N407AT
2024 Bell Textron Canada Ltd 407 standard FAA →
registration
- 2024
earlier registrations
1 past record
- 1994
NTSB
- 28 Apr 2007
accident, San Juan PR
service difficulty reports
69 reports
- 17 May 2012
Panel, out of adjust
THE F/A REPORTED THE EMERGENCY EQUIPMENT PANEL AT JUMP SEAT NR 2 IS BROKEN. THE ACFT WAS REMOVED FROM SERVICE. REPOSITIONED F/A NR 2 EMERGENCY EQUIPMENT PANEL…
- 24 Apr 2012
Bulb, inoperative
THE CREW REPORTED THE PASENGER ENTRY DOOR EMERGENCY LIGHT WAS INOPERATIVE. ACFT REMOVED FROM SERVICE. R & R BULB IAW MM 33-51-25. OPS TEST SATISFACTORY IAW…
- 20 Apr 2012
Bulb, inoperative
CREW REPORTED THE FWD EMERGENCY EXIT FLOOD LIGHT INOPERATIVE. ACFT REMOVED FROM SERVICE. R & R EMERGENCY EXIT FLOOD LIGHT BULB IAW MM 33-51-24. THE OPS…
- 9 Apr 2012
Light, inoperative
FLIGHT 4843, CREW REPORTED THE OUTSIDE EMERGENCY LIGHT ON WINDOW INOPERATIVE. ACFT REMOVED FROM SERVICE. RESET THE FORWARD EMERGENCY LIGHT (EXTERIOR) IAW JIC…
- 13 Mar 2012
Fuse, inoperative
THE CREW REPORTED THE MAIN ENTRANCE EMERGENCY LIGHT WAS INOPERATIVE. THE ACFT WAS REMOVED FROM SERVICE. R & R FUSE AT FIN NR 73 WL IAW MM 33-51-24. THE OPS…
- 8 Mar 2012
Structure, corroded
DURING MX INSP FOUND LT WING FUEL ELECTRIC PUMP SURROUNDING AREA WITH CORROSION. LT WING LT MAGNETIC FUEL LEVEL SURROUNDING AREA WITH CORROSION. LT WING RIB 6…
- 29 Feb 2012
Feeder Cable, broken
DURING B INSPECTION, FOUND EMERGENCY FLOOR PATH LIGHT AT SEAT 7B INTERMITTENT. THE ACFT WAS REMOVED FROM SERVICE. REPAIRED BROKEN CABLE ON EMERGENCY FLOOR…
- 19 Feb 2012
Contactor, damaged
DURING MX BASE VISIT, FOUND THAT THE CONTACTOR FOR EMERGENCY BATTERY NEEDS TO BE REPLACED. THE ACFT WAS REMOVED FROM SERVICE. INSTALLED 42PA EMERGENCY BATTERY…
- 7 Feb 2012
Bulb, loose
THE CREW REPORTED THE CABIN ENTRANCE DOOR EMERGENCY FLOOD LIGHT INOPERATIVE (STAIR). ACFT WAS REMOVED FROM SERVICE. CABIN ENTRANCE DOOR EMERGENCY LIGHT BULB…
- 22 Jan 2012
Magnet, failed
THE CREW REPORTED THE EMERGENCY GEAR HANDLE DOOR WOULD NOT STAY CLOSED. ACFT REMOVED FROM SERVICE. REPLACED EMERGENCY EXTENSION HANDLE COVER MAGNET IAW EO…
- 17 Jan 2012
Switch, inoperative
THE CREW REPORTED BOTH TAXI LIGHT INOPERATIVE BUT LANDING LIGHTS WORK PROPERLY. THE ACFT WAS REMOVED FROM SERVICE. R & R SWITCH 1LR IAW MM 20-45-10, OPS CHECK…
- 26 Dec 2011
Fan, failed
NR 1 RECIRCULATING FAN FAULT. STRONG BURNING ODOR COMING FROM DUCT ASSOCIATED WITH SOME SMOKE. NR 1 RECIRCULATING FAN REPLACED IAW MM 21-22-21. SYS. OPERATED…
- 5 Oct 2011
Battery Pack, inoperative
CABIN DOOR EMERGENCY EXT LIGHT INOPERATIVE. R & R POWER SUPPLY 62WL AND BATTERY PACK IAW JIC 33-51-21. OPS OK.
