N403A
1986 McDonnell Douglas DC-9-82(MD-82) standard FAA →
earlier registrations
2 past records
- 1986
service difficulty reports
89 reports
- 5 Sep 2019
Bottle, low pressure
AIRCRAFT NOT GROUNDED: L4 DOOR ASSIST BOTTLE BELOW PS CHECK MINIMUM 1250 PSI AT 70 F. SERVICE L4 DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001.
- 13 Jul 2016
Battery Pack, no test
EMERGENCY LIGHTS IN COCKPIT AND GALLEY AREA REMAIN ILLUMINATED WITH AIRCRAFT POWER OFF. REMOVED AND REPLACED BATTERY PACK B5-23 IAW AMM AMM 33-53-00. OPS…
- 13 Jul 2016
Battery Pack, no test
DURING ACCOMPLISHMENT OF WORK CARD 0801, THE EMERGENCY LIGHTS BETWEEN ROWS 17 AND 22 FAILED TO TEST. REMOVED AND REPLACED THE BATTERY PACK B5-104 IAW AMM…
- 13 Jul 2016
Battery Pack, no test
DURING ACCOMPLISHMENT OF WORK CARD 5403, EMERGENCY BATTERY PACK AB5-1 FAILED TO TEST. REMOVED AND REPLACED THE BATTERY PACK IAW AMM 33-60-98. OPS TESTED NORMAL.
- 13 Jul 2016
Battery Pack, no test
DURING ACCOMPLISHMENT OF WORK CARD 5403, EMERGENCY BATTERY PACK AB5-2 FAILED TO TEST. REMOVED AND REPLACED THE BATTERY PACK IAW AMM 33-60-98. OPS TESTED NORMAL.
- 13 Jul 2016
Battery Pack, no test
DURING ACCOMPLISHMENT OF WORK CARD 5403, EMERGENCY BATTERY PACK AB5-4 FAILED TO TEST. REMOVED AND REPLACED THE BATTERY PACK IAW AMM 33-60-98. OPS TESTED NORMAL.
- 29 Apr 2016
Actuator, faulty
AIRCRAFT WAS GNDED. AIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT WAS OVERWEIGHT. DURING FLIGHT, ACFT WOULD NOT PRESSURIZE & OUTFLOW VLV WAS…
- 30 Mar 2016
Battery, discharged
AIRCRAFT WAS NOT GNDED. EMER LIGHT AT AFT VAULT DOOR WILL NOT GO OUT. R & R BATTERY ASSEMBLIES B5-27 & 5B-28. ACCOMPLISHED GOOD OPERATIONAL CHECK IAW AMM…
- 30 Mar 2016
Battery, discharged
AIRCRAFT WAS NOT GNDED. EMER SIGNS ABOVE RT & LT FWD OVERWING EXITS WILL NOT STAY ON. R & R BATTERY ASSEMBLY & ACCOMPLISHED GOOD OPERATIONAL CHECK IAW AMM…
- 30 Mar 2016
Battery, discharged
AIRCRAFT WAS NOT GNDED. EMER LIGHT AT AFT VAULT DOOR WILL NOT GO OUT. R & R BATTERY ASSEMBLIES B5-27 & 5B-28. ACCOMPLISHED GOOD OPERATIONAL CHECK IAW AMM…
- 2 Nov 2015
Skin, delaminated
DELAMINATION AT END OF LT ELEVATOR, OTBD TE. INJECTED WITH RESIN & CLAMPED IAW SRM 55-03-00-001 FIGURE 5 & EA 255658.
- 29 Sep 2015
Slide, low pressure
DURING B CHECK INSPECTIONS, AMT FOUND THE FWD SERVICE DOOR ESCAPE SLIDE WITH CYLINDER PRESS THAT WAS BELOW THE SERVICEABLE LIMIT. THE FWD SERVICE DOOR ESCAPE…
- 10 Jun 2015
Skin, corroded
FUSELAGE SKIN BETWEEN STATIONS 230 & 257 IS CORRODED FROM LONGERONS 29L TO 30R. REPAIRED SKIN IAW SRM 53-04-03 FIG 4.
