N318US
2025 Costruzioni Aeronautiche Tecna P2010 TDI standard FAA →
registration
- 2025
earlier registrations
1 past record
- 1991
service difficulty reports
131 reports
- 13 May 2017
Cover, missing
ROW 11 RIGHT EMERGENCY LIGHT COVER MISSING, REPLACED THE COVER.
- 7 Jan 2017
Box Beam, cracked
LEFT SIDE BOX BEAM UPPER FLANGE CRACKED. REPAIRED IAW AMDS 5310-01450-02.
- 26 Oct 2016
Light, damaged
SEAT MOUNTED EMERGENCY LIGHT SEAT 21C DAMAGED, EMERGENCY LIGHT REPAIRED.
- 19 Jan 2016
Stringer, corroded
FOUND EVEDENCE OF CORROSION IN MULTIPLE LOCATIONS ON S42R BETWEEN FRAMES 54 & 58, REMOVED AREAS OF CORROSION REPAIR ON S42R BETWEEN FRAMES 54 & 58 IAW SRM…
- 19 Jan 2016
Stringer, corroded
CORROSION ON STRINGER 44 BETWEEN FRAMES 56 AND 59, REMOVED CORROSION AND INSTALLED REPAIR IAW SRM.
- 16 Jan 2016
Stringer, corroded
FOUND CORROSION ON STRINGER 43L BETWEEN FRAMES 56 AND 57. REMOVED STR 43L BETWEEN FRAME 55 TO 59. INSTALLED NEW STRINGER SECTION IAW SRM 53-00-13.
- 16 Jan 2016
Stringer, corroded
CORROSION ON STRINGER 42L BETWEEN FRAMES 56 AND 57. REMOVED STR 42L BETWEEN FRAMES 55 AND 58. FABRICATED AND INSTALLED STRINGER SECTION AND COUPLING/SPLICE…
- 16 Jan 2016
Frame, corroded
CORROSION ON FRAME 43L AT FRAME 55. REPAIR THE FRAME.
- 25 Feb 2015
Wire, pulled
DURING NON-ROUTINE CHECK, FOUND EMERGENCY LIGHT AT SEAT 12 INOPERATIVE. FOUND POWER WIRE PULLED FROM SPLICE. REINSTALLED WIRE TO SPLICE AND FUNCTIONAL CHECK…
- 25 Feb 2015
Wire, broken
DURING NON ROUTINE CHECK, FOUND EMERGENCY LIGHT AT SEAT 9 IS INOPERATIVE. FOUND BROKEN GROUND WIRE AT SPLICE. REPLACED SPLICE AND FUNCTIONAL CHECK WAS NORMAL.
- 21 Feb 2014
Power Supply, inoperative
DURING NON-ROUTINE CHECK, FOUND SEVERAL SEAT EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE REPLACED EPSU AND FUNCTIONAL CHECKED NORMAL.
- 3 Dec 2013
Connector, unsecure
DURING NON ROUTINE CHECK, FOUND EMERGENCY LIGHT SYSTEM TEST FAILED. MAINTENANCE FOUND EMERGENCY ESCAPE PATH LIGHTING AT SEATS 9C, 16C, 17C, 21C, 22C, 23C,…
- 20 Oct 2013
Relay, malfunctioned
DOOR LIGHTS ON AFTER GEAR UP. CABIN LIGHT UNCONTROLLABLE FROM F/A PANEL. R & R RELAY 8WL IAW ASM 33-51. OPS TESTED GOOD, OK FOR CONTINUED SERVICE.
