N410SW
1995 Canadair CL-600-2B19 standard FAA →
earlier registrations
1 past record
- 1995
service difficulty reports
141 reports
- 23 Nov 2013
Structure, dented
SMALL DENT ON LOWER LT SIDE OF MCD SURROUND. FLT 3494 INSTALLED NEW DOUBLER IAW REO.
- 18 Sep 2013
Drag Brace, failed
ON DEPARTURE RECEIVED GEAR DISAGREE WARNING MESSAGE & NOSE DOOR OPEN WARNING MESSAGE WHEN LG WAS SELECTED UP. FOLLOWED QRH, COMPLIED WITH MANUAL GEAR…
- 15 Sep 2013
Selector Valve, failed
SELECTING GEAR UP GEAR DISAGREE & NOSE DOOR OPEN WARNINGS WITH NOSE GEAR DOWN INDICATION, COMPLIED WITH QRH ALL 3 GEARS CAME DOWN. FLT#6356 REPLACED NLG…
- 8 Sep 2013
Wire Harness, failed
GEAR DISAGREE UPON GEAR RETRACTION. NOSE GEAR DID NOT RETRACT. COMPLETED QRH PROCEDURE. FLT#6202 REPLACED THE PS2GA DOWNLOCK NR 2 HARNESS FOR THE NLG IAW AMM.…
- 31 Aug 2013
Power Supply, discharged
EMERGENCY LIGHTS DIM QUICKLY. FLT#5248 RECHARGED EMERGENCY LIGHTS POWER SUPPLY.
- 30 Aug 2013
Priority Valve, failed
ON TAKEOFF NOSE GEAR DID NOT RETRACT. FLT#5261 REPLACED NLG PRIORITY VALVE IAW AMM. PN 4622, SN ON 739A & SN OFF 2214A.
- 24 Aug 2013
Downlock Sensor, out of adjust
ON DEPARTURE NOSE GEAR DID NOT RETRACT. FLT#5539 FOUND DOWN LOCK NR 2 SENSOR OUT OF ADJUSTMENT. RIGGED NR 2 DOWN LOCK SENSOR. ADJUSTED OLEO EXTENDED &…
- 29 Jul 2013
Light, inoperative
EMERGENCY OVERHEAD LIGHT BURNED. FLT#6228 RELAMPED.
- 10 Jun 2013
Light, inoperative
NR 1 EMERGENCY OVERHEAD LIGHT IS BURNED OUT. RELAMPED.
- 26 Jan 2013
Light, inoperative
NR 1 EMERGENCY OVERHEAD LIGHT BURNED OUT. (FLT 5240) RELAMPED EMERGENCY LIGHT.
- 8 Dec 2012
Switch, defective
LEFT PACK OVERHEATING, MAKING LOUD NOISE AND SMELLS LIKE SMOKE. (FLT 5647) REPLACED LEFT ACM TEMP SWITCH, REPLACED CONNECTOR TO LEFT ACM TEMP SWITCH AND…
- 14 Sep 2012
Light, inoperative
AFT OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 4820) RELAMPED EMERGENCY LIGHT.
- 1 Jul 2012
Relay, failed
EMERGENCY LIGHT IS ON WHEN IN THE ARMED POSITION. (FLT 4844) REPLACED K1XD RELAY.
- 1 Jul 2012
Light, inoperative
NR 2 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 4844) RELAMPED EMERGENCY LIGHT.
- 22 May 2012
Light, inoperative
NR 2 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 4511) RELAMPED EMERGENCY LIGHT.
- 1 May 2012
Light, inoperative
RIGHT SIDE FORWARD EMERGENCY LIGHT IS OUT. (FLT 7766) RELAMPED EMERGENCY LIGHT.
- 23 Apr 2012
Restrictor, dirty
HYDRAULIC 3 LOW PRESSURE CAUTION UPON SELECTION OF LANDING GEAR TO THE DOWN POSITION AND LANDING GEAR SEEMED SLOW TO EXTEND. (FLT 4543) PURGED AIR FROM…
- 4 Feb 2012
Light, inoperative
EMERGENCY LIGHTS IN CABIN AT ROW 8 ARE OUT. (FLT 4666) RELAMPED EMERGENCY LIGHTS.
- 16 Jan 2012
Light, inoperative
NR 1 MAIN CABIN DOOR EXTERNAL EMERGENCY LIGHT IS OUT. (FLT 4575) RELAMPED EMERGENCY LIGHT.
- 30 Nov 2011
Channel, cracked
LEFT AND RIGHT FS 409+128 VERTICAL POSTS OUTBOARD C-CHANNELS ARE CRACKED. (C-CHECK) REPAIR PER REO.
