N357AA
Anduril Industries INC ROADRUNNER FAA →
registration
earlier registrations
1 past record
- 1988
service difficulty reports
104 reports
- 2 May 2015
Light, intermittent
LIGHT ASSEMBLY WORKS INTIMATELY. R & R LIGHT ASSEMBLY IAW AMM 33-51-04.
- 20 Aug 2014
Frame, cracked
FOUND SMALL CRACK ON THE RT ENG PYLON NAC STATION 285 INBD FRAME. R & R RT ENG PYLON INBD FRAME AT NAC STATION 285 IAW AARD 51-00-005-1.
- 24 Jul 2014
Indication Sys, malfunctioned
INFLIGHT CREW REPORTED TWO HOURS 30 MINS INTO FLIGHT LT WING IS LIGHT 1000 LBS, FUEL SCORE IS DOWN 2000 LBS. LT ENG IS BURNING 200 LBS PER HR LESS THAN RT ENG…
- 23 May 2014
Light, inoperative
RED EMERGENCY LIGHT AT SEAT 20H INOPERATIVE. REPLACED LAMP FOR RED EMERGENCY LIGHT AT SEAT 20H. OPERATIONS CHECKED NORMAL.
- 23 May 2014
Light, inoperative
LEFT AFT INTERIOR, OVERWING LOWER EXIT SIGN INOPERATIVE. REPLACED LAMP FOR LT AFT INTERIOR, OVERWING LOWER EXIT SIGN. OPERATIONS CHECKED NORMAL.
- 10 Mar 2014
Pump, inoperative
TUL DURING FCF RT ENG WAS SHUT DOWN & WOULD NOT RESTART DURING FLIGHT. RT ENG FUEL VLV IS ILLUMINATED STEADY WITH FUEL SWITCH IN THE RUN POSITION. ALSO FUEL…
- 6 Mar 2014
Skin Panel, damaged
SKIN PANEL FROM STATIONS 420 TO 445 & STRINGERS 33 TO 35 LT DAMAGED. INSTALLED DOUBLER IAW EA B767-53-033867.
- 3 Mar 2014
Skin, dented
SKIN AT STATION 1522 & STRINGERS 27 TO 29 RT DENTED. REMOVED DAMAGE AREA & INSTALLED DOUBLER IAW SRM 53-00-01 & EA B767-53-033833.
- 25 Feb 2014
Skin, dented
DENT IN FUSELAGE FROM STATIONS 1509 TO 1603 AT STRINGER 29 RT. INSTALLED EXTERNAL DOUBLER IAW SRM 53-00-01-2R-1.
- 12 Feb 2014
Light, inoperative
RT NR 4 DOOR EXTERNAL LIGHT DID NOT ILLUMINATE, REPLACED LAMP FOR RT NR 4 DOOR EXTERNAL EMERGENCY LIGHT. OPERATIONS CHECKED NORMAL.
- 16 Nov 2013
Connector, loose
SEAT 28H EMERGENCY LIGHT INOPERATIVE. RECONNECTED LOOSE CONNECTOR, OPERATIONS CHECKED NORMAL.
- 4 Nov 2013
Light, inoperative
LT NR 1 EMERGENCY EXIT SIGN HANDLE ILLUMINATION LIGHT INOPERATIVE. REPLACED LAMP. OPERATIONS CHECKED NORMAL.
