N425YX
2014 Embraer S A ERJ 170-200 LR standard FAA →
registration
- 2014
service difficulty reports
42 reports
- 2 Oct 2025
Stringer, corroded
CENTER FUSELAGE III STRINGER 23L CORRODED. : REMOVED, REPAIRED AND REPLACED CENTER FUSELAGE III STRINGER 23L BETWEEN FR74-FR90 AND STRINGER 23L SPLICE…
- 28 Sep 2025
Plate, chafed
#2 ENGINE OUTBOARD T/R CENTER THERMAL BLANKET CHAFE PLATE CHAFED.REMOVED DAMAGED CHAFE PLATE, FABRICATE REPAIR PATCH REF.NO. REPUBLIC AIRWAYS…
- 28 Sep 2025
Plate, chafed
#1 ENGINE INBOARD T/R CENTER THERMAL BLANKET CHAFE PLATE CHAFED. REPAIRED PER REPUBLIC AIRWAYS 170EA-78-31-0004MR_1REV2
- 28 Sep 2025
Plate, chafed
#1 ENGINE INBOARD T/R CENTER THERMAL BLANKET CHAFE PLATE CHAFED.REMOVED DAMAGED CHAFE PLATE, FABRICATE REPAIR PATCH.REF.NO.REPUBLIC AIRWAYS…
- 29 Dec 2024
Fcu, faulted
FUEL 1 LOW LEVEL ON SHORT FINAL, DESPITE 7200LBS FUEL IN TANK. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R&R FUEL CONDITIONING UNIT.
- 20 Dec 2024
Warning Message, illuminated
FUEL 1 LOW LEVEL MESSAGE IN FLIGHT. OCCURRED AT FL230 ON DESCENT FROM FL280. NO OTHER INDICATIONS THAT FUEL MIGHT BE LOW. FUEL LEVEL WAS APPROXIMATELY 4650…
- 15 Jun 2024
Gcu, failed
ELECTRICAL EMERGENCY. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R&R GCU1.
- 10 Jun 2023
Gusset, corroded
O/B FLOOR GUSSET AT FR 85 CORRODED. R&R IAW SRM 51-41-02, 51-41-01, 51-43-04.
- 10 Jun 2023
Seat Track, corroded
AFT SEAT TRACK AT FR 82 MINOR CORROSION FOUND. REPAIRED IAW 53-00-10, NO CRACKS FOUND.
- 8 Jun 2023
Shear Panel, corroded
R/H SHEAR PNL BTWN FR 87-88 FOUND CORRODED. R&R IAW SRM 51-42-01.
- 8 Jun 2023
Seal Depressor, corroded
FWD CARGO DOOR SURND MID SEAL DEPRESS ANGLE UPPER & LOWER CORRODED. R&R IAW SRM 51-41-01.
- 8 Jun 2023
Seal Depressor, corroded
FWD CARGO DOOR SURND FWD SEAL DEPRESS ANGLE UPPER & LOWER CORRODED. R&R IAW AMM 20-10-01.
- 8 Jun 2023
Seal Depressor, corroded
FWD CARGO DOOR SURND AFT SEAL DEPRESS ANGLE UPPER & LOWER CORRODED. R&R IAW AMM 20-10-01.
- 8 Jun 2023
Shear Panel, corroded
MID SHEAR PNL BTWN FR 87-88 CORRODED. R&R IAW SRM 51-42-01.
- 8 Jun 2023
Seat Track, corroded
FWD R/H I/B SEAT TRACK AT FR 19 CORRODED. R&R IAW SRM 51-41-02, 51-43-01.
- 5 Jun 2023
Stabilizer, cracked
CRACK FOUND ON R/H H-STABRIB 11A. "MAJOR". CARD RAISED FOR 170EO-55-10-0004 RPAIR. CRACK LENGHT .075
- 29 Jul 2021
Unknown, odor
BURNING SMELL ON TAKEOFF ROLL, DISSIPATED AFTER EXITING RUNWAY. PERFORMED OPS CHECK OF AC PACK SYSTEM IAW AMM 21-00-00. OPS CHECKED GOOD, NO BURNING SMELL…
- 22 Jul 2020
Light, inoperative
PHOTOLUMINESCENT STRIPS INOP AT LOCATIONS SEATS 2A, FWD CLOSET AREA, (2 PIECES), AND 22-23DF. R&R PHOTOLUMINESCENT STRIPS AT LOCATIONS SEATS 2A, FWD CLOSET…
- 20 Mar 2020
Glowstrip, damaged
PHOTOLUMINESCENT STRIP LIGHT AT 1A DAMAGED. R&R 1A PHOTOLUMINESCENT STRIP IAW AMM 33-50-21.
- 22 Jun 2019
Circuit Breaker, tripped
EMERGENCY LIGHT ON IN ARMED POSITION WITH POWER ON A/C. FOUND EMERGENCY FWD BATTERY CIRCUIT BREAKER POPPED. RESET CIRCUIT BREAKER PER AMM 33-50-00.
- 23 Mar 2019
Glowstrip, damaged
RT FWD PHOTOLUMINESCENT STRIP MISSING SMALL PIECE. R&R PHOTOLUMINESCENT STRIP IAW AMM 33-50-21. OPS CHECK GOOD.