- 28 Jun 2013
Profile, cracked
DURING INSPECTION, FOUND LT FWD EMERGENCY EXIT DOOR LT LOAD TRANSMITTING PROFILE HAS CRACK. HFEC IAW NTM 51-10-08 PT6, CONFIRMED CRACK BY FASTENER HOLE.…
- 28 Jun 2013
Plate, chafed
DURING INSPECTION, FOUND LT NR 3 SLAT TRACK COVER PLATE CHAFING W/ SLAT T/E LWR SKIN. ACCOMPLISHED REPAIR IAW ER/A 494603-14MA, SECTION 1, PERMANENT REPAIR…
- 28 Jun 2013
Attach Fitting, corroded
DURING INSPECTION, FOUND LT FWD EMERGENCY EXIT DOOR LWR AFT LATCH HOOK ATTACH FITTING HAS CORROSION. REMOVED OLD FITTING IAW SRM 51-42-11. LOCATED AND DRILLED…
- 28 Jun 2013
Profile, cracked
DURING INSPECTION, FOUND RT FWD EMERGENCY EXIT DOOR LT LOAD TRANSMITTING PROFILE HAS SEVERAL CRACKS AROUND FASTENER HOLES. HFEC IAW NTM 51-10-08, PT6,…
- 27 Jun 2013
Floor Support, cracked
DURING INSPECTION, FOUND COCKPIT FLOOR SUPPORT RT SIDE FWD FR8 Y-1292, AROUND NUTPLATE SHEETMETAL CRACKED. ACCOMPLISHED REPAIR IAW ER/A 515379-14, REV…
- 24 Jun 2013
Floorbeam, corroded
DURING INSPECTION, FOUND AFT CARGO FLOORBEAM AT FR58, LT SIDE, FWD FACE HAS 2EA AREAS OF CORROSION. REMOVED FLOORBEAM AT FR 58 IAW SRM 51-42-11. NO ALLOWABLE…
- 24 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND AFT CARGO SLOPE PANEL 162CF DELAMINATED 21" X 15". AFT CARGO COMPARTMENT SLOPE PANEL FABRICATED IAW SRM 53-02-00, FIG 209.
- 24 Jun 2013
Floor Panel, damaged
MID CABIN, FLOOR PANEL 241AF FOUND ONE ELONGATED HOLE AND CRACKED. FABRICATED NEW FLOOR PANEL IAW AMM 25-50-00-340-007-A.
- 24 Jun 2013
Floor Support, corroded
DURING INSPECTION, FOUND AFT CARGO BETWEEN FR 58-59, STR 44, FLOOR SUPPORT HAS SURFACE CORROSION. BLENDED CORROSION. BLENDED CORROSION IAW SRM 51-74-00. NO…
- 23 Jun 2013
Skin, damaged
DURING INSPECTION, FOUND AFT LT PASSENGER DOOR EXTERNAL FROM LOWER EDGE TO ABOVE 16 INCHES SKIN HAS DENT. FOUND OUT OF LIMITS IAW SRM 52-10-00, DIAGRAM 103.…
- 22 Jun 2013
Stringer, corroded
DURING INSPECTION, FOUND AFT CARGO COMPARTMENT BETWEEN FR56-FR57, STR 43L CORRODED. CLEANED AREA IAW AMM 12-21-12. CORROSION FOUND. NO LIMITS ESTABLISHED IAW…
- 21 Jun 2013
Shear Tie, corroded
DURING INSPECTION, FOUND FWD CARGO COMPT BILGE AREA AT FR 28 STGR 41R -42R CLIP HAS CORROSION. REMOVED SHEAR CLIP IAW SRM 51-42-11. NO ALLOWABLE DAMAGE LIMITS…
- 21 Jun 2013
Stringer, damaged
DURING INSPECTION, FOUND AFT CARGO AT FR 65, STR 43L HAS CORROSION. REMOVED CORROSION IAW SRM A320 51-74-00. NO ALLOWABLE DAMAGE FOUND ON SRM. PERFORMED…
- 19 Jun 2013
Stringer, corroded
DURING INSPECTION, FOUND AFT CARGO BAY FR58 - 59 S42L CORRODED. CLEANED AREA IAW AMM 12-21-12. NO LIMITS ON CORROSION ESTABLISHED IAW SRM 53-41-13, FIG 101.…
- 19 Jun 2013
Stringer, corroded
DURING INSPECTION, FOUND FWD CARGO BAY, FR 33-34, S41L CORRODED. BLENDED CORROSION IAW SRM 51-74-00 CHECKED LIMITS, WITH NO ALLOWABLE DAMAGE FOUND ON SRM. CUT…
- 17 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151QF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 17 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 152BF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-37705.
