N412YX
2013 Embraer ERJ 170-200 LR standard FAA →
registration
- 2013
service difficulty reports
38 reports
- 6 Feb 2026
Battery, no test
DURING FUNCTIONAL CHECK, NR 1 EMERGENCY LIGHTS BATTERY FAILED TO MEET THE 15 MINUTE OPS CHECK. REMOVED AND REPLACED THE NR 1 EMERGENCY LIGHT BATTERY.
- 1 Nov 2024
Unknown, odor
SHORTLY AFTER TAKEOFF, FA AND PASSENGERS NOTED SMOKE SMELL IN THE AFT GALLEY. NO VISIBLE SMOKE OR EICAS MESSAGES. AIRCRAFT RETURNED TO FIELD. PERFORMED ENGINE…
- 3 Dec 2023
Unknown, unknown
CARGO AFT FIRE SYSTEM FAIL AND CARGO FWD FIRE SYSTEM FAIL MESSAGE ACTIVE ON EICAS. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R&R AFT CARGO COMPARTMENT…
- 17 Sep 2022
Crossbeam, corroded
SEVERAL AREAS OF CORROSION AS MARKED ON FR 14 CROSSBEAM OUTBOARD OF RH SEAT TRACK. PERFORMED PERMANENT SPLICE REPAIR ON CROSSBEAM FR 14 O/B OF RH SEAT TRACK.…
- 15 Sep 2022
Splice Plate, elongated
HOLE ELONGATED WHILE REMOVING LH SPLICE PLATE AT FR 89. : COMPLIED WITH ETD2022-170-029079
- 14 Mar 2022
Switch, faulty
GEAR WOULD NOT RETRACT, DECLARED EMERGENCY, RETURNED TO FIELD, AND LANDED WITH OUT INCIDENT. CMC SHOWED #2 NOSE GEAR WOW SWITCH FAULTY. REMOVED & REPLACED #2…
- 7 Nov 2021
Control Lever, faulted
LANDING GEAR LEVER DISAGREE DURING CLIMBOUT. ALL 3 GEARS INDICATE DOWN AND RED. ATTEMPTED 3 RETRACTIONS. WHEN DOWN SELECTED, ALL MESSAGES CLEARED AND…
- 10 Jan 2021
Light, discolored
PHOTOLUMINESCENT STRIP AT FWD CLOSET AND JOGGLE ARE WHITE/LOSING COLOR. R & R PHOTOLUMINESCENT STRIPS, IAW AMM 33-50-21.
- 14 Jul 2020
Fuse, blown
AFT EXIT LOCATOR INOP. R&R FUSE F2 IN ELPU NR 3 IAW AMM 33-50-01.
- 16 Jan 2020
Shear Panel, corroded
WHILE IN HEAVY CHECK FOUND CORROSION AT FLOOR FR 87-88 CENTER SHEAR PANEL AS MARKED. REMOVED CORROSION BY BLENDING ON CENTER SHEAR PANEL FR 87-88, 0.024"…
- 15 Jan 2020
Splice, corroded
WHILE IN HEAVY CHECK FOUND CENTER LOWER SPLICE BETWEEN PANELS 192DL AND 195NL IS CORRODED REMOVED AND REPLACED SPLICE BETWEEN 192DL AND 195NL REF. AMM 53-04-50
- 9 Jan 2020
Stringer, cracked
MAJOR: STRINGER 9L IS CRACKED AT REAR PRESSURE BULKHEAD NEAR WASTE TANK ATTACHMENT. REMOVED AND REPLACED STRINGER 9L AT REAR PRESSURE BULKHEAD NEAR WASTE TANK…
- 8 Jan 2020
Rib, cracked
MAJOR: CRACK RH HORIZONTAL STAB RIB 11 BETWEEN SPAR 1 AND SPAR 2 AS MARKED. PERFORMED 170EO-55-10-0004_1 LEFT AND RIGHT HSTAB RIB 10A, 11A & 12A REPLACEMENTS.…
- 8 Jan 2020
Rib, cracked
MAJOR: CRACK RH HORIZONTAL STAB RIB 12 BETWEEN SPAR 1 AND SPAR 2 AS MARKED. PERFORMED 170EO-55-10-0004. AIRCRAFT REMAINS IN HEAVY CHECK BNA.
- 21 Dec 2019
Skin, dented
2 DENTS WITH CREASES DISCOVERED AT LEFT FORWARD FUSELAGE BETWEEN FRAMES 1-2 AND STRINGERS 20L-24L. AC WAS REPAIRED IAW ETD 2019-170-164693A. MAJOR REPAIR/FCBS…
- 24 Feb 2018
Seal Rest, corroded
WHILE IN HEAVY CHECK - CORROSION STRUCTURAL CENTER FUSELAGE I FWD CARGO 53-21 CENTER SEAL REST. REMOVED AND REPLACED FWD CARGO 53-21 CENTER SEAL REST.
- 24 Feb 2018
Closeout Panel, corroded
WHILE IN HEAVY CHECK, CORROSION STRUCTURAL CENTER FUSELAGE I FWD CARGO CLOSEOUT PANEL. REMOVED AND REPLACED CARGO DOOR CLOSEOUT PANEL AS REQUIRED.
- 24 Feb 2018
Shear Plate, corroded
WHILE IN HEAVY CHECK, CORROSION RT SHEAR PLATE. REMOVED AND REPLACED RT SHEAR PLATE PN: 170-10064-001.