- 19 May 2015
Check Valve, stuck
AIR INTERRUPT, EMER NOT DECLARED. DURING CLIMB, TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED. ACCOMPLISHED WC 36-95-14 & FOUND RT TAIL COMPARTMENT…
- 19 May 2015
Sensor, faulty
AIR INTERRUPT, EMER NOT DECLARED. DURING CLIMB, TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED. ACCOMPLISHED WC 36-95-14 & FOUND RT TAIL COMPARTMENT…
- 19 May 2015
Sensor, faulty
AIR INTERRUPT, EMER NOT DECLARED. DURING CLIMB, TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED. ACCOMPLISHED WC 36-95-14 & FOUND RIGHT TAIL COMPARTMENT…
- 18 May 2015
Seal, leaking
AIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT OVERWEIGHT. DURING CLIMB THE AIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED. ACCOMPLISHED TAIL…
- 24 Oct 2014
Light, inoperative
AFT STAIRWAY EMER EXIT SIGN INOPERATIVE. REPLACED LIGHT ASSEMBLY FOR AFT STAIRWAY EMER EXIT SIGN. OPERATIONS CHECKED NORMAL.
- 17 Jun 2014
Skin, damaged
VERTICAL STABILIZER LE SKIN BELOW THE ZFS 52.267 SPLICE HAS A NR OF HOLES DAMAGED IN THE SKIN & THE LT SPAR CAP. INSTALLED PLUG BUSHING IAW SRM 55-03-00…
- 28 May 2014
Stop Fitting, cracked
MID CARGO FWD DOOR STOP FITTING CRACKED. R & R STOP FITTING IAW AARD 51-00-05-1.
- 28 May 2014
Stop Fitting, cracked
MID CARGO STOP PAD, FWD UPPER CORNER CRACKED. R & R FITTING IAW AARD 51-00-05-1.
- 27 May 2014
Stop Fitting, cracked
FORWARD CARGO STOP PAD FITTING CRACKED. R & R FITTING IAW AARD 51-00-05-1.
- 21 Apr 2014
Battery Pack, discharged
FORWARD TWO OVERWING EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED BATTERY PACK B5-103, OPERATIONS CHECKED NORMAL.
- 21 Apr 2014
Smoke Detector, inoperative
LEFT AFT LAVATORY SMOKE DETECTOR INOPERATIVE ON TEST. R & R LT AFT LAVATORY SMOKE DETECTOR, OPERATIONS CHECKED NORMAL.
- 19 Apr 2014
Light, inoperative
EMERGENCY LIGHT JUST FWD OF THE AFT SERVICE DOOR ON SIDE WALL INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT, OPERATIONS CHECKED NORMAL.
- 15 Apr 2014
Connector, faulty
ABI INFLIGHT SJD - DFW. CREW REPORTED RAPID DEPRESSURIZATION DUE TO LOSS OF AUTO PRESS CONTROLLERS. EMERGENCY DECLARED FLIGHT DIVERTED ABI & LANDED WITHOUT…
- 30 Mar 2014
Controller, inoperative
CREW REPORTED NR 2 AUTOMATIC CABIN PRESSURE CONTROLLER INOPERATIVE WITH NR 1 CONTROLLER PREVIOUSLY PLACARDED. EMERGENCY DECLARED, DIVERTED, AND LANDED WITHOUT…
- 25 Oct 2013
Battery Pack, discharged
EMERGENCY LIGHTS AT MID CABIN POSITION FAILED TEST. REPLACED EMERGENCY LIGHT BATTERY PACK AT MID CABIN POSITION. OPERATIONS CHECKED NORMAL.
