N318DL
1984 Boeing 737-232 standard FAA →
earlier registrations
1 past record
- 1984
service difficulty reports
27 reports
- 14 Aug 2005
Charger, inoperative
EMERGENCY LIGHTS ON SEATS WILL NOT EXTINGUISH. REPLACED BATTERY CHARGER IN CEILING ABOVE 1C RIGHT AFT CHARGER. SYSTEM TEST NORMAL.
- 20 Sep 2004
Mixing Valve, dirty
CONTROL YOKE HAS DEAD ZONE FEEL PLUS/MINUS SIX DEGREES OF CENTER WITH NO AILERON MOVEMENT. REMOVED DIRT AND DEBRIS FROM AILERON MIXING UNIT.
- 8 Mar 2004
Skin, gouged
THE FUSELAGE SKIN AND UNDERLYING BEARSTRAP WERE FOUND DENTED AND GOUGED AT THE AFT EDGE OF THE C2 DOOR CUTOUT AT STRINGER 22R. THE DAMAGE WAS REMOVED WITH A 1…
- 15 Aug 2003
Accessory Unit, failed
IRR LANDING GEAR LEVER LOCK WOULD NOT RELEASE WHEN GEAR HANDLE WAS RAISED AFTER T/O. REPLACED LANDING GEAR ACCESSORY UNIT.
- 12 Sep 2002
Diaphragm, missing
IRR/ NR 2 ENG HIGH VIBES AT FL 350. FLT DIVERTED TO RDU. VISUAL INSP FOUND EXTENSIVE FAN DAMAGE AND BLUE ICE COMING FROM FWD LAV SVC PANEL AND BLUE STAINS AT…
- 24 Oct 2001
Skin, damaged
DAMAGE TO UPPER SKIN OF AILERON. REPAIRED PER ER/A 410406-14.
- 11 Oct 2001
Skin, damaged
DAMAGE FOUND IN THE L2 DOOR SURROUND BEAR STRAP AT THE UPPER HINGE CUTOUT, THE SKIN IS ALSO DAMAGED AT THIS LOCATION. ER/A 360175-14 REV B.
- 5 Sep 2001
Fitting, worn
SUBJECT FWD ENGINE MOUNT SUPPORT FITTING ASSY WAS FOUND WITH OVERSIZED MOUNT HOLES. REPAIR PER ER/A 410315-14AD.
- 25 May 2000
Indicator, malfunctioned
ON T/O 03 SLAT LED SLAT REMAINED INTRANSIT ON T/O AFTER FLAP RETRACTION. RETURNED TO MCO. ON EXTENSION 02 SLAT REMAINED INTRANSIT. INSPECTED SLATS, RAN SLATS…
- 18 Apr 2000
Power Supply, inoperative
OVERHEAD EMERGENCY LIGHT INOP AT SEAT ROW 6 DEF. REPLACED BATTERY PACK POWER SUPPLY.
- 2 Apr 2000
Light, inoperative
EMERGENCY AISLE LIGHT INOP. REPLACED PWR SUPPLY M1135, OPS NORMAL.
- 26 Oct 1999
Air Dist, odor
ELECTRICAL ODOR EMINATING FROM FWD CABIN (ROW 4 TO FWD GALLEY) SIMILAR TO VERY POTENT MATCH SMELL. INSPECTED ACFT ELECT SYS, GALLEY PWR, OVERHEAD AND SIDEWALL…
- 23 Jul 1999
Power Supply, inop
RIGHT FWD OVERHEAD EMERGENCY LIGHTS INOP. REPLACED POWER SUPPLY AND BATTERY. SYSTEM OPS NML.
