N413US
Cessna 305A FAA →
registration
earlier registrations
1 past record
- 1988
NTSB
- 2 Aug 1989
incident, Greensboro NC
service difficulty reports
65 reports
- 29 Jun 2002
Battery Pack, not seated
IND - MAINTENANCE FOUND THE EMERGENCY LIGHTS AT SEAT ROWS 20 THROUGH 23 AND AT THE AFT LEFT SERVICE DOOR INOPERATIVE. MAINTENANCE RERACKED THE BATTERY PACK.…
- 22 Apr 2002
Fuse, broken
PIT - FOUND BROKEN FUSE ON EMERGENCY LIGHT CHARGER. MAINTENANCE REPLACED THE CHARGER. (M)
- 22 Apr 2002
Charger, inoperative
PIT - FOUND CIRCUIT INOPERATIVE ON EMERGENCY LIGHT BATTERY CHARGER. MAINTENANCE REPLACED THE BATTERY CHARGER. (M)
- 5 Feb 2002
Smoke Detector, malfunctioned
CLT - FLT 417 - ON CLIMB-OUT FROM CLT, EN ROUTE TO SRQ, THE FLIGHT ATTENDANT REPORTED THE FORWARD LAVATORY SMOKE DETECTOR ALARM SOUNDING. FLIGHT RETURNED TO…
- 16 Nov 2001
Skin, cracked
TPA - FOUND SKIN .250 INCH, UPPER HINGE CUTOUT ON MAIN ENTRY DOOR. INSTALLED DOUBLER PER SB 737-52-1096 ALSO EA NR 94248. (M)
- 27 Jul 2001
Frame, cracked
CLT - FOUND SIDE CHORDS .5 INCH, BS 178 WL 207 LEFT AND RIGHT SIDE. DAMAGE SECTION REMOVED, INSTALLED CHORD SPLICE REPAIR AND EXT SKIN STRAP PER EO 5300V157.…
- 27 Jul 2001
Strap, damaged
CLT - FOUND VERTICAL STRAP .125 INCH, BS 178, WL 208, LBL 25. DAMAGE SECTION REMOVED, REPLACEMENT SECTION SPLICED IN WITH DOUBLER PER EA 85114. (M)
- 27 Jul 2001
Bulkhead, damaged
CLT - FOUND PRESSURE WEB WITH ELONGATED HOLES, .281 INCH TO .321 INCH, BS 178, WL 207. DAMAGE REMOVED, INSTALLED ACCESS HOLE DOUBLER PER EA 85146. (M)
- 27 Jul 2001
Bulkhead, cracked
CLT - FOUND PRESSURE WEB CRACKED .5 INCH, BS 178 WL 217 AT LBL 6. DAMAGE REMOVED, REPAIR DOUBLER INSTALLED PER EO 5300V153. (M)
- 27 Jul 2001
Stiffener, cracked
CLT - FOUND VERTICAL CHORD CRACKED IN TWO PLACES .25 INCH EACH, BS 178, WL 184 AND 195 AT LBL 5.7. DOUBLER INSTALLED PER EO 5300V155. (M)
- 14 Jun 2001
Skin, cracked
CLT - FOUND SKIN CRACKED, BS 727D, LEFT SIDE, EMERGENCY LIGHT AFT OF WHEEL WELL. DAMAGE REMOVED, INSTALLED DOUBLER PER SRM 53-00-01, FIG 202. (M)
- 10 May 2001
Skin, cracked
PIT - FOUND SKIN CRACKED 2.5 INCHES, STRINGER 23R STATION 727D. CUT OUT DAMAGE, INSTALLED EXTERNAL DOUBLER PER EA 71032 AND SRM 53-00-01 FIG 202. (M)
- 14 Feb 2001
Frame, cracked
CLT - FOUND FRAME CRACKED .5 INCH, STATION 400 FRAME RIGHT SIDE BETWEEN STRINGER 8R AND 9R. REMOVED DAMAGED, REPAIRED TR 53-10-14. (M)
- 5 Feb 2001
Blade, damaged
BWI - FLT 1882 - EN ROUTE FROM CLT TO PHL, BOTH ENGINE VIBRATION INDICATORS APPROACHED NR 5. FLIGHT DIVERTED TO BWI AND LANDED WITHOUT FURTHER INCIDENT. UPON…
- 24 Nov 2000
Transmitter, failed
PHL - FLT 80 - EN ROUTE FROM PIT TO PHL, THE NR 2 ENGINE OIL PRESSURE DROPPED TO 20 PSI, THEN TO RED RADIAL. OIL TEMPERATURE AND OIL QUANTITY WERE BOTH…
- 10 Sep 2000
Wire, broken
CLT - FLT 1620 - ON FINAL APPROACH, AT FL030, A FLAP ASYMMETRY OCCURRED. AS CREW EXTENDED FLAPS FROM 5 TO 10 DEGREES, RIGHT FLAP NEEDLE WENT OT 10 DEGREES AND…
- 11 Mar 2000
Controller, failed