- 17 Jun 2013
Controller, inoperative
AIRCRAFT LOST CABIN PRESSURIZATION IN AUTO MODE. EMERGENCY DECLARED FLIGHT DIVERTED ATL LANDED WITHOUT INCIDENT. REPLACED NR 1 & 2 PRESSURE CONTROLLER. SYSTEM…
- 1 Apr 2013
Sensor, leaking
MCI - CREW REPORTED CABIN ALTITUDE WARNING. EMERGENCY DESCENT INITIATED AND O2 MASKS WERE MANUALLY DEPLOYED. EMERGENCY DECLARED FLIGHT LANDED MCI WITHOUT…
- 2 Mar 2013
Actuator, inoperative
ORD - CREW REPORTED UNABLE TO CONTROL PRESSURIZATION IN AUTOMATIC CONTROL. FLIGHT RETURNED ORD LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE.…
- 9 Dec 2012
Controller, inoperative
DFW - CREW REPORTED HAD RAPID DEPRESSURIZATION WHILE IN AUTO. SWITCHED TO MANUAL CONTROL AND WAS ABLE TO CONTROL. NO FLOW LIGHTS ILLUMINATED. EMERGENCY…
- 29 Nov 2012
Frame, cracked
CUT BELL FRAME ANGLE BETWEEN LONGERONS 4 AND 5 RIGHT AT STATION 1338, FOR OTHER MAINTENANCE. INSTALLED BELL FRAME REPAIR ANGLE AND BELL FRAME REPAIR STRAP PER…
- 29 Nov 2012
Tee Fitting, scratched
SCRATCHES IN RADIUS OF RIGHT AFT PRESSURE BULKHEAD T CHORD, IN RIGHT AFT LAVATORY AREA, ON AFT SIDE OF FRAME, BETWEEN LONGERONS 8 AND 17 RIGHT. INSTALLED…
- 6 Nov 2012
Skin, cracked
STATION 826 CENTER WING SKIN CAP CRACKED. INSTALLED DOUBLER PER SRM 51-70-05 AND EA MD80-57-026832.
- 25 Oct 2012
Beam, corroded
AFT CARGO HAS CORROSION ON LOWER DOOR BEAM FROM STATIONS 1155 TO 1165. INSTALLED DOUBLER FROM STATIONS 1155 TO 1212 PER AARD 53-10-00-3.
- 23 Oct 2012
Cusp Web, cracked
CRACK IN LEFT CUSP AT STATION 806 UNDER NUMBER 1 SEAT TRACK. INSTALLED NEW CUSP SHEET FROM STATIONS 788 TO 807 PER AARD 51-00-05-1.
- 23 Oct 2012
Structure, corroded
CORROSION FOUND UNDER G2 TIEDOWN AT STATION 218, RIGHT BUTTLINE 11. INSTALLED DOUBLER PER AARD 53-20-00-16.
- 23 Oct 2012
Skin, damaged
SKIN STATIC DISCHARGE BLEND BEYOND LIMITS BETWEEN FRAMES 408 AND 427 AND LONGERONS 19 AND 21 LEFT. INSTALLED CLASS 3 DOUBLER PER SRM 53-04-03 FIGURE 3.
- 23 Oct 2012
Skin, damaged
FUSELAGE SKIN FROM STATIONS 389 TO 400 BETWEEN LONGERONS 20 AND 21 LEFT, BLENDED AREA OUT OF LIMITS. INSTALLED CLASS 3 DOUBLER PER SRM 53-04-03 FIGURE 2.
- 23 Oct 2012
Skin, damaged
SKIN STATIC DISCHARGE BLEND BEYOND LIMITS BETWEEN FRAMES 427 AND 446 AND LONGERONS 19 AND 20 LEFT. INSTALLED INTERNAL DOUBLER PER SRM 53-04-02.
- 23 Oct 2012
Skin, damaged
PREVIOUSLY BLENDED AREA OUT OF LIMITS AT STATION 364 BETWEEN LONGERONS 21 AND 22 LEFT. INSTALLED CLASS 3 DOUBLER PER SRM 53-04-03 FIGURE 4.
- 23 Oct 2012
Web, cracked
FORWARD WEB CRACKED AT STATION 209, LONGERON 11 LEFT. INSTALLED DOUBLER PER AARD 53-10-00-11.