- 4 Nov 2013
Light, inoperative
ESCAPE PATH MARKER MOUNTED TO FS3 LAVATORY LOWER WALL INOPERATIVE. REPLACED LAMP FOR ESCAPE PATH MARKER MOUNTED TO FS3 LAVATORY LOWER WALL. OPERATIONS CHECKED…
- 4 Nov 2013
Light, inoperative
CEILING MOUNTED ESCAPE PATH ILLUMINATION LIGHT BETWEEN SEATS 37BC INOPERATIVE. REPLACED LAMP FOR CEILING MOUNTED ESCAPE PATH ILLUMINATION LIGHT BETWEEN SEAT…
- 4 Nov 2013
Light, inoperative
RT NR 2 EMERGENCY EXIT SIGN HANDLE ILLUMINATION LIGHT INOPERATIVE. REPLACED LAMP FOR RT NR 2 EMERGENCY EXIT SIGN HANDLE ILLUMINATION LIGHT. OPERATIONS CHECKED…
- 4 Nov 2013
Light, inoperative
LT NR 2 EMERGENCY EXIT SIGN HANDLE ILLUMINATION LIGHT INOPERATIVE. REPLACED LAMP FOR LT NR 2 EMERGENCY EXIT SIGN HANDLE ILLUMINATION LIGHT. OPERATIONS CHECKED…
- 4 Nov 2013
Light, inoperative
INTERIOR LT OVERWING AFT DOOR LOWER EXIT MARKER INOPERATIVE. REPLACED LAMP FOR INTERIOR LT OVERWING AFT DOOR LOWER EXIT MARKER. OPERATIONS CHECKED NORMAL.
- 4 Nov 2013
Light, inoperative
INTERIOR RT OVERWING AFT DOOR LOWER EXIT MARKER INOPERATIVE. REPLACED LAMP FOR INTERIOR RT OVERWING AFT DOOR LOWER EXIT MARKER. OPERATIONS CHECKED NORMAL.
- 9 Sep 2013
Splice, damaged
BUTT SPLICE AT STATION 654 DAMAGED. REPLACED BUTT SPLICE.
- 6 Sep 2013
Frame, damaged
FRAME & ASSOCIATED STRUCTURE AT STATION 632 SUSTAINING HEAT DAMAGE FROM CARGO FIRE. REPLACED FRAME & ASSOCIATED STRUCTURE IAW SRM 51-40-02-0G, AARD 51-00-05-1…
- 6 Sep 2013
Frame Splice, damaged
DAMAGED FRAME SPLICE AT STATION 632. REPLACED FRAME SPLICE.
- 6 Sep 2013
Stringer, damaged
DAMAGED STRINGER 37 LT FROM STATIONS 626 TO 654. REPLACED STRINGER.
- 6 Sep 2013
Skin, damaged
FIRE DAMAGE TO AIRCRAFT SKIN FROM STATIONS 632 TO 654 & STRINGERS 35 LT & 36 RT. CUT OUT AREA & INSTALLED DOUBLER & TRIPLER.
- 6 Sep 2013
Stringer, damaged
STRINGER 36 LT FROM STATIONS 626 TO 654 DAMAGED. REPLACED STRINGER.
- 6 Sep 2013
Floor Panel, corroded
CORRODED FLOOR PANEL AT STATION 481. REPLACED PANEL.
- 6 Sep 2013
Stringer, damaged
STRINGER 37 RT FROM STATIONS 626 TO 654 DAMAGED. REPLACED STRINGER.
- 6 Sep 2013
Stringer, damaged
STRINGER 38 RT FROM STATIONS 626 TO 654 DAMAGED. REPLACED STRINGER.
- 6 Sep 2013
Stringer Splice, damaged
STRINGER SPLICE AT STATION 654 & STRINGER 38 LT DAMAGED. REPLACED STRINGER SPLICE.
- 6 Sep 2013
Stringer Splice, damaged
STRINGER SPLICE DAMAGED AT STATION 654 & STRINGER 39 LT. REPLACED STRINGER SPLICE.
- 6 Sep 2013
Stringer, damaged
STRINGER DAMAGED AT STATION 654 & STRINGER 39 RT. REPLACED STRINGER.
- 6 Sep 2013
Stringer, damaged
STRINGER DAMAGED AT STATION 626 TO 654 & STRINGER 35 LT. STRINGER REPLACED.
- 6 Sep 2013
Tear Strap, damaged
TEAR STRAP AT STATION 632 & STRINGERS 36 LT & RT DAMAGED. REPLACED TEAR STRAP.