BDL - FLT 519 - DURING CLIMB-OUT FROM BDL, AT APPROXIMATELY FL210, THE CABIN WARNING HORN SOUNDED. NO OTHER WARNING INDICATORS ILLUMINATED. CABIN ALTITUDE WAS…
- 17 May 1999
Connector, loose
TPA - MAINTENANCE FOUND THE EMERGENCY AISLE LIGHTING AT SEAT ROW 6A AND THE FIRST CLASS CABINET, LEFT SIDE INOPERATIVE. MAINTENANCE FOUND THE CANNON PLUG AT…
- 2 May 1999
Web, cracked
CLT - DURING Q-2 CHECK VISUAL INSPECTIOIN, FOUND A CRACK .5 INCH VERTICAL ON WEB AT STATION 178 RBL 4.5 WL 198 BULKHEAD WEB. INSTALLED DOUBLER AND FILLER PER…
- 2 May 1999
Web, cracked
CLT - DURNG Q-2 CHECK VISUAL INSPECTION, FOUND A CRACK .5 INCH VERTICAL ON WEB AT STATION 178 RBL 4.5 WL 201 BULKHEAD WEB. INSTALLED DOUBLER AND FILLER PER…
- 2 May 1999
Frame, cracked
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK AT BS 827 BETWEEN STRINGER 8L AND 9L FRAME. INSTALLED FILLER AND DOUBLER PER SRM 53-00-07,…
- 2 May 1999
Frame, cracked
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .375 INCH CRACK AT BS 867 BETWEEN STRINGER 8L AND 9L FRAME. INSTALLED DOUBLER PER SRM 53-00-07 AND EA 64326.…
- 2 May 1999
Frame, cracked
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK AT BS 727F BETWEEN STRINGER 8L AND 9L FRAME. INSTALLED DOUBLER PER SRM 53-00-07, SRM…
- 2 May 1999
Beam, corroded
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND SURFACE CORROSION FS 344 BL 0 TO LBBL 10 BEAM. CORROSION TASK NR C53-107-02. INSTALLED T-CHORD PER EA 64363…
- 2 May 1999
Bulkhead, cracked
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 1.5 INCH CRACK AT BS 178 RBL .5 WL 188 BULKHEAD WEB. INSTALLED DOUBLER PER SRM 53-10-08. (M)
- 2 May 1999
Bulkhead Web, corroded
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND CORROSION AFT PRESSURE BULKHEAD DOME WEB STIFFENER AT BOTTOM OF BL 0 STATION 1016. INSTALLED REPAIR STIFFENER…
- 2 May 1999
Bulkhead, corroded
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 6 INCH AREA OF CORROSION AT PRESSURE BULKHEAD RT OF BL 0 JUST AFT STATION 1016. INSTALLED DOUBLER PER SRM…
- 2 May 1999
Beam, corroded
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND AN AREA OF SURFACE CORROSION SPOTS APPROX 1 INCH AT FS 312, LBBL 24 TO RBBL 12. CORROSION TASK NR C53-107-02.…
- 2 May 1999
Frame, cracked
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK IN FRAME AT BS 747 BETWEEN STRINGER 8R AND STRINGER 9R. REPAIRED DOUBLER PER EA 64326 AND SRM…
- 2 May 1999
Frame, cracked
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK IN FRAME AT BS 727F BETWEEN STRINGER 8R AND 9R. DOUBLER REPAIRED PER SRM 53-00-07 GIF 202. (M)
- 2 May 1999
Frame, cracked
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK IN FRAME AT BS 727D BETWEEN STRINGER 8L AND STRINGER 9L. REPAIRED DOUBLER PER EA 64326 AND SRM…
- 2 May 1999
Frame, cracked
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK IN FRAME AT BS 727A BETWEEN STRINGER 8R AND STRINGER 9R. REPAIRED DOUBLER PER EA 64326 AND SRM…
- 2 May 1999
Web, corroded
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 14 INCH BY 30 INCH AREA OF SPOTTED CORROSION UNDER AFT CARGO SILL PANEL WEB. CORROSION TASK NR C53-202-07.…