- 24 Feb 2018
Beam, corroded
WHILE IN HEAVY CHECK, CORROSION CENTER FUSELAGE III WET AREA 53-23 RT BEAM Y=+10-748. REMOVED AND REPLACED BEAM PN: 170-65669-004.
- 24 Feb 2018
Seat Track, corroded
WHILE IN HEAVY CHECK, CORROSION STRUCTURAL CENTER FUSELAGE III WET AREA 53-23 RT SEAT TRACK. CUTOUT OUT AFFECTED AREA, FABRICATED AND INSTALLED DOUBLER AT…
- 24 Feb 2018
Angle, corroded
WHILE IN HEAVY CHECK, CORROSION ON BOTH LOWER ANGLES ON PANEL 1431DL. REMOVED BOTH LOWER ANGLES ON PANEL 1431DL. REF SRM 51-40-02. DRILLED UP NEW ANGLES REF…
- 24 Feb 2018
Door Sill, corroded
WHILE IN HEAVY CHECK, CORROSION RT FWD SILL FRAME 84. REMOVED AND REPLACED CENTER FUSELAGE 3 DRY AREA RT FWD SILL, JUST FWD OF AFT SERVICE DOOR AND APPLIED…
- 24 Feb 2018
Finger Doubler, corroded
WHILE IN HEAVY CHECK, CORROSION STRUCTURAL CENTER FUSELAGE I FWD CARGO 53-21 FWD FINGER DOUBLER. REMOVED AND REPLACED FWD CARGO FWD FINGER DOUBLER REF SRM.
- 10 Feb 2018
Closeout Panel, corroded
DURING HEAVY CHECK, FOUND THE AFT CARGO CLOSE OUT PANEL CORRODED. REMOVED AND REPLACED THE CLOSE OUT PANEL.
- 10 Feb 2018
Floor Support, corroded
DURING HEAVY CHECK, FOUND THE FWD FUSELAGE WET AREA RT FWD FLOOR SUPPORT CORRODED FRAMES 12-14. REMOVED AND REPLACED THE FLOOR SUPPORT.
- 10 Feb 2018
Upper Sheet, corroded
DURING HEAVY CHECK, THE AFT WET AREA WAS FOUND CORRODED ON THE RT UPPERSHEET, FRAMES 85 - 86.
- 17 Jan 2018
Quick Disconnect, cracked
NR 1 EDP FAILED AND HYD 1 LOW QUANTITY MESSAGES WITH QUANTITY READING 0. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. SERVICED THE NR 1 HYDRAULIC SYSTEM IAW…
- 22 May 2017
Battery, malfunctioned
EMERGENCY LIGHT FAULT EICAS MESSAGE PRESENT. RESET AFT OUTBOARD EMERGENCY LIGHT BATTERY IAW FIM 33-50-00-810-803-A00. FAULT CLEARED.
- 15 Jan 2017
Light, malfunctioned
CREW REPORTED THAT TWO EMERGENCY LIGHTS WERE STUCK ON WITH AN EMERGENCY LIGHT BATTERY FAULT MESSAGE. MAINTENANCE RESET AIRCRAFT POWER IAW AMM AND OPS CHECKED…
- 9 Nov 2016
Flashlight, inoperative
CREW REPORTED THAT THE FORWARD FLIGHT ATTENDANT FLASHLIGHT WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED FORWARD FLIGHT ATTENDANT FLASHLIGHT IAW AMM AND…
- 9 Nov 2016
Flashlight, inoperative
CREW REPORTED THAT THE AFT FLIGHT ATTENDANT FLASHLIGHT WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED AFT FLIGHT ATTENDANT FLASHLIGHT IAW AMM AND OPS…
- 8 Aug 2016
Smoke Warning, false activation
DURING FLIGHT, CREW RECEIVED A LAVATORY SMOKE MESSAGE. FOLLOWED QRH, FLIGHT ATTENDANTS CHECKED LAVATORYIES WITH NO EVIDENCE OF FIRE FOUND.
- 24 Jan 2016
Warning Message, false activation
CREW REPORTED THAT THEY RECEIVED AN EMERGENCY LIGHT BATTERY FAULT ON EICAS AND THERE WERE SEVERAL AFT CABIN EMERGENCY LIGHTS ON WHEN THE SWITCH WAS IN THE…
- 16 Jun 2015
Light, inoperative
MAINTENANCE REPORTED THAT THE EMERGENCY LIGHT ABOVE THE AFT RT SERVICE DOOR WAS INOPERATIVE. MAINTENANCE R & R AFT RT EMERGENCY LIGHT IAW AMM AND OPS CHECKED…
- 23 Mar 2015
Megaphone, inoperative
CREW REPORTED THAT THE MEGAPHONE WAS INOPERATIVE. MAINTENANCE R & R MEGAPHONE IAW AMM AND OPS CHECKED GOOD.
- 16 Oct 2014
Battery Pack, inoperative
CREW REPORTED THAT THE EMERGENCY LIGHTS WOULD NOT POWER ON. MAINTENANCE R & R THE EMERGENCY BATTERY IAW AMM AND OPS CHECKED GOOD. ACFT IS GOOD FOR SERVICE.
- 1 Oct 2014
Battery Pack, inoperative
CREW REPORTED THAT THE EMERGENCY LIGHT IN THE CABIN CEILING WAS BURNED OUT. MAINTENANCE R & R EMERGENCY BATTERY IAW AMM AND OPS CHECKED GOOD.
- 27 Mar 2014
Flashlight, missing
CREW REPORTED THAT THE CAPTAINS FLASHLIGHT WAS MISSING.