- 17 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151AF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00 FIG 209 & DWG 3D25-37705.
- 17 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151LF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-37705.
- 17 Jun 2013
Floor Panel, damaged
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151DF HAS SEVERAL BROKEN EDGES & DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 17 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 152EF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 17 Jun 2013
Angle, cracked
DURING INSPECTION, FOUND RT AFT EMERGENCY EXIT DOOR LT LOAD TRANSMITTING PROFILE HAS SEVERAL CRACKS AROUND FASTENER. HFEC IAW NTM 51-10-08, PT6 CONFIRMED…
- 16 Jun 2013
Floor Panel, damaged
DURING INSPECTION, FOUND FORWARD CARGO FLOOR PANEL 132KF DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 16 Jun 2013
Floor Panel, damaged
DURING INSPECTION, FOUND FORWARD CARGO FLOOR PANEL 131JF DELAMINATED AND DAMAGED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 16 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND FWD CARGO FLOOR PANEL 131HF DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 16 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND FWD CARGO FLOOR PANEL 131AF DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 16 Jun 2013
Floor Panel, damaged
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151GF HAS SEVERAL BROKEN INSERTS & DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 16 Jun 2013
Floor Panel, punctured
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 162FF HAS PUNCTURED & DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 16 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151FF DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 16 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 161CF DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 16 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 161EF DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 16 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 161FF DELAMINATED. FABRICATED FLOOR PANEL IAW BFM 53-02-00, FIG 209.
- 16 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151EF DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 16 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 161BF DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 16 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 152RF DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 16 Jun 2013
Panel, delaminated
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 152MF DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 16 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151CF DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 16 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151JF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 16 Jun 2013
Floor Panel, punctured
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151HF HAS SEVERAL PUNCTURES & DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 16 Jun 2013
Floor Panel, punctured
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151NF HAS SEVERAL PUNCTURED & DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 13 Jun 2013
Floor Panel, corroded
DURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261FF HAS CORROSION. REPLACED FLOOR PANEL IAW SRM 51-72-11.
- 12 Jun 2013
Floorboard, damaged
DURING INSPECTION, FOUND MAIN CABIN FLOORBOARD 251AF IS DAMAGED, L=84 W=20. FABRICATED NEW FLOORBOARD IAW SRM 53-02-00.
- 12 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND MID CABIN FLOOR PANEL 251YF DELAMINATED 1" X 24". FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-37498.
- 12 Jun 2013
Floorboard, damaged
DURIING INSPECTION, FOUND MAIN CABIN FLOORBOARD 251JF IS DAMAGED, W=18 L=63. FLOORBOARD FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-37498.
- 12 Jun 2013
Floorboard, damaged
DURING INSPECTION, FOUND MAIN CABIN FLOORBOARD 251MF IS DAMAGED, L=84, W=20. FLOORBOARD FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-37498.
- 12 Jun 2013
Floor Panel, damaged
DURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261PF SEVERAL INSERTS MISSING & BROKEN. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-37498.
- 12 Jun 2013
Floor Panel, punctured
DURING INSPECTION, FOUND FWD UTILITY FLOOR PANEL 222CF PUNCTURED 1" X 1". FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-37498.
- 12 Jun 2013
Floorboard, broken
DURING INSPECTION, FOUND FWD UTILITY FLOORBOARD 221DF SEVERAL INSERTS BROKEN & MISSING. FLOORBOARD FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-37498.
- 12 Jun 2013
Floor Panel, delaminated
DURING INSPECTION, FOUND MID CABIN FLOOR PANEL 252FF DELAMINATED 1" X 24". FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-37498.
