N406YX
2013 Embraer S A ERJ 170-200 LR standard FAA →
registration
- 2013
service difficulty reports
33 reports
- 16 Oct 2024
Stringer, corroded
CENTER FUSELAGE III STRINGER 20R CORRODED BETWEEN FRAMES 85-86. PERFORMED A SPLICE REPAIR IAW ETD2024-170-028307 AND SRM 53-22-03.
- 16 Oct 2024
Stringer, corroded
WHILE IN HEAVY CHECK - CENTER FUSELAGE III STRINGER 20R CORRODED BETWEEN FRAMES 85-86. PERFORMED STRINGER SPLICE REPAIR ON CENTER FUSELAGE III STGR 20R…
- 26 Apr 2021
Bellcrank, out of limits
ENGINE 1 CONTROL FAULT DURING DESCENT. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R&R E1 VG ACTUATOR BELL CRANK IAW ESM 72-00-00 SP016.
- 11 Feb 2020
Battery, inoperative
FWD 3 EMERGENCY LIGHTS FLICKER. TROUBLESHOT SYSTEM AND R&R FWD CEILING EMERGENCY LIGHTS BATTERY PACK IAW AMM 33-50-01.
- 4 Jan 2020
Seat Track, corroded
WHILE IN HEAVY CHECK FOUND CORROSION ON RH CENTER SEAT TRACK FRAME 84. CUT OUT CORRODED SEAT TRACK AT FRAME 84 AND PERFORMED REPAIR SPLICE REF EMB…
- 8 Nov 2019
Power Supply, inoperative
EXIT SIGN ABOVE COCKPIT DOOR DOES NOT ILLUMINATE WHEN EMERGENCY LIGHTS TESTED. R&R EMERGENCY LIGHT POWER UNIT IAW AMM 33-50-01. OPS CHECK OK.
- 15 Feb 2018
Web, corroded
MAINTENANCE DISCOVERED MULTIPLE AREAS OF CORROSION AT FWD WET AREA RT FLOOR WEB. FRAMES 12 - 14. REMOVED AND REPLACED THE FWD SILL PLATE IAW SRM 51-43-03, AND…
- 22 Jan 2018
Skin, corroded
CORROSION BETWEEN FRAMES 24 AND 25. AT EDGE OF FORWARD CARGO DOOR CUTOUT. BLENDED AND RESTORED FINISH IAW ETD2018-170-009072.
- 20 Jan 2018
Finger Doubler, corroded
AFT CARGO DOOR CUTOUT FORWARD FINGER DOUBLER HAS BUBBLED PAINT WITH CORROSION BETWEEN FRAMES 77 AND 78. REMOVED AND REPLACED THE FINGER DOUBLER IAW SRM…
- 20 Jan 2018
Finger Doubler, corroded
FWD CARGO DOOR CUTOUT BETWEEN FRAMES 24 AND 25 FWD FINGER DOUBLER IS CORRODED. REMOVED AND REPLACED THE FINGER DOUBLER IAW SRM 51-40-08, AND 51-40-02.
- 20 Jan 2018
Finger Doubler, corroded
FWD CARGO DOOR CUTOUT BETWEEN FRAMES 26 AND 27 AFT FINGER DOUBLER IS CORRODED. REMOVED AND REPLACED THE FINGER DOUBLER IAW SRM 51-40-08, AND 51-40-02.
- 20 Jan 2018
Seal Rest, corroded
FORWARD CARGO DOOR CUTOUT CENTER SEAL REST CORRODED. REMOVED AND REPLACED FORWARD CARGO CUTOUT CENTER SEAL REST IAW SRM 51-40-08.
- 20 Jan 2018
Seal Rest, corroded
FORWARD CARGO DOOR CUTOUT AFT CORNER SEAL REST IS CORRODED AROUND THE NUTPLATE. REMOVED AND REPLACED THE FORWARD CARGO DOOR CUTOUT AFT CORNER SEAL REST IAW…
- 20 Jan 2018
Seat Track, corroded
AFT WET AREA AT FRAME 84 RBL12, SEAT TRACK IS CORRODED. PERFORMED A DOUBLER AND FILLER REPAIR IAW SRM 53-23-10, REPAIR 4.
- 20 Jan 2018
Shear Panel, corroded
AFT WET AREA BETWEEN FRAMES 87 AND 88, LBL 10 TO RBL 10 CENTER SHEAR PANEL IS CORRODED. REMOVED AND REPLACED THE SHEAR PANEL IAW SRM 51-42-01, SRM 51-23-04.