- 2 May 1999
Floorbeam, corroded
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 1 INCH AREA OF SPOTTED CORROSION FROM STATION 787 TO 847 RBL 14 FLOORBEAM. CORROSION TASK NR C53-208-01.…
- 2 May 1999
Angle, corroded
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 26 INCH AREA OF CORROSION AT FORWARD ENTRY DOOR THRESHOLD 'Z' ANGLE F/S 270 TO FS 344 LBBL 55. REMOVED AND…
- 2 May 1999
Floorbeam, corroded
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 32 INCH AREA OF CORROSION AT STATION 947.5 LT AND RT OF BL 0 FLOORBEAM. REPAIRED 'T' CAP PER TR 53-60-02. (M)
- 2 May 1999
Frame, cracked
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 9 INCH CRACK IN FRAME AT BS 747 BETWEEN STRINGER 8L AND STRINGER 9L. INSTALLED DOUBLER PER EA 64326. (M)
- 2 May 1999
Tie Clip, cracked
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK AT TIE CLIP STATION 767 STRINGER 26L. REMOVED AND REPLACED STRINGER TIE CLIP PER SRM 51-10-2.…
- 2 May 1999
Web, cracked
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK AT STATION 178 LBL 4.5 W/L 201 WEB. FABRICATED AND INSTALLED DOUBLER PER EA 6420. (M)
- 2 May 1999
Frame, cracked
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK AT BS 787 BETWEEN STRINGER 8R AND STRINGER 9R FRAME. INSTALLED DOUBLER PER SRM 53-00-07 FIG…
- 2 May 1999
Floor, cracked
CLT - DURING Q-2 CHECK, NDT VISUAL INSPECTION, FOUND A .75 INCH CRACK AT BS 663.75 LBL 32 FLOOR. INSTALLED DOUBLER PER EA 64378. (M)
- 2 May 1999
Frame, cracked
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK AT BS 907 BETWEEN STRINGER 8R AND STRINGER 9R FRAME. INSTALLED DOUBLER PER SRM 53-00-07 FIG…
- 2 May 1999
Frame, cracked
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK AT BS 867 BETWEEN STRINGER 8R AND STRINGER 9R FRAME. INSTALLED DOUBLER PER SRM 53-00-07 FIG…
- 2 May 1999
Strap, corroded
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 2 INCH BY 67 INCH AREA OF SPOTTED CORROSION AT RBL 20 STATION 780-847 STRAP. INSTALLED NEW STRAP PER SRM…
- 2 May 1999
Bulkhead, corroded
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 5.3 INCH BY 3.5 INCH AREA OF CORROSION AT RBL 3 STATION 1016 PLUS 5 INCHES BL 0 PRESS BULKHEAD. INSTALLED…
- 2 May 1999
Beam, corroded
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 1 INCH SPOT OF SURFACE CORROSION AT FS 328 RBL 40 BEAM, CORROSION TASK NR C53-107-02. SPLICED IN NEW SECTION…
- 2 May 1999
Floorbeam, corroded
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND CORROSION AT STATION 986.5 ALONG ENTIRE FLOORBEAM CORROSION TASK NR C53-107-02. INSTALLED NEW T-CAP, STRAPS,…
- 2 May 1999
Angle, cracked
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 1 INCH CRACK IN RADIUS AT STATION 294.5 RBL 54.75 WL 208 ANGLE. INSTALLED DOUBLER ANGLE PER SRM 51-70-11. (M)
- 2 May 1999
Frame, cracked
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .375 INCH CRACK IN FRAME AT BS 400 BETWEEN STRINGER 8L AND STRINGER 9. FABRICATED DOUBLER AND INSTALLED PER…
- 30 Apr 1999
Bulkhead, corroded