- 13 Sep 2011
Wire, damaged
EMERGENCY LIGHT ON MAIN ENTRANCE IS INOPERATIVE. REPAIRED EMERGENCY LIGHT 21WL GROUND WIRE 19VN IAW MM 20-27-17 AND 33-51-11. OPS TESTED SATISFACTORY IAW JIC…
- 3 Sep 2011
Light, inoperative
EMERGENCY FLOOD LIGHT BY LT FORWARD EMERGENCY EXIT INOP. PERFORMED OPS CHECKED TO EMERGENCY FLOOD LIGHTS AND FOUND OK IAW EX-335000-OPT-10000-001.
- 25 Aug 2011
Engine, surges
NR 1 ENGINE DURING CRUSE, SURGED ABOUT 30 PERCENT TO 40 PERCENT ALSO ITT SURGE ABOUT 30 TO 60 PERCENT. POWER WAS ABOUT 40 TORQUE. R & R HMU ON ENG NR 1 IAW…
- 30 Jun 2011
Brake Sys, malfunctioned
THE CREW REPORTED THAT UPON LANDING THE CAPTAIN’S TOE BRAKE WAS NON RESPONSIVE WHEN DEPRESSED. THE ACFT WAS REMOVED FROM SERVICE. PERFORMED BRAKE LOW PRESSURE…
- 11 Oct 2010
Brake, worn
BRAKES ARE SPONGY. PEDALS CAN BE PRESSED ALL THE WAY TO THE STOPS. R & R NR 2 AND 4 BRAKE ASSY IAW JIC 32-42-55-RAI-10000-005.
- 2 Sep 2010
Bulb, burned out
EMERGENCY EXIT LIGHT AT BOTTOM OF STAIRS IS INOP. REPLACED BULB AT EMER EXIT LIGHT AT BOTTOM OF STAIR IAW MM CHPT 33-50-00.
- 29 Jun 2010
Skin, corroded
LT WING LOWER SKIN CORROSION BLEND-OUT REPAIR AT FUEL DRAIN, OPEN
- 29 Jun 2010
Skin, corroded
C/W LT WING LOWER SKIN CORROSION BLENDED OUT PERMENANT REPAIR AT FUEL DRAIN BTW RIBS 4-5 IAW EO E2-57MR-400. NDT REPORT ACCOMPLISHED IN REF TO AMS 100603-42.…
- 29 Jun 2010
Skin, damaged
LT WING LOWER SKIN BLEND-OUT REPAIR AT FUEL PUMP CUTOUT PERMANENT REPAIR. WAITING FOR COMPLETION OF E0 E2-57MR-401 FOR FURTHER DETAILS. A PERMENANNT REPAIR…
- 29 Jun 2010
Skin, corroded
LEFT WING LOWER SKIN PANEL, REAR SPAR BTW RIBS 7-8 FINAL CORROSION BLEND-OUT REPAIR. WAITING FOR COMPLETION OF EO E2-57MR-319R3 FOR FURTHER DETAILS. C/W SRAS…
- 29 Jun 2010
Skin, corroded
LT WING LOWER SKIN CORROSION BLEND-OUT PERMANENT REPAIR AT JACK POINT RIB 10. WAITING FOR COMPLETION OF EO E2-57MR-378R1 FOR FURTHER DETAILS. PERMANENT REPAIR…
- 28 Jun 2010
Spar, corroded
LT WING LOWER SKIN REAR SPAR AT RIB 11 CORROSION TITANIUM DOUBLER PERMANENT REPAIR. COMPLIED WITH TDMI 570383 LT WING AFT SPAR LOWER CHORD AT RIB 11. NDT…
- 14 Jun 2010
Pressure Blkhd, corroded
CORROSION WAS FOUND ON THE FWD PRESSURE IN ONE AREA OF THE BULKHEAD WEB. REPAIRED FWD BULKHEAD AERA IAW AM/EO NR E2-53MR-255. ATR SRI DO/TS-3032/10-13623 ATR…
- 12 Apr 2010
Structure, corroded
CORROSION FOUND ON LT WING FUEL PUMP SURROUNDING AREA. COMPLIED WITH LT WING, LOWER SKIN CORROSION BLEND OUT TEMPORARY REPAIR AT FUEL PUMP CUT-OUT AREA IAW EO…
- 12 Apr 2010
Skin, corroded
CORROSION FOUND ON LT WING FUEL DRAIN (INNER) SURROUNDING AREA. COMPLIED WITH LT WING, LOWER SKIN CORROSION BLEND OUT TEMPORARY REPAIR AT FUEL DRAIN BTW RIBS…
- 12 Apr 2010
Skin, corroded
CORROSION FOUND ON LT WING JACKING POINT AREA. COMPLIED WITH LT WING, LOWER SKIN CORROSION BLEND OUT TEMPORARY REPAIR AT JACK POINT AT RIB 10 AREA IAW EO…
- 14 Nov 2009
Fan, smoke
UPON ARRIVAL SMOKE IN THE CABIN DETECTED. AT THIS TIME ENTERED RT RECIRCULATING FAN ON MEL NR 21-3 AUTH NR 11105-C.
