N402YX
2013 Embraer S A ERJ 170-200 LR standard FAA →
registration
- 2013
service difficulty reports
38 reports
- 3 Nov 2026
Access Panel, chafed
WHILE IN HEAVY CHECK, RH WING BIRDSTRIKE PANEL HAS CHAFING ALONG I/B SIDE.FABRICATED, LOCATED AND DRILLED REPAIR DOUBLER FOR RH WING BIRD STRIKE PANEL I/B…
- 3 Nov 2026
Access Panel, chafed
LEFT WING FIXED LEADING EDGE OVER PYLON IS CHAFED IN MULTIPLE AREAS.FABRICATED, LOCATED AND DRILLED LT WING FIXED LEADING EDGE DOUBLER OVER PYLON,AND…
- 30 Oct 2026
Doubler, corroded
WHILE IN HEAVY CHECK, FRAME 80, STRINGER 26R HAD CORRODED SKIN DOUBLER. PERFORMED CENTER FUSELAGE II, INTERNAL SKIN DOUBLER AT FRAME 80 AND STRINGER 26R -…
- 23 Sep 2026
Panel, missing
NR 1 PYLON PANEL MISSING UPON ARRIVAL. INSTALLED PYLON SIDE FAIRING PANEL
- 28 Jun 2025
None, no discrepancy
BIRDSTRIKE ON TAKEOFF. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. PERFORMED BIRD STRIKE INSPECTION, NO DEFECTS NOTED.
- 11 Nov 2022
Light, burned out
ROW 1-3 AIRCRAFT RIGHT PHOTOLUMINESCENT LIGHT BURNED OUT. R&R ROW 1-3 AIRCRAFT RIGHT PHOTOLUMINESCENT STRIP.
- 11 Aug 2022
Fmc, unserviceable
AFTER SWITCHING TO VNAV, WE RECEIVED VERY STRANGE COMMANDS FROM THE AUTO THROTTLE AND THE FLIGHT DIRECTOR. THE AUTOTHROTTLES WOULDN'T INCREASE TO FULL POWER…
- 28 Jun 2022
Doubler, corroded
6 EA. CORRODED FASTENERS AT FR 87 - FR 88 STRG 27 - 28 IN THE WASTE BOX DOUBLER. REMOVED AND REPLACED WASTE DOUBLER PN: 170-66931-001 REF EMB SRM 51-40-08,…
- 26 Jun 2022
Stringer, corroded
CORROSION ON STRINGER 21R BETWEEN FR 86-87 AS MARKED. CUT SECTION OF CORRODED OF STRINGER 21R AND REPLACED SECTION AND INSTALL FILLER AND SPLICES REF EMB…
- 25 Jun 2022
Shear Tie, corroded
CF III HAS CORRODED SHEAR CLIP FORWARD OF WASTE SERVICE BOX AT FR 88 BETWEEN STGR 27R AND STGR 28R AS MARKED. REMOVED AND REPLACED SHEAR CLIP PN:…
- 24 Jun 2022
Stringer, corroded
CORROSION ON STRINGER 20R: ONE AREA BETWEEN FR 85-87 AND TWO RIVETS BETWEEN FR 86-87 AS MARKED. CUT SECTION OF CORRODED OF STRINGER 20R AND REPLACED SECTION…
- 18 Jun 2022
Downlock, leaking
HYDRAULIC 2 LOW PRESSURE AFTER GEAR EXTENSION. 0 INDICATIONS ON PRESSURE AND QUANTITY ON HYDRAULIC PAGE. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. RH MLG…
- 4 Mar 2022
Skin, dented
LOWER SKIN DAMAGED BETWEEN FR 29-30 AND STR 28L-28R. PERFORMED REPAIR ,CUTOUT DAMAGE INSTALLED FILLER,DOUBLER,TRIPLER ALSO REPLACED FRAME 30 AT DAMAGED AREA…
- 29 Nov 2019
Angle, cracked
***AIRCRAFT IS IN HEAVY CHECK***CRACK FOUND ON ANGLE OF FLIGHT DECK FLOOR STRUCTURE AT FR 12, BL 0. REPLACED ANGLE IAW SRM 51-41-01. ***AIRCRAFT REMAINS IN…
- 26 Nov 2019
Floor Support, corroded
***AIRCRAFT IS IN HEAVY MAINTENANCE***FLOOR SUPPORT CORRODED AT FR 88, RBL 40. REPLACED FLOOR SUPPORT IAW SRM 51-43-03.***AIRCRAFT REMAINS IN HEAVY CHECK***
- 26 Nov 2019
Seat Track, corroded
***AIRCRAFT IS IN HEAVY MAINTENANCE***SEAT TRACK CORRODED AT FR 19-20, LBL 10. REPLACED SEAT TRACK IAW SRM 51-43-03.***AIRCRAFT REMAINS IN HEAVY CHECK***
- 25 Nov 2019
Skin, cracked
LT WING FIXED L.E. SLAT TRACK 5 CUT OUT CRACKED. REMOVED CRACK IAW SRM 51-10-03 AND FOUND WITHIN LIMITS PER SRM 57-49-01. NO FURTHER ACTION REQUIRED
- 18 Jun 2019
Power Supply, inoperative
CEILING EMERGENCY LIGHT OUT. R&R THE NR 3 POWER UNIT OF THE EMERGENCY LIGHTS SYSTEM IN REF TO AMM 33-50-01.
- 25 May 2019
Connector, unsecure
OVERHEAD EMERGENCY LIGHTS ROW 16 ARE INOP. RESECURED CONNECTOR ON EMERGENCY LIGHT ROW 16 AND OPS CHECK GOOD REF AMM 33-50-00.