CLT - DURING Q-2 CHECK, FOUND 4INCH BY 10 INCH CORROSION AT STRINGER 27R TO 27L AT BOTTOM OF AFT PRESSURE BULKHEAD. CORROSION TASK NR C53-202-1. CORROSION…
- 30 Apr 1999
Bulkhead, corroded
CLT - DURING Q-2 CHECK, FOUND 3 INCHES OF CORROSION AT BL 0 AFT OF 1016 ON WEB OF PRESSURE BULKHEAD, CORROSION LEVEL 2. INSTALLED WEB STIFFENER PER SRM…
- 30 Apr 1999
Bulkhead Angle, drill marks
CLT - DURING Q-2 CHECK, FOUND 3 PLACES .125 INCH DRILL MARKS AT BS 1030 RBL 23 (UNDER FLOOR ATTACH ANGLE) AT 1016 PRESSURE BULKHEAD. BLENDED AREAS/DRILLED…
- 19 Nov 1998
Module, malfunctioned
BWI - FLT 1168, FLIGHT DEPARTED BWI WITH THE NR 1 GENERATOR ON MEL. AT APPROXIMATELY FL230, THE APU SHUTDOWN AUTOMATICALLY DUE TO AN OVERSPEED LIGHT WAS…
- 19 Nov 1998
Switch, malfunctioned
BWI - FLT 1168, FLIGHT DEPARTED BWI WITH THE NR 1 GENERATOR ON MEL. AT APPROXIMATELY FL230, THE APU SHUTDOWN AUTOMATICALLY DUE TO AN OVERSPEED LIGHT WAS…
- 10 Nov 1998
Rectifier, failed
PHL - FLT 162 - SHORTLY AFTER T/O, THE NR 1 TRANSFORMER RECTIFIER C/B TRIPPED FOLLOWED BY THE BATTERY CHARGER AND THE 'B' SYSTEM ELECTRIC HYDRAULIC PUMP.…
- 10 Nov 1998
Transformer, failed
PHL - FLT 162 - SHORTLY AFTER T/O, THE NR 1 TRANSFORMER RECTIFIER C/B TRIPPED FOLLOWED BY THE BATTERY CHARGER AND THE 'B' SYSTEM ELECTRIC HYDRAULIC PUMP.…
- 29 May 1998
Control Valve, malfunctioned
CLT - FLT 2250 - DURING APPROACH, PILOT REPORTED A FOUL OIL SMELL CAME FROM THE AIR CONDITIONING PACKS INTO THE CABIN AS THE FLAPS WERE LOWERED. FLIGHT LANDED…
- 29 May 1998
Turbofan, malfunctioned
CLT - FLT 2250 - DURING APPROACH, PILOT REPORTED A FOUL OIL SMELL CAME FROM THE AIR CONDITIONING PACKS INTO THE CABIN AS THE FLAPS WERE LOWERED. FLIGHT LANDED…
- 28 Jul 1997
Switch, dirty
DCA - FL 826 - WHILE EXTENDING FLAPS BETWEEN 1 AND 5 DEGREE GEAR WARNING HORN SOUNDED. UNABLE TO SILENCE UNTIL GEAR WAS EXTENDED. RECYCLED WITH SAME RESULTS.…
- 20 Jul 1997
Fuse, blown
TPA - MAINTENANCE FOUND THE EMERGENCY AISLE LIGHT AT SEAT ROW 1D INOP. MAINTENANCE REMOVED AND REPLACED THE 5 AMP FUSE ON THE BATTERY CHARGER. OPS CHECK GOOD.…
- 14 Jun 1997
Battery Charger, failed
ORD - MAINTENANCE FOUND THE EMERGENCY AISLE LIGHT AT SEAT 1D OVERHEAD BIN INOP. MAINTENANCE RELAMPED LIGHT WITH NO HELP. CHECKED WIRING TO BATTERY CHARGER.…
- 12 Apr 1997
Indicator Light, defective
PHX - FL155, WHILE ON APPROACH TO PHX, FOLLOWING GEAR EXTENSION, THE CREW OBSERVED GREEN LIGHTS FOR THE RIGHT MAIN LANDING GEAR AND THE NOSE LANDING GEAR, BUT…
- 11 Apr 1997
Circuit Card, failed
FLL - FL 2169 - ON DESCENT INTO FLL, CREW RECEIVED NO GREEN LIGHT INDICATION FOR THE LEFT MAIN LANDING GEAR DURING GEAR EXTENSION. CAPTAIN RECYCLED GEAR AND…
- 29 Dec 1996
Hydraulic Pump, failed
BWI - FL 1282 - THE 'A' HYDRAULIC SYSTEM OVERHEAT LIGHT ILLUMINATED DURING FLIGHT. CREW TURNED PUMP OFF AND AFTER FIVE MINUTES, LIGHT WENT OUT. HYDRAULIC QTY…
- 13 Dec 1996
Power Supply, cabin
CLE - MAINTENANCE FOUND THE FORWARD RIGHT BULLNOSE EMERGENCY LIGHT INOP. MAINTENANCE REMOVED AND REPLACED THE POWER SUPPLY IN THE FORWARD OVERHEAD CABIN. OPS…