N425PA
2001 Piper PA-28-181 standard FAA →
registration
- 2001
earlier registrations
1 past record
- 1967
NTSB
- 17 Apr 2019
accident, Wickenburg AZ
service difficulty reports
11 reports
- 27 Mar 2018
Skin, cracked
DURING A SCHEDULED INSPECTION, FOUND THE INBOARD LOWER WING SKIN CRACKED, CRACK WAS LOCATED 4INCHES OUTBOARD OF THE BUTT RIB AND RUNNING PARALELL TO THE SPAR,…
- 11 Oct 2017
Frame, cracked
DURING ROUTINE MAINTENANCE, A FUSELAGE FRAME THAT ACTS AS THE FORWARD WING ATTACH STRUCTURE WAS FOUND TO BE CRACKED AT THE UPPER RIGHT END.
- 24 Aug 2017
Angle, cracked
DURING A ROUTINE INSPECTION, AN ANGLE INSTALLED AGAINST THE LEFT WING OURBOARD FLAP SUPPORT WAS FOUND CRACKED. CRACKING EXTENDED THROUGH RIVET HOLES TO…
- 26 Jun 2017
Stiffener, cracked
DURING ROUTINE INSPECTION A STIFFENER ON THE LEFT WING UPPER AFT SKIN NEAR ROOT WAS FOUND CRACKED THROUGH INBOARD MOST RIVET HOLE.
- 27 Oct 2016
Bracket, cracked
WHEN THE ELT WAS BEING REMOVED FOR INSPECTION, THE TECH DISCOVERED TWO 2" CRACKS NEXT TO THE NUTPLATES IN THE ELT MOUNTING BRACKET. THESE CRACKS CAN ONLY BE…
- 8 Sep 2016
Angle, cracked
DURING A ROUTINE INSPECTION, AN ANGLE IN THE RIGHT WING THAT IS CO-LOCATED WITH THE OUTBOARD FLAP MOUNTING BRACKET WAS FOUND TO BE CRACKED THROUGH THE RIVETS.
- 25 Aug 2015
Throttle Cable, separated
DURING ROUTINE INSPECTION, THE THROTTLE CABLE WAS FOUND PULLED APART. THE SEPARATION WAS AT THE SWAGE ON THE CARBURETOR END. HAD THE DEFECT GONE UNCORRECTED,…
- 22 Aug 2015
Oil Cooler, leaking
WHEN A MECHANIC PULLED THE TOP COWLING TO PERFORM ROUTINE MAINTENANCE, HE NOTED OIL WAS ALL OVER THE FIREWALL AND ACCESSORY CASE. INSPECTION REVEALED THE OIL…
- 26 May 2015
Cylinder Head, cracked
BORESCOPE EXAMINATION REVEALED THE NR 1 CYLINDER HEAD WAS CRACKED. AFTER THE CYLINDER WAS REMOVED, CRACKING WAS SEEN AT THE LOWER SPARK PLUG HOLE. THE…
- 26 May 2015
Cylinder Head, cracked
BORESCOPE EXAMINATION REVEALED THE NR 3 CYLINDER HEAD WAS CRACKED. AFTER THE CYLINDER WAS REMOVED, CRACKING WAS SEEN AT THE LOWER SPARK PLUG HOLE. THE…
- 29 Sep 2014
Bracket, cracked
DURING A PROGRESSIVE INSPECTION, A BRACKET WAS FOUND TO BE CRACKED BELOW WHERE THE FLAP HANDLE IS MOUNTED. THE BRACKET IN QUESTION IS LOCATED IN THE TUNNEL IN…