N337US
2014 Smith Mark R MINI MAX 1500R (kit Jdt Mini-Max LLC Mini Max 1500R) experimental, amateur built FAA →
registration
- 2014
earlier registrations
1 past record
- 1986
service difficulty reports
57 reports
- 4 Sep 2002
Skin, cracked
CLT - FOUND SKIN CRACKED 2.1 INCH, S23R AT STATION 727D PLUS 4. INSTALLED DOUBLER AND TRIPLER PER EA 74734. (M)
- 31 Aug 2002
Skin, cracked
CLT - FOUND SKIN CRACKED 1 INCH, S22L AT STATION 727D PLUS 13. INSTALLED DOUBLER PER SRM 53-00-01 FIG 201. (M)
- 17 Jul 2002
Battery Pack, inoperative
PHL - MAINTENANCE FOUND THE EMERGENCY EXIT LIGHT ABOVE THE AFT LEFT ENTRY DOOR INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BATTERY PACK. OPERATIONAL…
- 1 Jun 2002
Landing Gear, out of rig
IN PREPARATION FOR LANDING, CREW EXPERIENCED A LANDING GEAR INDICATION PROBLEM. GREW RECEIVED 3 GREEN AND 3 RED LANDING GEAR LIGHTS WHEN SELECTING GEAR DOWN.…
- 27 Apr 2002
Control Handle, lack of lube
PHL - FLT 577 - ON GEAR EXTENSION FOR LANDING, CREW RECEIVED THREE GREEN LIGHTS AND THEN THREE RED LIGHTS. CREW EXECUTED A MISSED APPROACH AND CYCLED THE…
- 26 Dec 2001
Battery Pack, discharged
GSO - MAINTENANCE FOUND THE EMERGENCY LIGHTS IN FIRST CLASS EXTINGUISH AFTER A SHORT PERIOD OF OPERATION. MAINTENANCE REMOVED AND REPLACED THE BATTERY PACK.…
- 4 Dec 2001
Downlock Sensor, intermittent
CLT - FLT 841 - ON APPROACH TO CLT, WHEN THE GEAR WAS EXTENDED, THE CREW RECEIVED GREEN INDICATIONS FOR THE MAIN GEAR AND RED FOR THE NOSE GEAR. ON THE…
- 10 Sep 2001
Frame, cracked
CLT - FOUND CHORD CRACKED .25 INCH, BS 178 WL 207 LBL 26 AND RBL 26. DAMAGE AREAS WERE CUTOUT, SIDE CHORD SPLICE REPAIRS INSTALLED PER EO 5300V157. (M)
- 10 Sep 2001
Web, cracked
CLT - FOUND WEB CRACKED .5 INCH, BS 178 WL 213 RBL 6 AND WL 207 LBL 1. INSTALLED REPAIR DOUBLER PER EO 5300V153. (M)
- 30 Jun 2001
Skin, cracked
CLT - FOUND SKIN CRACKED 2 INCHES, BS 727E, STRINGER 22R AND 23R. DAMAGE REMOVED, REPAIR DOUBLER AND TRIPLER INSTALLED PER EA 71604. (M)
- 18 Jan 2001
Wire, disconnected
PIT - FLT 276 - AFTER TAKEOFF FROM AVP, EN ROUTE TO PIT, THE LANDING GEAR HANDLE WOULD NOT MOVE BEYOND THE OFF POSITION. CREW FOLLOWED QUICK REFERENCE…
- 22 May 2000
Unknown, odor
CLT - FLT 2151 - AFTER TAKEOFF, CREW NOTED A RUBBER LIKE SMELL IN THE CABIN. FLIGHT RETURNED TO CLT AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE PERFORMED…
- 8 May 2000
Fire Loop, failed
PIT - FLT 2004 - ON CLIMB-OUT FROM PIT, EN ROUTE TO LGA, THE CREW NOTED AN ENGINE OVERHEAT WARNING ON THE NR 2 ENGINE. THE A LOOP FOR THE NR 2 ENGINE WAS ON…
- 17 Dec 1999
Mec, faulty
CLT - FLT 299 - ON CLIMB-OUT FROM CLT, AT FL210, THE NR 1 ENGINE N1 INDICATOR BEGAN FLUCTUATING IN ALL PARAMETERS OF FLIGHT. THE N1 WOULD SURGE PLUS OR MINUS…