- 23 Feb 1999
Skin, cracked
THE UPPER HINGE CUTOUT OF THE AFT GALLEY DOOR (R2) CUTOUT WAS FOUND WITH A TYPICAL CRACK IN THE SKIN AND BONDED DOUBLER. THE CRACK WAS .4375 INCH LONG WITH NO…
- 18 Oct 1998
Fitting, corroded
FUSELAGE, RT AND LT MLG SIDE STRUT SUPPORT FITTING, BS 685, REPAIR FOR O/S HOLE BORES. THE LT AND RT MLG SIDE STRUT SUPPORT FITTINGS WERE FOUND WITH CORROSION…
- 12 Sep 1997
Floorbeam, cracked
THE STATION 520 FLOORBEAM HAS DAMAGE IN THE TYPICAL LOCATIONS AT BOTH LBL 24.75 AND LBL 45.5. THE BEAMS ARE M/F FROM BAC1518-338, 7075-T6511 EXTRUSION.…
- 17 Jul 1997
Battery Pack, discharged
ON L/O CHECK FOUND EMERGENCY LIGHT IN FRONT OF AFT CARGO DOOR INOP. REPLACED BATTERY PACK OPERATION NORMAL.
- 14 Apr 1997
Battery, discharged
FOUND ON LAYOVER 2 CHECK, FWD STEW FLASHLIGHT REMOVED FROM HOLDER BATTERY SPENT. REPLACED BATTERY P/N 2572 04896. CHECKS GOOD REINSTALLED AND SECURED.
- 11 Apr 1997
Acm, failed
FLIGHT ATTENDANTS AND PASSENGERS REPORTED ODOR OF SMOKE IN VICINITY OF ROW 14, NO SMOKE DETECTED IN FLIGHT AND ON GROUND. RIGHT ACM FOUND SEIZED AND TURBINE…
- 25 Jan 1997
Retract Mech, lack of lube
ON APPROACH, NUMBER 2 SLAT FAILED TO EXTEND FULLY WHEN FLAPS WERE SELECTED TO 1 DEGREE. NUMBER 2 SLAT LATER EXTENDED FULLY AFTER POM PROCEDURE WAS COMPLIED…
- 14 Nov 1996
Hose, ruptured
AFTER 15 TOUCH AND GO LANDINGS THE NOSE GEAR WOULD NOT EXTEND. LANDING GEAR WERE MANUALLY EXTENDED. AFTER THIS WAS ACCOMPLISHED PER THE CHECKLIST, THE A-HYD…
- 12 Nov 1996
Bulkhead, cracked
THE STATION 178 BULKHEAD WAS FOUND CRACKED IN SEVERAL LOCATIONS. DAMAGE CUTOUTS ARE: 1 DIA AT RBL 5.7, WL 198; 1 BY 1.5 AT RBL 5.7, WL 201; 1 BY 1.5 AT LBL…
- 9 Mar 1996
Engine, failed
EXPERIENCED MULTIPLE COMPRESSOR STALLS ON NR 2 ENGINE AT APPROXIMATELY 6,000 FEET MSL ON DEP CVG INSTANTEOUS OVERTEMP ASSOCIATED WITH MODERATE VIBRATION…
- 9 Mar 1996
Scavenge Pump, failed
THE FOLLOWING IS A SUPPLEMENT TO MRR NR 960534. SUBEQUENT FINDINGS AFTER ENGINE TEAR DOWN REVEALED THAT THE NR 4 AND NR 5 SCAVENGE PUMP FAILED RESULTING IN…
- 7 Dec 1995
Hyd Line, broken
SYS A-HYD QTY LOSS ON APPROACH. FOUND HYD LINE BROKEN AT B-NUT ON NOSE GEAR ACTUATING CYLINDER. INSTALLED TEMP LINE CHANGED A-SYS FILTERS PRESS AND CASE…
- 24 May 1995
Actuator, cracked
ON APPROACH DURING FLAP EXTENSION, LOST A SYSTEM HYDRAULICS. PRESSURE AND QTY WENT TO ZERO, LANDED CVG. FOUND LEFT OUTBOARD SPOILER ACTUATOR WITH A CRACKED…
- 30 Jan 1995
Eel, inoperative
DURING SERVICE CHECK, THE R-2 DOOR EMERGENCY EXIT LIGHT WAS FOUND INOP. REPLACED REFLECTOR AND BULB OPERATION NORMAL.