N411YX
2013 Embraer ERJ 170-200 LR standard FAA →
registration
- 2013
service difficulty reports
37 reports
- 27 Jun 2026
Engine, faulted
ENG 2 FAIL AROUND 10,000 FT. N1 WENT TO 15.2. HIGH ENG VIB, ENG #2 ITT GAUGE TURNED RED. UPON LANDING ENG #2 EXCEEDANCE. DECLARED EMERGENCY, LANDED WITHOUT…
- 25 Feb 2023
None, none
AC ESS BUSS OFF, DC 2 BUSS OFF, AC BUSS 2 OFF, FLAP FAIL, STEER FAIL, LGND, FCND, 17 CAUTION MSG, 18 OTHER MSG AIRCRAFT BEING MOVED TO HARDSTAND, ROUGHLY 30…
- 5 Dec 2022
Crossbeam, corroded
FRAME 14 CROSSBEAM HAS MULTIPLE AREAS OF CORROSION OUTBOARD OF THE R/H INBOARD SEAT TRACK BEAM AS MARKED. PERFORMED PERMANENT REPAIR ON CROSSBEAM FR 14 O/B OF…
- 13 Jan 2021
Battery, inoperative
AISLE EMERGENCY LIGHT NR 2 INOPERABLE. R & R FWD LT EMERGENCY LIGHT BATTERY, IAW AMM 33-50-01. OPERATIONS CHECK GOOD.
- 3 Mar 2020
Support Fitting, corroded
WHILE IN HEAVY CHECK - LH MONUMENT SUPPORT CORRODED AS MARKED FR 19. REMOVED AND REPLACED MONUMENT FITTING IAW SRM 51-40-08.
- 3 Mar 2020
Shear Tie, corroded
WHILE IN HEAVY CHECK - CORRODED SHEAR CLIP AT FRAME 88 STRINGER 27R. REMOVED AND REPLACED SHEAR CLIP
- 3 Mar 2020
Doubler, corroded
WHILE IN HEAVY CHECK - CORROSION ON DOUBLER AT FRAME 90 Y+10.748. REMOVED AND REPLACED DOUBLER AT FRAME 90 Y+10.748. REF EMB SRM 51-40-08.
- 22 Jun 2019
Power Supply, inoperative
EMERGENCY LIGHT INOPERATIVE CEILING AT ROW 15. R & R THE NR 3 BATTERY POWER UNIT IAW AMM 33-50-01.
- 1 Mar 2018
Power Supply, defective
AFT SERVICE DOOR FLOOR EXIT LIGHT IS INOPERATIVE. REMOVED AND REPLACED THE POWER SUPPLY IAW AMM 33-50-01. EMERGENCY LIGHT OP CHECKED GOOD IAW AMM 33-50-00.
- 21 Feb 2018
Door, corroded
WASTE SERVICING DOOR HAS SEVERAL AREAS OF CORROSION ON INTERNAL SURFACE. REMOVED AND REPLACED THE WASTE SERVICE DOOR IAW AMM 53-03-60, SRM 51-23-04, 51-23-05,…
- 16 Feb 2018
Support, corroded
AFT WET AREA RT PANEL SUPPORT AT FRAME 86 IS CORRODED. REMOVED AND REPLACED AFT WET AREA RT PANEL SUPPORT IAW SRM 51-40-08.
- 16 Feb 2018
Support, corroded
AFT WET AREA RT PANEL SUPPORT BRACKET AT FRAME 87 IS CORRODED. REMOVED AND REPLACED THE PANEL SUPPORT IAW SRM 51-40-08.
- 16 Feb 2018
Shear Panel, corroded
AFT WET AREA RT SHEAR PANEL BETWEEN FRAMES 87 AND 88 IS CORRODED. REMOVED THE SHEAR PANEL, LOCATED DRILLED, ALODINE NEW SHEAR PANEL, AND INSTALLED IAW SRM…
- 16 Feb 2018
Beam, corroded
AFT WET AREA RT BEAM AT FRAME 87 IS CORRODED. PERFORMED DOUBLER/FILLER REPAIR IAW SRM 53-23-10.
- 16 Feb 2018
Shear Panel, corroded
AFT WET AREA CENTER SHEAR PANEL BETWEEN FRAMES 87 AND 88 IS CORRODED. BLENDED CORROSION FOUND OUT OF LIMITS, REMOVED AND REPLACED THE SHEAR PANEL IAW SRM…
- 16 Feb 2018
Shear Panel, corroded
AFT WET AREA LT SHEAR PANEL BETWEEN FRAMES 87 AND 88 IS CORRODED. REMOVED AND REPLACED THE SHEAR PANEL IAW SRM 51-42-01, 51-42-02, 51-40-02, AND 51-23-04.
- 16 Feb 2018
Beam, corroded
AFT WET AREA LT BEAM AT FRAME 87 IS CORRODED. PERFORMED A DOUBLER, FILLER REPAIR IAW SRM 53-23-10.
- 16 Feb 2018
Splice, corroded
AFT WET AREA RT SPLICE AT FRAME 89 IS CORRODED. REMOVED AND REPLACED THE SPLICE IAW SRM 51-40-08.
