N317FL
1992 Boeing 737-36E standard FAA →
earlier registrations
1 past record
- 1992
service difficulty reports
33 reports
- 23 Dec 2014
Avionics Unit, inoperative
A STATIC DISCHARGE DURING DESCENT THAT DISABLED SEVERAL ACFT SYSTEMS. DECLARED AN EMERGENCY. COMPLIED WITH A LIGHTNING STRIKE INSPECTION WITH NO DAMAGE FOUND.…
- 12 Nov 2012
Access Door, detached
CREW REPORTED DURING POST FLIGHT INSPECTION THAT MOST OF THE BATTERY DOOR WAS MISSING FROM THE ACFT. MX INSTALLED A SERVICABLE DOOR.
- 25 Apr 2004
Floorbeam, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION AT FLOORBOARD HOLE AT STA 986, LBL 30, FLOOR BEAM UPPER CHORD. CORROSION FOUND TO BE OUT OF LIMITS PER SRM…
- 25 Apr 2004
Sill, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON R1 MOP SILL. REPLACED R1 MOP SILL PER SRM 51-40-02.
- 25 Apr 2004
Floorbeam, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM AT STA 328, RBL 15 AND 35. REMOVED DAMAGED TOP CHORD OF FLOORBEAM, FABRICATED AND INSTALLED NEW…
- 25 Apr 2004
Floorbeam, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOORBOARD HOLE AT STA 986, LBL 30, FLOORBEAM UPPER CHORD. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM…
- 21 Apr 2004
Floorbeam, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOOR BEAM AT STA. 328, RBL 15 TO RBL 35. REMOVED DAMAGED TOP CHORD OF FLOOR BEAM, FABRICATED AND INSTALLED…
- 19 Apr 2004
Support, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON GALLEY SUPPORT ZEE AT STA 990, LBL 35-45. REPLACED GALLEY SUPPORT ZEE PER SRM 51-40-2.
- 19 Apr 2004
Floor Support, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOOR SUPPORT SEGMENT BETWEEN STA 967 AND STA 986, LBL 16. FABRICATED AND INSTALLED REPLACEMENT FLOOR…
- 19 Apr 2004
Floor Support, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOOR SUPPORT SEGMENT AT STA 957, LBL 50. REPLACED FLOOR SUPPORT SEGMENT PER SRM 51-40-02, 53-60-51 AND…
- 19 Apr 2004
Sill, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON MOP SILL AT R2 DOOR. REPLACED MOP SILL PER SRM 51-40-02, 51-40-5 AND 51-40-08.
- 15 Apr 2004
Sill, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON L1 MOP SILL. REPLACED L1 MOP SILL PER SRM 51-40-02 AND 53-10-15.
- 15 Apr 2004
Sill, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON L2 MOP SILL AT DOOR OPENING. REMOVED MOP SILL, LOCATED AND DRILLED HOLES, AND INSTALLED PER SRM 51-10-02…
- 15 Apr 2004
Support, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON GALLEY SUPPORT ZEE AT STA 990, LBL 45 TO LBL 35. FABRICATED AND INSTALLED REPLACEMENT SUPPORT PER SRM…
- 14 Apr 2004
Sill, corroded
DURING C-4 CHECK, INSPECTION REPORTED R1 DOORWAY LOWER SILL WEB CORRODED ON UPPER AND LOWER SURFACE. REPLACED R1 DOOR SILL WEB PER SRM 51-40-02.
- 14 Apr 2004
Reveal, corroded
DURING C-4 CHECK, INSPECTION REPORTED INBD EDGE OF R1 DOOR LOWER FWD REVEAL CORRODED. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS PER SRM 53-10-15.…
- 12 Apr 2004
Angle, corroded
DURING C-4 CHECK, INSPECTION REPORTED SURFACE CORROSION ON LOWER RT TRANSITION ANGLE FROM C2 DOOR FWD. BLENDED CORROSION ON RT TRANSITION ANGLE, STA 727E TO…
- 12 Apr 2004
Web, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION UNDER C2 DOOR THRESHOLD. REPLACED C2 DOOR WEB AND CLEANED CORROSION SURROUNDING STRUCTURE PER SRM 51-10-2.…
- 12 Apr 2004
Strap, corroded
DURING C-4 CHECK, INSPECTION REPORTED TAPERED STRAP INBD OF C-2 DOOR WEB SILL CORRODED. REPLACED STRAP PER SRM 51-40-02.