- 6 Sep 2013
Web, damaged
WEB ASSEMBLY AT STATION DAMAGED. REPLACED WEB ASSEMBLY.
- 5 Sep 2013
Frame, damaged
PDU MOUNT FRAME IN FWD CARGO DAMAGED FROM CARGO FIRE. REPLACED PDU MOUNT FRAME IAW AARD 51-00-05 REPAIR 1 & EA B767-53-031331.
- 5 Sep 2013
Frame, damaged
PDU MOUNT FRAME IN FWD CARGO DAMAGED FROM CARGO FIRE. REPLACED PDU MOUNT FRAME IAW AARD 51-00-05 REPAIR 1 & EA B767-53-031331.
- 5 Sep 2013
Floor Support, damaged
FLOOR SUPPORT WEB & EXTRUSION DAMAGED FROM CARGO FIRE. REPLACED FLOOR SUPPORT WEB & EXTRUSION IAW SRM 51-70-12 & SRM 51-70-13.
- 5 Sep 2013
Pan, damaged
PDU PAN ASSEMBLY DAMAGED DUE TO CARGO FIRE. REPLACED PDU PAN ASSEMBLY SUPPORT STRUCTURE IAW AARD 51-00-05-1 & EA B767-53-031278 & DRAWING 451T2451.
- 27 Aug 2013
Intercostal, corroded
INTERCOSTAL FROM STATIONS 610 TO 632 CORRODED. REPLACED INTERCOSTAL.
- 26 Aug 2013
Floor Panel, corroded
CARGO FLOOR PANEL AT STATION 481.6 CORRODED. REPLACED FLOOR PANEL.
- 26 Aug 2013
Stringer, damaged
FIRE RELATED DAMAGE TO STRINGER 36 RT BETWEEN STATIONS 600 & 654. ACCOMPLISHED DOUBLER REPAIR IAW SRM 53-00-03 & EA B767-53-030963.
- 8 Aug 2012
Skin, gouged
GOUGE IN FUSELAGE UPPER CROWN SKIN, STATION 886, BETWEEN STRINGERS 4 AND 5 RIGHT. CUT OUT DAMAGE AND INSTALLED DOUBLER PER SRM 53-00-01-2R REPAIR 1 AND EA…
- 8 Aug 2012
Skin, gouged
TWO GOUGES IN FUSELAGE UPPER CROWN SKIN, STATIONS 855 TO 861, JUST BELOW STRINGER 5 RIGHT. CUT OUT DAMAGE AND INSTALLED DOUBLER PER SRM 53-00-01-2R REPAIR 1…
- 8 Aug 2012
Skin, gouged
GOUGES IN FUSELAGE UPPER CROWN SKIN, STATION 835, BETWEEN STRINGERS 3 AND 4 RIGHT. CUT OUT DAMAGE AND INSTALLED DOUBLER PER SRM 53-00-01-2R REPAIR 1 AND EA…
- 7 Aug 2012
Skin, corroded
CORROSION ON LAP SEAM, STATION 1241 AT STRINGER 36 LEFT. CUT OUT DAMAGE AND INSTALLED EXTERNAL DOUBLER PER SRM 53-00-01-2R.
- 7 Aug 2012
Tear Strap, damaged
TEAR STRAP AT STATION 1241 BELOW STRINGER 36 LEFT DAMAGED. SPLICE REPAIR OF TEAR STRAP.
- 7 Aug 2012
Skin, corroded
SKIN CORROSION AT STATION 434 BETWEEN STRINGERS 33 TO 35 LEFT. INSTALLED EXTERNAL DOUBLER PER EA B767-53-015392.
- 6 Aug 2012
Web, cracked
LEFT PYLON UPPER TORQUE BOX FEEDER CABLE THRU HOLE CRACKED. INSTALLED DOUBLER REPAIR PER AARD 54-52-01-1.