- 23 Oct 2012
Fitting, cracked
LEFT AFT LAVATORY, PRESSURE BULKHEAD OUTBOARD SIDE AT LONGERON 9 LEFT, LOWER END CLIP IS CRACKED. INSTALLED NEW CLIP PER AARD 51-00-05-1.
- 23 Oct 2012
Longeron, damaged
LONGERON 11 LEFT AT STATION 855 DAMAGED. ACCOMPLISHED SPLICE REPAIR TO LONGERON 11 LEFT AT STATION 855 PER SRM 53-02-00 FIGURE 3.
- 23 Oct 2012
Longeron, cracked
FORWARD LONGERON 2 LEFT CRACKED AT STATION 160. ACCOMPLISHED SPLICE REPAIR PER SRM 53-02-00 FIGURE 18.
- 17 Oct 2012
Longeron, cracked
FORWARD LONGERON 3 LEFT CRACKED AT STATION 160. REMOVED DAMAGED LONGERON SECTION AND ACCOMPLISHED SPLICE REPAIR PER AARD 51-00-05-1 AND SRM 53-02-00 FIGURE 18.
- 19 Feb 2012
Gcu, inoperative
CREW REPORTED RIGHT GENERATOR FAILED IN FLIGHT. EMERGENCY DECLARED FLIGHT LANDED WITHOUT INCIDENT. REPLACED RIGHT GENERATOR CONTROL UNIT. SYSTEM GROUND CHECK…
- 24 Oct 2011
Charger, inoperative
CEILING LIGHTS INOPERATIVE. REPLACED BATTERY CHARGER FOR CEILING LIGHTS. OPS CHECK NORMAL.
- 9 Oct 2011
Hydraulic Line, leaking
DFW - CREW REPORTED RIGHT HYDRAULIC SYSTEM FAILED. EMERGENCY DECLARED FLIGHT LANDED DFW WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED HYDRAULIC…
- 27 Jul 2011
Duct, damaged
ICT - CREW REPORTED TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED DURING CLIMBOUT. EMERGENCY DECLARED FLIGHT RETURNED ICT LANDED WITHOUT INCIDENT.…
- 11 Apr 2011
Battery Pack, discharged
SEAT MOUNTED EMERGENCY LIGHTS FROM SEATS 20D TO 32D INOPERATIVE. REPLACED BATTERY PACK AT AB-3 POSITION. OPS CHECK NORMAL.
- 11 Apr 2011
Battery Pack, discharged
SEAT MOUNTED EMERGENCY LIGHTS FROM SEATS 20D TO 32D INOPERATIVE. REPLACED BATTERY PACK AT AB-4 POSITION. OPS CHECK NORMAL.
- 11 Jun 2010
Duct, damaged
MSP - CREW REPORTED TAIL COMPARTMENT HIGH LIGHT ILLUMINATED DURING FLIGHT. LIGHT WENT OUT AFTER POWER REDUCED BUT CAME ON MOMENTARILY SEVERAL TIMES DURING…
- 1 May 2010
Battery Pack, discharged
EMERGENCY LIGHTS BETWEEN FORWARD LAVATORY AND GALLEY. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS BETWEEN FORWARD LAVATORY AND GALLEY. OPS CHECKED NORMAL.
- 1 May 2010
Battery Pack, discharged
LEFT AND RIGHT AFT OVERWING HATCH OVERHEAD EXIT LIGHTS INOPERATIVE. REPLACED BATTERY PACK. OPS CHECKED NORMAL.
- 15 Mar 2010
Angle, cracked
AFT PRESSURE BULKHEAD LEFT T-ANGLE SHOWS INDICATION OF CRACK LONGERON 14 LEFT. REMOVED AND REPLACED T ANGLE PER IAW EA 009163.
- 15 Dec 2009
Bulkhead, cracked
RADOME BULKHEAD CRACKED AT RIGHT UPPER RADOME ALIGNMENT PIN. CUT OUT DAMAGE AND INSTALLED DOUBLER PER AARD 53-10-00-19.
