N411US
1981 Piper PA-31-350 standard FAA →
registration
- 1981
earlier registrations
1 past record
- 1988
service difficulty reports
28 reports
- 27 Aug 2002
Skin, cracked
CLT - FOUND SKIN CRACKED 3 INCHES, STATION BS 727D STRINGER 23R. INSTALLED DOUBLER PER TR 53-60-03. (M)
- 15 Aug 2001
Skin
CLT - FOUND SKIN OIL CAN IN AFT PRESSURE BULKHEAD, BS 1016. INSTALLED DOUBLER PER SRM 53-80-08 FIG 201. (M)
- 16 Jul 2000
Charger, failed
ALB - MAINTENANCE FOUND THE FOLLOWING EMERGENCY LIGHTS INOPERATIVE, BOTH SIDEWALL EXIT LIGHTS FOR THE AFT ENTRY DOOR, CEILING EXIT SIGN FOR AFT GALLEY, EXIT…
- 2 Jul 2000
Battery Pack, discharged
TPA - MAINTENANCE FOUND THE CABIN EMERGENCY LIGHTS INOPERATIVE FROM THE LEFT EMERGENCY EXIT AND AFT. ALSO, FOUND THE LEFT AFT SERVICE DOOR EXTERIOR EMERGENCY…
- 17 Apr 2000
Fuse, failed
MIA - MAINTENANCE FOUND THE AFT LEFT OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE FUSE IN THE M1479 POWER SUPPLY MODULE.…
- 14 Mar 2000
Charger, failed
LGA - MAINTENANCE FOUND THE LEFT AFT OVERWING (INTERIOR AND EXTERIOR) EMERGENCY EXIT LIGHTING INOPERABLE. LGA - MAINTENANCE REMOVED AND REPLACED THE BATTERY…
- 11 Jun 1999
Irs, failed
ROC - FLT 1886 - AFTER TAKEOFF, CREW REPORTED LOSING HEADING INDICATOR. CREW ACCOMPLISHED SPECIAL PROCEDURES, BUT FAILED TO REST. CAPTAIN ELECTED TO RETURN TO…
- 12 Feb 1999
Floorbeam, corroded
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND CORROSION AT TOP SURFACE 'T' CAP STATION 312 LBL 40 - LBL 36 FLOORBEAM. REPAIRED ANGLES 'T' CAP PER SRM…
- 12 Feb 1999
Skin, corrosion
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND CORROSION 2 INCH BY 4 INCH BS 795 BL 0 ON SKIN. REPAIRED DOUBLER EXTERNAL PER SRM 53-00-01. (M)
- 12 Feb 1999
Floorbeam, corroded
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND CORROSION 8 INCH STATION 328 LBL 12 FLOORBEAM. REPAIRED 'T' CAP SLICE PER SRM 53-10-51 FIG 205. (M)
- 12 Feb 1999
Floorbeam, corroded
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 8 INCH CORROSION AT STATION 312 LBL 12 FLOOR SUPPORT. REMOVED AND REPLACED SUPPORT PER SRM 51-10-2. (M)
- 12 Feb 1999
Floorbeam, corroded
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND CORROSION AT NUTPLATE HOLES STATION 967 LBL 16 - LBL 50 FLOORBEAM. CORROSION TASK NR C53-107-02. INSTALLED…
- 12 Feb 1999
Floorbeam, corroded
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A 30 INCH AREA OF CORROSION STATION 344 FLOORBEAM. SPLICED IN 'T' CAP AND DOUBLER PER SRM 53-10-51. (M)
- 12 Feb 1999
Cargo Track, corroded
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY 3 INCH AREA OF CORROSION BS 947.5 LBL 14.5 AFT CORNER CARGO TRACK TIE DOWN CHANNEL. CORROSION TASK…
- 12 Feb 1999
Cargo Track, corroded
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 16 INCH AREA OF CORROSION BS 767-867 RBL 14.5 CARGO TRACK TIE DOWN CHANNEL. CORROSION TASK NR…
- 12 Feb 1999
Floorbeam, corroded
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND CORROSION BS 986 FLOORBEAM UPPER T-CAP BETWEEN LLBL 29 AND RLBL 29. CORROSION TASK NR C53-107-02. REPAIRED PER…
- 12 Feb 1999
Angle, cracked
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A 2 INCH CRACK STRINGER 12R STATION 1141 ANGLE RADIUS. SPLICED ANGLE PER SRM 51-70-11. (M)
- 12 Feb 1999
Floorbeam, corroded
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY 2 INCH CORRODED AREA AT BS 859 RBL 25 LBL 25 FLOOR SUPPORT. CORROSION TASK NR C53-202-01.…
- 29 Sep 1998
Panel, leaking
PBI - FLT 1908 - FLT WAS DELAYED FOR 4 HOURS IN MIA FOR FUEL LEAK REPAIR. AFTER TAKEOFF FROM MIA, F/A NOTICED FUEL LEAKING FROM LEFT WING AND SPRAYING OFF THE…
- 19 Mar 1998
Adi, failed
PIT - FLT 1498 - UPON CLIMB-OUT FROM PIT, CAPTAINS ATTITUDE INDICATOR FAILED. DECISION WAS MADE TO RETURN TO FIELD AT PIT. FLIGHT LANDED WITHOUT FURTHER…
- 15 Feb 1998
Battery Pack, discharged
EWR - MAINTENANCE FOUND THE EMERGENCY EXIT LIGHTS ON SEAT ROWS 20 THROUGH 24 AND THE AFT DOORS INOP. MAINTENANCE REMOVED AND REPLACED THE AFT RIGHT BATTERY…
- 23 Jan 1998
Battery Pack, discharged
CLT - MAINTENANCE FOUND THE MID-CABIN EMERGENCY EXIT LIGHTS WEAK DURING OPERATIONAL CHECK OF EMERGENCY LIGHT SYSTEM. MAINTENANCE REMOVED AND REPLACED THE…
- 6 Jan 1998
Power Supply, inoperative
CLE - MAINTENANCE FOUND THE SEAT ROW EMERGENCY LIGHTS INOPERABLE AT ROWS 1 AND 2. MAINTENANCE REMOVED AND REPLACED THE POWER SUPPLY AND BATTERY PACK.…
- 6 Jan 1998
Battery Pack, discharged
CLE - MAINTENANCE FOUND THE SEAT ROW EMERGENCY LIGHTS INOPERABLE AT ROWS 1 AND 2. MAINTENANCE REMOVED AND REPLACED THE POWER SUPPLY AND BATTERY PACK.…
- 10 Aug 1997
Fan Blade, bent
DAB - FL2308 - AFTER T/O AT APPROX 100 FT, THE RIGHT ENGINE HAD EXCESSIVE VIBRATION, ALL OTHER INDICATIONS WERE NORMAL. THE DECISION WAS MADE TO RETURN TO…
- 30 Nov 1996
Adi, failed
PVD - FL 155, FIRST OFFICERS ADI FAILED. FLIGHT RETURNED TO PVD AND LANDED WITH NO FURTHER INCIDENT. MAINTENANCE REPLACED THE ADI. (M)
- 4 Feb 1995
Bellcrank, worn
MLB - FLT 1926 - DURING MISSED APPROACH AT MCO. FLAPS WOULD NOT RETRACT. FLIGHT DIVERTED TO MCO WHERE LANDING WAS WITHOUT INCIDENT. MAINTENANCE INSPECTED ALL…
- 22 Dec 1994
Eel, inoperative
BOS - SERVICE DOOR EMERGENCY LIGHT INOPERATIVE. MAINTENANCE RELAMPED. (W)