- 14 Nov 2009
Fan, damaged
UPON ARRIVAL SMOKE IN THE CABIN DETECTED. AT THIS TIME ENTERED RT RECIRCULATING FAN ON MEL NR 21-3 AUTH NR 11105-C. REPLACED RT RECIRCULATING FAN IAW JIC NR…
- 12 Feb 2009
Unknown, unknown
CAPT SIDE ONLY LOST HIS BRAKES DURING TAXI AND THE F/O BRAKES WERE OPERATING NORMAL. THE ACW IS OPERATIONAL. GREEN HYDRAULIC SYSTEM IS OPERATIONAL. PERFORMED…
- 22 Dec 2008
Wire Harness, open
THE ELECTRICAL CIRCUIT TO THE TORQUE PROBE NR 2 FROM THE EEC, USING A PORTATIVE OHM METER, WAS VERIFIED. THE CIRCUIT TORQUE NR 1 AND THE TORQUE SENSOR TEMP…
- 18 Apr 2008
Engine, malfunctioned
AFTER TAKEOFF LEVEL AT 6000 FT, NR 2 ENG INTERMITTENT OVERTORQUE. SHUT DOWN THE ENGINE AS PER AOM VOL 2. PERFORMED SEVERAL ENGINE RUNS (RT) AT ALL POWER…
- 18 Apr 2008
Engine, malfunctioned
AFTER TAKEOFF LEVEL AT 6000 FT, NR 2 ENG INTERMITTENT OVERTORQUE. SHUT DOWN THE ENGINE AS PER AOM VOL 2. EMERGENCY WAS DECLARED AND RETURNED TO SLU. PERFORMED…
- 15 Jan 2008
Shock Absorber, damaged
VERY STRONG NOISE IN NOSE GEAR DURING RETRACTION. REMOVED AND REPLACED THE NOSE LANDING GEAR SHOCK ABSORBER IAW MM NR 32-21-00. REMOVED AND REPLACED LT NOSE…
- 24 Sep 2007
Lamp, burned out
EMERGENCY EXIT LIGHT AT BASE OF MAIN CABIN DOOR IS BURNED OUT, EXTERNAL FLOOD LIGHT. REPLACED BULB ON MAIN CABIN DOOR EMERGENCY LIGHT ASSY. PERFORMED…
- 13 Jul 2007
Unknown, odor
BOTH F/A REPORTED SMELLING ELECTRIC BURN AT PAX SEAT 15B WHILE SERVICING. NO ODOR AFTER READING AND LATERAL LIGHTS WERE TURNED OFF. WITH DC AND AC POWER ON…
- 15 May 2007
Battery Pack, failed
EMERGENCY PAX DOOR STAIR LIGHT INOPERATIVE. REPLACED BATTERY PACK AS PER JIC NR 33-51-21. OPERATIONAL CHECK GOOD.
- 6 Feb 2006
Valve, defective
DURING TAKEOFF, FLAPS EXTENSION FLAG WARNING WAS ON AND OFF. VISUALLY CONFIRMED FLAPS MOVING. FLAPS SELECTED TO 0 POSITION AND RETURNED TO AIRPORT WITH A…
- 29 Feb 2004
Control Unit, intermittent
LT ENGINE FIRE WARNING INTERMITTENT. REPLACED FIRE CONTROL UNIT.