- 11 Jun 2013
Floor Panel, damaged
DURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 262EF SEVERAL INSERT MISSING & BROKEN. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00.
- 11 Jun 2013
Floor Panel, punctured
DURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261EF PUNCTURED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00.
- 11 Jun 2013
Floor Panel, broken
DURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261DF SEVERAL INSERTS MISSING & BROKEN. FABRICATED NEW FLOOR PANEL IAW SRM 53-02- 00.
- 11 Jun 2013
Floorbeam, cracked
DURING INSPECTION, FOUND FWD CABIN FLOORBEAM AT AFT FR24, Y254 UPPER FLANGE CRACKED. NO LIMITS FOUND ON CRACKED FLANGE IAW SRM 53-00-14. REMOVED DAMAGED AREA…
- 11 Jun 2013
Floor Panel, corroded
DURING INSPECTION, FOUND AFT CARGO COMPARTMENT THRESHOLD FLOOR PANEL 152KF CORRODED ON SEVERAL AREAS L=6" W=3" D=.030". FLOOR PANEL INSTALLED.
- 10 Jun 2013
Floor Support, damaged
DURING INSPECTION, FOUND MID CABIN FLOOR SUPPORT BETWEEN FR 32 AND FR 33 AT -Y245 UPPER FLANGE DAMAGED. BLENDED AREA IAW SRM 51-73-00, FOUND TO BE OUT OF…
- 10 Jun 2013
Floor Support, corroded
DURING INSPECTION, FOUND FWD CABIN FLOOR SUPPORT RT SIDE FR20, S23R UPPER FLANGE WEB AND ANGLE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. NOT…
- 10 Jun 2013
Floor Panel, corroded
DURING INSPECTION, FOUND FWD UTILITY FLOOR PANEL 221FF HAS CORROSION. NEW FLOOR PANEL INSTALLED.
- 10 Jun 2013
Web, cracked
DURING INSPECTION, FOUND COCKPIT FLOOR STRUCTURE RT SIDE AT FWD FR11 Y-765 LOWER CORNER WEB CRACKED. REMOVED CRACK IAW SRM 51-42-11. LOCATED AND DRILLED NEW…
- 10 Jun 2013
Bolt, scored
DURING INSPECTION, FOUND RT WING AILERON NR 1 HINGE PIN (BOLT) SCORED. RECEIVED 1 EA BOLT, PN D5755103720051 TO BE INSTALLED ON AMDS CARD 5760-1010S-RT. WEAR…
- 8 Jun 2013
Floor Support, corroded
DURING INSPECTION, FOUND FORWARD CABIN UTILITY AREA FLOOR SUPPORT, BETWEEN FR12-FR20 Y-254 UPPER FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00,…
- 8 Jun 2013
Floor Support, corroded
DURING INSPECTION, FOUND AFT CABIN UTILITY AREA FLOOR SUPPORT BETWEEN FR66-68 Y1292, UPPER FLANGE, NUTPLATES & HOLES HAS CORROSION. REMOVED CORROSION IAW SRM…
- 8 Jun 2013
Floorbeam, corroded
DURING INSPECTION, FOUND AFT CABIN UTILITY AREA FLOOR SUPPORT BETWEEN FR 68-69, Y1292 HARD PT. HOLES & UPPER FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM…
- 8 Jun 2013
Floor Support, corroded
DURING INSPECTION, FOUND AFT CABIN UTILITY AREA FLOOR SUPPORT BETWEEN FR 65-66, Y1292. UPPER SURFACE & HARD POINT HOLES HAS CORROSION. REMOVED CORROSION IAW…
- 8 Jun 2013
Floor Panel, corroded
DURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261FF HAS CORROSION. NEW FLOOR PANEL INSTALLED.
