N405YX
2013 Embraer S A ERJ 170-200 LR standard FAA →
registration
- 2013
service difficulty reports
36 reports
- 5 Sep 2026
Skin, dented
REPAIRED DENT UNDER CA DV WINDOW BY INSTALLING DOUBLER AND FILLER REPAIR ON FUSELAGE SKIN BETWEEN FR10-FR-11 STGR 15L-17L. REF: ETD2025-170-928451 AND EMB SRM…
- 5 Sep 2026
Skin, corroded
AFT CARGO SKIN AT FR 85/86 STRG 23L RIVET HAS CORROSION. PERFORMED PERMANENT REPAIR,STRINGER 23L REPLACEMENT AND SPLICE, AT AFT CARGO SKIN FR 85/86 STRINGER…
- 24 Aug 2024
Windshield, cracked
CA WINDSHIELD CRACKED IN FLIGHT AT 27000 FT. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R&R CA WINDSHIELD.
- 15 Jun 2024
Glowstrip, unsecure
PHOTOLUMINESCENT STRIP DETACHED FROM FLOORING IN FIRST CLASS/GALLEY AREA. RESECURED PHOTOLUMINESCENT STRIP.
- 15 May 2024
Floorbeam, chafed
WHILE IN HEAVY CHECK - INTERNAL FLOOR STRUCTURE CENTER CROSSBEAM AT FR 78 HAS 2EA SPOTS OF CHAFFING DAMAGE ON BOTTOM EDGE AS SEEN THROUGH AFT CARGO. COMPLIED…
- 3 Nov 2023
Unknown, unknown
R2 DOOR EMERGENCY LIGHT AND FLIGHT LIGHT INOPERATIVE, REPLACED NUMBER 4 EMERGENCY BATTERY, OPS CHECK GOOD.
- 19 May 2021
Shear Tie, corroded
CORRODED SHEAR CLIP AT FR 85, STRINGER 28R. REMOVED AND REPLACED SHEAR CLIP PN 170-66064-001 IAW EMB SRM 51-40-08, 51-40-02, AND 51-23-06.
- 26 Nov 2020
Power Supply, inoperative
AFT GALLEY EMERGENCY EXIT SIGN FOR CENTER AISLE WILL NOT ILLUMINATE. R & R EMERGENCY LIGHT POWER UNIT NR 3, IAW AMM 33-50-01.
- 2 Jun 2020
Slide, inoperative
GIRT BAR STUCK L1. FOUND L1 DOOR EMERGENCY EVACUATION SLIDE TO BE INOP, SEPARATED FROM THE BACKBOARD. R & R L1 DOOR EMERGENCY EVACUATION SLIDE IAW AMM 25-65-01.
- 22 Feb 2020
Power Supply, inoperative
EMERGENCY LIGHT BATTERY FAULT ON EICAS, SOME EMERGENCY LIGHTS INTERMITTENT ON CEILING AND R2 EXIT. R&R AFT RH INBOARD EMERGENCY LIGHT POWER UNIT IAW AMM…
- 25 May 2019
Power Unit, inoperative
COCKPIT EMERGENCY LIGHT DOES NOT ILLUMINATE. R&R EMERGENCY LIGHT POWER UNIT IN FWD RT GALLEY BY R1 PANEL IAW AMM 33-50-01. OPS CHECK GOOD.
- 4 Jan 2019
Beam, corroded
CORROSION AT THE FWD CARGO HORIZONTAL BEAM BETWEEN FR 24-27.
- 4 Jan 2019
Floorbeam, corroded
CORROSION RT INBD BEAM AT FR 84.
- 30 Dec 2018
Shear Panel, corroded
WHILE ACFT IN HEAVY CHECK FOUND CORROSION AT RH SHEAR PANEL AT FR 87-88. REMOVED AND REPLACED RH SHEAR PANEL REF SRM 51-23-04. APPLIED SURFACE PROTECTION ON…
- 30 Dec 2018
Shear Panel, corroded
WHILE ACFT IN HEAVY CHECK FOUND CORROSION CENTER SHEAR PANEL AT FR 87-88 REMOVED AND REPLACED RH SHEAR PANEL REF SRM 51-23-04. APPLIED SURFACE PROTECTION ON…
- 30 Dec 2018
Gusset, corroded
WHILE ACFT IN HEAVY CHECK FOUND CORROSION AT RH OB GUSSET AT FR90, REMOVED AND REPLACED RH OB GUSSET AT FR 90 REF. E175 SRM 51-40-08, 51-23-01. RESTORED…
- 30 Dec 2018
Splice, corroded
WHILE ACFT IN HEAVY CHECK FOUND CORROSION_R.HAND I/B SPLICE FR.90,REMOVED AND REPLACED R.HAND I/B BEAM SPLICE REF:SRM 51-21-01, SRM 51-40-08. ACFT REMAINS IN…
- 30 Dec 2018
Support, corroded
WHILE ACFT IN HEAVY CHECK MAINT FOUND CORROSION FWD WET AREA FWD R.HAND SILL BETWEEN FR.13 AND FR.14,REMOVED AND REPLACED RH SILLBETWEEN FR.13-14 REF. E175…
- 30 Dec 2018
Seat Track, corroded
