  1. 23 Dec 2014

    Avionics Unit, inoperative

    Emb EMB505

    A STATIC DISCHARGE DURING DESCENT THAT DISABLED SEVERAL ACFT SYSTEMS. DECLARED AN EMERGENCY. COMPLIED WITH A LIGHTNING STRIKE INSPECTION WITH NO DAMAGE FOUND.…

  2. 12 Nov 2012

    Access Door, detached

    Emb EMB505

    CREW REPORTED DURING POST FLIGHT INSPECTION THAT MOST OF THE BATTERY DOOR WAS MISSING FROM THE ACFT. MX INSTALLED A SERVICABLE DOOR.

  3. 25 Apr 2004

    Floorbeam, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED CORROSION AT FLOORBOARD HOLE AT STA 986, LBL 30, FLOOR BEAM UPPER CHORD. CORROSION FOUND TO BE OUT OF LIMITS PER SRM…

  4. 25 Apr 2004

    Sill, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON R1 MOP SILL. REPLACED R1 MOP SILL PER SRM 51-40-02.

  5. 25 Apr 2004

    Floorbeam, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM AT STA 328, RBL 15 AND 35. REMOVED DAMAGED TOP CHORD OF FLOORBEAM, FABRICATED AND INSTALLED NEW…

  6. 25 Apr 2004

    Floorbeam, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOORBOARD HOLE AT STA 986, LBL 30, FLOORBEAM UPPER CHORD. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM…

  7. 21 Apr 2004

    Floorbeam, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOOR BEAM AT STA. 328, RBL 15 TO RBL 35. REMOVED DAMAGED TOP CHORD OF FLOOR BEAM, FABRICATED AND INSTALLED…

  8. 19 Apr 2004

    Support, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON GALLEY SUPPORT ZEE AT STA 990, LBL 35-45. REPLACED GALLEY SUPPORT ZEE PER SRM 51-40-2.

  9. 19 Apr 2004

    Floor Support, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOOR SUPPORT SEGMENT BETWEEN STA 967 AND STA 986, LBL 16. FABRICATED AND INSTALLED REPLACEMENT FLOOR…

  10. 19 Apr 2004

    Floor Support, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOOR SUPPORT SEGMENT AT STA 957, LBL 50. REPLACED FLOOR SUPPORT SEGMENT PER SRM 51-40-02, 53-60-51 AND…

  11. 19 Apr 2004

    Sill, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON MOP SILL AT R2 DOOR. REPLACED MOP SILL PER SRM 51-40-02, 51-40-5 AND 51-40-08.

  12. 15 Apr 2004

    Sill, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON L1 MOP SILL. REPLACED L1 MOP SILL PER SRM 51-40-02 AND 53-10-15.

  13. 15 Apr 2004

    Sill, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON L2 MOP SILL AT DOOR OPENING. REMOVED MOP SILL, LOCATED AND DRILLED HOLES, AND INSTALLED PER SRM 51-10-02…

  14. 15 Apr 2004

    Support, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON GALLEY SUPPORT ZEE AT STA 990, LBL 45 TO LBL 35. FABRICATED AND INSTALLED REPLACEMENT SUPPORT PER SRM…

  15. 14 Apr 2004

    Sill, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED R1 DOORWAY LOWER SILL WEB CORRODED ON UPPER AND LOWER SURFACE. REPLACED R1 DOOR SILL WEB PER SRM 51-40-02.

  16. 14 Apr 2004

    Reveal, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED INBD EDGE OF R1 DOOR LOWER FWD REVEAL CORRODED. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS PER SRM 53-10-15.…

  17. 12 Apr 2004

    Angle, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED SURFACE CORROSION ON LOWER RT TRANSITION ANGLE FROM C2 DOOR FWD. BLENDED CORROSION ON RT TRANSITION ANGLE, STA 727E TO…

  18. 12 Apr 2004

    Web, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED CORROSION UNDER C2 DOOR THRESHOLD. REPLACED C2 DOOR WEB AND CLEANED CORROSION SURROUNDING STRUCTURE PER SRM 51-10-2.…

  19. 12 Apr 2004

    Strap, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED TAPERED STRAP INBD OF C-2 DOOR WEB SILL CORRODED. REPLACED STRAP PER SRM 51-40-02.

  20. 12 Apr 2004

    Support Angle, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM SUPPORT ANGLE AT STA 294.5, RBL 39. CORROSION FOUND TO BE OUT OF LIMITS PER SRM 51-10-2.…

  21. 12 Apr 2004

    Floorbeam, corroded

    Boeing 73736E

    DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FWD GALLEY FLOORBEAM AT STA 294.5, RBL 29.52. REPLACED FLOORBEAM SECTION PER SRM 53-10-51.