- 2 Jul 2018
Power Unit, inoperative
R1 DOOR EMERGENCY LIGHT INOP. R&R EMERGENCY LIGHT POWER UNIT ABOVE R1 DOOR IAW AMM 33-50-01.
- 30 Nov 2017
Floorbeam, corroded
RT INBD FLOORBEAM BETWEEN FR 12 AND FR20 HAS CORROSION AS MARKED. REMOVED AND REPLACED RT INBOARD SEAT TRACK FR 12-20 REF SRM 51-21-00 AND 51-40-08.
- 29 Nov 2017
Gusset, corroded
REMOVED AND REPLACED FLOOR GUSSET FR.90 RBL 11 REF SRM 51-41-01. PN 170-60257-001. AIRCRAFT REMAINS IN HEAVY CHECK BNA.
- 29 Nov 2017
Doubler, corroded
CORROSION BETWEEN FR 12 AND FR 14 AT RT FLOOR STRUCTURE UNDER RT FWD GALLEY. REMOVED AND REPLACED FLOOR DOUBLER AT FR 12 AND FR 14 AT RT FLOOR STRUCTURE UNDER…
- 29 Nov 2017
Shear Panel, corroded
CORROSION AS MARKED, CENTER SHEAR PANEL FR 87-88. REMOVED AND REPLACED CENTER SHEAR PANEL REF SRM 51-42-01. ACFT REMAINS IN HEAVY CHECK BNA.
- 29 Nov 2017
Floorbeam, corroded
CORROSION AS MARKED, RT FLOORBEAM FR 86-87 REMOVED AND INSTALLED NEW RT FLOORBEAM REF SRM 51-41-01, 51-42-01, 51-43-03. ACFT REMAINS IN HEAVY CHECK BNA
- 29 Nov 2017
Door Sill, corroded
CORROSION LT FLOOR SILL FR 87-88. BLENDED CORROSION ON LT FLOOR SILL FR 87-88 COMPLIED WITH PERMANENT REPAIR PER ETD2017-170-105121. ACFT REMAINS IN HEAVY…
- 29 Nov 2017
Floorbeam, corroded
LT FLOORBEAM CORRODED AS MARKED FR 85-87. REMOVED AND INSTALLED NEW LT FLOORBEAM BETWEEN FRAMES 85-87 REF SRM 51-41-01, 51-43-03. ACFT REMAINS IN HEAVY CHECK…
- 29 Nov 2017
Upper Sheet, corroded
CORROSION ON LT UPPER SHEET BETWEEN FR 85 AND 86. REMOVED AND INSTALLED NEW LT UPPER SHEET BETWEEN FRAMES 85 AND 86 REF SRM 51-41-01, 51-43-03 PN…
- 9 Jun 2017
Battery, inoperative
COCKPIT EMERGENCY LIGHT DOES NOT COME ON. R & R EMERGENCY BATTERY IN FWD GALLEY ABOVE R1 DOOR IAW AMM 33-50-01. OPS CHECKED GOOD.
- 12 Oct 2016
Light, malfunctioned
CREW RECEIVED AN EMERGENCY LIGHT BATTERY FAULT AND THE FORWARD HALF OF EMERGENCY LIGHTS WERE INOPERATIVE. MAINTENANCE RESET AIRCRAFT POWER IAW AMM AND OPS…
- 4 Sep 2016
Handle, out of alignment
CREW REPORTED THAT THE L2 DOOR HANDLE WAS NOT ALIGNING BUT SHOWED GREEN ON EICAS. MAINTENANCE PERFORMED VISUAL INSPECTION AND CYCLED DOOR IAW AMM AND OPS…
- 6 Apr 2016
Light, damaged
MAINTENANCE REPORTED THAT THE LT EMERGENCY LIGHT IN FIRST CLASS WERE DAMAGED. MAINTENANCE R & R EMERGENCY LIGHTS IAW AMM AND OPS CHECKED GOOD.
- 5 Aug 2015
Warning Message, false activation
THE CREW REPORTED THAT THEY RECEIVED A FUEL FEED 1 FAULT ADVISORY MESSAGE DURING CRUISE FLIGHT. THE CREW FOLLOWED THE QRH AND RECEIVED AN ENGINE FUEL LOW…
- 29 Mar 2015
Flashlight, inoperative
MAINTENANCE REPORTED THAT THE AFT F/A FLASHLIGHT WAS INOPERATIVE. MAINTENANCE R & R AFT F/A FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.
- 24 Jan 2014
Indicator, out of position
CREW REPORTED THAT THE L1 DOOR SLIDE DISARM INDICATOR IS NOT FULLY GREEN WHEN DISARMED. MAINTENANCE ADJUSTED SLIDE INDICATION IAW AMM AND OPS CHECKED GOOD.…
- 19 Nov 2013
Indicator, out of adjust
CREW REPORTED THAT THE MAIN CABIN DOOR DOES NOT FULLY SHOW A DISARMED INDICATION. MAINTENANCE ADJUSTED ARM-DISARM INDICATOR IAW AMM. DOOR OPS CHECKED GOOD AND…
- 20 Sep 2013
Slide, partial deploy
L1 DOOR WAS OPENED BEFORE F/A COULD DISARM DOOR, CAUSING THE PARTIAL DEPLOYMENT OF THE SLIDE. ACFT FERRIED, WHERE THE SLIDE WAS R & R IAW AMM AND OPS CHECKED…
- 19 Aug 2013
Diaphragm, damaged
L1 DOOR ASSIST BOTTLE LEAKING. MX REPLACED DIAPHRAM AND SHEAR PIN IAW AMM AND OPS CHECKED GOOD.