- 15 Dec 2009
Frame, cracked
AFT FUSELAGE CANT FRAME WEB AT STATION 1463 CRACKED AT LONGERON 18 RIGHT. STOP DRILLED CRACK AND INSTALLED DOUBLER.
- 12 Nov 2009
Light, cracked
EMERGENCY LIGHT COVER AT FORWARD CORNER OF FORWARD GALLEY SERVICE DOOR FELL OFF. REPLACED LIGHT ASSEMBLY.
- 11 Sep 2009
Clamp, loose
TAIL COMPARTMENT TEMPERATURE LIGHT CAME ON DURING CLIMB AND REMAINED ON AFTER 2 MINUTES. THE LIGHT WAS ON AND OFF DURING APPROACH. RETURNED TO DFW AND LANDED…
- 6 Jun 2009
Control Cable, out of rig
JFK - INFLIGHT LGA-LGA. DURING FUNCTIONAL FLIGHT CHECK THE LANDING GEAR DOOR WAS UNABLE TO CLOSE. EMERGENCY DECLARED, LANDED JFK WITHOUT INCIDENT.…
- 5 Jun 2009
Valve, inoperative
LGA - AFTER TAKEOFF LEFT GEAR RED LIGHT REMAINED ON AFTER RETRACTION. LANDED LGA WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED LANDING…
- 21 Apr 2009
Valve, leaking
PSP - CREW REPORTED TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED. EMERGENCY DECLARED, RETURNED TO PSP WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE.…
- 2 Jul 2008
Clamp, leaking
TUL INFLIGHT T9610/02JUL. CREW REPORTED TAIL COMPARTMENT HIGH TEMPERATURE INDICATION JUST AFTER TAKEOFF. RETURNED TO TUL AND LANDED WITHOUT INCIDENT. REPLACED…
- 21 Aug 2007
Engine, making metal
BNA INFLIGHT T1531/21AUG - NUMBER ONE ENGINE OIL CLOG LIGHT ILLUMINATED DURING CLIMB. REDUCED NUMBER ONE ENGINE TO IDLE AND RETURNED TO BNA AND LANDED WITHOUT…
- 13 May 2007
Battery Pack, inoperative
LGA - EMERGENCY LIGHTS AT FORWARD CABIN INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS AT FORWARD CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 13 May 2007
Battery Pack, inoperative
LGA - EMERGENCY LIGHTS AT TAIL CONE INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS AT TAIL CONE. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 20 Mar 2007
Light, missing
ORD - EMERGENCY EXIT LIGHT AT FORWARD GALLEY WALL FLOOR MISSING. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY AT FORWARD GALLEY WALL FLOOR. SYSTEM GROUND CHECKED…
- 19 Dec 2006
Controller, inoperative
DFW - FLIGHT CREW REPORTED CABIN PRESSURIZATION PROBLEM AT FLIGHT LEVEL 320. AFTER TEN MINUTES CABIN ALT LIGHT ILLUMINATED AND NO INDICATION FROM CONTROLLER…
- 27 May 2006
Battery Pack, discharged
LGA - CEILING EMERGENCY LIGHTS AT REAR COMPARTMENT LAVATORY DROP DOWN PANEL INOPERATIVE. REPLACED BATTERY PACK AT RIGHT HAND AFT LAVATORY F5 27 FOR…
- 27 May 2006
Battery Pack, discharged
LGA - EMERGENCY LIGHT AT TAIL CONE SLIDE INOPERATIVE. REPLACED BATTERY PACK AT B5 27 FOR EMERGENCY LIGHT AT TAIL CONE SLIDE. SYSTEM GROUND CHECKED NORMAL…
- 16 Jan 2006
Battery Pack, inoperative
LGA - EMERGENCY LIGHTS AT ROW 21 AFT INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS AT ROW 21 AFT. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 25 Dec 2004
Battery Pack, discharged
DEN - AFT ACCY EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK FOR AFT ACCY EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 6 Apr 2004