- 26 Oct 2011
Actuator, failed
HYD 3 LOW PRESS CAUTION MESSAGE. ON GEARS RETRACTION RECEIVED NOSE GEAR DISAGREE WARN FOR ABOUT 30 SEC. (FLT 4571) REPLACED NLG RETRACT ACTUATOR. P/N OFF…
- 26 Sep 2011
Priority Valve, failed
GEAR DISAGREE WARNING MESSAGE ON GEAR RETRACTION. (FLT 4522) REMOVED AND REPLACED NR 3A ACMP AND NOSE LANDING GEAR PRIORITY VALVE. P/N ON 848847, S/N OFF…
- 17 Jun 2011
Pin, lack of lube
MAIN CABIN DOOR DIFFICULT TO OPEN. (FLT 4656) LUBED DOOR LATCH PINS.
- 18 Mar 2011
Pin, bent
MAIN CABIN DOOR PLUNGER HARD TO OPERATE. (FLT 4684) STRAIGHTENED ICE BREAK DOOR PLUNGER PIN.
- 2 Mar 2011
Light, inoperative
LEFT FORWARD EXTERIOR EMERGENCY LIGHT IS OUT. (FLT 4558) RELAMPED EMERGENCY LIGHT.
- 16 Jun 2010
Light, inoperative
AFT CEILING EMERGENCY FLOODLIGHT INOP. (FLT 4725) RELAMPED EMERGENCY LIGHT.
- 7 Jan 2010
Floorbeam, chafed
C-CHECK, LANDING GEAR ALTERNATE RELEASE CABLE PULLEY CHAFING ON FS 280 BEAM. REPAIRED PER REO.
- 5 Jan 2010
Angle, cracked
LBL 18 CAP ANGLE RADIUS CRACKED. (C CHECK) REPAIRED PER REO.
- 4 Jan 2010
Floorbeam, cracked
DURING C-CHECK, FS 280 BEAM CRACKED. REPAIRED PER REO.
- 4 Jan 2010
Angle, cracked
LEFT WING BATT ANGLE AT WS 53 AND WS 48 CRACKED. (C CHECK) REPAIRED PER REO.
- 3 Jan 2010
Vertical Beam, cracked
C-CHECK, AFT TOP RIGHT VERTICAL BEAM CRACKED AT FASTENER. REPAIRED PER REO.
- 31 Dec 2009
Bulkhead, cracked
FS 621 BULKHEAD CRACKED BELOW SPLICE STRAP. (C CHECK) REPAIRED PER REO.
- 31 Dec 2009
Frame, cracked
FUSELAGE FRAME AT FS 605 ABOVE CARGO DOOR CRACKED. (C CHECK) REPAIRED PER REO.
- 22 Oct 2009
Selector Valve, failed
NOSE GEAR DID NOT RETRACT. (FLT 4780) REPLACED NOSE GEAR SELECTOR VALVE. P/N: 750006000, S/N ON: 1731, S/N OFF: 1902.
- 4 Oct 2009
Light, inoperative
EMERGENCY LIGHT AT SERVICE DOOR INOP. (FLT 4865) REPLACED LIGHT ASSEMBLY.
- 28 Sep 2009
Light, inoperative
OVERHEAD LIGHT POD NR 2 NOT WORKING. (FLT 4451) REPLACED NR 2 OVERHEAD EMERGENCY LIGHT.
- 21 Sep 2009
Light, inoperative
MAIN CABIN DOOR EMERGENCY EXIT LIGHT INOP. (FLT 4726) RELAMPED EMERGENCY LIGHT NEAR MCD EXTERIOR.
- 21 Sep 2009
Light, inoperative
RIGHT OVERWING EMERGENCY FORWARD LIGHT INOP. (FLT 4726) RELAMPED RIGHT OVERWING EXTERIOR EMERGENCY LIGHT (FWD).
- 2 Aug 2009
Door, binds
MAIN CABIN DOOR DIFFICULT TO OPEN. (FLT 4731) OPERATIONAL CHECK NORMAL.
- 31 Jul 2009
Light, inoperative
LEFT FORWARD EXTERIOR EMERGENCY LIGHT INOP. (FLT 4722) RELAMPED EMERGENCY LIGHT.
- 29 Jan 2009
Light, broken
FLT 4717 - PASSENGER DOOR EMERGENCY FLOOD LIGHT BROKEN INTO PIECES. REPLACED FLOOD LIGHT ASSEMBLY.
- 9 Sep 2008
Lamp, burned out
EMERGENCY LIGHT BULB IN CEILING ROW 3 IS INOP. RELAMPED.
- 30 Apr 2008
Support Angle, cracked
STA 621 LT - SUPPORT ANGLE FROM PRESS BLKHEAD TO FLOOR CRACKED AT OUTBOARD END. FOUND AT C-CHECK. REPAIRED PER REO 601R-53-61-117.
- 30 Apr 2008
Attach Fitting, cracked
CRACK INDICATIONS NOTED AT AFT PRESSURE BULKHEAD LINTEL ATTACHMENT FITTING UPPER AND LOWER CORNER AREA. FOUND AT C-CHECK. REPAIRED PER REO 601R-53-61-1230 REV…
- 30 Apr 2008
Bulkhead, cracked
CRACK INDICATION NOTED ON AFT PRESSURE BULKHEAD LBL 36.20 JUST ABOVE LOWER LINER ATTACH CLIP. FOUND AT C-CHECK. REPAIRED PER REO 601R-53-61-1285 SHEET 11.
