33 reports
- 2 Sep 2025
Engine, failed
ENGINE 2 FAIL AND LOUD BANG ON TAKEOFF AROUND 1500 FEET. WINDMILLING AND NO OIL PRESSURE, SLIGHT ODOR IN CABIN. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT.…
- 3 Nov 2024
Floorbeam, corroded
DURING HEAVY CHECK MAINTENANCE FOUND AFT CABIN FLOOR STRUCTURE CROSSBEAM AT FR 84 CENTER HAS A TOOLING SCRATCH ON THE UPPER SURFACE. COMPLIED WITH…
- 18 Mar 2024
Power Supply, inoperative
L1 EMERGENCY LIGHT POWER UNIT INOP. R&R L1 EMERGENCY LIGHT POWER UNIT.
- 31 Aug 2022
Stringer, corroded
WHILE IN HEAVY CHECK - STGR 19L INTERNAL SIDE HAS CORROSION AS MARKED FR 83-84. PERFORMED STRINGER SPLICE REPAIR ON STRINGER 19L BETWEEN FR 82/83 TO FR 86/87.…
- 31 Aug 2022
Stringer, corroded
WHILE IN HEAVY CHECK - STGR 19R INTERNAL SIDE HAS CORROSION AS MARKED FR 83-84. REMOVED DAMAGED SECTION OF STRINGER 19R FR 83/84. INSTALLED. REPAIR FILLER…
- 31 Aug 2022
Stringer, corroded
WHILE IN HEAVY CHECK - STGR 20R INTERNAL SIDE HAS CORROSION AS MARKED FR 83-84. REMOVED AND REPLACED STRINGER 20R FROM FRAME 80 TO FRAME 89 REF SRM 51-40-02.
- 31 Aug 2022
Stringer, corroded
WHILE IN HEAVY CHECK - STGR 21R INTERNAL SIDE HAS CORROSION AS MARKED FR 83-84. REMOVED DAMAGED SECTION STGR 21R FR81/86 AND REPAIRED WITH FILLER SECTION AND…
- 2 May 2022
Panel, dented
MULTI DENTS FOUND BELOW CAPTS DV WINDOW. REPAIRED IAW ETD2022-170-016305.
- 1 Apr 2022
Strip, inoperative
AIRCRAFT LEFT AISLE ILLUMINATION STRIPS DON'T WORK EVEN WHEN CHARGED VIA BRIGHT CABIN LIGHT. R&R PHOTOLUMINESCENT STRIPS ON LEFT AISLE NEAR FIRST CLASS AND RH…
- 13 Jul 2021
Strip, inoperative
FLOOR STRIP LUMINESCENT STRIPS ARE INOP ON LEFT SIDE NEXT TO SEAT 21-22. RESECURED FLOOR G2 PHOTOLUMINESCENT STRIPS AT 21-22 IAW AMM 33-50-21.
- 9 Feb 2020
Seat Track, corroded
WHILE IN HEAVY CHECK- CORROSION ALONG TOP SIDE OF L/H I/B SEAT TRACK BETWEEN FR. 16 TO FR. 20 AS MARKED.REPLACE SEAT TRACK WITH NEW AND APPLY SURFACE…
- 9 Feb 2020
Spar, damaged
WHILE IN HEAVY CHECK - UPON SKIN OPEN UP ON LH HORIZONTAL, FOUND DIMPLED AREA BESIDE FASTENER HOLE ON SPAR I BETWEEN RIB 9A-10A. PERFORMED PERMANENT REPAIR BY…
- 15 Aug 2019
Power Supply, faulted
EMERGENCY LIGHTS NUMBER 1 AND 3 NOT ILLUMINATING. R&R FWD LH EMERGENCY LIGHTS POWER UNIT IAW AMM 33-50-01.
- 23 Jun 2018
Light, missing
EMERGENCY EXIT PATHWAY PHOTOLUMINESCENT STRIP MISSING AT SEAT 20D. R&R STRIP LIGHT AT SEAT 20D IAW AMM 33-50-21.
- 15 Mar 2018
Warning Message, false activation
DURING CRUISE, CAS MESSAGE FOR SLAT FAIL. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. CLEARED INHIBITS AND OPERATED FLAP/SLATS IAW AMM 27-80-00. OPS CHECKED…
- 25 Feb 2018
Seal Rest, corroded
CORROSION WAS FOUND AT THE FORWARD CARGO DOOR CUTOUT LOWER FWD CORNER SEAL REST. MAINTENANCE REMOVED AND REPLACED FWD CARGO DOOR CUTOUT LOWER FWD CORNER SEAL…
- 20 Feb 2018
Seal Rest, corroded
CORROSION WAS FOUND AT THE FORWARD CARGO DOOR CUTOUT LOWER CENTER SEAL REST. MAINTENANCE REMOVED AND REPLACED FWD LOWER CENTER SEAL REST IAW SRM 51-41-01.
