N37078
1941 Luscombe 8C FAA →
earlier registrations
3 past records
owner withheld at the FAA
- 1973
- 1941
service difficulty reports
43 reports
- 16 May 2000
Battery, discharged
THE L-3 DOOR AND R-1 DOOR ESCAPE SLIDE LIGHTS TESTED DIM. THE SLIDE LIGHT BATTERY WAS REPLACED AT EACH DOOR AND OPERATION CHECKED GOOD IAW MM 25-61-01.
- 15 Apr 2000
Galley Track, corroded
INSPECTION FOUND GALLEY SUPPORT CORRODED AT STA 1910, LBL 55. THE SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 51-31-01.
- 15 Apr 2000
Galley Track, corroded
INSPECTION FOUND GALLEY SUPPORT CORRODED AT STA 1020, LBL 27. THE SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 51-31-01.
- 15 Apr 2000
Galley Track, corroded
INSPECTION FOUND GALLEY SUPPORT CORRODED AT STA 1887 - 2007, RBL 27 AND LBL 27. THE SUPPORTS WERE REMOVED AND REPLACED IAW SRM 51-31-01.
- 15 Apr 2000
Galley Track, corroded
INSPECTION FOUND GALLEY SUPPORTS CORRODED AT STA 1887 - 1900, BL 0 AND RBL 55 AND AT STA 1871 - 1887, RBL 33. THE SUPPORTS WERE REMOVED AND REPLACED IAW SRM…
- 13 Apr 2000
Floorbeam, corroded
INSPECTION FOUND FLOORBEAMS CORRODED AT STA 1887, BETWEEN RBL 25 - 30, RBL 35 -55, AND RBL 65 - 100. THE FLOORBEAMS WERE REMOVED AND NEW FLOORBEAMS WERE…
- 6 Dec 1999
Gear Handle, binding
WHEN THE LANDING GEAR WAS EXTENDED ON APPROACH TO EWR, NO GREEN GEAR SAFE LIGHTS ILLUMINATED. THE GEAR WAS CYCLED THREE TIMES BEFORE RECEIVING GREEN DOWN AND…
- 6 May 1999
Frame, corroded
CENTER CARGO BAY DOOR FRAME LOWER SECTION CORRODED. REPAIRED PER SRM 53-50-00.
- 5 May 1999
Skin, cracked
NR 1 LEFT SLAT OUTER SKIN CRACKED. REPAIRED PER SRM 57-10-00, NR 6 LEADING EDGE RIB FOUND CRACKED. NEW RIBS FABRICATED PER DWG NRB6223 OP 3 AND ARB1583-405 OP…
- 3 May 1999
Angle, cracked
MAN - SUSPECT CRACK RIGHT DRAG ANGLE REPAIR PLATE AT LOWER END OF FIRST BANJO FITTING. AFTER NDT INSPECTION, CRACK CONFIRMED (1 INCH). CRACK STOP-DRILLED PER…
- 3 May 1999
Angle, cracked
MAN - RIGHT HAND DRAG ANGLE AT LOWER END OF THIRD BANJO FITTING. SUBMITTER SUSPECTED CRACK. AFTER NDT, CRACK CONFIRMED (1 INCH). STOP-DRILLED CRACK PER SRM…
- 3 May 1999
Angle, cracked
MAN - SUSPECT CRACK LT DRAG ANGLE AT LOWER END OF THIRD BANJO FITTING. AFTER NDT INSPECTION, CRACK CONFIRMED (1 INCH). CRACK STOP-DRILLED PER SRM 55-20-00.…
- 22 Jul 1998
Battery Pack, discharged
THE EMERGENCY TRACK LIGHTING FAILED TEST. THE MID GALLEY BATTERY PACK WAS REMOVED AND REPLACED AND OPERATION CHECKED GOOD.
- 26 Dec 1997
Actuator, damaged
A LOUD CLUNK WAS HEARD IN COCKPIT AREA ON GEAR RETRACTION, FOLLOWED BY UNSAFE NOSE GEAR INDICATION. FUEL WAS DUMPED AND THE AIRCRAFT WAS RETURNED TO LGW WHERE…
- 4 Jun 1997
Fuel Filter, contaminated
NR 3 ENG FLAMED OUT WHILE DESCENDING THRU FL 220 EN ROUTE. ENG FAILURE WAS ACCOMPANIED BY ILLUMINATION OF BOTH NR 3 GEN OFF LIGHT AND THE NR 3 ENG LOW OIL…
- 21 Jan 1997
Splice, corroded
INSPECTION FOUND STRINGER SPLICE CORRODED AT STA 1135 TO 1137. THE SPLICE WAS REMOVED AND A NEW SPLICE WAS INSTALLED IAW SRM 51-31-01.