- 30 Apr 2008
Skin, cracked
FS 559 UNDER RT SIDE LT AILERON HAS CRACKS IN WEB FOUND AT C-CHECK. REPAIRED PER REO 601R-53-41-260 STEP 13 A-E STEP 14 C,C REV "B".
- 30 Apr 2008
Floor Support, corroded
RT AND LT CABIN FLOOR LINE STRUCTURE CORRODED FROM STA 424RT - 559RT. FOUND AT C-CHECK. REPAIRED PER REO 601R-53-41-724.
- 1 Mar 2008
Handle, worn
FLT 3858 - PASSENGER DOOR HANDLE WILL NOT STOW. REPLACED PAX DOOR OUTER HANDLE ASSEMBLY IAW AMM 52-11-03. OPS CHECK GOOD.
- 4 Aug 2007
Line, leaking
HYDRAULIC SYSTEM NR 3 FLUID LEVEL IS 0%, FLIGHT NR 3763. REPLACED NOSE GEAR ACTUATOR AND PUMP 3B PRESSURE FLEXLINES IAW 32-33-01 AND 29-12-03. SERVICED NR 3…
- 20 Jul 2007
Strut, binding
FLT 3865 - MAIN CABIN DOOR DOES NOT OPEN FREELY. REPLACED AFT PAX DOOR STRUT IAW AMM 52-11-17, PN: 601R31911-9.
- 29 Mar 2007
Wire, burned
RECEIVED MULTIPLE CAUTION MESSAGES. THE NR 2 MFD, PFD AND THE RTU WENT DARK. REPLACED BURNED WIRES AND TERMINALS FROM CBP2 TO JB1 IAW WM 20-12-00. OPERATIONAL…
- 17 Feb 2007
Windshield, cracked
CAPTAIN'S WINDSHIELD CRACKED CLIMBING THROUGH FL 260. CAPTAIN’S WINDSHIELD INSTALLED IAW RII 56-220-1000 AND AMM 56-11-01. OPERATIONAL AND LEAK CHECKS GOOD.
- 16 Feb 2007
Windscreen, cracked
FIRST OFFICER'S WINDSCREEN SHATTERED ON PUSH BACK. REPLACED FIRST OFFICER'S WINDSCREEN IAW AMM 56-11-01 AND RII 56-220-1000, PN OFF: NP-139321-6, SN OFF: NSN.
- 13 Feb 2007
Lamp, burned out
AFT EMERGENCY CEILING LIGHT INOP. REPLACED LAMP IN AFT CEILING EMERGENCY LIGHT AS NEEDED. OPERATIONAL CHECKS GOOD.
- 7 Sep 2006
Light, inoperative
LOWER EXIT SIGN/LIGHT AT SERVICE DOOR INOP. REPLACED LOWER SERVICE DOOR LIGHT. OPERATIONAL CHECKS GOOD, PN: 6020-5.
- 29 Jul 2006
Strut, low
AFTER TAKEOFF GOT GEAR UP DISAGREE AND THE NOSE GEAR WAS STILL DOWN. RETURNED TO FIELD. PERFORMED NOSE SHOCK STRUT SERVICE IAW ST 12-710-002. OPERATIONAL…
- 11 Jul 2006
Pin, corroded
LEFT OVERWING EMERGENCY EXIT BOTH HOOK FITTING PINS CORRODED, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED LT OVERWING EMERGENCY EXIT HOOK FITTING PINS PER…
- 11 Jul 2006
Pin, corroded
RT OVERWING EMERGENCY EXIT BOTH HOOK FITTING PINS CORRODED, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED RT OVERWING EMERGENCY EXIT HOOK FITTING PINS PER…
- 11 Jul 2006
Bracket, corroded
FLOOR SUPPORT BRACKET CORRODED UNDER CABIN FLOOR PNL 251CLF LOCATED NEAR AFT DOOR SILL, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED NEW BRACKET P/N…
- 11 Jul 2006
Plate, cracked
HANDLE MOUNT PLATE IS CRACKED ON 2ND STEP OF PAX DOOR, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED NEW MOUNTING PLATE AND REINSTALLED 'T' KNOB PER CRJ200…
- 11 Jul 2006
Angle, cracked
ANGLE CRACKED AT STA 624 (AFT SIDE OF PRESSURE BULKHEAD) WL79 RBL40, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED NEW ANGLE P/N 601R-35012-52 PO 64041 AS…
- 11 Jul 2006
Channel, cracked
'C' CHANNEL CRACKED AT WING STATION 75.5 UNDER LT I/B GROUND SPOILER, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED NEW 'C' CHANNEL P/N 601R-10224-13 PO…
- 11 Jul 2006
Drag Angle, cracked
TWO CRACKS IN AFT DRAG ANGLE ON PAX DOOR, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED ANGLE SECTION AND SPLICE ANGLES ON PAX DOOR AFT DRAG ANGLE IAW REO…
- 19 Jun 2006
Light, inoperative
SECOND CEILING LEVEL EMERGENCY FLOOD LIGHT INOP. REPLACED SECOND CEILING EMERGENCY LIGHT LAMP. OPERATIONAL CHECKS GOOD, PN 1317.