- 4 Aug 2012
Skin, debonded
LEFT OUTBOARD FLAP LOWER SURFACE DISBONDED. ACCOMPLISHED BONDED REPAIR PER SRM 57-53-01.
- 3 Aug 2012
Skin, damaged
HAIL DAMAGE ON RIGHT OUTBOARD FLAP UPPER SURFACE. ACCOMPLISHED BONDED REPAIR PER SRM 57-53-01.
- 2 Aug 2012
Skin, damaged
HAIL DENT TO LEFT OUTBOARD UPPER SURFACE. ACCOMPLISHED BONDED REPAIR PER SRM 57-53-01.
- 7 Jul 2012
Fire Loop, faulty
LAX - INFLIGHT DFW-OGG. CREW REPORTED A FIRE LOOP WARNING DURING CRUISE. EMERGENCY DECLARED FLIGHT DIVERTED LAX LANDED WITHOUT INCIDENT. AIRCRACFT REMOVED…
- 25 Jan 2012
Battery Pack, discharged
SEAT MOUNTED EMERGENCY LIGHTS FROM ROWS 20AB TO 24AB INOPERATIVE. REPLACED BATTERY PACK.
- 1 Oct 2011
Wire, loose
EMERGENCY EXIT LIGHT AT 28DEF FAILED TO ILLUMINATE. RECONNECTED LOOSE WIRE AT LIGHT ASSY, OPS CHECK NORMAL.
- 6 Sep 2011
Wire, broken
SEAT MOUNTED EMERGENCY LIGHT AT 17 H/J INOPERATIVE. REPAIRED BROKEN WIRE AT 17 H/J. OPS CHECK NORMAL.
- 24 Jul 2011
Pump, failed
DFW - CREW REPORTED CENTER SYSTEM HYDRAULIC AIR DRIVEN PUMP FAILED INFLIGHT. NO FLUID LOSS REPORTED. EMERGENCY DECLARED FLIGHT RETURNED DFW LANDED WITHOUT…
- 8 May 2011
Apu, failed
DURING BOARDING THE AUXILIARY POWER UNIT FAILED CAUSING THE CABIN AND COCKPIT TO FILL WITH SMOKE. PASSENGERS WERE EVACUATED WITH NO INJURIES REPORTED.…
- 1 Apr 2011
Sensor, inoperative
HNL - CREW REPORTED RIGHT ENGINE BLEED AIR OVERHEAT MESSAGE ON EICAS. EMERGENCY DECLARED FLIGHT RETURNED HNL LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM…
- 11 Mar 2011
Sill, corroded
BULK CARGO DOOR CUTOUT LOWER SILL INNER CHORD HAD CORROSION. ACCOMPLISHED REPAIR PER EA B767-53-015443.
- 11 Mar 2011
Skate Angle, cracked
IN LINE CRACK IN THE LEFT OUTBOARD NACELLE SKATE ANGLE FOR THE AFT FAIRING. ACCOMPLISHED REPAIR PER EA B767-64-005449.
- 10 Mar 2011
Skin, corroded
CORROSION OF THE FUSELAGE SKIN INNER SURFACE AT STATION 439 AND UNDER STRINGER 34 LEFT. ACCOMPLISHED DOUBLER REPAIR PER EA B767-53-015392.
- 9 Mar 2011
Bulkhead, cracked
STATION 1809 BULKHEAD FORWARD OUTER CHORD HAD 4 HOLE CRACKS. ACCOMPLISHED REPAIR PER EA 767-53-01-5391,
- 7 Mar 2011
Skin, delaminated
DELAMINATION OF NUMBER 6 SLAT LOWER SKIN 3 INCHES INBOARD OF THE OUTBOARD EDGE. ACCOMPLISHED REPAIR PER EA COMP-57-01-5569.
- 3 Mar 2011
Wedge, dented
NUMEROUS DENTS ON ALL 12 WING LEADING EDGE SLAT WEDGES. ACCOMPLISHED REPAIR PER EA B767-57-015326.