- 7 Jun 2013
Beam, corroded
DURING INSPECTION, FOUND LT AFT PASSENGER/CREW DOOR SILL BEAM AT AFT FR66 INBD. AROUND GIRT BAR HOLES HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00…
- 6 Jun 2013
Floor Support, corroded
DURING INSPECTION, FOUND AFT CABIN UTILITY AREA FLOOR SUPPORT BETWEEN FR 68-69, Y-1292 UPPER FLANGES & HARD POINT HOLES HAS CORROSION. REMOVED CORROSION IAW…
- 6 Jun 2013
Floor Support, corroded
DURING INSPECTION, FOUND AFT CABIN UTILITY AREA FLOOR SUPPORT BETWEEN FR 65-66 Y-1292, UPPER FLANGES & HOLES HAVE CORROSION. REMOVED CORROSION IAW SRM…
- 6 Jun 2013
Floor Support, corroded
DURING INSPECTION, FOUND AFT CABIN UTILITY AREA FLOOR SUPPORT BETWEEN FR 66-68 Y-1292 UPPER FLANGES, NUTPLATES & HOLES HAS CORROSION. REMOVED CORROSION IAW…
- 6 Jun 2013
Floor Support, corroded
DURING INSPECTION, FOUND AFT CABIN UTILITY AREA FLOOR SUPPORT BETWEEN FR65-FR67, Y-308 UPPER FLANGE HOLES HAS CORROSION. BLENDED AFT CABIN UTILITY AREA FLOOR…
- 6 Jun 2013
Tray, cracked
DURING INSPECTION, FOUND AFT CABIN UTILITY AREA FLOOR SUPPORT TRAY LT SIDE BETWEEN FR68-69, STRG 23L CRACKED. REPLACED FLOOR SUPPORT TRAY IAW SRM 51-42-11,…
- 4 Jun 2013
Floor Support, corroded
DURING INSPECTION, FOUND AFT CABIN UTILITY AREA FLOOR SUPPORT BETWEEN FR65 TO FR67 Y-465 UPPER FLANGE HOLES HAS CORROSION. BLENDED AREA IAW SRM 51-74-00.…
- 31 May 2013
Floor Support, corroded
DURING INSPECTION, FOUND FORWARD CABIN UTILITY AREA FLOOR SUPPORT BETWEEN FR 16 TO FR 24 Y1292 UPPER FLANGE HOLES & SEAT TRACK CROWN AREA HAS CORROSION.…
- 31 May 2013
Sill, corroded
DURING INSPECTION, FOUND AFT LT PASSENGER/CREW DOOR SILL BEAM AT FR 68 AFT CORNER FITTING HAS CORROSION. REPLACED FITTING CORNER IAW SRM 51-42-11. DAMAGE…
- 31 May 2013
Web, cracked
DURING INSPECTION, FOUND COCKPIT FLOOR STRUCTURE LT SIDE AT FWD FR 11, Y765 LOWER CORNER WEB CRACKED. FOUND TO FOUND TO BE OUT OF LIMITS IAW SRM 53-41-14, FIG…
- 30 May 2013
Floor Support, corroded
DURING INSPECTION, FOUND FORWARD CABIN FLOOR SUPPORT BETWEEN FR20 -FR23 Y-189 UPPER FLANGE HAS CORROSION. REPLACED FLOOR SUPPORT IAW SRM 51-42-11 AND DWG.…
- 29 May 2013
Floorbeam, corroded
DURING INSPECTION, FOUND FWD CABIN UTILITY AREA FLOORBEAM BETWEEN FR16 -20, Y254 UPPER FLANGE HAS CORROSION. BLENDED CORROSION IAW SRM 51-74-00 CHECK LIMITS…
- 29 May 2013
Floor Support, corroded
DURING INSPECTION, FOUND FWD CABIN UTILITY AREA FLOOR SUPPORT BETWEEN FR12-FR16, Y503.2 UPPER FLANGE HOLES HAS CORROSION AND SCRIBE LINE MARKS. REMOVED…
- 28 May 2013
Skin, dented
DURING CURRENT M-CHECK, LT SIDE OF FWD FUSELAGE JUST AFT OF FR 21 AT STR 24L, SKIN IS DENTED AND IT WAS REPAIRED IAW SRM 53-11-11, FIG 212. DOUBLER REPAIR…
- 23 Sep 2011
Light, inoperative
DURING A LINE CHECK, MAINTENANCE FOUND THE EMERGENCY PATH LIGHT AT 6C INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. OPERATIONAL CHECK WAS GOOD.