- 25 Jan 2006
Pcu, malfunctioned
ON TAXI IN AT SLC, SPOILERON FAULT STATUS MSG. REPLACED LEFT OUTBD SPOILERON PCU IAW CRJ 200 MM 27-62-01. OPERATIONAL CHECK OK, PN 27000-7 SN OFF MAL 437.
- 4 Aug 2005
Control Unit, malfunctioned
FFOD CHECKS STAB TRIM CH 1 INOPERATIVE. REPLACED HSTA AND MCU IAW 33-27-415 AND MM 27-40-00, 27-42-01, 27-42-05. OPERATIONAL CHECK GOOD, PN 8396-3 SN OFF 1087.
- 13 Jun 2005
Trim Switch, sticks
CAPT YOKE STAB TRIM SWITCH STICKS. REPLACE TRIM SWITCH IAW MM 27-44-03. OPERATIONAL CHECK GOOD.
- 11 May 2005
Actuator, malfunctioned
STAB TRIM CHANNEL TWO WOULD NOT ENGAGE. REPLACED HSTCA IAW 27-42-01 AND MCU IAW 27-42-05. OPERATIONAL CHECK GOOD.
- 8 May 2005
Switch, inoperative
STAB TRIM CH 2 INOP. REPLACED CAPT'S STAB DISCONNECT SWITCH IAW CRJ MM 27-41-30, OPERATIONAL CHECK GOOD.
- 7 May 2005
Control Unit, malfunctioned
STAB TRIM CH 2 INOPERATIVE. REPLACED STAB TRIM ACTUATOR AND MOTOR CONTROL UNIT IAW 27-42-01. OPERATIONAL CHECK GOOD, PN: 8396-3 SN OFF: 843.
- 18 Nov 2004
Beam, cracked
FUSELAGE UPPER FLANGE ON TRANSVERSE BEAM IS CRACKED; FS 280.00, RBL 9.0, ITEM FOUND AT C-CHECK INSPECTION. REPAIRED IAW CRJ REO 60R53-11-13 REV "NC" RII 53-401.
- 18 Nov 2004
Door Frame, corroded
PAX DOOR FORWARD AND AFT LOWER CORNERS FRAMES CORRODED, ITEM FOUND AT C-CHECK INSPECTION. CORNER FITTINGS REPLACED IAW CRJ REO 601R52-11-0600, REO…
- 18 Nov 2004
Angle, cracked
FUSELAGE; PULLEY INTERTCOSTAL HAS A CRACKED REMOTE ANGLE FS 484.00; LBL-27.0, ITEM FOUND AT C-CHECK INSPECTION. REPLACED CLIP IAW CRJ REO 601R53-41-059 REV…
- 18 Nov 2004
Beam, cracked
VERTICAL BEAM AT FS 409+128 LBL 27 INBOARD SIDE CRACKED, ITEM FOUND AT C-CHECK INSPECTION. REPAIRED IAW CRJ REO 601R-53-41-056 REV "C.
- 18 Nov 2004
Vertical Beam, cracked
VERTICAL BEAM AT FS 409+128 RBL 27 INBOARD SIDE CRACKED, ITEM FOUND AT C-CHECK INSPECTION. REPAIRED IAW CRJ REO 601R-53-41-056 REV. "C".
- 18 Nov 2004
Frame, corroded
CORROSION ON FRAME 349.0 STR 26L AND ON FRAME 364.0 STR 26L IN AVIONICS CRAWL WAY. (ITEM FOUND AT C-CHECK INSPECTION.) AFFECTED AREAS REPAIRED IAW CRJ SRM…
- 18 Nov 2004
Riser, corroded
PAX DOOR SILL RISER CORRODED IN SEVERAL LOCATIONS. (ITEM FOUND AT C-CHECK INSPECTION.) AFFECTED AREAS REPAIRED IAW CRJ SRM 53-21-23
- 18 Nov 2004
Intercostal, corroded
MAIN AVIONICS COMPARTMENT INTERCOSTAL STR 26L BETWEEN FS 349 AND FS 364 CORRODED. (ITEM FOUND AT C-CHECK INSPECTION.) CORRODED SECTION OF INTERCOSTAL BLENDED…
- 18 Nov 2004
Frame, cracked
PAX DOOR 7 INCHES ABOVE DATUM 1 AT FS 320.1 AND 338.9 FORMERS ARE CRACKED. (ITEM FOUND AT C-CHECK INSPECTION.) REPAIRED IAW CRJ REO 601R-52-11-609.
