N327EN
1991 Boeing of Canada/Dehav Div DHC-8-311 standard FAA →
reservations
earlier registrations
1 past record
- 1991
service difficulty reports
128 reports
- 6 Mar 2019
Light, inoperative
DISCREPANCY: DURING HVY CHK MAINTENANCE FOUND CABIN - THREE FLOOR ESCAPE PATH EMERGENCY LIGHTS AT ROW 11 WILL NOT ILLUMINATE. CORRECTIVE ACTION: REMOVED AND…
- 21 Feb 2019
Wire, damaged
DURING HVY CHK MAINTENANCE FOUND BROKEN WIRE INSIDE WARDROBE BEHIND WALL O/B OF FLIGHT ATTENDANT SEAT FOR EMERGENCY LIGHTS EXIT SIGN. REPAIRED EMERGENCY EXIT…
- 12 Mar 2018
Landing Gear, malfunctioned
ON GEAR EXTENSION, THE NLG RED UNSAFE LIGHT & AMBER GEAR DOOR LIGHT. CREW TRIED TWICE. LOWERED GEAR WITH THE ALTERNATE EXTENSION, RECEIVED 3 GREEN LIGHTS. OPEN
- 10 Feb 2018
Wire, broken
FWD MOST FLOOR EMERGENCY LIGHT HAS A BROKEN WIRE. REPAIRED THE WIRE IAW AMM 20-45-07.
- 15 Dec 2017
Light, malfunctioned
EMERGENCY LIGHTS ILLUMINATE IN ARM POSITION. PERFORMED AN EMERGENCY LIGHTS OPS CHECK IAW 33-51-05. R & R THE EMERGENCY LIGHTS CONTROL BOX AS PRECAUTION IAW…
- 29 Oct 2017
Hose, leaking
PARK BRAKE HYD LEAK. R & R NR 1 MWA BRAKE FLEX HOSE. LEAK AND OPS CHECKED GOOD. OK FOR SERVICE.
- 23 Jun 2017
Relay, malfunctioned
UTO FX DID NOT ARM ON TAKEOFF ROLL WITH TQ UP TO 90 PERCENT. R & R THE NR 2 ENGINE TSEU AND ARM CONTROL RELAY. GROUND RAN ACFT IAW RUNUP MANUAL, OPS CHECKED…
- 18 Jun 2017
Autofeather Sys, malfunctioned
AUTOFEATHER DID NOT ARM DURING TAKE OFF ROLL. TORQUE WAS UP TO 90 PERCENT. INSPECTED FOR DEFECTS, NONE NOTED. PERFORMED ENGINE RUNS, SYSTEM OPS CHECKED GOOD…
- 3 Apr 2017
Bulb, inoperative
FORWARD MOST FLOOR EMERGENCY LIGHT INOPERATIVE. R & R THE BULB.
- 13 Mar 2017
Bulb, inoperative
12TH EMERGENCY FLOOR LIGHT IS INOPERATIVE. REMOVED AND REPLACED THE BULBS. OPS CHECKED GOOD.
- 3 Feb 2017
Circuit Card, failed
AUTOPILOT DISENGAGE CAUTION LIGHT WILL NOT RESET AFTER DC BUSS FAULT DURING ENGINE START. R & R THE AUTOPILOT DISENGAGE PANEL CIRCUIT CARD ASSEMBLY ON PILOT…
- 5 Dec 2016
Bulb, inoperative
FORWARD MOST RED EMERGENCY LIGHTS ARE INOPERATIVE. REMOVED AND REPLACED THE BULBS. OPS CHECKED GOOD.
- 12 Oct 2016
Bulb, inoperative
LEFT AFT EMERGENCY LIGHT IS INOPERATIVE. REMOVED AND REPLACED THE BULB. OPS CHECKED GOOD.
- 13 Jun 2016
Control Box, malfunctioned
WHEN PERFORMING BAG BAY SMOKE DETECTOR TEST WARNING LIGHTS DID NOT EXTINGUISH AFTER TEST. R & R WARNING LIGHT CONTROL BOX IAW -8 MM 26-12-00, OPS CHECK OK, OK…
- 12 Jun 2016
Tire, failed
CAPT SIDE INBD TIRE POPPED ON TAXI OUT. R & R NR 1 AND NR 2 MWA'S IAW AMM 32-41-11 AS REQUIRED. OK FOR SERVCICE.