  22. 24 Jan 2004

    Indicator, malfunctioned

    Boeing 73736E

    ON APPROACH INTO DEN, FLIGHT CREW REPORTED GREEN INDICATION LIGHT DID NOT ILLUMINATE WITH LANDING GEAR DOWN. VISUALLY CONFIRMED LANDING GEAR DOWN AND LOCKED.…

  23. 19 Jul 2002

    Actuator, malfunctioned

    Boeing 73736E

    FLIGHT CREW REPORTED MOMENTARY PITCH TRIM RUNAWAY ON CLIMBOUT AT FL260. NOSE DOWN FOR APPROXIMATELY 2 SECONDS. BACK PRESSURE WAS APPLIED TO COUNTER TRIM AND…

  24. 30 Jun 2002

    Inverter, failed

    Boeing 73736E

    DURING SERVICE CHECK, INSPECTION REPORTED EMERGENCY AISLE PATH LIGHTING IN AFT CABIN INOPERATIVE. REPLACED INVERTER, PERFORMED OPERATIONAL TEST AND CHECKED…

  25. 30 Apr 2002

    Frame, dented

    Boeing 73736E

    DURING C-2 CHECK, INSPECTION REPORTED LT FUSELAGE BETWEEN STRINGERS 17L AND 18L, STA 947.5, DENTED. REPAIRED PER EA 53-737-168.

  26. 29 Apr 2002

    Stringer, damaged

    Boeing 73736E

    DURING C-2 CHECK, INSPECTION REPORTED STRINGER 18L AT STA 947.5 DAMAGED. REPLACED STRINGER PER SRM 53-00-03, 51-40-02 AND SOPM 20-41-02.

  27. 25 Apr 2002

    Sill, corroded

    Boeing 73736E

    DURING C-2 CHECK, INSPECTION REPORTED CORROSION ON L-2 THRESHOLD MOP SILL BETWEEN STA 951 AND 986.5. PERFORMED A TYPICAL FORM SECTION REPAIR PER SRM 51-70-11.

  28. 24 Apr 2002

    Floor Support, cracked

    Boeing 73736E

    DURING C-2 CHECK, INSPECTION REPORTED CRACK IN A/C DISTRIBUTION BAY FLOOR SUPPORT RT OF CENTER AT STA 540. REMOVED DAMAGED FLOOR SUPPORT. INSTALLED NEW…

  29. 19 Apr 2002

    Floorbeam, corroded

    Boeing 73736E

    DURING C-2 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM TRACK TIE IN AFT CARGO COMPARTMENT, STA 772, RBL 13.80. REMOVED CORRODED AREA, FABRICATED AND…

  30. 11 Apr 2002

    Skin, dented

    Boeing 73736E

    DURING C-2 CHECK, INSPECTION REPORTED DENT IN FWD FUSELAGE UNDER C-1 DOOR AT STA 450, BETWEEN STR 27R AND 26-R. CUT OUT DAMAGED AREA, FABRICATED AND INSTALLED…

  31. 8 Mar 2001

    Tube, corroded

    Boeing 73736E

    DURING C-1 CHECK, INSPECTION REPORTED INTERIOR OF LT INBD FOREFLAP SUPPORT TUBE CORRODED. REPLACED LT INBD FOREFLAP SUPPORT TUBE PER BAC OHM 57-53-26.

  32. 1 Mar 2001

    Pcu, leaking

    Boeing 73736E

    DURING C-1 CHECK, INSPECTION REPORTED RUDDER PCU FAILED INTERNAL LEAK TEST. REPLACED RUDDER PCU. PERFORMED RIG CHECK PER MM 27-21-00 AND CHECKED GOOD.…

  33. 17 Sep 2000

    Light, damaged

    Boeing 73736E

    LGA - FLT 417 - PRIOR TO DEPARTURE, FLIGHT CREW REPORTED EMERGENCY FLOOR PATH LIGHTING DAMAGED BETWEEN ROWS 16 AND 23. MAINTENANCE REPLACED AFT SECTION OF…

Copied daily from public FCC, FAA and NTSB downloads. Not affiliated with any of them.

sources and dates
sourcerecordsas of
FCC amateur1,702,05223 Nov 2026
FCC GMRS633,26623 Nov 2026
FCC ship radio403,52022 Nov 2026
FCC antenna structures198,13522 Nov 2026
FCC aircraft radio153,38322 Nov 2026
FAA airmen910,1651 Nov 2026
FAA deregistered aircraft383,80320 Nov 2026
FAA registered aircraft319,53720 Nov 2026
FAA N-number reservations125,98920 Nov 2026
FAA dealers12,50720 Nov 2026
FAA airports19,43329 Oct 2026
FAA service difficulty reports1,699,08023 Nov 2026
NTSB accidents, 1982 on88,0301 Nov 2026

History is kept: records the agencies stop publishing stay here, marked with the date they left.

Airmen who keep their address private aren't in the FAA's download, so they aren't here.

Not a consumer report: don't use it to screen anyone for a job, a lease, credit or insurance.

To hide your address here, email george.main@gemiv.net.