- 18 Nov 2004
Web, cracked
PAX DOOR BOTTOM STEP LOWER WEB CRACKED. ITEM FOUND AT C-CHECK INSPECTION. REPAIRED IAW CRJ SRM 51-71-59.
- 18 Nov 2004
Rib, cracked
LEFT PYLON AFT RIB IS CRACKED; FS 605.00, ITEM FOUND AT C-CHECK INSPECTION. REPAIRED RIB IAW SRM 51-40-11, 51-42-06, 51-42-21, 51-23-00.
- 18 Nov 2004
Clip, cracked
AFT EQUIPMENT COMPARTMENT INTERCOSTAL CLIP IS CRACKED; FS 625.00 STR 14L, ITEM FOUND AT C-CHECK INSPECTION. REPLACED CLIP CRJ SRM 51-40-11, 51-42-06, 51-25-16.
- 18 Nov 2004
Clip, cracked
AFT EQUIPMENT COMPARTMENT INTERCOSTAL CLIP IS CRACKED; FS 625.00 STR 14R, ITEM FOUND AT C-CHECK INSPECTION. REPLACED CLIP IAW CRJ SRM 51-40-11, 51-42-06,…
- 18 Nov 2004
Frame, cracked
AFT EQUIPMENT COMPARTMENT FRAME IS CRACKED; FS 640.00 STR 9L, ITEM FOUND AT C-CHECK INSPECTION. REPAIRED IAW CRJ REO 601R-53-61-557 REV "NC"
- 18 Nov 2004
Frame, cracked
AFT EQUIPMENT COMPARTMENT FRAME IS CRACKED; FS 640.00 STR 9R, ITEM FOUND AT C-CHECK INSPECTION. FRAME REPAIRED IAW REO 601R-53-61-557 REV NC.
- 18 Nov 2004
Fitting, corroded
HORIZONTAL STAB ANTI-ROTATION FITTING CORRODED, ITEM FOUND AT C-CHECK INSPECTION. HORIZONTAL STAB ANTI-ROTATION FITTING REPLACED IAW SB 601R-55-007.
- 18 Nov 2004
Web, cracked
LEFT HORIZONTAL STAB WEB CRACKED FROM LIGHTNING HOLE AT LBL 58.92 AND STRINGER NR 2, ITEM FOUND AT C-CHECK INSPECTION. REPAIRED LT HORIZONTAL STAB, WEB AT LBL…
- 18 Nov 2004
Floor Support, cracked
CARGO PIT FLOOR SUPPORT LBL 27.0 CRACKED AT 3 LOCATIONS INBOARD SIDE BETWEEN FS 574.0 TO 621.0, INBOARD WEB BUCKLED BETWEEN FS 574.0 TO FS 589.0. ITEM FOUND…
- 18 Nov 2004
Plate, corroded
CARGO PIT; CARGO DOOR ENTRY LANDING PLATE HAS CORROSION AROUND A/NUT LOCATIONS, UPPER AND LOWER SURFACES AT FS 574.0 TO 621.0 LBL 42, ITEM FOUND AT C-CHECK…
- 30 Oct 2004
Bulb, burned out
THIRD AFT EMERGENCY CEILING LIGHT INOPERATIVE. REMOVED AND REPLACED 3RD AFT CEILING EMERGENCY LIGHT BULB. OPERATIONAL CHECK GOOD IAW MM 33-00-00.
- 1 Oct 2004
Control Unit, malfunctioned
FLAP FAIL MESSAGE DURING FLAP RETRACTION OUT OF SLC. RETURN TO FIELD. REPLACED FECU IAW MM 27-51-05 AND LEFT NR 5 FLAP FLEX SHAFT IAW CRJ 200 MM 27-53-10.…
- 6 Sep 2004
Actuator, malfunctioned
FIRST FLIGHT OF DAY TRIM CHECK, STAB TRIM 2 FAILED. REMOVED AND REPLACED BOTH HST AND MOTOR CONTROL UNIT IAW MM 27-42-01, 27-42-05. OPERATIONAL CHECK GOOD.…
- 11 Aug 2004
Control Unit, malfunctioned
ON SHORT FINAL WHILE RUNNING STAB TRIM, STAB AND MACH TRIM CAUTION MESSAGE DISPLAYED. REMOVED AND REPLACED HSTCU IAW AMM 27-41-01. OPERATIONAL CHECK GOOD.
- 25 Jul 2004
Trim Switch, malfunctioned
STABILIZER TRIM (BOTH CHANNELS) DISENGAGED DURING CLIMB. REMOVED AND REPLACED F/O'S TRIM SWITCH. OPERATIONAL CHECK GOOD IAW MM 27-41-05 AND 27-40-00.