- 7 May 2016
Line, bent
JET FUEL ODOR IN CABIN. AFTER MAINTENANCE INSPECTION, FOUND OIL RESIDUE ON RECIRC FAN AND ADJACENT DUCT WORK. AUXILIARY POWER UNIT. FOUND TEFLON CONNECTOR…
- 4 Jan 2016
Light, broken
LOWER ENTRY WAY EMERGENCY EXIT LIGHT IS MISSING SHIELD AND LIGHT ASSEMBLY IS BROKEN AT THE SCREWS. R & R LOWER ENTRY WAY EMERGENCY LIGHT AND INSTALLED NEW…
- 12 Oct 2015
Bulb, inoperative
EMERGENCY LIGHTS ARE INOPERATIVE AT ROWS 3 AND 9. R & R BULB, OPS CHECKED GOOD.
- 24 Jun 2015
Transceiver, malfunctioned
EGPWS PERFORMED AN UNCOMMANDED TEST CYCLE AT BEGINNING OF TAKEOFF ROLL. R & R RADAR RT. OPS CHECKED GOOD.
- 25 May 2015
Battery Pack, inoperative
LEFT AFT EGRESS LIGHT IS INOPERATIVE. R & R EMERGENCY BATTERY PS7 IAW MM 33-51-00. OPS CHECKED GOOD.
- 25 May 2015
Battery Pack, inoperative
AFT CENTER AISLE AND RT AFT EGRESS LIGHT IS INOPERATIVE. R & R EMERGENCY LIGHT BATTERY PS6 IAW MM 33-51-00. OPS CHECKED GOOD.
- 12 Jan 2015
Fuel Sys, leaking
NR 2 BLEEDS FUEL ODOR WHEN PROPELLERS ARE IN FEATHER. GROUND RAN ACFT. COULD NOT DUPLICATE. SUSPECT FUEL ODOR IS FROM SEEP FROM RT WING.
- 14 Nov 2014
Bulb, inoperative
FLOOR EMERGENCY LIGHT IS INOPERATIVE AT ROW 12DF. R & R THE BULB. OPS CHECKED GOOD.
- 29 Oct 2014
Propeller, failed
ENROUTE, CREW NOTICED BURNING ODOR. ISOLATED TO NR 1 BLEED. SELECTED BLEEDS OFF, ODOR DISSIPATED. ON GROUND WITH POWER LEVERS ADVANCED AND LP BLEEDS…
- 23 Oct 2014
Propeller, failed
NR 1 PROPELLER VIBRATION, RETURN TO FIELD. OIL LEAKING ON GROUND. CREW REPORTED BLADE NOT STRAIGHT. R & R THE NR 1 PROPELLER
- 9 Jul 2014
Bulb, inoperative
EMERGENCY EXIT SIGN LIGHTS ARE INOPERATIVE ON UPPER HALF. R & R BULBS IN EMERGENCY EXIT SIGNS UPPER HALF. OPS CHECKED GOOD.
- 4 Jun 2014
Bulb, inoperative
EMERGENCY CEILING LIGHT IS INOPERATIVE AT ROW 13, ROW 9 AND ROW 1. R & R BULBS. OPS CHECKED GOOD.
- 4 Jun 2014
Bulb, dim
LEFT AFT EXTERIOR EMERGENCY LIGHT IS DIM. R & R BULB, OPS CHECKED GOOD.
- 27 May 2014
Bulb, inoperative
FLOOR EMERGENCY LIGHT IS INOPERATIVE AT ROW 7. R & R BULB. OPS CHECKED GOOD.
- 9 May 2014
Line, leaking
WITH NR 2 ENGINE RUNNING AT FLT IDLE AND START FEATHER BLEEDS ON IN AUTO SET AT MAX AFTER 3-4 MINS STRONG ODOR IN MID TO AFT CABIN. PAX COMPLAINED AND…
- 14 Apr 2014
Bulb, dim
LOWER SIDEWALL EMERGENCY LIGHT IS DIM AT ROW 11DF. R & R BULBS IN LOWER SIDEWALL EMERGENCY LIGHT. OPS CHECKED GOOD.
- 5 Feb 2014
Bulb, inoperative
EMERGENCY LIGHTS ARE INOPERATIVE AT ROW 4. R & R BULBS, OPS CHECKED GOOD.
- 16 Dec 2013
Bulb, inoperative
RIGHT SIDE, REAR FUSELAGE EMERGENCY LIGHT IS DIM. R & R BULB. OP CHECKED GOOD.
- 15 Nov 2013
Longeron, cracked
UPPER INBD LEFT LONGERON IS CRACKED ON OUTER RADIUS. REPAIRED DAMAGE IAW EO8-54-13-0664.