- 19 Jan 1997
Splice, corroded
INSPECTION FOUND STRINGER 27R SPLICE CORRODED AT STA 1120. THE SPLICE WAS REMOVED AND REPLACED IAW SRM 51-33-01 AND 51-10-00.
- 16 Jan 1997
Splice, cracked
INSPECTION FOUND A .5 INCH CRACK IN STRINGER SPLICE BETWEEN STA 1521 AND 1541, STRINGER 1L. THE SPLICE WAS REMOVED AND REPLACED IAW SRM 51-31-01.
- 11 Jan 1997
Angle, corroded
INSPECTION FOUND T-ANGLE CORRODED AT STA 464, X= -4 INSIDE OF NLG WHEEL WELL FORWARD BULKHEAD. THE T-ANGLE WAS FABRICATED AND INSTALLED IAW SRM 53-40-00,…
- 8 Jan 1997
Mount, cracked
INSPECTION FOUND A 3 INCH CRACK IN FILLET FAIRING MOUNT AT STA 1099, LONGERON 36. THE MOUNT WAS REMOVED AND REPLACED IAW SRM 51-31-01.
- 28 Dec 1996
Support, corroded
INSPECTION FOUND CORROSION ON FLOOR SUPPORT AROUND GALLEY FLOOR SPACER AT STA 497, X+22. THE FLOOR SUPPORT WAS REMOVED AND A NEW FLOOR SUPPORT WAS FABRICATED…
- 28 Dec 1996
Support, cracked
INSPECTION FOUND FLOORBOARD SUPPORT CRACKED IN SIX PLACES AT STA 1887, X = 38-57. THE CRACKS WERE 1 OR LESS IN LENGTH. THE FLOOR SUPPORT WAS REMOVED AND A NEW…
- 21 Dec 1996
Panel, gouged
INSPECTION FOUND A GOUGE AT CORNER EDGE OF VERTICAL STABILIZER ACCESS PANEL NR 373EL. A DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 55-00-01, FIGURE 3 AND…
- 17 Dec 1996
Panel, cracked
INSPECTION FOUND A 1 INCH CRACK AT CUTOUT OF NR 1 ENGINE PYLON PANEL NR 437DR. THE CRACK WAS STOP DRILLED AND A DOUBLER WAS FABRICATED AND INSTALLED IAW SRM…
- 11 Dec 1996
Longeron, corroded
INSPECTION FOUND LONGERON 4L CORRODED BETWEEN BS 1119 TO 1139. THE CORRODED SPLICE WAS REMOVED AND A NEW ONE WAS FABRICATED AND INSTALLED IAW SRM 53-10-00…
- 11 Dec 1996
Angle, cracked
INSPECTION FOUND A 1.5 INCH CRACK ON SUPPORT ANGLE UNDER BODY FILLET JUST ABOVE WING AT FS 1341R. THE CRACKED AREA WAS REMOVED AND A NEW PART WAS FABRICATED…
- 10 Dec 1996
Support, corroded
INSPECTION FOUND CORROSION ON LAV TIE DOWN FLOOR SUPPORT AT STA 2004, X-55. THE FLOOR SUPPORT WAS REPAIRED IAW SRM 53-70-01, FIGURE 13.
- 10 Dec 1996
Support, corroded
INSPECTION FOUND LAV TIE DOWN FLOOR SUPPORT CORRODED AT STA 1915 AND 2004, LBL X+55. THE FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 53-70-00.
- 10 Dec 1996
Support, cracked
INSPECTION FOUND TWO CRACKS APPROXIMATELY .5 INCH LONG IN FLOORBOARD SUPPORT AT STA 1986, X + 1 TO 16. A NEW SUPPORT WAS FABRICATED AND INSTALLED IAW SRM…
- 10 Dec 1996
Support, cracked
INSPECTION FOUND A .35 INCH CRACK IN FLOORBOARD SUPPORT AT STA 1943, X-1 TO 16. A NEW SUPPORT WAS FABRICATED AND INSTALLED IAW SRM 51-21-01 AND 51-31-01.