- 9 Jun 2004
Loop, malfunctioned
INFLIGHT FROM OAK TO SLC LEFT 14TH DUCT MSG POSTED, SHUTDOWN LEFT ENGINE. REMOVED AND REPLACED LEFT 14TH STAGE PYLON LOOP WITH SERVICEABLE UNIT IAW MM…
- 6 May 2004
Control Unit, malfunctioned
ON DESCENT INTO SLC THE A/C PITCHED UP AND GAVE A AP PITCH TRIM & NOSE UP TRIM CAUTION. STAB TRIM AND MACH TRIM DROPPED OFF 3 TIMES. NOTE: WITH AUTO PILOT OFF…
- 10 Apr 2004
Actuator, malfunctioned
RUDDER TRIM CB 2F6 POPPED. REMOVED AND REPLACED RUDDER TRIM ACTUATOR IAW MM 27-22-01. OPS CHECK GOOD.
- 21 Feb 2004
Actuator, malfunctioned
F/O TRIM DISCONNECTS BOTH STABS AND MACH TRIMS. REMOVED AND REPLACED HSTA. FUNCTION CHECK SATISFACTORY IAW CRJ MM 27-42-01.
- 21 Dec 2003
Computer, malfunctioned
AP PITCH TRIM CAUTION MESSAGE AT 6500 FEET MSL (2300 AGL) ON FINAL. REMOVED AND REPLACED FCC 4000 CARDS 1A & 2A IAW MM 22-12-14. OPS CHECK GOOD. P/N:…
- 21 Apr 2003
Floor Panel, cracked
FS 193 ELECTRICAL BAY RT FLOOR CRACKED. DISCOVERED DURING C-CHECK. REPAIRED DAMAGE IAW CRJ REO 601R-53-11-245 REV NC.
- 21 Apr 2003
Floorbeam, cracked
FS 280 PILOT'S BULKHEAD LBL 90 AFT FLOOR ANGLE CRACKED. DISCOVERED DURING C-CHECK. REPAIRED DAMAGED AREA IAW CRJ REO 601R-53-11-138 NC.
- 21 Apr 2003
Skin, cracked
FS 235 FUSELAGE SKIN RBL 6.0 NLG CUTOUT CRACKED. DISCOVERED DURING C-CHECK. REPAIRED DAMAGED AREA IAW CRJ REO 601R-53-11-048 REV B.
- 21 Apr 2003
Skin, cracked
FS 235 FUSELAGE SKIN LBL 6.0 NLG CUTOUT CRACKED. DISCOVERED DURING C-CHECK. DAMAGE REPAIRED IAW CRJ REO 601R-3-11-048 REV B.
- 21 Apr 2003
Sill, corroded
SERVICE DOOR SILL PLATE CORRODED. DISCOVERED DURING C-CHECK. DAMAGE FOUND TO BE OUT OF LIMITS. REPLACED SERVICE DOOR SILL PLATE WITH NEW PART IAW CRJ SRM…
- 21 Apr 2003
Intercostal, cracked
FS 484 RT INTERCOSTAL O/B FLG RBL 3G CRACKED. DISCOVERED DURING C-CHECK. INTERCOSTAL REPAIRED IAW CRJ REO 601R-53-11-059.
- 17 Nov 2002
Controller, malfunctioned
AFTER TAKEOFF WE RECEIVED RIGHT AOA HEAT, R STATIC HEAT, R PITOT HEAT AND TAT PROBE HEAT CAUTION MESSAGES. RETURNED TO SLC. REMOVED AND REPLACED THE RIGHT…
- 31 May 2002
Fire Loop, chafed
RECEIVED RIGHT 14TH STAGE DUCT LEAK WARNING CLIMBING THROUGH 7000 FT. AS PER QRH, RETARDED RIGHT ENGINE THRUST TO IDLE. AFTER 40 SECONDS STILL HAD THE…
- 5 May 2002
Check Valve, malfunctioned
LEFT PACK FAILED INFLIGHT. RIGHT PACK DEFERRED. PERFORMED EMERGENCY DESCENT PROCEDURE PER QRH. LEFT PACK HEAT EXCHANGER CHECK VALVE HINGE AND SPRING WORN.…
- 6 Apr 2002
Filter, dirty
''DISPLAY COOL'' CAUTION MESSAGE DURING FLIGHT. MESSAGE PERSISTED AFTER 1ST STEP PER QRH. MESSAGE WENT AWAY AFTER SWITCHING TO STBY. RETURNED TO SLC. REMOVED…
- 30 Jan 2002
Warning System, malfunctioned
GEAR DISAGREE ON TAKEOFF. NOSE GEAR WOULD NOT COME UP. INSPECTED NOSE GEAR TORQUE LINKS, PROX SWITCHES AND STEERING. NO DEFECTS NOTED. JACKED A/C NOSE, SWUNG…
- 24 Jan 2002
Landing Gear, malfunctioned
NOSE GEAR WOULD NOT RETRACT AFTER TAKEOFF. CREW NOTED CHUNK OF ICE FELL FROM GEAR WHEN DOORS OPENED. PERFORMED NOSE GEAR RETRACTION TEST PER MM 32-30-00. NO…
- 3 Dec 2001
Power Cable, contaminated
CABIN FLOOR EMERGENCY LIGHT FWD SECTION INOP. FOUND ONE LAMP SECTION BAD. REPLACED LAMP. FOUND POWER CABLE FOR FLOOR LIGHT WET AND SHORTING. DRIED FLOOR.…
- 25 Nov 2001
Warning System, malfunctioned
AFTER TAKEOFF DURING GEAR RETRACTION NOSE GEAR FAILED TO RETRACT AND WAS ACCOMPANIED BY GEAR DISAGREE AND NOSE DOOR OPEN MESSAGES WITH GEAR INDICATION SHOWING…
- 23 Nov 2001
Socket, faulty
EMERGENCY LIGHTS ARE ON WITH THE SWITCH IN ARMED POSITION. REMOVED AND REPLACED EMERGENCY EXIT LIGHT REFLECTOR AND SOCKET ASSEMBLY AFT OF RT OVERWING…
- 25 Sep 2001
Bolt, corroded
RIGHT WING TRAILING EDGE NEAR AILERON POSITIONING TRANSMITTER HAS 3 CORRODED BOLTS. NEW HARDWARE INSTALLED IAW CRJ MM 27-15-01.