- 30 Sep 2013
Actuator, failed
BETA WARNING HORN SOUNDED AFTER TAKEOFF AT APPROX 50 FT AND SOUNDED CONTINUOUSLY UNTIL 50 FT ON APPROACH. R & R BAD ROLLER ACTUATOR AT SWITCH IAW MM 31-51-02…
- 14 Aug 2013
Warning Horn, activated
TAKEOFF WARNING SOUNDED DURING TAKEOFF ROLL. CONFIGURED ACFT SETTING, NO FIX. GROUND RAN ACFT AND CYCLED ALL RELATED ITEMS. COULD NOT DUPLICATE AT THIS TIME.
- 5 Jul 2013
Radar, malfunctioned
ACT WEATHER RADAR DISPLAYS RED DURING TURNS AND SPIKES IN LEVEL FLIGHT. R & R RADAR RT. OPS CHECKED GOOD. OK FOR SERVICE.
- 27 May 2013
Windshield, damaged
F/O WINDSHIELD TERMINAL HAD SMOKE WITH WINDSHIELD HEAT APPLIED. R & R F/O WINDSHIELD IAW 56-00-00R. OPS AND LEAKED CHECKED GOOD.
- 21 May 2013
Bulb, inoperative
RED EMERGENCY FLOOR PATH LIGHT IS INOPERATIVE AT ROW 11D. REPLACED BULB AT ROW 11D IAW AMM. OPS CHECKED GOOD.
- 17 May 2013
Frame, cracked
CRACK FOUND ON FRAME IN CABIN UNDERFLOOR AT BS 251, BETWEEN S33-32S. REPAIRED IAW RD8-53-4811. COMPLIED WITH HFEC INSPECTION. NO OTHER DEFECTS FOUND.
- 17 May 2013
Plate, cracked
LADDER PLATE FOUND CRACKED UNDER STRESS PANEL 622AT. CUTOUT DAMAGE IAW RD8-57-2387 AND FABRICATED NEW PART IAW RD8-57-2387. HFEC INSPECTION DONE ON REPAIRED…
- 17 May 2013
Bracket, broken
RT WING, FRONT SPAR, LOWER SPAR CAP BRACKET FOUND BROKEN. R & R BRACKET IAW SRM 51-42-10.
- 17 May 2013
Stringer, corroded
CORROSION FOUND UNDER STRINGER 31P AT BS 107. R & R STRINGER IAW RD8-53-1243 AND EO8-53-13-0264.
- 16 May 2013
Frame, corroded
SURFACE CORROSION AND CRACK FOUND ON FRAME AT BS 503.80, STR 31S. CLEANED CORROSION, REPAIRED FRAME MEMBER. HFEC INSPECTION WAS COMPLIED WITH. NO CRACK FOUND.…
- 16 May 2013
Angle, corroded
AFT SERVICE DOOR LOWER SILL ANGLE FOUND CORRODED. R & R SERVICE DOOR THRESHOLD PLATE IAW SRM 51-42-05 AND SRM 51-42-45. DIAPHRAGM AND LOWER SILL ANGLE…
- 16 May 2013
Seat Track, corroded
CORROSION FOUND ON LT AND RT OTBD SEAT TRACK AT BS 196 - 607. BLENDED LT AND RT OTBD SEAT TRACK IAW RD8-53-8319 & RD8-53-3644.
- 16 May 2013
Cargo Track, corroded
CORROSION FOUND ON CARGO TRACK INBD SIDE FROM BS 588 - 660. BLENDED CORROSION, HFEC INSPECTION COMPLIED WITH. NO DEFECTS FOUND.
- 16 May 2013
Flap Track, rusted
LT NR 3 FLAP TRACK MATING SURFACE IS RUSTED. R & R FLAP TRACK IAW AMM 57-50-26.
- 16 May 2013
Floor Support, corroded
SURFACE CORROSION FOUND UNDERFLOOR BETWEEN BS 543 - 572, S31-33S. BLENDED SURFACE IAW SRM 51-00-16.
- 16 May 2013
Flap Track, corroded
LT NR1 FLAP TRACK MATING SURFACE IS RUSTED. R & R NR 1 FLAP TRACK IAW MM 57-50-11.
- 16 May 2013
Flap Track, corroded
RIGHT NR 3 FLAP TRACK MATING SURFACE IS RUSTED. R & R NR 3 RT FLAP TRACK IAW RD8-57-5933 AND MM 57-50-26.