- 15 Jun 2002
Control Cable, damaged
AFTER FAILURE OF A FUNCTIONAL CHECK FLIGHT DUE TO EXCESSIVE USAGE OF AILERON TRIM TO MAINTAIN A STRAIGHT AND LEVEL FLIGHT, THE AIRCRAFT WAS INSPECTED AND…
- 8 Oct 1998
Bulb, failed
MIA - FLT 5700 - FOUND EMERGENCY LIGHT AT PAX DOOR STATION DOES NOT ILLUMINATE. REMOVED AND REPLACED BULB. OPERATIONAL CHECK GOOD. (M)
- 22 Jun 1998
Support, corroded
SAW - DURING CPCP8 INSPECTION, FOUND FLOOR SUPPORT CHANNEL BETWEEN FRAMES 38 AND 39, UNDER PASSENGER DOOR SILL PLATE, CORRODED. INSTALLED NEW FLOOR CHANNEL…
- 22 Jun 1998
Seat Track, corroded
SAW - DURING CPCP8 INSPECTION, FOUND LEFT AFT INBOARD SEAT TRACK CORRODED FROM FRAME 29 TO FRAME 36. REMOVED AND INSTALLED NEW SEAT TRACK BETWEEN FRAME 29 AND…
- 22 Jun 1998
Floorbeam, corroded
SAW - DURING CPCP8 INSPECTION, FOUND FLOORBEAM 36 CORRODED. REMOVED AND REPLACED FLOORBEAM 36. (X)
- 22 Jun 1998
Seat Track, corroded
SAW - DURING CPCP8 INSPECTION, FOUND LEFT AFT OUTBOARD SEAT TRACK CORRODED BETWEEN FRAME 29 AND FRAME 36. REMOVED AND INSTALLED NEW LEFT AFT OUTBOARD SEAT…
- 22 Jun 1998
Sill, corroded
SAW - DURING CPCP8 INSPECTION, FOUND SERVICE DOOR SILL PLATE CORRODED. REMOVED AND INSTALLED NEW SERVICE DOOR SILL PLATE. (X)
- 22 Jun 1998
Seat Track, corroded
SAW - DURING CPCP8 INSPECTION, FOUND LEFT FLIGHT ATTENDANT'S SEAT TRACK TO HAVE CORROSION BETWEEN FLOORBEAM 36 AND FLOORBEAM 39. REMOVED AND REPLACED LEFT…
- 22 Jun 1998
Sill, corroded
SAW - DURING CPCP8 INSPECTION, FOUND PASSENGER DOOR SILL PLATE TO HAVE CORROSION. REMOVED AND REPLACED PASSENGER DOOR SILL PLATE. (X)
- 22 Jun 1998
Gulley, corroded
SAW - DURING CPCP8 INSPECTION, FOUND RAIN GULLEY ON PASSENGER DOOR SILL PLATE TO HAVE CORROSION. REMOVED AND REPLACED RAIN GULLEY ON PASSENGER DOOR SILL…
- 28 Apr 1998
Bulb, failed
DFW - FLT 4151 - FLOOR PROXIMITY LIGHT AT ROW 6 INOP. ISSUED MEL 33-22 AND RETURNED A/C TO SERVICE. R/I'D BULB. PERFORMED OPERATIONAL CHECKS SATISFACTORILY…
- 27 Mar 1998
R/T Unit, failed
CRP - FLT 3716 - DURING FLT TO DFW FROM HRL CREW NOTED SMOKE IN FLIGHT CABIN. CREW DIVERTED INTO CRP. CFR FOLLOW A/C TO GATE. A/C LANDED SAFELY. NOTE SMOKE…
- 10 Feb 1998
Probe, failed
ORD - FLT 4123 - FLT CREW REPORTED SMOKE SMELL IN THE CABIN AND COCKPIT. MAINTENANCE R/I'D P2.5/P3 SWITCHING VALVE AND NL PROBE IAW PWA MM 72-01-60. PERFORMED…
- 10 Feb 1998
Valve, failed
ORD - FLT 4123 - FLT CREW REPORTED SMOKE SMELL IN THE CABIN AND COCKPIT. MAINTENANCE R/I'D P2.5/P3 SWITCHING VALVE AND NL PROBE IAW PWA MM 72-01-60. PERFORMED…
- 29 Dec 1997
Fuse, failed
