT AND FLAMES EXTINGUISHED. RETURNED, AND REPLACED LOWER DUCT.
- 22 Jul 2008
Acm, odor
IN CRUISE AT 17K FT SMELLED BURNING ODOR AND SAW SMALL METAL PARTICLES BLOWING OUT OF VENTS. REPLACED RT ACM. (S)
- 23 Oct 2007
Tire, missing
CREW NOTED RT OB TIRE WAS MISSING ON POST FLIGHT. REMOVED AND REPLACED RT LOWER MAIN LANDING GEAR SUB ASSEMBLY IAW TASK CARD 3211-301. MLG SUB ASSEMBLY PN…
- 23 Aug 2007
Unknown, odor
CREW REPORTED IN FLIGHT BURNING ODOR IN FLIGHT DECK AT HIGH POWER SETTINGS. COMPLETED OPERATIONAL CHECK OF AUTO AND MANUAL TEMP CONTROL IAW TASK CARD…
- 22 Jul 2007
Smoke Detector, malfunctioned
LAVATORY SMOKE LIGHT ILLUMINATED ON MASTER WARNING IN FLIGHT. COMPLETED QRH. NO EVIDENCE OF SMOKE OR FIRE FOUND IN LAVATORY. LIGHT REMAINED ON UNTIL SHUTDOWN.…
- 27 Jun 2007
Light, broken
CABIN FLOOR PROXIMITY EMERGENCY LIGHT STRIP WAS INOPERATIVE SEATS 7A-9A. FOUND EMERGENCY LIGHT STRIP BROKEN. REMOVED AND REPLACED INOPERATIVE EMERGENCY LIGHT…
- 16 Oct 2006
Unknown, odor
CREW NOTED STRONG ELECTRICAL ODOR, ONLY NOTICABLE IN THE FLIGHT DECK. WINDSHIELD HEAT IS SUSPECTED. RAN AIRCRAFT FOR 20 MINUTES WITH ALL ELECTRICAL ON, ALL…
- 16 Oct 2006
Wire Harness, odor
INTENSE SULFUR BURNING SMELL IN FLIGHT DECK AND CABIN ON APPROACH. GROUND CREW SMELLED INTENSE ODOR WHEN OPENING CARGO BIN. FOUND SEVERAL CHAFED, BURNT,…
- 28 Sep 2006
Skin, damaged
DURING 2 YEAR CHECK IN BNA FOUND RT ELEVATOR LOWER SURFACE HAS COMPOSITE DAMAGE APPROXIMATELY 8 INCHES INBOARD OF THE MID HINGE POINT. THE DAMAGE HAS BEEN…
- 26 Jul 2006
Seal, failed
CREW REPORTED THAT THEY SHUT DOWN THE RIGHT ENGINE INFLIGHT AND DECLARED EMERGENCY. ABOUT 15 MILES OUT OF MSP, CREW FELT A VIBRATION. WHILE LOOKING OVER THE…
- 12 May 2006
Battery Pack, inoperative
FAILED CAP CHECK PER BFGOODRICH CMM WO 409092. REPLACED BATTERY PACK.
- 21 Mar 2006
Frame, chafed
DURING N4K CHECK IN BNA, FOUND NR 1 NACELLE, FORWARD FRAME AT NS 197 IS CHAFED OUT OF LIMITS ON THE INBOARD SIDE. THE DAMAGE HAS BEEN REPAIRED IAW MESABA…
- 21 Mar 2006
Nozzle, chafed
DURING N4K CHECK IN BNA, FOUND LT IPD IS CHAFED AND MESABA EO NR S54133 HAS BEEN INSTALLED. REF: EAMS WORK ORDER 213667 TASK 4509.
- 21 Mar 2006
Nozzle, chafed
DURING N4K CHECK IN BNA, FOUND RT IPD IS CHAFED AND MESABA EO#S54133 HAS BEEN INSTALLED. REF: EAMS WORK ORDER 213667 TASK 4508.
- 23 Jun 2005
Battery, failed
BATTERY FAILED CAPACITY CHECK.