- 16 May 2013
Flap Track, rusted
RT WING FLAP TRACK NR 2 MATING SURFACE IS RUSTED. R & R NR 2 FLAP TRACK IAW MM 57-50-26.
- 16 May 2013
Hinge, corroded
RT INBD ELEVATOR ARM ASSY BEARING BORE IS CORRODED. R & R RT INBD ELEVATOR HINGE ARM ASSEMBLY IAW SRM 51-40-10, SRM 51-42-05 AND SRM 51-42-45.
- 16 May 2013
Hinge, corroded
FORE RUDDER MIDDLE HINGE, LOWER FITTING BEARING RACE IS CORRODED. BLENDED LOWER FITTING BEARING BORE MAIN HINGE FITTING IAW EO8-55-13-0228.
- 6 May 2013
Bracket, cracked
LEFT ENGINE INBD COWLING GENERATOR INTAKE DUCK BRACKET CRACKED. LEFT ENGINE INBD COWLING GENERATOR INTAKE DUCT BRACKET WELDED IAW RD8-71-969 AND EAO5-2013-019.
- 26 Apr 2013
Skin, damaged
RT NACELLE SKIN AT INBD AFT CORNER OF MLG DOOR AFT HINGE ARM. CUTOUT DONE ON RT NACELLE SKIN AT INBD AFT CORNER OF FWD MLG DOOR AFT HINGE ARM IAW RD8-54-892.…
- 25 Mar 2013
Control Cable, frayed
AILERON CABLE FOUND UNSERVICEABLE ON LT WING T/E, ONLY ONE STRAND WAS REMAINING. OPEN
- 17 Mar 2013
Wire, broken
INOP EMERGENCY PATH FLOOR LIGHT AT ROW 12. FOUND LAMP ASSY WIRES BROKEN. R & R LAMP ASSY AND SPLICED WIRES ONE AT A TIME IAW STANDARD PRACTICES. OPS CK GOOD,…
- 8 Jan 2013
Wire, shorted
WITH OVERHEAD AND SIDEWALL LIGHTS OFF. PSU AT ROW 3DF FLICKERING WITH ELECTRICAL ODOR. INSPECTED AREA, FOUND TWO GROUND WIRES DISCONNECTED. CONNECTED WIRES…
- 26 Nov 2012
Bulb, failed
ROW 11, FLOOR EMERGENCY LIGHT IS INOP. REMOVED LENS, REMOVED RED FILTER, R & R BULB. INSTALLED FILTER AND LENS. OPS CHEKCED GOOD.
- 14 Sep 2012
Element, arced
PILOTS SIDE WINDOW HEATING ELEMENT BURNED AND ARCING. R & R CAPTS SIDE WINDOW AND INSPECTED WIRES FOR DAMAGE. NO DAMAGE TO THE WIRING WAS FOUND. OPS AND LEAK…
- 3 Sep 2012
Bulb, failed
TWO RED EMERGENCY PATH LIGHTS AT FORWARD EMERGENCY EXIT ARE INOPERATIVE. R & R 2 RED EMERGENCY PATH LIGHT AT FORWARD EMERGENCY EXIT. OPS CHECKED GOOD.
- 27 Aug 2012
Bulb, failed
EMERGENCY OVERHEAD LIGHT AT ROW 7 IS INOPERATIVE. R & R BULB FOR EMERGENCY OVERHEAD LIGHT AT ROW 7 AND SECURED LENS.
- 11 Aug 2012
Lamp, inoperative
EMERGENCY FLOOR PATH LIGHT INOPERATIVE ROW 1. R AND R EMERGENCY FLOOR PATH LIGHT IN ROW 1, VERY FIRST ONE FORWARD, REPLACED TRACK, OPS CHECKED GOOD.
- 11 Jul 2012
Eec, failed
NR 1 ECU FAILED DURING CLIMBOUT. R & R NR 1 EEC IAW MM 72-01-10. GROUND RAN AIRCRAFT. OPS CHECKED GOOD IAW -8 RUN UP MANUAL.
- 10 Jul 2012
Apu, inoperative
APU WILL NOT START. APU CAUTION LIGHT ILLUMINATED AND CHECK FIRE DETECT WARNING LIGHTS ILLUMINATED. BOTH LIGHTS EXTINGUISHED WHEN APU PANEL WAS SELECTED OFF.…
- 30 Mar 2012
Bulb, inoperative
EMERGENCY FLOOR LIGHT INOPERATIVE AT ROW 8. R & R BULB AT ROW 8, OPS CHECKED GOOD.