- 7 Aug 1999
Fuse, blown
PHL - DURING OPERATIONAL TEST OF EMERGENCY LIGHT SYSTEM ON OVERNIGHT CHECK, MAINTENANCE FOUND THE FIRST CLASS SEAT EMERGENCY LIGHTS FAILED TO FULLY…
- 21 Jun 1999
Web, cracked
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A .300 INCH CRACK AT STATION 727 STRINGER 18A LEFT MAIN WHEEL WELL SHEAR WEB. INSTALLED DEFECTIVE PART WITH…
- 21 Jun 1999
Bulkhead, cracked
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK AT STATION 178 BULKHEAD RBL 314 WL 187. INSTALLED DOUBLER PER SRM 53-10-08 FIG 203. (M)
- 21 Jun 1999
Bulkhead, cracked
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A .5 INCH, 1 INCH AND .75 INCH CRACK AT STATION 178 RIGHT SIDE PLUS 6 INCHES WL 200 AT 4.75 AND 6.75 BULKHEAD.…
- 21 Jun 1999
Skin, corroded
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 12 INCH AREA OF FUSELAGE OF CORROSION BETWEEN NR 3 VHF ANTENNA MOUNT STATION 727D PLUS 3 TO 727D PLUS 15 AND…
- 21 Jun 1999
Floorbeam, corroded
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 20 INCH AREA OF CORROSION BS 270, LBL 10 - RBL 10 FLOOR SUPPORT. INSTALLED NEW Z-ANGLE PER TR 53-20-04 AND…
- 21 Jun 1999
Floorbeam, corroded
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 2 INCH BY 3 INCH AREA OF CORROSION ON T-CAP AND AROUND NUT PLATE HOLES AT BS 294.5 FROM LBL 12 TO RBL 7.…
- 21 Jun 1999
Channel, corroded
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 1 INCH AREA OF CORROSION AT BS 986.5 RBL 24 HOT CHANNEL. CORROSION LEVEL 2. INSTALLED FABRICATED PART PER…
- 21 Jun 1999
Floorbeam, corroded
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 6 INCH AREA OF CORROSION AT STATION 986.5 LBL 24 FLOORBEAM, CORROSION LEVEL 2. FABRICATED NEW PART PER SRM…
- 21 Jun 1999
Frame, corroded
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 6 INCH AREA OF CORROSION ON INBOARD J CHANNEL BS 993.5 FRAME AT WL 208.1, CORROSION LEVEL 2. INSTALLED…
- 21 Jun 1999
Web, corroded
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 2 INCH AREA OF CORROSION AFT RIGHT LAV FILL CONN ON FLOOR WEB, CORROSION LEVEL 2. NEW WEB INSTALLED PER SRM…
- 21 Jun 1999
Floorbeam, corroded
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND 60 INCH AREA OF CORROSION AT STATION 986.5 FLOORBEAM. INSTALLED UPPER T-CAP PER SRM 53-00-51. (M)
- 21 Jun 1999
Floorbeam, corroded
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND 1 INCH AREA OF CORROSION AT BS 312, LBL 12 T-CAP. CORROSION LEVEL 2, CORROSION TASK NR C53-107-02. FABRICATED…
- 21 Jun 1999
Floorbeam, corroded
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND 1 INCH AREA OF CORROSION AT BS 312, LBL1 AND LBL 11 FLOORBEAM. CORROSION LEVEL 2, CORROSION TASK NR…