- 23 Jun 2005
Battery, discharged
BATTERY FAILED CAP CHECK,
- 23 Jun 2005
Battery, discharged
BATTERY FAILED CAP CHECK,
- 19 May 2005
Module, malfunctioned
THE CREW REPORTED THAT THE RT INTAKE HEAT SYSTEM WAS CYCLING AND A SLIGHT BURNT SMELL ASSOCIATED WITH THE INTAKE HEAT BEING ON. RETURNED TO DTW. REPLACED…
- 24 Nov 2004
Fitting, corroded
DURING 4Y/2Y INSPECTION IN BNA, COCKPIT WALL AT LBL 10.5, T-SECTION IS CORRODED. DAMAGE WAS REPAIRED IAW MESABA EO S53264. AIRCRAFT RETURNED TO SERVICE…
- 24 Nov 2004
Seat Track, corroded
DURING 4Y/2Y INSPECTION IN BNA, SEAT TRACK FLANGE AT FS 294, AT BL 0 IS CORRODED. CORROSION ON SEAT TRACK IS WITHIN LIMITS IAW SRM 53-70-60 AFTER REMOVED.…
- 24 Nov 2004
Seat Track, corroded
DURING 4Y/2Y INSPECTION IN BNA, SEAT TRACK I/B FLANGE AT FS 294 AND LBL 18.3 IS CORRODED OUT OF LIMITS AND WAS REPAIRED IAW SRM 53-70-60 AND MESABA 30 53079.…
- 24 Nov 2004
Web, corroded
DURING 4Y/2Y INSPECTION IN BNA, FLOOR WEB P/N 7253721-389 CORRODED OUT OF LIMITS AT FS 294 AT BL 0 & LBL 10.0. DAMAGE WAS REPAIRED IAW SRM 53-70-30.
- 24 Nov 2004
Flange, corroded
DURING 4Y/2Y INSPECTION IN BNA, FLOOR FLANGE IS CORRODED OUT OF LIMITS BETWEEN FS 272 & FS 288 AT LBL 30. FLANGE WAS REMOVED AND REPLACED.
- 20 Aug 2004
Thermister, malfunctioned
LT INTAKE ILLUMINATED IN FLIGHT. QRH COMPLETED, NOTIFIED DISPATCH/MECHANIC. LT AC GEN OPS OK, LT. APPEARS TO CYCLE EVERY 2 MINUTES OR LESS. AIR RETURN TO DTW.…
- 14 May 2004
Oxygen Mask, leaking
ON TAXI OUT THE O2 DEPLETED FROM 500 TO 50 RAPIDLY AND O2 LIGHT ILLUMINATED. THE MASK SEEM TO BE HOLDING PRESSURE. SERVICED O2 TO 1600PSI. AFTER 20MIN O2 BLED…
- 18 Apr 2004
Light, malfunctioned
EMERGENCY LIGHTS - UNARMED CAUTION LIGHT CAME ON IN FLT, EMERGENCY LIGHTS CAME ON IN CABIN. CYCLED SWITCH FROM OFF TO ARMED AND RESET C/B L7 AND L8 NEITHER…
- 2 Feb 2004
Weu, malfunctioned
CREW REPORTED RT ESS BUSS LIGHT ON AND THE RT AC GENERATOR CAUTION LIGHT ON. AIR RETURN TO MSP. REMOVED ESS BUSS CAUTION LIGHT ON (EQUIP OFF THIS BUSS SEEMS…
- 24 Jan 2004
Valve, failed
DURING FLIGHT, RIGHT AIR VALVE LIGHT INFLIGHT, RAN QRH AND NO FIX. AIR RETURN TO MSP. MAINTENANCE REPLACED ANTI ICE VALVE PER 75-00-00, OPS CHECKS GOOD PER…
- 13 Aug 2003
Connector, loose
DURING FLIGHT NR 3260, RT MLG DOWN/LOCK INDICATION INOPERATIVE. RT MAIN GEAR LIGHTS INOP WHEN GEAR SELECTED DOWN, RAN QRH TRANSIT HANDLE LIGHT WAS OUT LIGHT…
- 8 May 2003
Motor, failed
DURING FLIGHT 2786 SMOKE FILLED CABIN WITH SUPP A/C ON. NO PAX BOARDED AT THIS TIME. SMOKE FILLED CABIN WITH SUPP AC ON. SHUT SUPP AC OFF AND SMOKE STOPPED.…
- 8 Dec 2002
Frame, corroded
DURING 4K INSPECTION IN CWA, FRAME TIP PROFILES FWD AND AFT HAVE CORROSION. MAINTENANCE REPAIRED PROFILES IAW S53102, RELEASE DATE 12/10/02.
- 8 Dec 2002
Web, corroded
DURING 4K-INSPECTION IN CWA, WEBBING AT STA 288 AND 294 HAVE CORROSION. MAINTENANCE REMOVED AND REPLACED WEBBING. A/C RELEASE DATE 12/10/02.