- 19 Mar 2012
Structure, damaged
STATIC WICK BASE IS OUT OF LIMITS ON RUDDER, SECOND FROM BOTTOM. REMOVED PAINT AND PRIMER FROM BASE, REINSTALLED STATIC WICK AS REQUIRED.
- 19 Mar 2012
Structure, broken
INBD STATIC WICK BASE HAS WICK BROKEN INSIDE. REMOVED STATIC WICK, INSTALLED NEW STATIC. WICK BASE READS .11 MIL OHMS AND STATIC WICK READS 40 MEGA OHMS.
- 16 Mar 2012
Generator, malfunctioned
NR 1 DC GENERATOR KICKED OFF LINE. CYCLED AND RESET NR 1 DC GENERATOR, POSSIBLE LIGHTNING STRIKE IN FLIGHT. INSPECTED ACFT IAW AMM 05-50-31. NO LIGHTNING…
- 8 Feb 2012
Dadc, failed
ON TAKE, MESSAGE ON 802 DADC DATA INVALID MESSAGE ON APPROACH F/O ALT FLAGGED. PERFORMED ALTITUDE CORRELLATION CHECK DUE TO NR 2 DADC REMOVAL AND REPLACEDMENT…
- 9 Dec 2011
Bulb, failed
ROW 11DF EMERGENCY LIGHT INOPERATIVE. R & R BULB. OPS CHECKED GOOD.
- 14 Nov 2011
Bulb, failed
FLOOR EMERGENCY LIGHT INOPERATIVE BETWEEN ROW 9 AND 10. R & R EMERGENCY LIGHT BULB ON FLOOR BETWEEN ROWS 9 AND 10. OPS CHECKED GOOD.
- 14 Nov 2011
Bulb, failed
FLOOR LEVEL EMERGENCY EXIT SIGN AT PAX DOOR HAS ONE BULB INOPERATIVE. R & R BULB FOR FLOOR LEVEL EMERGENCY EXIT SIGN AT PAX DOOR.
- 15 May 2011
Landing Gear, malfunctioned
AFTER GEAR RETRACTION, NOSE GEAR DOORS OPENED AND NOSE GEAR PARTICAIALLY EXTENDED AND RETRACTED TWICE WITH ALL ASSOCIATED LIGHTS. JACKED ACFT AND PERFORMED…
- 26 Mar 2011
Connector, broken
ELECTRIC ODOR IN CABIN, STRONGEST AT ROW 4-5. FOUND OVERHEAD LIGHT CONNECTORS BROKEN AND MELTED ON RT SIDE OF CABIN AT ROW 3DF. PERFORMED HIDDEN DAMAGE INSP…
- 4 Mar 2011
Light, inoperative
ROW 4, EMERGENCY FLOOR PATH LIGHT INOP. R & R ROW 4 EMERGENCY FLOOR PATH LIGHT, OPS CHECKED GOOD.
- 3 Feb 2011
Light, missing
EMERGENCY FLOOR LIGHT COUNT 28 MISSING 1 LIGHT SOMEWHERE. 1 AFT FOUND UNDER FLOOR AT ROW 13. SECURED PANEL AND INSTALLED CARPET AND LIGHT COVER.
- 3 Feb 2011
Wire, broken
2ND LAST EMERGENCY FLOOR LIGHT HAS A BROKEN WIRE. R & R EMERGENCY FLOOR LIGHT.
- 19 Nov 2010
Bulb, burned out
EMERGENCY FLOOR LIGHT AT ROW 4 INOP. R & R BULB AN ROW 4 EMERGENCY PATH FLOOR LIGHT. OPS CHECKED GOOD.
- 5 Sep 2010
Lamp, inoperative
FLOOR LEVEL EMERGENCY LIGHT AT ROW 2 AND 8 ARE INOP. RELAMPED FLOOR LEVEL EMERGENCY LIGHTS AT ROW 2 AND 8. OPS CHECKED GOOD.
- 8 May 2010
Pipe, loose
BURNING/HOT SMELL IN MID CABIN. REMOVED LT BLEED PIPE FROM WING ROOT TO Y IN CTR OF WING. INSTALLED LT BLEED PIPE FROM WING ROOT TO Y IN CTR OF WING. OPS CKD…
- 2 May 2010
Check Valve, leaking
VERY STRONG ODOR IN PASSENGER COMPARTMENT FROM MIDSECTION GOING AFT. FOUND BLEED AIR LEAK AT RT ENGINE CHECK VALVE IN BLEED AIR DUCT. REPLACED GASKETS AT REAR…
- 1 May 2010
Bulb, inoperative
STRONG ELECTRICAL ODOR TOWARD REAR OF ACFT. REPLACED BULB IN SIDEWALL AT ROW 13AC. INSPECTED SOCKETS WITH NO DEFECTS NOTED. OPS CHECKED GOOD.
