N346US
1987 Boeing 737-301 standard FAA →
earlier registrations
1 past record
- 1987
service difficulty reports
58 reports
- 20 Aug 2002
Coupler, faulty
ENROUTE, CLIMBING THROUGH FL210, AIRCRAFT EXPERIENCED A PULSING LEFT/RIGHT YAWING CONDITION. ONCE AUTOPILOT, AUTOTHROTTLE AND YAW DAMPER WERE OFF, YAWING…
- 12 Nov 2001
Skin, corroded
TPA - FOUND SKIN CORRODED 3 SQUARE INCHES, STRINGER 25L STATION 975. SPLICED IN SECTION OF STRINGER PER SRM 53-00-03 PAGE 201. (M)
- 16 Apr 2001
Skin, cracked
CLT - FOUND SKIN CRACKED 2 INCHES, STATION 947 AT STRINGER 34L, FORWARD OF POTABLE WATER SERVICE PANEL. INSTALLED DOUBLER PER SRM 53-00-01, FIG 201. (M)
- 16 Apr 2001
Bulkhead, cracked
CLT - FOUND WEB CRACKED 2 INCHES, BS 178, RBL 6, BETWEEN WL 197 AND 205. INSTALLED DOUBLER SRM 53-10-08, EO 5300V153. (M)
- 27 Mar 2001
Coffeemaker, shorted
MIA - FLT 1191 - EN ROUTE FROM CLT-MIA, FLIGHT ATTENDANT REPORTED A SCORCHING SMELL IN THE FORWARD GALLEY APPROXIMATELY TEN MINUTES BEFORE LANDING AT MIA.…
- 19 Jan 2001
Warning System, malfunctioned
ORF - FLT 12 - AFTER TAKEOFF FROM MCO, CREW RECEIVED A RIGHT MLG RED LIGHT WHEN PLACING THE GEAR HANDLE TO THE UP POSITION AS WELL AS THE OFF POSITION. AFTER…
- 6 Nov 2000
Door, not closed
ATL - FLT 1273 - AFTER TAKEOFF FROM ATL, THE AIRCRAFT WOULD NOT PRESSURIZE. CRWE NOTICED THE AFT RIGHT SERVICE DOOR WAS LEAKING AIR. FLIGHT RETURNED TO FIELD…
- 5 Sep 2000
Battery Pack, discharged
GSO - MAINTENANCE FOUND THE MID CABIN EMERGENCY LIGHTS AT THE OVERHEAD BIN DOORS WEAK. MAINTENANCE REMOVED AND REPLACED THE BATTERY PACK. OPERATIONAL CHECK…
- 17 Jan 2000
Frame, corroded
STATION 747 - AFT BAG BIN FRAME HAS A 1 INCH AREA OF CORROSION, LEVEL 1. FABRICATED REPAIR PER SRM 51-30-01 AND 53-00-07. (M)
- 13 Jan 2000
Keelbeam, corroded
FOUND LBL 6.5, STATION 528, 537 TO 539 KEEL BEAM HAS A 2 INCH BY 1 INCH AREA OF CORROSION, LEVEL 2. INSTALLED REPAIR ANGLE PER EA 66434, SRM 51-70-12. (M)
- 13 Jan 2000
Keelbeam, corroded
RBL 6.5 STATION 528 TO 533 KEEL BEAM HAS A 5 INCH BY 1 INCH AREA OF CORROSION, LEVEL 2. INSTALLED REPAIR ANGLE PER EA 66434, SRM 51-70-12. (M)
- 12 Jan 2000
Tie Clip, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .125 INCH CRACK AT BS 887, STRINGER 9L TIE CLIP. INSTALLED TIE CLIP PER SRM 51-10-02. (M)
- 12 Jan 2000
Tie Clip, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .125 INCH CRACK AT BS 663, STRINGER 10R TIE CLIP. INSTALLED TIE CLIP PER SRM 51-10-02. (M)
- 12 Jan 2000
Tie Clip, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK AT BS 807, STRINGER 6R TIE CLIP. INSTALLED TIE CLIP PER SRM 51-10-02. (M)
- 12 Jan 2000
Frame, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK AT BS 847, STRINGER 8R AND 9R FRAME. INSTALLED DOUBLER PER TR 53-10-14. (M)
- 12 Jan 2000
Frame, cracked
CLT - DURIGN Q-3 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK AT BS 480, STRINGER 8R AND 9R FRAME. INSTALLED DOUBLER PER TR 53-10-14. (M)
- 12 Jan 2000
Frame, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK BS 847 BETWEEN STRINGER 8L AND 9L FRAME. INSTALLED DOUBLER PER TR 53-10-14. (M)
- 12 Jan 2000
Floorbeam, corroded
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH AT 3 AREAS UPPER CHORD TOP SURFACE BS 312, LBL 12 - RBL 24. FLOORBEAM CORROSION LEVEL 2.…
- 12 Jan 2000
Tie Clip, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .125 INCH CRACK AT BS 663, STRINGER 10L TIE CLIP. INSTALLED NEW TIE CLIP PER SRM 51-10-02. (M)
- 12 Jan 2000
Floorbeam, corroded
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY .05 INCH AREA OF CORROSION ON FLOORBEAM STATION 344, RBL 2.5 AFT EDGE OF T-CAP. CORROSION LEVEL 1.…