- 27 May 2011
Wire, damaged
DURING EMERGENCY LIGHT TEST FOUND WIRE DAMAGED AT SEAT 5C, REPLACED PATH LIGHT ASSEMBLY AND TESTS OK.
- 17 May 2011
Tee Fitting, damaged
RT WING FWD EMERGENCY AND REPLACED TWO TEE FITTINGS (AFT AND FWD) AT RT WING FWD EMERGENCY DOOR IAW SRM 51-42-11.
- 16 May 2011
Hook, corroded
RT WING AFT EMERGENCY HATCH HAS CORROSION AT LWR T HOOK FITTINGS FWD AND AFT AREA. REMOVED AND REPLACED 2 T FITTING IAW2 SRM 51-42-11 P/N D522790 5420400…
- 16 May 2011
Floor Panel, delaminated
AFT PIT FLOOR PANEL 151PF IS DELAMINATED 4" BY 4" AREA. REMOVED FLT PNL 151PF AT AFT PIT IAW SRM 51-42-11. FABRICATED NEW FLOOR PANEL 151PF ON STAM TRAVELER…
- 16 May 2011
Floor Panel, delaminated
AFT PIT FLOOR PANEL 151LF IS DELAMINATED 4" BY 4" AREA. REMOVED FLOOR PANEL 151LF IAW AMM 53-42-14. FABRICATED NEW FLOOR PANEL 151LF IAW DWG 3D25-37705 ON…
- 16 May 2011
Skin, corroded
AFT FUSELAGE SKIN AROUND VACUUM VENT HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. REMAINING MATERIAL OUT OF LIMITS PER SRM 53-41-11. REMOVED EXISTING…
- 16 May 2011
Skin, damaged
LT SIDE OF AFT FUSELAGE, BELOW L-2 DOOR, JUST FWD OF FR66 AT S27L. REMOVED DOUBLER IAW SRM 51-42-11 CUTOUT DAMAGED AREA IAW SRM 53-41-11. FABRICATED NEW…
- 15 May 2011
Structure, cracked
LT WING FWD EMERGENCY HATCH RT LOAD HAS CRACKS. REMOVED AND INSTALLED NEW LOAD TRANSMITTING PROFILE IAW SRM 51-42-11. PROFILE INST P/N D5227902020511…
- 15 May 2011
Escape Hatch, cracked
RT WING AFT EMERGENCY HATCH RT LOAD TRANSMITTING PROFILE HAS A CRACK (2 PLACES). REMOVED LOAD TRANSMITTING PROFILE PER SRM 51-42-11;LOCATED AND DRILLED NEW…
- 14 May 2011
Floor Panel, punctured
FWD CARGO COMPARTMENT, FLOOR PANEL 131AF HAS DENT AND PUNCTURES. REMOVED FLOOR PANEL 131AF AT FWD COMPT IAW SRM 51-42-11. FABRICATED NEW FLOOR PANEL 131AF ON…
- 14 May 2011
Floor Panel, damaged
FWD CARGO COMPARTMENT, FLOOR PANEL 131EF IS DAMAGE. REMOVED FLOOR PANEL 131EF OF FWD CARGO COMP IAW SRM 51-42-11. FABRICATED NEW FLOOR PANEL 131EF ON STAM…
- 14 May 2011
Floor Panel, delaminated
AFT PIT FLOOR PANEL 161AF IS DELAMINATED. 5" BY 5" REMOVED AFT PIT FLOOR PANEL 161AF IAW AMM 53-42-14. FABRICATED FLOOR PANEL . INSTALLED AFT PIT FLOOR PANEL…
- 14 May 2011
Floor Panel, delaminated
AFT PIT FLOOR PANEL 151DF IS DELAMINATED ON SEVERAL AREAS DIA. 6" BY 6" AREA. REMOVED FLOOR PNL 151DF IN AFT PIT IAW SRM 51-42-11. FABRICATED NEW FLOOR PNL…