- 13 Feb 2010
Lamp, inoperative
EMERGENCY FLOOR PATH LIGHT IS NOT WORKING AT SEAT 2DF. REMOVED AND REPLACED LAMP IAW 33-20-00. CHECKED GOOD.
- 12 Oct 2009
Garlock Seal, leaking
NR 2 ENGINE PRESSURE FLUX BETWEEN 50-55 PSI, THEN WENT TO 35-40 PSI WITH LOW WARNING LIGHT. ENGINE MANUAL SHUTDOWN. OIL PRESSURE NEVER REACHED O PSI RAN…
- 7 Jun 2009
Indicator, broken
ACFT 327 EN PUSHED OFF FROM THE GATE AND TAXIED TO THE RUNWAY FOR TAKE OFF. AT THAT TIME THE NR 1 HYD PRESSURE INDICATOR WAS READING ZERO PSI. FLIGHT 4645…
- 7 Jun 2009
Wire, broken
NR 2 ENGINE HYD CAUTION LIGHT ILLUMINATED FOR APROX 30 SECONDS THEN EXTINGUISHED FOLLOWED BY NR 2 MAIN HYD PRESSURE GOING TO 0 PSI. FOUND BROKEN WIRE AT…
- 13 May 2009
Hydraulic System, low
NR 1 HYD QUANTY DROPPED TO 1 QUANTY AND ISOLATION VALVE CAUTION LIGHT ILLUMINATED. INSPECT ACFT FOR HYD LEAKS, BELLY, TAIL, UNDER WING, OVER CTR FUSELAGE BOTH…
- 23 Jan 2009
Battery, discharged
FWD 2 MID CABIN CEILING LIGHTS ARE INOP. R&R EMERGENCY LIGHT BATTERY AT ROW 3 LT LOCATION IAW 33-51-00. OPS CHECK GOOD.
- 22 Oct 2008
Skin, damaged
DURING 'C' CHECK INSPECTIONS, A REPAIR WITH NO DOCUMENTATION WAS FOUND ON THE FUSELAGE SKIN ON THE FORWARD BELLY AREA, LOCATED AT X231 TO X238 BETWEEN…
- 22 Oct 2008
Skin, damaged
DURING 'C' CHECK INSPECTIONS, A REPAIR WITH NO DOCUMENTATION WAS FOUND ON THE FORWARD FUSELAGE BELLY SKIN AT X225 TO X230 BETWEEN STRINGERS 28P AND 29P. THE…
- 22 Oct 2008
Skin, damaged
DURING 'C' CHECK INSPECTIONS, A REPAIR WITH NO DOCUMENTATION WAS FOUND ON THE FUSELAGE BELLY SKIN AT X198 BETWEEN STRINGERS 30P AND 32P. THIS PATCH WAS R&R…
- 22 Oct 2008
Skin, damaged
DURING 'C' CHECK INSPECTIONS, A REPAIR WITH NO DOCUMENTATION WAS FOUND ON THE FUSELAGE BELLY SKIN AT X210 TO X221 BETWEEN STRINGERS 29P TO 32P. DOCUMENTATION…
- 22 Oct 2008
Floorbeam, damaged
FLOOR BEAM DAMAGE AT STA X129 BENEATH RT INBD SEAT RAIL ATTACHMENT. PERFORM LIQUID PENETRANT INSPECTION PER EO8-53-08-337 NO DEFECT FOUND. REPAIR DAMAGE PART…
- 22 Oct 2008
Skin Panel, dented
2 PROTRUDING DENTS BETWEEN STATION X179-X199 STRINGER 29P-30P. REPAIRED DAMAGE IAW RD8-53-2181.
- 17 Oct 2008
Skin, corroded
CORROSION FOUND ON LOWER SKIN OF THE RT WING BETWEEN STA 130.0 TO 145 AT REAR ON RT WING AT REAR SPAR, LOWER FLAP SHROUD. P/N 85730018-011 R&R IAW STRUCTURAL…
- 16 Oct 2008
Seat Track, corroded
RT INBD SEAT RAIL CORRODED FROM STATION X 423 TO X 588. FABRICATED LT HAND AND RT IAW DRAWING 85331406. USED ON ALODINE SURFACE IAW ESR 07-07-3003.