- 21 Jun 1999
Floorbeam, corroded
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND 1 INCH AREA OF CORROSION AT BS 312, BL 0 LBL 7 AND RBL 8 FLOORBEAM, CORROSION LEVEL 2, CORROSION TASK NR…
- 21 Jun 1999
Frame, cracked
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND 1.5 INCH CRACK ON FRAME AT STATION 727D AT LBL 2 INCH AT VERTICAL ANGLES FOR ANTENNA MOUNT. CUTOUT CRACK AND…
- 21 Jun 1999
Frame, cracked
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND .5 INCH CRACK AT STATION 727D AT LBL 02 AND RBL 02 FRAME. INSTALLED DOUBLER AND FILLERS PER SRM 53-60-07 AND…
- 21 Jun 1999
Skin, cracked
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A SMALL SKIN CRACK AT CARGO DOOR HANDLE CUTOUT AFT CARGO DOOR, AFT RADIUS OF HANDLE ACCESS CUTOUT EXTERIOR…
- 21 Jun 1999
Skin, cracked
CLT - DURING Q-1 CHECK, FOUND .75 INCH CRACK ON SKIN AT PILOTS NR 1 WINDOW CUTOUT UPPER OUTBOARD CORNER. FABRICATED DOUBLER PER EA 64783A. (M)
- 10 Jun 1999
Clip, cracked
CLT - DURING Q-1 CHECK, FOUND .250 INCH CRACK IN TIE CLIP AT BS 727D STRINGER 5 LEFT. DEFECTIVE PART REPLACED WITH IDENTICAL PART NUMBER PER SRM PARA 4. (M)
- 10 Jun 1999
Stringer, cracked
CLT - DURING Q-1 CHECK, FOUND 2 INCH CRACK IN STRINGER 4L AT STATION 907 ABOVE TIE CLIP AT STRINGER 4L. INSTALLED SPLICE ANGLE PER EA 64679 AND SRM 51-10-02.…
- 10 Jun 1999
Clip, cracked
CLT - DURING Q-1 CHECK, FOUND TWO .5 INCH CRACKS IN TIE CLIP AT BS 663 FRAME TO S-10L TIE CLIP. DEFECTIVE PART REPLACED WITH IDENTICAL PART NR PER SRM…
- 10 Jun 1999
Clip, cracked
CLT - DURING Q-1 CHECK, FOUND CRACKED TIE CLIP .125 INCH AT BS 663 STRINGER 10 RIGHT. DEFECTIVE PART REPLACED WITH IDENTICAL PART NR PER SRM 51-10-02. (M)
- 10 Jun 1999
Clip, cracked
CLT - DURING Q-1 CHECK, FOUND CRACKED TIE CLIP .125 INCH CRACK AT BS 706 STRINGER 2L. DEFECTIVE PART REPLACED WITH IDENTICAL PART NR PER SRM 51-10-02. (M)
- 10 Jun 1999
Clip, cracked
CLT - DURING Q-1 CHECK, FOUND .125 INCH CRACK IN TIE CLIP AT STATION 616 STRINGER 8L. DEFECTIVE PART REPLACED WITH IDENTICAL PART NR PER SRM 51-10-02. (M)
- 10 Jun 1999
Clip, cracked
CLT - DURING Q-1 CHECK, FOUND .125 INCH CRACK IN TIE CLIP AT STATION 616 STRINGER 4L. DEFECTIVE PART REPLACED WITH IDENTICAL PART NR PER SRM 51-10-02. (M)
- 10 Jun 1999
Gusset, cracked
CLT - DURING Q-1 CHECK, FOUND 3 INCH CRACK IN NOSE GEAR ACT FORWARD ATTACH FITTING GUSSET. REPLACED GUSSET WITH IDENTICAL PART NUMBER. (M)
- 10 Jun 1999
Clip, cracked
CLT - DURING Q-1 CHECK, FOUND .125 INCH CRACKED TIE CLIP AT BS 727A STRINGER 5 RT. DEFECTIVE PART REPLACED WITH IDENTICAL PART NR PER SRM 51-10-02. (M)
- 10 Jun 1999
Clip, cracked
CLT - DURING Q-1 CHECK, FOUND .12 5INCH CRACK IN TIE CLIP AT STATION 727C STRINGER 6L. DEFECTIVE PART REPLACED WITH IDENTICAL PART NR PER SRM 51-10-02. (M)