- 5 Mar 2001
Scissors, corroded
FOUND DURING C-CHECK, LT MLG LEG HAS CORROSION IN THE UPPER SCISSOR LINK BORE, SEE IPM-12 FOR WORK ACCOMPLISHED ON LT MLG. PERFORMED EXTENSION AND RETRACTION…
- 5 Mar 2001
Scissors, corroded
FOUND DURING C-CHECK , IN NASHVILLE TN. RT MLG LEG HAS CORROSION AT UPPER SCISSOR LINES BORE. MAINTENANCE REMOVED RH MLG LEG, INSTALLED RH MLG LEG. INSTALLED…
- 2 Mar 2001
Shield, delaminated
FOUND DURING C-CHECK, IN NASHVILLE, TN RT ICE SHIELD 3RD FROM BOTTOM DELAMINATED AT UPPER EDGE AND HAS 2 GROUPS OF DENTS. MAINTENANCE REMOVED RH ICE SHIELD,…
- 2 Mar 2001
Duct, cracked
FOUND DURING C-CHECK, IN NASHVILLE, TN. LT ENGINE COWL DUCT IS CRACKED. MAINTENANCE STOP DRILLED CRACK, FABRICATED DOUBLER. NO CRACKS NOTED IAW FFVNDT006.…
- 2 Mar 2001
Hinge, cracked
FOUND DURING C-CHECK, IN NASHVILLE, TN. LT ENGINE HINGE COWL 453BR NACA DUCT IS CRACKED. MAINTENANCE STOPPED DRILLED CRACK, FABRICATED DOUBLER REF…
- 1 Mar 2001
Skin, chafed
FOUND DURING C-CHECK, IN NASHVILLE, TN. RT FLAP UPPER SURFACE PANEL 641AT IS CHAFED AFT OF THE FORWARD IB EXHAUST COWLING CHAFE STRIP. MAINTENANCE SMOOTHED…
- 1 Mar 2001
Seat Track, corroded
FOUND DURING C-CHECK, IN NASHVILLE, TN. GALLEY SEAT TRACK HAS SEVERAL AREAS OF CORROSION. SEAT TRACK AND PROFILE CORRODED BEYOND LIMITS. LOCATED AND DRILLED…
- 1 Mar 2001
Floorboard, corroded
FOUND DURING C-CHECK, IN NASHVILLE,TN. FLOORBOARD FLANGE AT FS 272 FOR FLOOR PANEL 122CZ HAS CORROSION. MAINTENANCE BLENDED OUT CORROSION, NEGLIGIBLE MATERIAL…
- 1 Mar 2001
Floor Panel, corroded
FOUND DURING C-CHECK, NASHVILLE, TN. FOUND FLOOR PANEL FLANGE 122CZ BETWEEN FS STA 272.0 AND 288.0 HAS CORROSION. MAINTENANCE BLENDED OUT CORROSION, MATERIAL…
- 1 Mar 2001
Web, corroded
FOUND DURING C-CHECK, IN NASHVILLE, TN. SEVERAL AREAS OF CORROSION ON WEB STA 288.TO STA 294. MAINTENANCE BLENDED OUT CORROSION, WEB CORRODED BEYOND LIMITS.…
- 1 Mar 2001
Floor Support, corroded
FOUND DURING C-CHECK, IN NASHVILLE TN. CORROSION ON RT FLOOR SUPPORT FLANGE AT RBL 33, FS 595, MAINTENANCE REMOVED CORROSION , TREATED W ALODINE 1200.…
- 1 Mar 2001
Floor Support, corroded
FOUND DURING C-CHECK, IN NASHVILLE, TN. CORROSION ON RT FLOOR SUPPORT FLANGE, AT RBL 33 FROM FS 500 THRU STA 535. MAINTENANCE REMOVED CORROSION, TREATED W/…
- 1 Mar 2001
Seat Track, corroded
FOUND DURING C-CHECK, IN NASHVILLE, TN. LT FLANGE CORRODED ON SEAT TRACK AT BL.0 FROM FUSELAGE STA 294 TO STA 500. MAINTENANCE REMOVED CORROSION, TREATED WITH…
- 1 Mar 2001
Floor Support, corroded
FOUND DURING C-CHECK, IN NASHVILLE, TN. CORROSION ON FLOOR SUPPORT AT LBL 33, FS 512. MAINTENANCE REMOVED CORROSION, TREATED WITH ALODINE 1200. REMAINING…