- 25 Sep 2001
Beam, cracked
ENGINE PYLON BOX BEAM LOWER WEB CRACKING FROM ANCHOR NUTS AT STRESS PANEL FS 640 LEFT AND RIGHT SIDES. REPAIRS ACCOMPLISHED IAW REO 601R-53-61-366, LEFT AND…
- 25 Sep 2001
Beam, cracked
ENGINE PYLON BOX BEAM UPPER WEB HAS 2 CRACKS AT LBL 8.0 AND RBL 7.5, RADIATING FWD FROM TRAILING EDGE OF BEAM. CARRY OUT REPAIRS TO LOWER BOX BEAM WEB IAW REO…
- 23 Sep 2001
Proximity Switch, out of adj
ON TAKEOFF, HAD A CARGO DOOR CAUTION MESSAGE. PERFORMED ADJUSTMENT/TEST OF CARGO DOOR PROX SWITCHES PER CRJ MM 52-70-02. OPS CHECK FOUND GOOD.
- 13 Jun 2001
Switch, failed
STAB TRIM CH NR 1 & 2 AND MACH TRIM ALL DISENGAGED SHORTLY AFTER TAKE OFF, RETURNED FOR LANDING. INSTALLED NEW STAB TRIM DISCONNECT SWITCH ON FIRST OFFICER'S…
- 30 May 2001
Warning System, activated
ON TAKEOFF ROLL ABOVE APPROXIMATELY 90 PERCENT N1, HAD A RED WARNING MESSAGE CONFIG AILERON AND CONFIG TRIM WITH AURAL WARNING. TRIM WAS IN THE GREEN. ABORTED…
- 5 May 2001
Windshield, cracked
LEFT WINDSHIELD CRACKED. REMOVED AND REPLACED LT SIDE WINDOW (WINDSHIELD) IAW CRJ MM 56-12-01. PRESSURIZED AIRCRAFT TO 3.0 PSI. OPS LEAK CHECK OF WINDOW…
- 12 Apr 2001
Control Unit, contaminated
STAB TRIM CHANNEL 2 WILL NOT ENGAGE. WITH STAB TRIM CHANNEL 1 ENGAGED, THE MACH TRIM WILL NOT ENGAGE. REMOVE AND REPLACE MOTOR CONTROL UNIT (MCU) HORIZONTAL…
- 7 Apr 2001
Adc, failed
ADC1 FAILURE, MAC TRIM FAILURE, IAS 1 FAIL, FD FAILURE - CAT II. REMOVED AND REPLACED NR 1 ADC 850A AND NR 1 ADC DRAIN ASSEMBLY. OPS CHECK GOOD IAW 34-13-01.…
- 15 Mar 2001
Reservoir, failed
AFTER TAKEOFF SELECTED GEAR UP AND HYDRAULIC NUMBER THREE LOW PRESSURE CAUTION CAME ON, FOLLOWED BY GEAR UP DISAGREE (BOTH MAIN GEAR). ALSO, NOSE DOOR OPEN…
- 20 Sep 2000
Actuator, failed
SETTING FLAPS FROM 0 DEGREES TO 8 DEGREES FLAPS FAILED AT 0 DEGREES WITH ATTENDING FLAP FAIL CAUTION MESSAGE. PERFORMED A ''''NO FLAP'''' LANDING. FOUND RIGHT…
- 2 Jul 2000
Drag Brace, damaged
NOSE GEAR WOULD NOT RETRACT AFTER TAKEOFF. RETURNED TO FIELD. REMOVED AND REPLACED NOSE LANDING GEAR DRAG BRACE IAW MM 322105. OPS AND LEAK CHECKS GOOD. P/N…
- 26 Nov 1999
Sensor, malfunctioned
PITOT BASE OVERHEAT WARNING ILLUMINATED AFTER TAKEOFF. RETURNED TO FIELD. POWERED AIRCRAFT DOWN AND BACK UP. NO DEFECTS NOTED AT THIS TIME. AIRCRAFT GOOD FOR…
- 1 Jun 1999
Overheat Message, malfunction
RIGHT 14TH STAGE DUCT OVERHEAT MESSAGE EN ROUTE. QUICK REFERENCE HANDBOOK PERFORMED AND MESSAGE PERSISTS. SINGLE ENGINE PROCEDURE PERFORMED AND DUCT MESSAGE…