- 10 Jun 1999
Clip, cracked
CLT - DURING Q-1 CHECK, FOUND .5 INCH CRACK IN TIE CLIP AT STATION 727A FRAME TO STRINGER 6R. DEFECTIVE PART REPLACED WITH IDENTICAL PART NUMBER PER SRM…
- 10 Jun 1999
Floorbeam, corroded
CLT - DURING Q-1 CHECK, FOUND 6 CORROSION AT SCREW HOLE IN FLOORBEAM JOGGLE AT BS 860 RBL 8. INSTALLED REPAIR ANGLE PER TYPICAL REPAIR 53-10-06. (M)
- 10 Jun 1999
Floor, cracked
CLT - DURING Q-1 CHECK, FOUND 1.5 INCH CRACK AND .400 INCH CRACK JUST AFT OF STATION 663.75 BL 32 IN PRESSURE FLOOR PANEL. INSTALLED DOUBLER, FILLER AND ANGLE…
- 10 Jun 1999
Floorbeam, cracked
CLT - DURING Q-1 CHECK, FOUND 1 INCH CRACK IN LONGITUDINAL FLOORBEAM AT BS 708.5 AND BS 709.5. INSTALLED DOUBLER AND FILLER PER SRM 511-70-13. (M)
- 23 Dec 1998
Skin, cracked
TPA - DURING A CX-2 CHECK VISUAL INSPECTION, FOUND A .3125 INCH CRACK IN SKIN AT BS 375 AND BL 0. INSTALLED DOUBLER PER TR 53-30-07. (M)
- 24 Jul 1998
Battery Pack, discharged
IAH - MAINTENANCE FOUND THE EMERGENCY EXIT LIGHT AT THE AFT RIGHT SERVICE DOOR INOP. MAINTENANCE REMOVED AND REPLACED THE BATTERY PACK. OPERATIONAL CHECK…
- 20 Jul 1997
Light, inoperative
PHL - MAINTENANCE FOUND THE EMERGENCY SEAT LIGHTING AT SEAT ROW 10 ABC INTERMITTENT/INOP. MAINTENANCE FOUND A LOOSE WIRE/BAD CONNECTION AT LIGHT ASSEMBLY.…
- 27 Mar 1997
Battery Pack, discharged
TPA - DURING OPERATIONAL CHECK OF THE EMERGENCY EXIT LIGHTS, MAINTENANCE FOUND THE AFT LEFT CABIN AND THE CENTER RIGHT CABIN EXIT LIGHTS DID NOT ILLUMINATE.…
- 15 Jun 1995
Angle, corrosion
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 2 INCH, TWO HOLES THROUGH ANGLE CORROSION FORWARD ENTRY DOOR SILL Z-ANGLE. REPLACED Z-ANGLE SRM…
- 14 Jun 1995
Threshold, corroded
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 12 INCHES FORWARD SERVICE DOOR THRESHOLD. REPLACED Z-ANGLE. CORROSION TASK NR C53-107-02.…
- 14 Jun 1995
Channel, corrosion
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1.5 INCH BY 3 INCH CORROSION, BS 500 PLUS 6 INCHES BL 0. REPLACED CHANNEL WITH NEW CHANNEL SRM 51-10-02.…
- 14 Jun 1995
Floorbeam, corrosion
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 4 INCHES BY 1 INCH OF CORROSION BS 987.0 BL 40 LT T-CAP SECTION OF FLOORBEAM. FABRICATED NEW T-CAP, STRAP AND…
- 12 Jun 1995
Floorbeam, corrosion
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND CORROSION ON FLOORBEAM 1 INCH BY 12 INCHES STA 328 RBL 6 TO LBL 63. REPLACED UPPER T-CAP, TR 53-10-3.…
- 7 Jun 1995
Floor Beam, corrosion
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND CORROSION ON FLOORBEAM 2 INCHES BY 42 INCHES, STA 344 BL 0 TO LBL 42 INCHES. REMOVED T-CAP SECTION AND…