- 5 Jun 2003
Skin, cracked
FUSELAGE SKIN CRACKED AT AFT SIDE OF E&E EQUIPMENT FAN OUTLET. REPAIRED PER SB 737-53-1117.
- 5 May 2003
Light, inoperative
FLOOR PATH LIGHTING INOP ROWS 18-26. REPLACED LAST SECTION OF FLOOR PATH LIGHT STRIP.
- 3 May 2003
Wire, damaged
EMERGENCY LIGHTING INOP. ROW 18 AFT. REPAIRED WIRING IAW SP CHPT.20. TEST OK
- 14 Apr 2003
Light, inoperative
ROW 1 THRU 5 EMERGENCY PATH LIGHTS INOP. REPLACED LAMP CONNECTING STRIP PER MM 33-50-00. OPS CHECK OK.
- 3 Apr 2003
Light, inoperative
EMERGENCY FLOOR LIGHTING INOPERATIVE, ROW 20 AFT. REPLACED ROW 17-29 LIGHT STRIP IAW MM 25-60-01. OPS CHECK OK.
- 29 Mar 2003
Light, inoperative
EMERGENCY LIGHTS INOPERATIVE, 20 AFT. CLEANED STRIP CONNECTIONS AT AFT END FROM MOISTURE/WATER. LIGHTS CHECK, OK, IAW MM 33-50-00.
- 21 Mar 2003
Light, inoperative
ROW 1-4 LOW LEVEL EMERGENCY LIGHTS INOPERATIVE. REMOVED & REPLACED EMERGENCY FLOOR PATH STRIP ELEMENT IAW MM 33-50-00. TESTS OK.
- 9 Mar 2003
Light, contaminated
SECTION 1 & 2 EMERGENCY PATH LIGHTING INOP. REPLACED WET SEGMENTS OF LIGHT STRIP. OPS CHK OK PER MM 33-29-00
- 21 Dec 2002
Computer, failed
FMC COMPUTER POPS CIRCUIT BREAKER. REMOVED AND REPLACED FMC COMPUTER. BITE CHECK. OK IAW MM.
- 5 Oct 2002
Control Unit, malfunctioned
CHANNEL B ON AUTO PILOT INOPERATIVE. AUTO THROTTLES RETARD TO IDLE, WOULD NOT DISPLAY MACH SPEED ON MCP. PERFORMED A/P LAND VERIFY BITE CHECK THROUGH FMC. NO…
- 12 Sep 2002
Inverter
Emergency floor path lighting inop at aprox. sta. 500C. Trouble shot & found inverter bad. R&R inverter IAW WDM 33-51-41, Ops chk good.
- 22 Jun 2002
Engine
At rotation had a loud engine vibration on Left engine. Inspected eng. intake, exhaust; opened cowlings & inspected; close cowlings; BITE AVM per MM77-31-00.…
- 21 Jun 2002
Skin, damaged
Fuselage skin damaged by belt loader sta 767 to sta 772 between str27Lt. and str27Rt.
- 21 Jun 2002
Skin, damaged
Fuselage skin damaged by belt loader sta 797 to sta 818 at str27Lt.
- 21 Jun 2002
Skin, damaged
Fuselage skin damaged by belt loader at sta 789 to sta 799 between str26Rt. and str27Rt.
- 18 Jun 2002
Light
Emergency floor path will not illuminate from row 6 to row 12. Repaired wiring floor emerg. path and acc. test IAW MM 33-53-00. Test OK
- 2 Jun 2002
Slide, unserviceable
L1 DOOR SLIDE PRESSURE LOW. REMOVED AND REPLACED SLIDE.