- 12 Jan 2000
Floorbeam, corroded
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY .05 INCH AREA OF CORROSION ON FLOORBEAM STATION 344, LBL 9.5 UPPER CHORD OF T-CAP. CORROSION LEVEL…
- 12 Jan 2000
Stringer, corroded
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY .5 INCH, AREA OF CORROSION ON STRINGER 10R, STATION 337. CORROSION LEVEL 1. INSTALLED NEW STRINGER…
- 12 Jan 2000
Splice, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .125 INCH CRACK STRINGER 4R STATION 908 SPLICE. INSTALLED STRINGER PER SRM 51-40-00. (M)
- 12 Jan 2000
Frame, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK AT BS 827 BETWEEN STRINGER 8L AND 9L FRAME. INSTALLED DOUBLER PER TR 53-10-14 AND EA 66285. (M)
- 12 Jan 2000
Stringer, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND TWO .25 INCH CRACKS STRINGER 4L AT BS 908 AND 909 STRINGER. INSTALLED STRINGER PER SRM 51-40-00. (M)
- 12 Jan 2000
Frame, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .250 INCH CRACK BS 480 BETWEEN STRINGER 8 AND 9 LEFT FRAME. INSTALLED DOUBLER AND FILLER PER TR 53-10-14. (M)
- 12 Jan 2000
Bulkhead, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .75 INCH CRACK AT STATION 178, RBL 4.75, WL 201 BULKHEAD. INSTALLED DOUBLER PER SRM 53-10-8 AND EA 66276. (M)
- 12 Jan 2000
Angle, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .500 INCH CRACK AT STATION 294, OUTBOARD SIDE OF Z-ANGLE VERTICAL LEG SUPPORT ANGLE. REMOVED AND REPLACED…
- 12 Jan 2000
Frame, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK FORWARD SERVIEC DOOR CUTOUT UPPER FORWARD FRAME WEB UPPER DOOR STOP FRAME. REMOVED AND…
- 12 Jan 2000
Door Frame, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .5I NCH CRACK DOOR FRAME CUTOUT UPPER FORWARD STOP FITTING DOOR FRAME WEB. REMOVED AND REPLACED PER SRM…
- 12 Jan 2000
Seat Track, corroded
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 2 INCH AREA OF CORROSION AT FORWARD END OF SEAT TRACK STATION 345, LBL 20. REPLACED SEAT TRACK PER SRM…
- 12 Jan 2000
Angle, corroded
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY 4 INCH AREA OF CORROSION AT STATION 294.6 UPPER CHORD AFT FLANGE RBL 50.5, CORROSION LEVEL 1.…
- 12 Jan 2000
Skin, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND TWO 1.9 INCH CRACKS BS 328 FORWARD SERVICE DOORWAY, DOOR CUTOUT AFT LOWER CORNER FUSELAGE SKIN. INSTALLED…
- 12 Jan 2000
Skin, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND FIVE 1 INCH CRACKS ALONG ACTUATOR LOWER SKIN NR 1 SLAT. INSTALLED FILLER AND DOUBLER PER TR 57-50-01. (M)
- 12 Jan 2000
Window Post, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 1.5 INCH CRACK L-1 WINDOW AFT UPPER POST. INSTALLED DOUBLER PER EA 66274. (M)
- 12 Jan 2000
Frame, corroded
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY 2 INCH AREA OF CORROSION AFT CARGO BS 793 STRINGER 25R FRAME, CORROSION LEVEL 1. REPAIRED PER SRM…
- 12 Jan 2000
Angle, corroded
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 36 INCH BY 2 INCH AREA OF CORROSION FORWARD SERVICE DOOR Z-ANGLE STATION 289-325, RBL 61. CORROSION LEVEL 1.…
- 12 Jan 2000
Frame, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .250 INCH CRACK AT BS 311.9, STRINGER 5L CORNER OF FRAME. INSTALLED DOUBLER PER EA 66257 AND TR 53-10-14. (M)
- 12 Jan 2000
Web, cracked
CLT - DURIGN Q-3 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK AT BS 294.5, STRINGER 7L, IN CORNER MOUNT POINT WEB. REMOVED AND REPLACED PER SRM 51-10-02 AND…
- 12 Jan 2000