ORD - FLT 4127 - FLT ATTENDANT REPORTED THAT 8 FLOOR PROXIMITY LIGHTS NOT WORKING. ISSUED MGL 33-20 AND RETURNED A/C TO SERVICE. FOUND FUSE BLOWN IN 61WL…
- 3 Nov 1997
Battery Pack, discharged
ORD - FLT 4350 - SOME EMERGENCY LIGHTS INOP. REPLACED POWER SUPPLY AND BATTERY PACK 61WL. OPS CHECK GOOD. AIRCRAFT WAS RETURNED TO SERVICE. (M)
- 13 Oct 1997
Power Supply, inoperative
DFW - FLT 3536 - EMERGENCY FLOOR PROXIMITY ESCAPE PATH MARKINGS HAVE 8 BULBS OUT EVERY OTHER ONE. TWO OF THE OVERHEAD LIGHTS ARE ALSO OUT. REPLACED POWER…
- 2 Oct 1997
Idler Arm, defective
DURING COMPLIANCE OF ENGINEERING ORDER E9-2700-001R3 (AD93-22-10) MAINTENANCE FOUND IDLER ARM IN THE RIGHT WING AT THE SPOILER VALVE BLOCK WITH LOOSE…
- 31 May 1997
Bulb, failed
MKE - EMERGENCY LIGHT ROW 6 INOP MEL 33-22. REPLACED BULB, OPS CHECK GOOD. AIRCRAFT WAS RETURNED TO SERVICE. (M)
- 16 May 1997
Light, broken
ORD - FLT 4382 - LAST FLOOR PROX LIGHT LENS BROKEN. INSPECTED AND RETURNED AIRCRAFT TO SERVICE PER SIMMONS MEL 33-22. RAI'D TRACK LIGHT ASSEMBLY. PERFORMED…
- 16 May 1997
Valve, failed
ORD - FLT 4029 - ELECTRICAL/SMOKE SMELL ENTERED CABIN FOLLOWING THE STARTING OF ENGINES. MAINTENANCE WAS ABLE TO DUPLICATE SMELL PRIOR TO REMOVING. CLEANED…
- 7 Apr 1997
Smoke Detector, malfunctioned
IND - FLT 4188 - FORWARD SMOKE DETECTOR WARNING LIGHT ILLUMINATED IN FLIGHT, CREW INSPECTED THE CARGO COMPARTMENT AND NO SMOKE OR FIRE WAS NOTED. FLIGHT…
- 24 Jan 1997
Battery Pack, discharged
GRR - EMERGENCY LIGHT ON AIRSTAIRS INOP. CHANGED POWER SUPPLY AND BATTERY PACK IAW ATR 72-516. OPS CHECK GOOD. AIRCRAFT WAS RETURNED TO SERVICE. (M)
- 24 Jan 1997
Power Supply, inoperative
GRR - EMERGENCY LIGHT ON AIRSTAIRS INOP. CHANGED POWER SUPPLY AND BATTERY PACK IAW ATR 72-516. OPS CHECK GOOD. AIRCRAFT WAS RETURNED TO SERVICE. (M)
- 14 Jan 1997
Battery Pack, discharged
ORD - FLT 4317 - AFT EMERGENCY LIGHTS STAY ON. REMOVED AND REPLACED AFT BATTERY PACK/POWER SUPPLY IAW JIC33-21-21. PERFORMED SATISFACTORY OPERATIONAL CHECK.…
- 27 Feb 1996
O-Ring, failed
DFW - FLT 3811 - DURING TAXI OUT, GREEN SYSTEM HYD LOW LEVEL ALARM ILLUMINATED. NORMAL BRAKING CONTROL WAS LOST. AIRCRAFT RETURNED TO THE GATE. MAINTENANCE…
- 15 Jan 1996
Battery Pack, discharged
DFW - FLT NR 3749 - EMERGENCY LIGHTS ON AIRSTAIRS WON'T SHUT OFF AFTER BEING TESTED. RAI'D EMERGENCY BATTERY PACK, OPS CHECKED GOOD, RETURNED AIRCRAFT TO…
- 16 Sep 1995
Idler Arm, loose
DFW - DURING COMPLIANCE OF EO E9-2700-001 (REPETITIVE INSPECTION AILERON CONTROL SYSTEM) AD 93-22-10, MAINTENANCE FOUND THE NR 2 IDLER ARM IN THE LEFT WING…