N338SB
2007 Pilatus PC-6/B2-H4 standard FAA →
registration
- 2007
service difficulty reports
21 reports
- 23 May 2003
Hose, leaking
DURING CLIMB-OUT OF SBA, CREW RECEIVED A HYDRAULIC WARNING ON THE CWP. HYDRAULIC PUMP WAS SELECTED OFF DUE TO HYDRAULIC QUANTITY GOING DOWN. CREW DECLARED AN…
- 14 Nov 2001
Ballast, defective
DFW - FLT 3525 - DURING PREFLIGHT, CREW NOTED A STRONG SMELL OF BURNING WIRE OR INSULATION. MAINTENANCE FOUND A BAD LIGHT BALLAST AT LOCATION 22. BALLAST WAS…
- 24 Jul 2001
Skin, damaged
ABI - DURING AN HMBV INSPECTION, MAINTENANCE FOUND DAMAGE IN THE LEFT NACELLE EXTERIOR SKIN. DAMAGE WAS REPAIRED IAW SAAB REPAIR STATEMENT 340SDS002123.…
- 19 Jul 2001
Frame, damaged
ABI - DURING MBV, FRAME 658.5 WAS FOUND TO HAVE WEB DAMAGE ON THE RIGHT SIDE ABOVE WL 73.5. REMOVED AND REPLACED LOWER PORTION OF FRAME 658.5 AT THE FACTORY…
- 17 Apr 2000
Bulb, failed
DFW - FLT 3252 - FLOOR PROXIMITY EMERGENCY LIGHT AT 4B INOPERATIVE. REMOVED AND REPLACED BULB AT 4B. OPS CHECK GOOD. (M)
- 15 Apr 2000
Bulb, failed
DFW - FLT 3503 - EMERGENCY EXIT LIGHT AT 8A INOPERATIVE. REMOVED AND REPLACED BULB AT 8A. OPS CHECK GOOD. (M)
- 23 Mar 2000
Downlock Switch, intermittent
DFW - FLT 3401 - SHORTLY AFTER TAKEOFF LEFT MAIN LANDING GEAR GREEN LIGHT CAME ON. LIGHT WAS INTERMITTENT. PERFORMED INSPECTION AND FOUND SEVERAL FRAYED WIRES…
- 5 Mar 1999
Skin, dented
ABI - DURING A MBV INSP, DENTS DISCOVERED ON THE CARGO DOOR SKIN BEYOND SRM LIMITS. PERFORMED EDDY CURRENT INSP AND A BOND TEST. CUT OUT DAMAGED AREA OF ONE…
- 27 Oct 1998
Connector, loose
AEX - FLT 5092 - CARGO SMOKE WARNING LIGHT ILLUMINATED AND EXTINGUISHED. DISCHARGED ONE FIRE EXTINGUISHER AND DIVERTED INTO AEX. TIGHTENED LOOSE CANNON PLUG…
- 29 Aug 1998
Generator, failed
TXK - FLT 5008 - RIGHT AC GENERATOR AND INLET LIGHT ILLUMINATED. SHORTLY AFTER THE RIGHT ENGINE OIL PRESSURE WARNING LIGHT ILLUMINATED ON THE CWP. RIGHT PROP…
- 28 Jul 1998
Power Supply, discharged
OVERHEAD EMERGENCY LIGHTS AT SEAT 9A AND 11A DO NOT ILLUMINATE. REMOVED AND REPLACED EMERGENCY LIGHT POWER SUPPLY AT ROWS 9/10. OPERATIONAL CHECK GOOD. (X)
- 17 Jul 1998
Bulb, inoperative
DFW - FLT 5166 - TWO EMERGENCY OVERHEAD LIGHTS AT ROWS 9 AND 11 DO NOT ILLUMINATE. REMOVED AND REPLACED BULBS AT ROWS 9 AND 11 OVERHEAD LIGHTS. OPERATIONAL…
- 15 Apr 1998
Smokedetector, defective
FLIGHT 5034, BTR, AVIONICS SMOKE LIGHT ILLUMINATED. REPLACED THE SMOKE DETECTOR.
- 16 Feb 1998
Windshield, failed
CREW REPORTED SMELL OF HOT METAL OR INSULATION BURNING IN THE COCKPIT. MAINTENANCE FOUND THE LEFT FRONT COCKPIT WINDSHIELD HEATING ELEMENTS BURNED OUT.…
- 15 Feb 1998
Air Distribution, odor
CREW REPORTED A HOT SMELL OR BURNING INSULATION IN THE COCKPIT BUT NO SMOKE NOTED. MAINTENANCE REMOVED THE AVIONICS RACK DOOR AND PANELS, CIRCUIT BREAKER…
- 28 Aug 1997
Smoke Detector, defective
CARGO SMOKE LIGHT CAME ON, CREW FIRED EXTINGUISHER NR 1, THE LIGHT WENT OUT. MAINTENANCE REPLACED BOTH FORWARD AND AFT CARGO SMOKE DETECTORS. REPLACED NR 1…
- 27 Jul 1997
Lamp, failed
DURING PREFLIGHT CREW, FOUND FLOOR EMERGENCY LIGHT AT ROW 8 INOPERATIVE. MAINTENANCE RELAMPED THE FLOOR EMERGENCY EXIT LIGHT LEFT SIDE ROW 8A.
- 11 Sep 1996
Control Cable, defective
CREW REPORTS THAT THE PARKING BRAKE FRICTION LOCK SLIPS, RELEASING THE PARKING BRAKE UNEXPECTEDLY. MAINTENANCE REPLACED THE INNER PARKING BRAKE TELEFLEX CABLE…
- 28 Oct 1995
Connector, contaminated
THE FLIGHT ATTENDANT REPORTED SMELLING AN ELECTRICAL BURNING SMELL AT THE NR 2 HOT JUG. UPON INVESTIGATION, MAINTENANCE FOUND THE EXTERIOR OF THE WATER JUG…
- 14 Sep 1995
Universal Joint, failed
DURING TAXI, THE NOSE WHEEL STEERING BECAME INEFFECTIVE IN A TURN TO THE LEFT. UPON INVESTIGATION, MAINTENANCE FOUND STEERING UNIVERSAL JOINT IN GEARBOX (LEFT…
- 12 Mar 1995
Air Distr, odor
FLIGHT 5382 (ABI/DFW), PILOT REPORTED SMELLING A BURNING OIL ODOR COMING FROM THE BLEED AIR SYSTEM. MAINTENANCE RAN THE RIGHT AND LEFT ENGINES FOR 30 MINUTES…