- 14 May 2011
Floor Panel, delaminated
AFT PIT FLOOR PANEL 151GF IS DELAMINATED. 8" BY 8" AREA REMOVED FLOOR PANEL 151GF OF AFT PIT IAW SRM 51-42-11. FABRICATED NEW FLOOR PANEL 151GF ON STAM…
- 13 May 2011
Escape Hatch, corroded
LT WING AFT EMERGENCY HATCH HAS CORROSION AT LOWER FWD T HOOK FITTING. REMOVED AND REPLACED T FITTING LT WING AFT EMERGENCY HATCH IAW SRM 51-42-11 T FITTING…
- 8 Dec 2010
Light, inoperative
PILOT REPORTED SEAT 24C EMERGENCY PATH LIGHT OUT, REPLACED LIGHT ASSY AND TESTS OK.
- 3 Dec 2010
Light, no test
DURING EMERGENCY LIGHT TEST, AFT LT SHOWED LOAD FAULT, REPLACED SLIDE 2R AND CHECKED OK. (2010-00905)
- 14 Jan 2007
Hydraulic System, overserviced
PASSENGER AND FLIGHT ATTENDANTS COMPLAINED OF BURNING OIL SMELL ON APPROACH INTO CANCUN. NOTED AS NOT DEICE FLUID AND ALL HYDRAULIC SYSTEMS OVER FULL…
- 3 May 2006
Battery, inoperative
DURING A-CHECK THE PATH LIGHTS INOP AT OVERWING EXIT. REPLACED EPSU 32-3300-4-0073 MFG 100865 AND BATTERY PACK 55-3300-4-0007 MFG 2013-1A.
- 4 Mar 2006
Power Supply, discharged
DURING LINE CHECK, FOUND EMERGENCY LIGHT SYSTEM "TEST OK" LIGHT DID NOT COME ON. REPLACED POWER SUPPLY AND BATTERIES. OPERATIONAL CHECK GOOD. A/C RETURNED TO…
- 29 Mar 2005
Fitting, broken
AFTER TAKEOFF FROM MEM PRIOR TO FLAP RETRACTION, RECEIVED ECAM CAUTION HYD Y RSVR LO LVL. FOLLOWED COM PROCEDURES, RETURNED TO MEM, AND LANDED UNEVENTFULLY.…
- 4 Jan 2001
Roller, out of adj
UPON ARRIVAL AT THE GATE, THE GATE AGENT HAD DIFFICULTY PULLING DOOR 1L OPEN WITHOUT ASSISTANCE BY A FLIGHT ATTENDANT FROM THE AIRCRAFT INTERIOR. MAINTENANCE…
- 2 Feb 2000
Valve, leaking
DURING DESCENT RECEIVED HYD G RSVR LO LEVEL MESSAGE. FOLLOWED COM PROCEDURES AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED LEAKING NOSE LANDING GEAR DOOR…
- 21 Dec 1999
Yaw Damper, leaking
DURING DESCENT, RECEIVED HYD G RSVR LOW LVL ECAM MESSAGE. FOLLOWED COM PROCEDURES AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED LEAKING YAW DAMPER 3CC1.…
- 13 Feb 1998
Uplock, malfunctioned
DURING APPROACH FOLLOWING LANDING GEAR EXTENSION, RIGHT MAIN GEAR DOOR INDICATED OPEN. RECYCLED LANDING GEAR RECEIVED THE SAME INDICAITON AND LANDED WITHOUT…
- 12 Sep 1997
Engine, failed
DURING TAKEOFF, THE NR 1 ENGINE EGT BEGAN TO EXCEED LIMITS. AIRCRAFT RETURNED TO DEPARTURE AIRPORT. MAINTENANCE REMOVED AND REPLACED THE NR 1 ENGINE.