Web, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 3 INCH CRACK AT BS 306.0, STRINGER 4L MIDDLE LOWER LEG WEB. REMOVED AND REPLACED PER SRM 53-00-03. (M)
- 12 Jan 2000
Stringer, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .375 INCH CRACK AT STATION 726, STRINGER 18A SHELF, RBL 61, WL 188. REPAIRED PER SERM 51-10-02. (M)
- 12 Jan 2000
Web, cracked
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .125 INCH CRACK AT N/G UPPER DRAG HRM WEB. INSTALLED NEW WEB PER REPAIR DOCUMENT 51-10-02. (M)
- 12 Jan 2000
Frame, corroded
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 6 INCH BY 1.5 INCH AREA OF CORROSION ON FRAME STATION 927 BETWEEN STRINGER 27L AND STRINGER 7R. CORROSION…
- 12 Jan 2000
Floorbeam, corroded
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 1 INCH AREA OF CORROSION ON FLOORBEAM STATION 344, BL 0 UPPER CHORD, CORROSION LEVEL 2. SPLICED IN NEW T-CPA…
- 2 Nov 1999
Sensor, failed
CHS - FLT 542 - DURING CLIMB-OUT FROM CHS, FLIGHT EXPERIENCED A FAILURE OF BOTH ATC TRANSPONDERS AND THE LEFT NAV FUNCTION OF THE AUTOPILOT. FLIGHT RETURNED…
- 21 Aug 1998
Skin, cracked
TPA - DURING CX-1 CHECK VISUAL INSPECTION, FOUND A 1.25 INCH CRACK IN SKIN E/E DUCT COOLING OUTLET STATION 379 LBL 30. INSTALLED DOUBLER OF .100 INCH 2024-T3…
- 24 Jun 1998
Detector, failed
SBN - FLT 7002 - ABOUT 60 MILES OUT OF SBN, THE NR 2 ENGINE OVERHEAT LIGHT ILLUMINATED. AFTER GOING THROUGH CHECKLIST, CAPTAIN ELECTED TO RETURN TO FIELD AT…
- 20 Dec 1997
Wire, failed
CLT - CREW REPORTED THAT THE EMERGENCY FLOOR LIGHTS AT ROW 10 WERE INOP. MAINTENANCE REPAIRED/SPLICED WIRES. OPERATIONAL CHECK GOOD. (M)
- 16 Apr 1997
Control Panel, malfunctioned
RDU - FLT 1416 - EN ROUTE MCO TO BWI, FLIGHT ENCOUNTERED NR 1 ENGINE GENERATOR FAILURE. NR 1 ENG FIRE WARNING LIGHT ILLUMINATED, BELL DID NOT SOUND. CREW SHUT…
- 16 Apr 1997
Control Module, malfunctioned
RDU - FLT 1416 - EN ROUTE MCO TO BWI, FLIGHT ENCOUNTERED NR 1 ENGINE GENERATOR FAILURE. NR 1 ENG FIRE WARNING LIGHT ILLUMINATED, BELL DID NOT SOUND. CREW SHUT…
- 20 Apr 1996
Fire Detector, failed
FLT NR 1021 - PHL - ON CLIMB-OUT AT 2500 FEET, RIGHT ENGINE FIRE WARNING LIGHT AND BELL CAME ON. COMPLETED ENGINE FIRE CHECK LIST. FIRE WARN LIGHT DID NOT GO…
- 20 Apr 1996
Fire Detector, failed
FLT 1021 - PHL - ON CLIMB-OUT AT 2500 FEET, RIGHT ENGINE FIRE WARNING LIGHT AND BELL CAME ON. COMPLETED ENGINE FIRE CHECK LIST. FIRE WARNING LIGHT DID NOT GO…
- 23 Jan 1996
Skin, damaged
CLT - INSPECTION VISUALLY FOUND A .25 INCH IMPACT DAMAGE TO COMPOSITE SKIN THROUGH COMPOSITE LAYERS LOCATED RIGHT ELEVATOR SKIN 15 INCHES OUTBOARD FROM…
- 23 Jan 1996
Doubler, misinstalled
CLT - INSPECTION VISUALLY FOUND AN 8 INCH BY 8 INCH EXTERNAL DOUBLER WITH BLIND FASTENERS, LOCATED AT FS 1006 TO 1016 BETWEEN STRINGER 23R THROUGH STRINGER…
- 23 Jan 1996
Floor Beam, cracked
CLT - INSPECTION BY HFEC, FOUND A CRACK APPROXIMATELY 1 INCH, LOCATED AT THE FLOOR BEAM, STATION 520, LBL 25. INSTALLED DOUBLER AND RADIUS BLOCK AS PER USA EO…
- 23 Jan 1996
Floor Beam, cracked
CLT - INSPECTION BY HFEC, FOUND A CRACK APPROXIMATELY 1 INCH LOCATED AT THE FLOOR BEAM, STATION 520, RBL 45. FABRICATED AND INSTALLED DOUBLERS AND FILLERS AS…
- 23 Jan 1996
Floor Beam, cracked
CLT - INSPECTION FOUND BY HFEC, A CRACK APPROXIMATELY 1 INCH LOCATED AT FLOOR BEAM STATION 520, LBL 45. FABRICATED AND INSTALLED DOUBLERS AND FILLERS AS PER…
- 23 Jan 1996
Skin, torn
CLT - INSPECTION VISUALLY FOUND 2 INCHES OF TORN SKIN AT EDGE OF CUTOUT, GND AIR/COND LOCATED APPROXIMATELY FS 530 BL0. INSTALLED REPAIR STRAP AS PER USAIR EO…