- 15 Oct 2008
Spar, cracked
SUPECTED CRACK ON LT WING FRONT SPAR AT INBD NACELLE ATTACHMENT TOP CORNER. R&R ANGLE IAW STRUCTURAL REPAIR MANUAL 51-40-00.
- 15 Oct 2008
Skin Panel, corroded
PROTRUDING DENT ON LT FUSE STA X444.8, STR 30P - STR 31P. REPAIR DAMAGE IAW EO8-53-08-3363 EDDY CURRENT AND BONT TEST.
- 15 Oct 2008
Attach Fitting, corroded
CORROSION AROUND 1 FASTENER ON THE REAR SPAR ATTACHMENT TO OTBD NACELLE. REPAIR ATTACHMENT TO OTBD NACELLE WITH HI LOCKS IAW STRUCTURAL REPAIR MANUAL 51-40-00.
- 15 Oct 2008
Skin, dented
PROTRUDING DENT ON BELLY SECTION OF FORWARD FUSELAGE AT STATION X223 BETWEEN STRINGER 32S-33S. REPAIR SKIN IAW RD8-53-2181.
- 17 Sep 2008
Control Valve, broken
NR 1 HYDRAULIC QTY DROPPED TO 1 QUART FOLLOWED BY ISO VALVE CAUTION LIGHT ILLUMINATED. LOST NORMAL BRAKES. R&R NR 2 ANTI-SKID CONTROL VALVE. IAW 32-46-11.…
- 7 Jun 2008
Sequence Valve, inoperative
ON CLIMBOUT NOSE GEAR DOOR ADVISORY LIGHT ILLUMINATED ALONG WITH LOUD NOISE FROM NOSE GEAR AREA. LIGHT WENT OUT AND THEN SAME PROBLEM REOCCURRED. GEAR…
- 7 Jun 2008
Relay, defective
UPON LANDING GEAR RETRACTION NOSE RED UNSAFE LIGHT ILLUMINATED ALONG WITH TRANSIT LIGHT IN HANDLE AND AMBER NOSE GEAR DOOR LIGHTS. NOSE GEAR RETRACTED AND…
- 6 Jun 2008
Transceiver, malfunctioned
LOG PAGE 271884, SEQ NR 1- RADAR ONLY PAINTS 2 RED SPOKES. REMOVED AND REPLACED RT IAW 34-41-01. OPS CHECK GOOD. (K)
- 31 May 2008
Ballast, burned
STRONG ELECTRICAL ODOR WHEN OVERHEAD LIGHT SELECTED ON, AT ROWS 9 THRU 11. INSPECTED AND FOUND ODOR COMES FROM ROW 9/10 AC OVERHEAD BULBS. REMOVED BOTH BULBS…
- 27 Mar 2008
Light, inoperative
WHITE LOW LEVEL EMERGENCY LIGHT AT ROW 7 INOP. RELAMPED WHITE LOW LEVEL EMERGENCY LIGHT AT ROW 7, OPS CHECKED GOOD.
- 7 Mar 2008
Radome, damaged
ENCOUNTERED LIGHTNING STRIKE, INFLIGHT SYSTEM CHECK GOOD. INSPECTED AIRCRAFT, EVIDENCE OF BURN MARKS ON RIGHT HAND SIDE OF RADOME, WILL FERRY AIRCRAFT TO ROA.…
- 17 Dec 2007
Ballast, defective
ELECTRICAL SMELL IN CABIN, MORE NOTICEABLE AT ROW 7. PERFORMED HIDDEN DAMAGE INSPECTION, FOUND OVERHEAD LIGHT ASSEMBLY AT 7C BURNT. REPLACED LAMP HOLDER…
- 21 Sep 2007
Psu, hot
BURNING ODOR AT AFT CABIN, NOTICED BY CREW MEMBERS & AFT F/A CONTROL PANEL APPEARS TO BE HOT TO TOUCH. INSPECTED F/A PANEL NO DEFECT NOTED CREW GROUND RAN…
- 20 Jun 2007
Flex Line, leaking
NR 1 HYD QTY DROPPED TO 1.3, SYSTEM WENT INTO ISO, PRESSURE REMAINED GOOD AND FLUID DRIPPING FROM NR 2 NACELLE. INSTALLED TFL AT RT WING I/B SPOILER ACTUATOR…
- 17 Mar 2007
Engine, damaged
AFTER TAKEOFF ON CLIMB OUT AT ABOUT 4 THOUSAND FEET THE NR 2 ENGINE SHUT DOWN. INSPECTED ENGINE AND FOUND TO BE SERVICEABLE. FOUND FOD DAMAGE ON NR 1 ENGINE…
- 15 Feb 2007
Inverter, failed
CREW NOTICED SMOKE COMING OUT OF LEFT DC C/B PANEL. TURNED OFF INVERTER AND SMOKE DISSIPATED. REPLACED PRIMARY INVERTER.