- 3 Mar 2011
Frame, dented
DENT DAMAGE TO THE STATIONS 500 AND 522 FUSELAGE FRAME INNER CHORD BETWEEN STRINGERS 29 TO 31 LEFT. ACCOMPLISHED REPAIR PER EA B767-53-015336.
- 24 Nov 2010
Pump, inoperative
SFO - INFLIGHT DFW-HNL. CREW REPORTED IN CRUISE THE LEFT AFT FUEL BOOST PUMP PRESSURE LIGHT ILLUMINATED AND EICAS MESSAGE ALSO ILLUMINATED. EMERGENCY DECLARED…
- 16 Nov 2010
Generator, failed
DFW - CREW REPORTED RIGHT GENERATOR FAILED ON CLIMBOUT. EMERGENCY DECLARED, RETURNED DFW LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED…
- 13 May 2010
Switch, faulty
LAX INFLIGHT DFW-HNL. CREW REPORTED DURING CLIMB EICAS MESSAGE "LEFT ENGINE BLEED OVERHEAT" INDICATION CAME ON. EMERGENCY DECLARED FLIGHT DIVERTED LAX LANDED…
- 9 Jun 2009
Unknown, fire
FIRE REPORTED IN WATER HEATER COMPARTMENT IN M1 LAVATORY WHILE IN FLIGHT. FLIGHT CREW USED ALL WATER FIRE EXTINGUISHERS AND HALON BOTTLE TO EXTINGUISH FIRE.…
- 22 Dec 2008
Battery Pack, inoperative
SFO - EMERGENCY LIGHT BATTERY PACK FOR SEAT ROWS RIGHT 10 TO 17 HAS FUSE BLOWN. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 21 Nov 2008
Seal, leaking
INFLIGHT FCF - APPROXIMATELY FIVE MINUTES AFTER LEVEL OFF AT 40000 FEET OIL QUANTITY INDICATION ILLUMINATED OR NUMBER TWO ENGINE THEN WENT RAPIDLY TO ZERO.…
- 28 Apr 2008
Pump, malfunctioned
JFK INFLIGHT T92/28APR ORD TO DUB - CREW REPORTED LEFT AFT FUEL BOOST PUMP LOW PRESSURE LIGHT ILLUMINATED AND CIRCUIT BREAKER POPPED. LANDED JFK WITHOUT…
- 18 Apr 2008
Stringer, corroded
AFW - FUSELAGE STRINGER 35L AT STATION 1307 HAD CORROSION. REPAIRED FUSELAGE STRINGER 35L AT STATION 1307 PER MRB 767 3181 DATED 08 APR 2008.
- 29 Oct 2007
Lamp, inoperative
SFO - EMERGENCY LIGHT AT OVERHEAD A6 LAVATORY INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT OVERHEAD A6 LAVATORY. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 24 Feb 2007
Handle, inoperative
CDG - FOUND EMERGENCY EXIT HANDLE AT SEAT 20J PANEL INOPERATIVE. REINSTALLED EMERGENCY EXIT HANDLE AT SEAT 20J PANEL. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 18 Nov 2006
Battery Pack, discharged
DFW - OUTSIDE EMERGENCY LIGHTS ON RIGHT SIDE OF CABIN INOPERATIVE. REPLACED BATTERY PACK AND CHARGER M733 FOR OUTSIDE EMERGENCY LIGHTS ON RIGHT HAND SIDE OF…
- 5 Nov 2006
Connector, loose
DFW - EMERGENCY PATH LIGHT AT SEAT 25H INOPERATIVE. RESEATED EMERGENCY LIGHT CONNECTOR AT SEAT 25H. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 5 Nov 2006
Lens, damaged
DFW - EMERGENCY LIGHT AT SEAT 41B HAS DAMAGED LENS. REPLACED EMERGENCY LIGHT LENS AT SEAT 41B. SYSTEM GROUND CHECKED NORMAL OPERATION. (CLOSED)