- 16 Feb 2018
Splice, corroded
AFT WET AREA RT SPLICE AT FRAME 90 IS CORRODED. REMOVED AND REPLACED THE SPLICE IAW SRM 51-40-08.
- 16 Feb 2018
Splice, corroded
AFT WET AREA LT SPLICE AT FR 90 IS CORRODED. LOCATED, TREATED, PRIMED, PAINTED, AND INSTALLED NEW SPLICE IAW SRM 51-23-04, 51-23-05, 51-23-06, AND 51-40-08.
- 16 Feb 2018
Beam, corroded
AFT WET AREA LT BEAM AFT OF FRAME 90 IS CORRODED. COMPLIED WITH ETD2018-170-020644, INSTALLED A DOUBLER AND FILLER.
- 16 Feb 2018
Structure, corroded
AFT WET AREA WASTE WATER BOX IS CORRODED. REMOVED CORRODED BONDING PLATE FROM UPPER SURFACE OF VWS SERVICE PAN. LAYED UP AND CURED. TRIMMED REPAIR TO CONTOUR.…
- 16 Feb 2018
Beam, corroded
CORROSION ON THE L2 DOOR LOWER BEAM UNDER FWD ESCAPE SLIDE FITTING. REMOVED AND REPLACED THE BEAM IAW SRM 51-40-08.
- 16 Feb 2018
Seal, corroded
CORROSION FOUND FORWARD FUSELAGE WET AREA RIGHT AT FRAMES 13-14 JUST FORWARD OF SERVICE DOOR. REMOVED AND REPLACED FWD RT SEAL IAW SRM 51-40-08.
- 16 Feb 2018
Crossbeam, corroded
CORROSION FOUND AT CENTER OF FORWARD FUSELAGE FRAME 14 CROSSBEAM. REPAIRED THE CROSSBEAM IAW SRM 53-00-10.
- 16 Feb 2018
Seat Track, corroded
FWD FUSELAGE SEAT TRACK, FRAMES 13 - 14 AROUND NUTPLATES CORRODED. FOUND UNDER FLOOR BOARD 225ALF. REMOVED AND REPLACED THE SEAT TRACK IAW SRM 51-43-03,…
- 16 Feb 2018
Crossbeam, corroded
FWD FUSELAGE WET AREA FRAME 17 IN FRONT OF SERVICE DOOR RIGHT SIDE CORRODE. FOUND CORROSION TO BE GREATER THAN 10 % OUT OF LIMITS, CUT OUT DAMAGED PORTION,…
- 15 Feb 2018
Angle, corroded
SURFACE CORROSION ON BOTH LOWER ANGLES AND TWO CRACKED RECEPTACLES. BLENDED FOUND TO BE OUT OF LIMITS, REMOVED AND REPLACED LOWER ANGLE BRACKETS ON PANEL 1431…
- 15 Feb 2018
Closeout Panel, corroded
CORROSION ON CLOSE OUT PANEL AFT CARGO DOOR FRAMES 77-80 REMOVED AND REPLACED AFT CARGO CLOSE OUT PANEL REF TO WO H 6121 TASK 1064 FOR INSTALL.
- 14 Feb 2018
Angle, corroded
SURFACE CORROSION ON BOTH LOWER ANGLES ON PANEL 1441FR. REMOVED AND REPLACED LOWER ANGLES ON PANEL 1441FR IAW AMM 21-10-01.
- 30 Jan 2018
Light, inoperative
EMERGENCY LIGHT STRIP NEAR SEAT 1A HAS PLACES THAT DO NOT ILLUMINATE. R & R IAW AMM 33-50-21.
- 3 Sep 2017
Battery, inoperative
AFT CENTER EMERGENCY LIGHTS NOT WORKING. R & R THE BATTERY PACK, OPS CHECKED OK.
- 21 Dec 2016
Smoke Detector, false activation
DURING FLIGHT, AFT LAVATORY SMOKE DETECTOR ACTIVATED. FLIGHT ATTENDANT NOTED PASSENGER STANDING OUTSIDE AFT LAVATORY WITH LAVATORY DOOR OPEN. FLIGHT ATTENDANT…
- 4 Aug 2016
Door, out of sequence
CREW REPORTED THAT THE L1 DOOR WOULD NOT OPEN. MAINTENANCE RE-SEQUENCED L1 DOOR IAW AMM AND OPS CHECKED GOOD.
- 20 Jul 2015
Battery Pack, inoperative
CREW REPORTED THAT THE AFT EMERGENCY CEILING LIGHT WOULD NOT ILLUMINATE. MAINTENANCE R & R EMERGENCY BATTERY IAW AMM AND OPS CHECKED GOOD.
- 20 Mar 2015
Flashlight, inoperative
CREW REPORTED THAT THE AFT F/A FLASHLIGHT WAS INOPERATIVE. MAINTENANCE R & R AFT F/A FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.
- 11 Jan 2014
Sensor, failed
CREW RECEIVED "STEERING FAIL" MESSAGE ON ROLLOUT BUT WAS ABLE TO CLEAR THE RUNWAY AND STOP ON TAXIWAY. MAINTENANCE R & R THE FEEDBACK SENSOR AMM. ACFT IS GOOD…