- 10 Jul 2006
Odor, detected
STRONG ELECTRICAL SMELL IN COCKPIT. FOUND ODOR DISSIPATED UPON ARRIVAL TO AIRCRAFT, INSPECTED AVIONICS RACK, AREA BEHIND WARDROBE WALL, UNDER COCKPIT FLOOR…
- 10 Jul 2006
Odor, detected
STRONG ELECTRICAL ODOR IN COCKPIT. FOUND ODOR DISSIPATED UPON ARRIVAL TO AIRCRAFT, INSPECTED AVIONICS RACK, AREA BEHIND WARDROBE WALL, UNDER COCKPIT FLOOR AND…
- 10 Jul 2006
Terminal Block, overheated
SMOKE IN COCKPIT. FOUND APU STARTER GENERATOR CABLES AT AFT SIDE OF FORWARD PRESSURE BULKHEAD OVERHEATED AT TERMINAL BLOCK 24459-TB1. REMOVED AND REPLACED…
- 18 Jun 2006
Unknown, unknown
ELECTRICAL SMELL IN CABIN. FOUND SIDEWALL LIGHT 8AC INOP. PERFORMED HIDDEN DAMAGE INSPECTION, NO DISCREPANCIES NOTED.
- 18 Jun 2006
Socket, burned
ELECTRICAL SMELL IN CABIN. FOUND LIGHT SOCKET AT 2D BURNED. C/W MP&P VOL 2 33.1
- 31 Aug 2005
Generator, failed
AT APPROXIMATELY 400 FEET ON DEPARTURE, NR 2 AC GEN CAUTION LIGHT ILLUMINATED. APPROXIMATELY ONE MINUTE LATER THE MASTER WARNING AND NR 2 ENGINE OIL PRESSURE…
- 9 Aug 2005
Engine, overtemp
NR 2 ENGINE OIL TEMP WENT INTO RED ON TAKEOFF, REDUCED POWER AND STABILIZED IN YELLOW. REMOVED AND REPLACED THE OIL FUEL HEATER.
- 25 Jun 2004
Pseu, damaged
NOSE GEAR AND NOSE GEAR DOOR ADVISORY LIGHT & GEAR UNSAFE LIGHT CYCLED 4 TIMES WHILE AIRBORNE WITH GEAR HANDLE CYCLED UP. INSPECTED NOSE GEAR SENSORS AND…
- 19 Dec 2003
Actuator, lack of lube
UNABLE TO MOVE ELEVATOR TRIM TO NOSE DOWN POSITION IN FLIGHT , OPS NORMAL ON THE GROUND. LUBED ELEVATOR TRIM ACTUATOR AS REQ, OPS CHECK GOOD.
- 15 Sep 2003
Seat Belt, loose
SEAT BELT AT 10D CAME LOOSE, INSTALLED SEAT BELT HARDWARE, OPS CHECK GOOD.
- 18 Dec 2002
Control Box
Overhead and sidewall emergency lights flickered in flight. R&R of emergency light control box followed by a ground operational check.
- 19 Jan 2002
Pump, failed
NUMBER 1 HYDRAULIC PUMP CAUTION LIGHT ILLUMINATED, QUANTITY GOOD SYSTEM PRESSURE 3000 PSI WITH STANDBY PUMP OFF. NUMBER 1 SYSTEM FAILED IN FLIGHT, SYSTEM…
- 8 Jun 2001
Skin, departed
ON APPROACH AT 200 FEET, CREW AND FLIGHT ATTENDANT HEARD A LOUD BANG FOLLOWED BY AIRFRAME VIBRATION FELT THROUGHOUT THE CABIN AND FLIGHT DECK. FOUND NUMBER…
- 4 Jun 2001
Hydraulic System, overserviced
LOSS OF NR 1 HYDRAULIC SYSTEM FLUID IN FLIGHT. NR 1 HYDRAULIC ISO VALVE LIGHT AND ROLL SPOILER INBOARD LIGHT ILLUMINATED. NR 1 HYDRAULIC SYSTEM DID NOT GO TO…