- 27 Oct 2005
Battery Pack, inoperative
LAX - EMERGENCY LIGHTS FROM 20AB TO 24AB SEATS INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS FORM 20AB TO 24AB SEATS. SYSTEM GROUND CHECKED NORMAL…
- 27 Oct 2005
Battery Pack, inoperative
ORD - LEFT OVERWING SLIDE SQUIB DOES NOT TEST IN COCKPIT. REPLACED M961 AND M962 BATTERY PACKS FOR LEFT OVERWING SLIDE SQUIB IN COCKPIT. SYSTEM GROUND CHECKED…
- 11 Mar 2005
Fastener, cracked
AFW - SEVEN LOCK FASTENER COLLARS CRACKED INSIDE FUEL TANKS AT WING STATION 261.2 LEFT HAND 394.2 LEFT HAND, 308.1 RT, 798.2 RIGHT HAND. REPLACED SEVEN EACH…
- 28 Feb 2005
Longeron, cracked
AFW - RIGHT HAND UPPER LONGERON WEB AT STRINGER 12 RIGHT JUST FORWARD OF STATION 1809 CRACKED. CUT OUT DAMAGED WEB AT APPROXIMATELY STATION 1798 AND…
- 28 Feb 2005
Floorbeam, corroded
AFW - FLOORBEAM AT STATION 325 (GENERAL LOCATION SECTION 41) HAS CORROSION REMOVAL ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM LIMITS. AREA IS 1.0 INCH…
- 14 Dec 2004
Light, damaged
DFW - EMERGENCY EXIT LIGHT AT SEAT 36H DAMAGED. REPAIRED EMERGENCY LIGHT AT SEAT 36H. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 18 Aug 2004
Terminal, smoke
EZE - TEN MINUTES AFTER TAKEOFF STRONG ELECTRICAL SMOKE SMELL IN COCKPIT. PERFORMED ELECTRICAL FIRE AND SMOKE EMERGENCY CHECKLIST BUT SMOKE NEVER ABATED.…
- 28 May 2004
Connector, loose
EMERGENCY LIGHT AT SEAT 35H INOPERATIVE. FOUND LOOSE CONNECTOR. TIGHTENED AND SECURED EMERGENCY LIGHT CONNECTOR AT SEAT 35H. SYSTEM GROUND CHECKED NORMAL…
- 3 Sep 2003
Connector, loose
DFW - EMERGENCY EXIT LIGHTS INOPERATIVE AT ROW 17H. BATTERY PACK FAILED DUAL FEED CHECK. CONNECTED SEAT WIRING CONNECTOR. SYSTEM GROUND CHECKED NORMAL…
- 24 Aug 2003
Light, inoperative
FOUND EXTERNAL EMERGENCY EXIT LIGHTS LEFT OVERWING, ALL THREE ARE INOPERATIVE. ALSO, 1L EXT EMERGENCY EXIT LIGHT IS INOPERATIVE. REPLACED M736 AND OPS CHECKED…
- 22 Jul 2003
Transceiver, inoperative
FLT 1539 - MIA-SFO - WEATHER RADAR INOPERATIVE. AIRCRAFT RETURNED MIA AND LANDED WITHOUT INCIDENT. REPLACED WEATHER RADAR TRANSCEIVER. SYSTEM GROUND CHECKED…
- 22 Jul 2003
Transceiver, failed
WEATHER RADAR DISPLAYED RT WEAK AND THEN WX FAIL BOTH SIDES, RADAR WAS COMPLETELY INOPERATIVE. REMOVED ND REPLACED WX RADAR TRANSCEIVER AS PER MM ACCOMPLISHED…
- 24 May 2001
Connector
MIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS BEHIND SEAT 3AB INOPERATIVE. RESECURED CONNECTOR AT SEAT 3AB. SYSTEM GROUND CHECKED…
- 19 May 2000
Indicator, malfunctioned
DFW - FLT 78 - AFTER TAKEOFF, HYDRAULIC QUANTITY EICAS MESSAGE ILLUMINATED AND QUANTITY INDICATION SHOWED OO RF. RETURNED AND LANDED DFW WITHOUT INCIDENT.…