- 21 Aug 1997
Engine, failed
AS THROTTLES WERE ADVANCED FOR TAKEOFF, THE NR 2 ENGINE EXPERIENCED A CONTAINED FAILURE. THE TAKEOFF WAS ABORTED AT 20 KNOTS AND THE CREW FOLLOWED ECHM…
- 26 Jan 1997
Screen, contaminated
AT FL390, THE LEFT WING NR 1 FUEL PUMP LOW PRESSURE LIGHT ILLUMINATED. RESET SWITCH ONCE AND OPERATION WAS SATISFACTORY FOR A SHORT TIME, THEN BOTH LEFT WING…
- 25 Dec 1996
Prox Sensor, malfunctioned
AFTER LANDING GEAR EXTENSION, THE LANDING GEAR DOOR INDICATED OPEN. CYCLED LANDING GEAR HANDLE AND ALL INDICATIONS WERE NORMAL. AIRCRAFT LANDED WITHOUT…
- 25 Oct 1996
Apu, failed
SHORTLY AFTER TAKEOFF, STRONG OIL FUMES WERE DETECTED THROUGHOUT THE AIRCRAFT. AIRCRAFT RETURNED TO MSP. GROUND MAINTENANCE FOUND OIL IN THE APU DUCTS. THE…
- 14 Oct 1996
Skin Valve Ind, malfunctioned
DURING TAKEOFF ROLL, RECEIVED VENT SKIN VALVE FAULT. TAKEOFF WAS ABORTED AND AIRCRAFT RETURNED TO THE GATE. MAINTENANCE TROUBLESHOOTING REVEALED NO…
- 14 Oct 1996
Computer, malfunctioned
AFTER RECEIVING VENT SKIN VALVE FAULT DURING A PREVIOUS TAKEOFF ATTEMPT, RECEIVED THE SAME MESSAGE. TAKEOFF WAS AGAIN ABORTED. THE AIRCRAFT RETURNED TO THE…
- 9 Aug 1996
Interface Unit., failed
DURING APPROACH, THE LANDING GEAR DID NOT EXTEND. CYCLED LANDING GEAR HANDLE AND ALL INDICATIONS WERE NORMAL. AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE…
- 7 Aug 1996
Sensor, malfunctioned
DURING APPROACH AFTER PLACING THE LANDING GEAR HANDLE IN THE DOWN POSITION, THE LANDING GEAR DOORS INDICATED PARTIALLY OPEN. CYCLED LANDING GEAR HANDLE AND…
- 7 Aug 1996
Prox Sensor, malfunctioned
DURING APPROACH AFTER EXTENDING THE LANDING GEAR, RECEIVED 'L/G NOT DOWNLOCKED' MESSAGE WITH NOSE LANDING GEAR INDICATING LOCKED AND THE MAIN LANDING GEAR…
- 4 Aug 1996
Prox Sensor, malfunctioned
DURING APPROACH AFTER LANDING GEAR EXTENSION, RECEIVED L/G GEAR NOT DOWNLOCKED MESSAGE. CYCLED LANDING GEAR AND ALL INDICATIONS WERE NORMAL. AIRCRAFT LANDED…
- 2 Aug 1996
Prox Sensors, dirty
DURING APPROACH AFTER LANDING GEAR EXTENSION, THE GEAR DOORS DID NOT INDICATE CLOSED. CYCLED LANDING GEAR HANDLE AND ALL INDICATIONS WERE NORMAL. AIRCRAFT…
- 18 Jun 1996
Battery, discharged
AFT AISLE EMERGENCY EXIT AND DOOR 4L EMERGENCY EXIT SIGNS INOPERATIVE. REPLACED BATTERY PACK. OPERATIONAL CHECK OK.
- 25 May 1995
Computers, failed