Battery Pack, inoperative
DFW - CEILING EMERGENCY LIGHTS AT ROWS 28 THROUGH 30 INOPERATIVE. REPLACED BATTERY PACK FOR CEILING EMERGENCY LIGHTS AT ROWS 28 THROUGH 30. SYSTEM GROUND…
- 28 Jan 2004
Apu, smoke
DFW INFLIGHT T563/28 SMOKE IN CABIN AFTER TAKEOFF AND REMAINED UNTIL LANDING. RETURNED TO DFW AND LANDED WITHOUT INCIDENT. REPLACED AUXILLARY POWER UNIT.…
- 25 Jan 2004
Valve, inoperative
DFW INFLIGHT T2427/25 FLIGHT ATTENDANT REPORTED SMOKE IN CABIN INCREASING IN INTENSITY AT MAX POWER, EPR 1.95 PACKS ON AND APU OFF. RETURNED TO DFW. LANDED…
- 18 Aug 2003
Battery Pack, discharged
LGA - DURING OVERNIGHT MAINTENANCE, AFT CABIN EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED AFT CABIN EMERGENCY EXIT LIGHT BATTERY. SYSTEM GROUND CHECKED NORMAL…
- 18 Feb 2003
Battery, inoperative
DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT SEAT 22 INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT BATTERY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 2 Feb 2003
Light, inoperative
MIA - DURING OVERNIGHT MAINTENANCE, CEILING EMERGENCY EXIT LIGHT INOPERATIVE. CLEANED CEILING EMERGENCY EXIT LIGHT GROUND. SYSTEM GROUND CHECKED NORMAL…
- 11 Mar 2002
Flashlight, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, FORWARD ENTRY EMERGENCY PORTABLE FLASHLIGHT INOPERATIVE. REPLACED FORWARD ENTRY EMERGENCY PORTABLE FLASHLIGHT. SYSTEM…
- 26 Jan 2002
Charger, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT OVERHEAD ENTRY LIGHT DIM. REPLACED FIRST CLASS BATTERY AND CHARGER. SYSTEM GROUND CHECKED NORMAL OPERATION.…
- 10 Jan 2002
Light, inoperative
PHX - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT R1 DOOR INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL…
- 19 Jul 2001
Wire, inoperative
LAX - DURING OVERNIGHT MAINTENANCE, SEAT MOUNTED EMERGENCY EXIT LIGHTS SEATS ROW 1 THROUGH 20 DIM. SPLICED WIRES TO EMERGENCY EXIT LIGHTS AT ROW 13. SYSTEM…
- 22 Oct 1999
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, FORWARD FLIGHT ATTENDANT PORTABLE EMERGENCY LIGHT INOPERATIVE. REPLACED FORWARD FLIGHT ATTENDANT PORTABLE EMERGENCY LIGHT…
- 20 May 1999
Skin, corroded
TUL - FOUND CORROSION ON A/C FUSELAGE SKIN STAITON 380 AND 402, UNDER ANTENNAS. REMOVED CORROSION PER SRM 51-10-3 AND TREATED AREA. (M)
- 26 Jan 1997
Unsafe Warning, illuminated
ORD - FLT 2358 - DURING APPROACH TO ORD IN ICING CONDITIONS WHEN LANDING GEAR EXTENDED, NOSE LANDING GEAR INDICATED UNSAFE. RECYCLED LANDING GEAR TWO CYCLES…
- 9 Nov 1996
Switch, defective
DFW - FLT 1568 - EN ROUTE SJC/DFW - DURING CRUISE AT FL 370, CABIN OXYGEN LIGHT ILLUMINATED AND ALL PAX OXYGEN MASKS DROPPED SUCCESSFULLY. CABIN ALTITUDE WAS…
- 16 Dec 1995
Charger, defective
DFW - DURING OVERNIGHT CHECK, FOUND THE EMERGENCY EXIT SIDE LIGHTS ABOVE FORWARD LEFT AND RIGHT ESCAPE HATCHES INOPERATIVE. REPLACED BATTERY CHARGER ASSEMBLY.…