- 7 May 2000
Light, inoperative
LAX - DURING OVERNIGHT MAINTENANCE, RIGHT AFT SERVICE DOOR EXTERIOR EMERGENCY LIGHT INOPERATIVE. REPLACED RIGHT AFT SERVICE DOOR EXERIOR EMERGENCY LIGHT.…
- 22 Nov 1999
Wire, failed
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT PATH LIGHT AT SEAT/ROW 26AB INOPERATIVE. REPLACED WIRING FOR EMERGENCY EXIT PATH LIGHT AT SEAT/ROW 26AB…
- 7 Sep 1998
Wire, broken
DFW - DURING OVERNIGHT CHECK, EMERGENCY EXIT SEAT LIGHT AT 24H INOPERATIVE. REPAIRED CONNECTOR WIRE AT SEAT 24H. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 19 May 1998
Connector, damaged
SFO - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT LIGHTS AT SEATS 26H AND 31H INOPERATIVE. REPAIRED EMERGENCY EXIT LIGHT CONNECTORS AT SEATS 26H AND 31H.…
- 26 Aug 1997
Air Distribution, odor
MIA - FLT 596 - AFTER TAKEOFF MIA DURING CLIMB-OUT, SLIGHT SMOKE AND OIL ODOR NOTED IN AREA OF PAX SEAT ROWS 25 AND 26 WITH NO OTHER ABNORMAL INDICATIONS.…
- 7 Aug 1997
Connector, defective
SFO - DURING OVERNIGHT CHECK, EMERGENCY EXIT LIGHT ON PAX SEAT 29H INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT CONNECTOR ON PAX SEAT 29H. SYSTEM GROUND CHECKED…
- 31 Aug 1996
Switch, defective
DFW - FLT 79 - AFTER TAKEOFF LGW DURING CLIMB TO CRUISE ALTITUDE, EMERGENCY EXIT AND PATH LIGHTING BEGAN OPERATING INTERMITTENTLY. AFTER 20 MINUTES OF…
- 16 Jun 1996
Connector, defective
SFO - DURING OVERNIGHT CHECK, EMERGENCY EXIT LIGHT AT PAX SEAT 27H INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT CONNECTOR AT PAX SEAT 27H. SYSTEM GROUND CHECKED…
- 13 Dec 1995
Connector, failed
SFO - DURING OVERNIGHT CHECK, FOUND EMERGENCY EXIT LIGHT AT 24H INOPERATIVE. REPAIRED CONNECTOR, SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 20 May 1995
Eel Assy, defective
SFO - DURING OVERNIGHT CHECK, MID-GALLEY EMERGENCY LIGHT LEFT SIDE OF LAMP INOPERATIVE. REPLACED EMERGENCY LIGHT ASSEMBLY AT MID-GALLEY. SYSTEM GROUND CHECKED…
- 29 Apr 1995
Eel Connector, loose
SFO - DURING OVERNIGHT CHECK, EMERGENCY EXIT LIGHTS UNDER AFT FLIGHT ATTTENDANT SEATS INOPERATIVE. RESECURED LOOSE EMERGENCY EXIT LIGHT CONNECTOR UNDER AFT…
- 9 Apr 1995
Oven, dirty
LHR - FLT 108 - EN ROUTE BOS-LHR - DURING CRUISE, FIRST CLASS GALLEY OVEN EMITTED SMOKE FROM INSIDE OVEN COMPARTMENT DURING USE. NO OTHER ABNORMAL…
- 1 Feb 1995
Eel Strip, defective
ORD - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHT AT FIRST CLASS GALLEY RT AISLE FOUND INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT AT FIRST CLASS GALLEY RT…