- 20 Feb 2018
Seal Rest, corroded
CORROSION WAS FOUND AT THE FORWARD CARGO DOOR CUTOUT LOWER AFT CORNER SEAL REST. MAINTENANCE REMOVED AND REPLACED CARGO DOOR CUTOUT LOWER AFT CORNER SEAL REST…
- 19 Feb 2018
Cover Plate, corroded
CORROSION WAS FOUND AT THE FORWARD CARGO DOOR CUTOUT COVER PLATE. MAINTENANCE REMOVED AND REPLACED FWD CUTOUT PLATE IAW SRM 20-10-01.
- 15 Feb 2018
Flap Track, corroded
RIGHT OTBD FLAP, INBD CARRIAGE UPPER TRACK COATING IS COMING OFF AND HAS CORROSION. MAINTENANCE REMOVED AND REPLACED THE FLAP TRACK IAW AMM 57-57-33.
- 15 Feb 2018
Shear Panel, corroded
WHILE THE ACFT WAS OUT OF SERVICE, MAINTENANCE DISCOVERED THE AFT WET AREA CENTER SHEAR PANEL, FRAMES 87 - 88 CORRODED AROUND THE LAVATORY AND GALLEY MOUNT…
- 15 Feb 2018
Shear Panel, corroded
WHILE OUT OF SERVICE, MAINTENANCE DISCOVERED THE AFT WET AREA SHEAR PANEL AT FRAMES 87 - 88 HAS CORROSION AROUND GALLEY MOUNT HOLES. MAINTENANCE REMOVED AND…
- 15 Feb 2018
Gusset, corroded
WHILE OUT OF SERVICE, MAINTENANCE DISCOVERED AFT WET AREA GUSSET AT FRAME 90, RBL 12 IS CORRODED. MAINTENANCE REMOVED AND REPLACED THE GUSSET IAW SRM 51-41-02.
- 13 Feb 2018
Skin, dented
MAINTENANCE FOUND A DENT IN THE RT FUSELAGE SKIN BETWEEN FRAMES 7 & 8, STRINGERS 15 & 16R FWD OF LOGO LIGHT BELOW FIRST OFFICER WINDOW. REPAIRED IAW…
- 5 Jul 2017
Diaphragm, leaking
FWD PAX DOOR PNEUMATIC ASSEMBLY AT 0 PSI. R & R PAX ENTRY DOOR PNEUMATIC ASSEMBLY DIAPHRAGM IAW AMM 52-11-53. SERVICED TO 2200 PSI IAW AMM 52-11-51.
- 25 Nov 2016
Glowstrip, worn
CREW REPORTED THAT THE PHOTO LUMINESCENT STRIPS IN THE FORWARD CABIN WERE WORN AND NO LONGER GLOW. MAINTENANCE REMOVED AND REPLACED PHOTO LUMINESCENT STRIPS…
- 17 Sep 2016
Battery Pack, discharged
CREW REPORTED THAT THE 4TH CABIN EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE R & R EMERGENCY BATTERY PACK NR 4 IAW AMM AND OPS CHECKED GOOD.
- 3 Jul 2015
Glowstrip, loose
CREW REPORTED THAT THE PHOTOLUMINESCENT STRIP NEAR THE CLOSET WAS PEELING. MAINTENANCE RESECURED PHOTOLUMINESCENT STRIP IAW AMM AND OPS CHECKED GOOD.
- 4 Oct 2014
Flashlight, inoperative
CREW REPORTED THAT THE CAPTAIN`S FLASHLIGHT WAS INOPERATIVE. MAINTENANCE R & R CAPTAIN`S FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.
- 6 Apr 2014
Unknown, odor
F/A REPORTED AN ELECTRICAL ODOR COMING FROM THE AFT GALLEY WITH NO SMOKE OR FIRE VISIBLE. SHUTOFF COFFEEMAKERS WITH NO EFFECT. DECLARED AN EMERGENCY AND…
- 26 Mar 2014
Flashlight, inoperative
CREW REPORTED THAT THE CAPTAINS FLASHLIGHT WAS INOPERATIVE. MAINTENANCE OPS CHECKED FLASHLIGHT GOOD IAW AMM.
- 16 Dec 2013
Flashlight, inoperative
DURING PREFLIGHT CHECK THE AFT F/A FLASHLIGHT WAS FOUND TO BE INOPERATIVE. THE FLASHLIGHT WAS R & R IAW AMM 33-51-01.
- 22 Oct 2013
Indicator, out of adjust
CREW REPORTED THAT THE L2 DOOR ARM/DISARM INDICATOR WAS NOT FULLY INDICATING. MAINTENANCE INSPECTED AND FOUND ARM/DISARM INDICATOR FULLY FUNCTIONAL, BUT THE…