WHILE ACFT IN HEAVY CHECK MAINT FOUND CORROSION FWD WET AREA L.HAND SEAT TRACK BETWEEN FR.19 AND FR.20,REMOVED AND REPLACED WITH NEW FWD WET AREA L.HAND SEAT…
- 30 Dec 2018
Beam, corroded
WHILE ACFT IN HEAVY CHECK MAINT FOUND INBD BEAM IS CORRODED BETWEEN FR 86-89,REMOVED AND REPLACED RH INBD BEAM BETWEEN FR 86-89 REF. E175 SRM…
- 15 Dec 2018
Intercostal, corroded
RT INBD INTERCOSTAL IS CORRODED BETWEEN FR 90-91. BLENDED RT INBD INTERCOSTAL BETWEEN FR 90-91. 0.034" REMAINING ON INTERCOSTAL, 0.036" ON ADJACENT L ANGLE.…
- 14 Dec 2018
Doubler, corroded
CORROSION INNER DOUBLER ON PANEL 192CR. REMOVED AND REPLACED INNER DOUBLER PN: 170-13414-003 REF SRM 51-40-08. SEE W/O H6577 SN 413 FOR WORK DETAILS. AIRCRAFT…
- 14 Dec 2018
Doubler, corroded
CORROSION INNER DOUBLER ON PANEL 192BL. REMOVED AND REPLACED INNER DOUBLER PN: 170-13414-003 REF SRM 51-40-08. SEE W/O H6577 SN 416 FOR WORK DETAILS. AIRCRAFT…
- 14 Dec 2018
Threshold, corroded
MAJOR REPAIR: CORROSION FOUND, AT FWD AND AFT GIRT BAR FITTINGS, WHILE PERFORMING L1 DOOR LOWER BEAM REWORK. REMOVED CORROSION BY BLENDING AT FWD AND AFT GIRT…
- 13 Dec 2018
Seat Track, corroded
CORROSION_FWD WET AREA R.HAND SEAT TRACK AT FR.17 HAS SURFACE CORROSION AS MARKED. REMOVED CORROSION BY BLENDING. 100% PERCENT THROUGH DAMAGE, FOUND TO BE OUT…
- 12 Dec 2018
Finger Doubler, corroded
MAJOR REPAIR: AFT CARGO DOOR HORIZONTAL BEAM STOP FITTING LOCATED AT FR 76-77 HAS SURFACE OXIDATION ON FASTENER AS MARKED WITH RED GREASE PENCIL. BLENDED OUT…
- 17 May 2018
Power Supply, inoperative
EMERGENCY LIGHT INOPERATIVE AT ROW 12. R & R THE POWER SUPPLY IAW AMM 33-50-01.
- 10 Apr 2017
Shear Panel, corroded
AFT CABIN RT SHEAR PANEL BETWEEN FRAMES 87- 88. REMOVED AND REPLACED THE SHEAR PANEL, ALODINED AND TOP COATED IAW SRM 51-40-02, 51-23-04, 51-23-05, AND…
- 10 Apr 2017
Gusset, corroded
AFT CABIN GUSSET PLATE AT FRAME 90 CORRODED. REMOVED AND REPLACED THE GUSSET, ALODINED AND TOP COATED IAW SRM 51-41-02, 51-23-04, 51-23-06, 51-42-01, AND…
- 10 Apr 2017
Floor Support, corroded
FWD CABIN RT FLOOR SUPPORT BETWEEN FRAMES 12 - 14 CORRODED. REMOVED AND REPLACED THE FLOOR SUPORT IAW SRM 51-21-01, 51-41-02, 51-43-04, 51-23-04, 51-23-05,…
- 6 Jan 2017
Controller, malfunctioned
CREW RECEIVED A BLEED 2 OVERPRESSURE MESSAGE. NOTED THAT THE CABIN PRESSURE WAS CLIMBING FOLLOWED BY A CABIN ALTITUDE HIGH WARNING MESSAGE. DONNED OXYGEN…
- 23 May 2016
Battery Pack, inoperative
CREW REPORTED THAT THE OVERHEAD CABIN EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE R & R EMERGENCY BATTERY IAW AMM AND OPS CHECKED GOOD.
- 21 May 2016
Connector, disconnected
CREW REPORTED THAT THE RAINBOW LIGHTS WERE NOT ALL COMING ON DURING TEST. MAINTENANCE PLACED ON MEL AND LATER FOUND AFT LAV PCB CONNECTOR DISCONNECTED.…
- 17 May 2016
Battery Pack, inoperative
CREW REPORTED THAT THE EMERGENCY LIGHT OVER ROW 4 WAS INOPERATIVE. MAINTENANCE R & R EMERGENCY BATTERY IAW AMM AND OPS CHECKED GOOD.
- 5 Jun 2015
Light, damaged
MAINTENANCE REPORTED THAT THE PHOTOLUMINESCENT STRIP AT ROW 1D WAS DAMAGED. MAINTENANCE R & R PHOTOLUMINESCENT STRIP AT ROW 1D IAW AMM AND OPS CHECKED GOOD.
- 24 Nov 2014
Unknown, unknown
CREW REPORTED THAT THE L2 DOOR WAS DIFFICULT TO ARM. MAINTENANCE INSPECTED AND FOUND THE FLEX BALL CABLE IN GOOD SHAPE. MAINTENANCE REPORTS THAT THE ESCAPE…