- 24 Feb 1998
Fecu, failed
FLAP FAIL MSESSAGE DURING FLAP RETRACTION ON CLIMB-OUT. RETURNED FOR LANDING. REMOVED FLAP PDU AND FECU AND REPLACED WITH SERVICEABLE UNITS IAW MM 27-52-01.…
- 22 Feb 1998
Adc, failed
ON APPROACH TO EUG PFD NR 1 LOST ALL AIR DATA (AIRSPEED, ALTITUDE, ATTITUDE, VSI) ALSO MACH TRIM. REMOVED AND REPLACED IDC 4000 CONVERTER. ALL SYSTEMS CHECKS…
- 7 Oct 1997
Fire Loop, malfunctioned
LEFT JET PIPE LOOP A FAILED. MEL 26-11-2, INSPECTED LEFT EXHAUST NOZZLE FAIRING FOUND LOOSE HARDWARE. REMOVED AND INSTALLED SERVICEABLE HARDWARE AND SECURED…
- 9 Aug 1997
Web, torn
ON CLIMBOUT, HEARD A VERY LOUD LOW FREQUENCY VIBRATION. OCCURRED 2 TIMES AND SUBSIDED BOTH TIMES WITHOUT ANY CHANGES BY CREW TO CONFIGURATION. RETURNED TO TUC…
- 8 Jul 1997
Ahrs, malfunctioned
AFTER TAKEOFF ATTITUDE AND HEADING BECAME INOP, YAW DAMPER 1 BECAME INOP AND AUTO PILOT INOP. RETURNED TO SLC. REPLACED CAPTAINS AHRS COMPUTER. OPS CHECKS…
- 3 Jun 1997
Angle, corroded
FLOOR SUPPORT ANGLE IN PASSENGER DOOR OPENING HAS CORROSION. REMOVED LOWER FLOOR BOARD SUPPORT ANGLE IN ENTRANCE WAY OF CABIN DOOR AND FABRICATED NEW ANGLE…
- 3 May 1997
Downlock Pin, dirty
AIRCRAFT FERRIED TO PSP DUE TO NOSE LANDING GEAR NOT COMING UP AT SFO. RETURNED TO FIELD FOR LANDING. JACKED AIRCRAFT UP AND FOUND DIRT IN GEAR DOWNLOCK PIN.…
- 22 May 1996
Drag Brace, failed
TAKEOFF BUR, NOSE GEAR WOULD NOT RETRACT. NOSE GEAR REMAINED DOWN WITH NO TRANSIT INDICATION. CYCLED FOUR TIMES TO GET NOSE GEAR UP. REPLACED NOSE GEAR DRAG…
- 22 Apr 1996
Priority Valve, malfunctioned
AFTER DEPARTURE, NOSE GEAR FAILED TO RETRACT. PERFORMED QRH CHECKLIST. RETURNED TO PDX WITH A NORMAL LANDING. REMOVED AND REPLACED MAIN LANDING GEAR PRIORITY…
- 18 Apr 1996
Retract Mech, malfunctioned
NOSE GEAR DID NOT RETRACT AFTER TAKEOFF. ATTEMPTED QRH PROCEDURES WITH NO CHANGE. RECEIVED GEAR DISAGREE AND NOSE DOOR OPEN MESSAGE A FEW SECONDS LATER.…
- 22 Oct 1995
Fail Message, activated
FLAP FAIL MESSAGE AFTER TAKEOFF. ALSO, FLAP OVERSPEED AURAL WARNING AT 230 KTS. REVIEWED FLAP FAULTS AT FECU AND RESET FECU. OP CK FLAPS, OP CK GOOD.
- 15 Jul 1995
Fecu, malfunctioned
FLAP FAIL MESSAGE AT FLAP RETRACTION AFTER TAKEOFF, FLAPS INOP, COMPLETED FLAPS UP LANDING. RESET FECU ON FLAP CON CHAN 1 AND CHAN 2, OPS CKS NORMAL.
- 14 Jul 1995
Contl Mech, malfunctioned
FLAPS FAIL MESSAGE, FLAP FAILED AT 18 DEGREES. CONTACTED SGU MAIN CONTROL. DIVERTED TO MSO. RESET FECU CIRCUIT BREAKER FLAPS FAIL MESSAGE, CLEANED FLAPS, OPS…