- 12 Apr 2004
Support Angle, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM SUPPORT ANGLE AT STA 294.5, RBL 39. CORROSION FOUND TO BE OUT OF LIMITS PER SRM 51-10-2.…
- 12 Apr 2004
Floorbeam, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FWD GALLEY FLOORBEAM AT STA 294.5, RBL 29.52. REPLACED FLOORBEAM SECTION PER SRM 53-10-51.
- 24 Jan 2004
Indicator, malfunctioned
ON APPROACH INTO DEN, FLIGHT CREW REPORTED GREEN INDICATION LIGHT DID NOT ILLUMINATE WITH LANDING GEAR DOWN. VISUALLY CONFIRMED LANDING GEAR DOWN AND LOCKED.…
- 19 Jul 2002
Actuator, malfunctioned
FLIGHT CREW REPORTED MOMENTARY PITCH TRIM RUNAWAY ON CLIMBOUT AT FL260. NOSE DOWN FOR APPROXIMATELY 2 SECONDS. BACK PRESSURE WAS APPLIED TO COUNTER TRIM AND…
- 30 Jun 2002
Inverter, failed
DURING SERVICE CHECK, INSPECTION REPORTED EMERGENCY AISLE PATH LIGHTING IN AFT CABIN INOPERATIVE. REPLACED INVERTER, PERFORMED OPERATIONAL TEST AND CHECKED…
- 30 Apr 2002
Frame, dented
DURING C-2 CHECK, INSPECTION REPORTED LT FUSELAGE BETWEEN STRINGERS 17L AND 18L, STA 947.5, DENTED. REPAIRED PER EA 53-737-168.
- 29 Apr 2002
Stringer, damaged
DURING C-2 CHECK, INSPECTION REPORTED STRINGER 18L AT STA 947.5 DAMAGED. REPLACED STRINGER PER SRM 53-00-03, 51-40-02 AND SOPM 20-41-02.
- 25 Apr 2002
Sill, corroded
DURING C-2 CHECK, INSPECTION REPORTED CORROSION ON L-2 THRESHOLD MOP SILL BETWEEN STA 951 AND 986.5. PERFORMED A TYPICAL FORM SECTION REPAIR PER SRM 51-70-11.
- 24 Apr 2002
Floor Support, cracked
DURING C-2 CHECK, INSPECTION REPORTED CRACK IN A/C DISTRIBUTION BAY FLOOR SUPPORT RT OF CENTER AT STA 540. REMOVED DAMAGED FLOOR SUPPORT. INSTALLED NEW…
- 19 Apr 2002
Floorbeam, corroded
DURING C-2 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM TRACK TIE IN AFT CARGO COMPARTMENT, STA 772, RBL 13.80. REMOVED CORRODED AREA, FABRICATED AND…
- 11 Apr 2002
Skin, dented
DURING C-2 CHECK, INSPECTION REPORTED DENT IN FWD FUSELAGE UNDER C-1 DOOR AT STA 450, BETWEEN STR 27R AND 26-R. CUT OUT DAMAGED AREA, FABRICATED AND INSTALLED…
- 8 Mar 2001
Tube, corroded
DURING C-1 CHECK, INSPECTION REPORTED INTERIOR OF LT INBD FOREFLAP SUPPORT TUBE CORRODED. REPLACED LT INBD FOREFLAP SUPPORT TUBE PER BAC OHM 57-53-26.
- 1 Mar 2001
Pcu, leaking
DURING C-1 CHECK, INSPECTION REPORTED RUDDER PCU FAILED INTERNAL LEAK TEST. REPLACED RUDDER PCU. PERFORMED RIG CHECK PER MM 27-21-00 AND CHECKED GOOD.…
- 17 Sep 2000
Light, damaged
LGA - FLT 417 - PRIOR TO DEPARTURE, FLIGHT CREW REPORTED EMERGENCY FLOOR PATH LIGHTING DAMAGED BETWEEN ROWS 16 AND 23. MAINTENANCE REPLACED AFT SECTION OF…