- 1 Mar 2001
Seat Track, corroded
FOUND DURING C-CHECK, IN NASHVILLE, TN. IB FLANGE CORRODED ON SEAT TRACK AT LBL 18.3 FROM FUSELAGE STA 294-560. MAINTENANCE REMOVED CORROSION, TRATED WITH…
- 28 Feb 2001
Skin, dented
FOUND DURING C-CHECK, NASHVILLE, TN. DENT ABOVE CAPT PITOT TUBE. MAINTENANCE REPAIRED DAMAGE ABOVE CAPT PITOT TUBE (UPPER) FOR TOUCH UP PAINT
- 26 Feb 2001
Channel, corroded
FOUND DURING C-CHECK, NASHVILLE, TN. THREE U CHANNELS ARE CORRODED THAT TIE FLOORBOARDS 122DZ AND 122EZ TO FLOORBOARD 121AZ. REFER TO W/O 19430, TASK 1543.…
- 26 Feb 2001
Floorboard, corroded
FOUND DURING C-CHECK FROM, IN NASHVILLE, TN. FLOORBOARD FLANGE AT STA 231.0 HAS CORROSION. REFER TO W/O 19430, TASK 2543. MAINTENANCE BLENDED OUT CORROSION…
- 23 Feb 2001
Shield, dented
FOUND DURING C-CHECK, NASHVILLE, TN. A GROUP OF DENTS AFT OF RT ICE SHIELD AT STA 345.0. REFER TO CELSIUS W/O 19430, TASK 2523, AND SAAB STATEMENT 340…
- 29 Oct 2000
Relay, failed
LEFT MAIN GEAR LIGHT WOULD NOT ILLUMINATE. PERFORMED LAMPS TEST, LAMPS TESTED OK. RECYCLED C/B F7, LIGHT CAME ON. ON APPROACH LIGHT WENT OUT AGAIN. RECYCLED…
- 25 Jan 2000
Control Box, failed
DTW - FLT 2997 - GEAR INTRANSIT LIGHT ON AFTER TAKEOFF AND GEAR RETRACTION, QRH FOLLOWED AND RETURNED TO DTW. MAINTENANCE REPLACED LANDING CONTROL UNIT. ALL…
- 12 Dec 1999
Deice Module, malfunctioned
INTERMITTENT ILLUMINATION OF LEFT INTAKE CAUTION LIGHT ON CLIMBOUT FROM DTW. LIGHT CYCLES ON FOR 2 - 7 SEC, THEN OFF 5 - 15 SEC, LIGHT DID NOT CYCLE ON…
- 11 Oct 1999
Skin, dented
DENT IN FORWARD CABIN BOTTOM SKIN JUST FWD OF STA 319.0 AND BETWEEN SL1626 AND SL1627. MAINTENANCE REPAIRED DENT PER EO NR S53062.
- 11 May 1998
Transducer, failed
AFTER CLIMB THE LEFT OIL PRESSURE GRADUAL FELL FROM 100 PSI TO 25 PSI, STAYED THERE AND THEN WENT BACK TO 100 PSI. AIRCRAFT RETURNED TO MSP. ON TAXI IN THE…
- 29 Apr 1998
Intake Light, illuminated
DURING FLIGHT, THE RIGHT INTAKE LIGHT ILLUMINATED, IT APPEARED TO CYCLE IN OVER TEMP MODE. AIRCRAFT RETURNED TO DTW. MAINTENANCE SWITCHED TO SPARE THERMISTOR…
- 2 Apr 1998
Connector, loose
INBOUND TO DTW PUT GEAR DOWN, NO LEFT HAND LANDING GEAR INDICATION. MAINTENANCE RESECURED LOOSE CANNON PLUG IN LEFT GEAR WHEEL WELL. ALL INDICATIONS GOOD AT…
- 4 Oct 1997
Fire Bottle, blown
FLT 3387 - EN ROUTE, CARGO SMOKE LIGHT ILLUMINATED. FLIGHT CREW PERFORMED QRH, LIGHT EXTINGUISHED. AIRCRAFT RETURNED TO DTW WITHOUT INCIDENT. MAINTENANCE…
- 4 Oct 1997
Detector, malfunctioned
FLT 3387 - EN ROUTE, CARGO SMOKE LIGHT ILLUMINATED. FLIGHT CREW PERFORMED QRH, LIGHT EXTINGUISHED. AIRCRAFT RETURNED TO DTW WITHOUT INCIDENT. MAINTENANCE…