- 10 Dec 1996
Support, cracked
INSPECTION FOUND THREE CRACKS UP TO .30 INCH LONG IN FLOORBOARD SUPPORT AT STA 1943, X - 11 TO 16. A NEW FLOOR SUPPORT WAS FABRICATED AND INSTALLED IAW SRM…
- 10 Dec 1996
Support, cracked
INSPECTION FOUND A .20 INCH CRACK IN FLOORBOARD SUPPORT AT STA 1921, X + 1 TO 16. TWO CRACKS UP TO .30 INCH LONG WERE FOUND IN FLOORBOARD SUPPORT AT STA 1921,…
- 10 Dec 1996
Support, cracked
INSPECTION FOUND TWO CRACKS UP TO .35 LONG IN FLOORBOARD SUPPORT AT STA 1965, X -1 TO 16. ALSO, TWO CRACKS UP TO .20 INCH LONG WERE FOUND IN FLOORBOARD…
- 9 Dec 1996
Casting, corroded
INSPECTION FOUND STRINGER 24R CASTING CORRODED BETWEEN STA 1321 AND 1341. THE CASTING WAS REMOVED AND REPLACED IAW SRM 51-33-01.
- 7 Dec 1996
Support, cracked
INSPECTION FOUND FLOORBOARD SUPPORT CRACKED IN THREE PLACES AT STA 420, X-13 TO X-22. THE CRACKS WERE .125 INCH LONG. THE FLOOR SUPPORT WAS REMOVED, A NEW…
- 6 Dec 1996
Bulkhead Angle, cracked
INSPECTION FOUND A 1 INCH CRACK IN FLOOR SUPPORT L-ANGLE AT CENTER CARGO FORWARD BULKHEAD FS 1521, RBL 19. THE CRACK WAS STOP DRILLED, AN L-ANGLE AND DOUBLERS…
- 5 Dec 1996
Skin, rippled
INSPECTION FOUND RIPPLING ONE FOOT IN DIAMETER IN RT WING NR 1 SLAT AT INBOARD END. THE RIPPLED AREA WAS CUT OUT, A SKIN INSERT, SPLICE STRAPS, DOUBLERS AND…
- 4 Dec 1996
Skin, dented
INSPECTION FOUND A 5 INCH DIAMETER BY 0.060 DEEP DENT IN OUTBOARD RT WING NR 3 SLAT. A SKIN AND DOUBLER REPAIR WAS INSTALLED IAW SRM 57-10-00, FIGURE 11.
- 3 Dec 1996
Wing Tip, creased
INSPECTION FOUND A 3L BY .5W BY 0.080D CREASE IN RT WING TIP AT XW 988, BETWEEN TIP LEADING EDGE AND TRAILING EDGE. A FILLER AND DOUBLER REPAIR WAS FABRICATED…
- 30 Nov 1996
Panel, dented
INSPECTION FOUND FOUR DENTS ON UPPER SURFACE OF RT WING TRAILING EDGE PANEL 641HB. A DOUBLER AND FOUR FILLERS WERE FABRICATED AND INSTALLED IAW SRM 51-71-00,…
- 27 Nov 1996
Angle, corroded
INSPECTION FOUND L-ANGLE CORRODED AT FORWARD ADF LOOP ANTENNA. AN L-ANGLE WAS FABRICATED AND INSTALLED WITH NUT PLATES IAW SRM 53-00-01, FIGURE 2, SHEET 2,…
- 27 Nov 1996
Support, corroded
INSPECTION FOUND FLOOR SUPPORT CORRODED AT STA 879 AND 899, Y= -44. CHANNEL FLOOR SUPPORT ANGLES AND BOSSES WERE FABRICATED AND INSTALLED IAW SRM 51-31-01,…
- 6 Nov 1996
Frame, corroded
INSPECTION FOUND FORWARD SIDE OF FRAME CORRODED IN AFT CARGO BILGE AREA AT STA 1781 FROM LONGERON 50L TO 50R. THE CORRODED SECTION WAS CUT OUT, AN L-ANGLE…