- 20 Jan 2018
Shear Panel, corroded
AFT WET AREA BETWEEN FRAMES 87 AND 88, RBL 13 TO 45. RT SHEAR PANEL IS CORRODED. REMOVED AND REPLACED THE SHEAR PANEL IAW SRM 51-42-01, 51-41-02, 51-43-04,…
- 20 Jan 2018
Upper Sheet, corroded
AFT WET AREA BETWEEN FRAMES 85 AND 86, RBL 12 RT UPPER SHEET IS CORRODED. REMOVED AND REPLACED THE UPPER SHEET IAW SRM 51-41-01, 51-40-02, 51-43-04, AND…
- 20 Jan 2018
Stand Off, corroded
AFT WET AREA AT FRAME 87, RBL 35 RT NUTPLATE STANDOFF IS CORRODED. REPLACED NUTPLATE STANDOFF IAW SRM 51-23-05.
- 20 Jan 2018
Splice, corroded
AFT WET AREA AT FRAME 89, RBL 12 RT SPLICE CORRODED. REMOVED AND REPLACED THE SPLICE IAW SRM 51-40-08.
- 20 Jan 2018
Floor Support, corroded
AFT WET AREA AT FRAME 89, RBL 45 RT FLOOR SUPPORT IS CORRODED. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-42-01, AND 51-43-03.
- 20 Jan 2018
Support, corroded
AFT WET AREA BETWEEN FRAMES 88 AND 89, LBL 45 SUPPORT PANEL IS CORRODED. REMOVED AND REPLACED SUPPORT PANEL IAW SRM 51-40-08.
- 20 Jan 2018
Support, corroded
AFT WET AREA BETWEEN FRAMES 89 AND 90, RBL 12 RT SUPPORT IS CORRODED. REMOVED AND REPLACED THE SUPPORT IAW SRM 51-40-08, 51-23-04, 51-23-05, AND 51-23-06.
- 20 Jan 2018
Angle, corroded
AFT WET AREA BETWEEN FRAMES 89 AND 90, RBL 12, THE INTERCOSTAL ATTACHED TO THE RT BEAM IS CORRODED. REMOVED AND REPLACED THE L ANGLE IAW SRM 51-23-04,…
- 20 Jan 2018
Gusset, corroded
GUSSET AT FRAME 90, LBL 12 IS CORRODED. REMOVED AND REPLACED THE GUSSET IAW SRM 51-40-08.
- 20 Jan 2018
Gusset, corroded
AFT WET AREA AT FRAME 90, RBL 12 RT GUSSET IS CORRODED, REMOVED AND REPLACED THE GUSSET IAW SRM 51-40-08.
- 20 Jan 2018
Support, corroded
FWD WET AREA RT SUPPORT AT FRAMES 13 AND 14 CORRODED. REMOVED AND REPLACED THE SUPPORT SRM 51-23-04, 51-23-05, 51-23-06, AND 51-40-08.
- 20 Jan 2018
Gusset, corroded
AFT WET AREA AT FRAME 90, LBL 12 LT MIDDLE GUSSET IS CORRODED. REMOVED AND REPLACED THE GUSSET IAW SRM 51-40-08.
- 20 Jan 2018
Angle, corroded
SURFACE CORROSION ON BOTH LOWER ANGLES ON PANEL 1441FR. REMOVED AND REPLACED LOWER ANGLES ON 1441FR REF SRM 51-40-02, 51-40-08 AMM 20-10-07. RESTORED SURFACE…
- 20 Jan 2018
Angle, corroded
SURFACE CORROSION ON BOTH LOWER ANGLES ON PANEL 1431DL. REMOVED AND REPLACED LOWER ANGLES ON 1431DL REF. SRM 51-40-02,51-40-08 AMM 20-10-07. RESTORED SURFACE…
- 1 Sep 2017
Battery, inoperative
FOUND L2 DOOR EXIT LIGHT INOPERATIVE DURING RTWO DAY CHECK. R & R THE EMERGENCY LIGHT BATTERY NR 3 IAW AMM 33-55-01. OPS CHECKED GOOD.
- 7 Apr 2015
Battery, inoperative
MAINTENANCE REPORTED THE L1 DOOR EMERGENCY EXIT LIGHT WAS INOPERATIVE. MAINTENANCE R & R EMERGENCY BATTERY IAW AMM AND OPS CHECKED GOOD. ACFT IS GOOD FOR…
- 27 Jan 2014
Slide, malfunctioned
CREW REPORTED THAT DURING EMERGENCY EVACATION OF ACFT AT GATE, THE R1 DOOR DID NOT FULLY OPEN AND THE SLIDE DID NOT DEPLOY. F/O KICKED DOOR AND THE SLIDE…
- 7 Nov 2013
Flashlight, inoperative
CREW REPORTED THAT THE F/O FLASHLIGHT WAS INOPERATIVE. MAINTEANCE R & R F/O FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.