- 16 Mar 2019
Glowstrip, inoperative
THE PHOTOLUMINESCENT STRIP, AIRCRAFT RIGHT AT ROW 2 IS INOP. R&R THE PHOTOLUMINESCENT STRIP ON ROW 2 IAW AMM 33-50-21.
- 31 Oct 2018
Mechanism, lack of lube
R1 DOOR DIFFICULT TO ARM AND DISARM. CLEANED AND LUBRICATED THE R1 DOOR ARM DISARM MECHANISM. PERFORMED AN OPS CHECKED IAW AMM 52-11-40.
- 20 Aug 2018
Light, inoperative
COCKPIT EMERGENCY LIGHT NOT WORKING. R&R COCKPIT EMERGENCY LIGHT ASSEMBLY.
- 11 Aug 2018
Shear Panel, corroded
LEFT SHEAR PANEL AT FRAMES 87 - 88 CORRODED. REMOVED AND REPLACED THE SHEAR PANEL IAW SRM 51-40-08.
- 11 Aug 2018
Shear Panel, corroded
RT SHEAR PANEL, FRAMES 87 - 88 CORRODED. REMOVED AND REPLACED THE SHEAR PANEL IAW SRM 51-40-08.
- 11 Aug 2018
Closeout Panel, corroded
CORROSION AND LIGHT CHAFING ON THE FORWARD CARGO DOOR LOWER BEAM CLOSE OUT. REMOVED AND REPLACED FORWARD CARGO DOOR LOWER BEAM CLOSE OUT REF SRM 51-40-08. PN…
- 11 Aug 2018
Splice Plate, corroded
CORROSION FOUND ON THE LT SPLICE PLATE AROUND FASTENER HOLES, FRAMES 87 - 88. REMOVED AND REPLACED THE SPLICE PLATE IAW SRM 51-40-08.
- 4 Aug 2018
Seat Track, corroded
CORROSION FOUND ON THE LT INBD SEAT TRACK AT FRAME 28. INSTALLED A FILLER AND SPLICE PLATE IAW ETD2018-170-084939, AND SRM 53-00-10, REPAIR 01P.
- 3 Aug 2018
Support, corroded
CORROSION ON THE RT PANEL SUPPORT, FRAMES 88 - 89. REMOVED AND REPLACED THE PANEL SUPPORT IAW SRM 51-40-08.
- 3 Aug 2018
Splice, corroded
CORROSION FOUND ON THE RT SPLICE AT FRAME 89. REMOVED AND REPLACED THE SPLICE IAW SRM 51-40-08.
- 3 Aug 2018
Floor Support, corroded
CORROSION FOUND ON THE RT FLOOR SUPPORT, FRAMES 13 - 14. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-08.
- 3 Aug 2018
Seat Track, corroded
CORROSION FOUND ON THE RT, INBD SEAT TRACK AT FRAME 17. REMOVED AND REPLACED THE SEAT TRACK IAW SRM 51-40-08.
- 3 Aug 2018
Seat Track, corroded
CORROSION FOUND ON THE RT, INBD SEAT TRACK, BETWEEN FRAMES 84 - 85. BLENDED OUT THE CORROSION IAW ETD2018-170-084523.
- 2 Aug 2018
Support Angle, corroded
CORROSION ON THREE LOWER ANGLES ON PANEL 1431DL. REMOVED AND REPLACED THE ANGLES IAW SRM 51-40-08, SRM 51-40-02, SRM 51-23-04, AND 51-23-05.
- 2 Aug 2018
Support Angle, corroded
CORROSION ON THREE LOWER ANGLES ON PANEL 1441FR. REMOVED AND REPLACED THE ANGLES IAW AMM 20-10-01, AND SRM 51-40-02.
- 2 Aug 2018
Door, corroded
WASTE SERVICE DOOR AT THE REAR FUSELAGE AREA HAD CORROSION ON THE INSIDE OF THE DOOR WHERE BONDING WIRE ATTACHES. REMOVED AND REPLACED WASTE SERVICE DOOR IAW…
- 7 Jun 2018
Loop, faulty
BLEED 2 LEAK. MASKS DEPLOYED. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R&R ODS LOOP 5 SECTION 2RT0060 IAW AMM 36-21-02. OPS CHECK GOOD. ALL O2 GENERATORS…
- 29 Oct 2015
Light, damaged
CREW REPORTED THAT THE PHOTOLUMINESCENT STRIP WAS DAMAGED. MAINTENANCE R & R PHOTOLUMINESCENT STRIP IAW AMM AND OPS CHECKED GOOD.
- 8 Sep 2015
Flashlight, missing
CREW REPORTED THAT THE AFT JUMPSEAT FLASHLIGHT WAS MISSING. MAINTENANCE REPLACED MISSING FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.
- 29 Aug 2015
Coffeemaker, failed
F/A NOTICED SMOKE COMING FROM BOTTOM OF COFFEEMAKER. F/A TURNED POWER TO COFFEEMAKER OFF AND SMOKE STOPPED. CREW CONTACTED MAINTENANCE CONTROL AND CONTINUED…
- 21 Jun 2015
Battery Pack, inoperative
CREW REPORTED THAT THE FLIGHT DECK EMERGENCY LIGHT WOULD NOT TEST. MAINTENANCE R & R EMERGENCY BATTERY IAW AMM AND OPS CHECKED GOOD.