N422UE
1987 British Aerospace BAE JETSTREAM 3101 special flight permit FAA →
earlier registrations
1 past record
- 1987
service difficulty reports
24 reports
- 14 Feb 1998
Tq Indication, malfunctioned
SNA - LEFT TORQUE INDICATION FLUCTUATION REPORTED. AIRCRAFT RETURNED TO GATE. MAINTENANCE COULD NOT DUPLICATE DISCREPANCY. PERFORMED HIGH POWER GROUND RUN, NO…
- 26 Oct 1997
Pitot Tube, obstructed
SMF - LEFT AIR SPEED INDICATOR INOPERATIONAL ON TAEKOFF ROLL. MAINTENANCE CLEARED OBSTRUCTION FROM NR 1 PITOT TUBE. OPERATIONAL CHECK SATISFACTORY ON PITOT…
- 17 Oct 1997
Release Valve, tripped
SFO - LANDING GEAR WOULD NOT RETRACT. AIRCRAFT RETURNED TO STATION WITHOUT INCIDENT. MAINTENANCE RESET LANDING GEAR RELEASE VALVE BYPASS PIN. OPERATIONAL…
- 6 Oct 1997
Skin, bird strike
SMF - BIRD STRIKE TO LEFT NOSE AREA JUST AFT OF RADOME REPORTED. MAINTENANCE INSPECTED AREA FOR DAMAGE. NO DAMAGE NOTED. AIRCRAFT RETURNED TO SERVICE. (M)
- 25 Nov 1996
Contactor, failed
MCE - LEFT GENERATOR FAILED IN FLIGHT, EN ROUTE FAT TO MCE. AIRCRAFT DIVERTED TO SFO FOR REPAIRS. MAINTENANCE REPLACED LEFT STARTER GENERATOR. PROBLEMS…
- 27 Aug 1996
Fuel Cntrl Unit, out of adjust
SEA - RIGHT ENGINE FAILED TO DEVELOP REQUIRED TAKEOFF POWER. TAKEOFF ABORTED WITHOUT INCIDENT. MAINTENANCE ADJUSTED ENGINE RIGGING. CHECKS GOOD ON ENGINE…
- 25 Aug 1996
Fuel Cntrl Unit, malfunctioned
SEA - RIGHT ENGINE FAILED TO DEVELOP REQUIRED TAKEOFF POWER. TAKEOFF ABORTED WITHOUT INCIDENT. MAINTENANCE ACCOMPLISHED ENGINE GROUND RUN. FOUND ENGINE…
- 7 Aug 1996
Actuator, failed
PDX - NOSE LANDING GEAR FAILED TO RETRACT ON TAKEOFF. AIRCRAFT RETURND TO STATION WITHOUT INCIDENT. AIRCRAFT WAS FERRIED TO EUG FOR REPAIRS. MAINTENANCE…
- 4 Aug 1996
Selector Valve, failed
NOSE LANDING GEAR WOULD NOT RETRACT AFTER TAKEOFF. ACFT RETURNED TO STATION WITHOUT INCIDENT. ACFT FERRIED TO EUG FOR REPAIRS. MAINTENANCE REPLACED GEAR SEL…
- 8 Mar 1996
Engine, failed
CIC - LEFT ENGINE TORQUE DROPPED TO 90 PERCENT TORQUE DURING TAKEOFF ROLL. TAKEOFF ABORTED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED LEFT ENGINE.…
- 23 Feb 1996
Reducing Valve, failed
FAT - WHEN TOE BRAKES APPLIED, NO BRAKE PRESSURE INCREASE ON LT OR RT GAUGE NOTED DURING BRAKE TEST PRIOR TO LANDING. THREE TO FIVE SECOND DELAY IN BRAKE…
- 21 Feb 1996
Switch, out of adjust
CIC - POD DOOR WARNING INDICATION ACTIVATED ON ROTATION. AIRCRAFT RETURNED TO STATION WITHOUT INCIDENT. DETERMINED POD DOOR WAS SECURED WITH FALSE INDICATIONS…
- 4 Feb 1996
Smoke Detector, moisture
SFO - SMOKE DETECTION LIGHT ACTIVATED ON TAXI-OUT. AIRCRAFT RETURNED TO GATE. LIGHT EXTINGUISHED UPON ENGINE SHUTDOWN. NO SMOKE OR FIRE DETECTED. DETERMINED…
- 4 Feb 1996
Smoke Detector, intermittent
SFO - SMOKE DETECTION LIGHT ACTIVATED ON RAMP. NO SMOKE OR FIRE DETECTED. DETERMINED TO BE FALSE INDICATION. REPLACED SMOKE DETECTOR. SMOKE DETECTION SYSTEM…
- 31 Jan 1996
Smoke Detector, dirty
SFO - SMOKE DETECTION LIGHT ACTIVATED ON TAXI-OUT. AIRCRAFT RETURNED TO GATE. NO SMOKE OR FIRE DETECTED. DETERMINED TO BE FALSE INDICATION. CLEANED SMOKE…
- 28 Jan 1996
Radome, bird strike
SFO - BIRD STRIKE REPORTED AT NOSE AREA OF AIRCRAFT. MAINTENANCE ACCOMPLISHED BIRD STRIKE INSPECTION ON AIRCRAFT. NO DEFECTS NOTED. AIRCRAFT RETURNED TO…
- 13 Jan 1996
Connector, dirty
ACV - LEFT ENGINE TORQUE AND EGT INDICATION DROPPED WITH ENGINE SURGE DURING TAKEOFF ROLL. TAKEOFF ABORTED WITHOUT INCIDENT. MAINTENANCE CLEANED CANNON PLUG…
- 20 Nov 1995
Maxaret, failed
SFO - RIGHT BRAKE REPORTED INOPERATIVE DURING LANDING ROLL OUT. MAINTENANCE REPLACED RIGHT LANDING GEAR BRAKE MAXARET ASSEMBLY. RIGHT BRAKE REPORTED…
- 18 Nov 1995
Egt Resistor, failed
BFL - LEFT ENGINE FAILED TO OBTAIN MINIMUM STATIC TORQUE. TAKEOFF ABANDONED WITHOUT INCIDENT. MAINTENANCE REPLACED AND ADJUSTED LEFT ENGINE EGT COMPENSATING…
- 14 Feb 1995
Tach Generator, failed
LAX - LEFT ENGINE RPM INDICATOR REPORTED INOPERATIVE AFTER DEPARTURE. AIRCRAFT RETURNED TO STATION WITHOUT INCIDENT. MAINTENANCE REPLACED LEFT ENGINE TACH…
- 21 Dec 1994
Connector, contaminated
SEA - STALL WARNING AUDIO AND STICK SHAKER ACTIVATED AT 161 KNOTS. MAINTENANCE REPLACED LT LIFT TRANSDUCER CANNON PLUG. OPERATIONAL CHECK OF STALL SYSTEM…
- 21 Dec 1994
Connector, contaminated
SEA - THE RT STALL WARNING SYSTEM ACTIVATED ON TAXI. MAINTENANCE CHECKED OPERATION OF RT WARNING SYSTEM. OPERATIONAL CHECK GOOD. FOUND SMALL AMOUNT OF GLYCOL…
- 20 Dec 1994
Stall Vane, failed
SEA - STALL WARNING SYSTEM ACTIVATED WITH ASSOCIATED STICK SHAKER AND HORN. MAINTENANCE REPLACED LT STALL VANE. OPERATIONAL CHECK GOOD. ACFT RETURNED TO…
- 20 Dec 1994
Lift Transducer, failed
SEA - UPON TAXI OUT, STALL HORN AND SHAKER INTERMITTENTLY ACTIVATED. ACFT RETURNED TO GATE. MAINTENANCE INSPECTED SYSTEM, FOUND NR 1 STALL HEAT TO ACTIVATE LT…