N314NV
Airbus A319-111 FAA →
reservations
earlier registrations
1 past record
service difficulty reports
16 reports
- 3 Apr 2023
Epsu, unknown
BAT/EPSU(10WL)FWD L CLASS 1 / R+R EPSU BATTTERY IAW AMM REF 33-51-38-000-002-A AND 33-51-38-400-002-A"
- 10 Mar 2023
Profile, none
DURING INSPECTION LOWER FUSELAGE AFT CARGO COMPARTMENT AT FR56, BETWEEN 260 AND Y 680 PROFILES WITH ELONGATED HOLES WAS FOUND. THE AFFECTED PROFILES WERE…
- 10 Mar 2023
Floorbeam, corroded
DURING INSPECTION ON REAR FUSELAGE PAX CABIN FROM FR66+140MM TO FR 68 AT -Y 765 FLOOR BEAM WITH CORROSION WAS FOUND. THE AFFECTED FLOOR BEAM WAS REPLACED IAW…
- 10 Mar 2023
None, corroded
DURING INSPECTION #1 ENGINE LH PYLON AFT MOVABLE FAIRING ACCESS PANEL 477AL, FIXED CUTOUT INTERNAL AFT LOWER CORNER WITH CORROSION WAS FOUND.PERMANENT REPAIR…
- 1 Feb 2023
Epsu, not entered
REF. W/O# 00471872-3 CABIN EMERGENCY LIGHTING. FAULTED EPSU BATTERY 13WL DURING TEST. / R&R EPSU BATTERY 13WL IAW AMM 33-51-38 PB401. NO FAULTS NOTED. SYS.…
- 3 Nov 2022
Epsu, none
R2 EMERGENCY EXITFLOOR LIGHT INOP / REMOVED AND REPLACED EPSU ABOVE R2 DOOR PER AMM 33-51-00-710-001, OPS CK GOOD"
- 18 Aug 2022
Frame, mislocated
(N0008) 7 FASTENER HOLES ARE MISDRILLED AT FR68RH DOOR FRAME AT STGR10RH DOOR FITTING #7 / REPAIRED 7 MIS-DRILLED HOLES IAW EA 79-2022-134 ON FR68 RH DOOR…
- 23 May 2022
Skin, defective
DURING THE FINAL AIRCRAFT EXTERNAL CLEANING, IT WAS FOUND THE RUDDER P/N 5547100400000 S/N 5547100400000, LEADING EDGE LOWER SECTION WITH MISSING MATERIAL ON…
- 11 May 2022
Frame, none
DURING THE INSPECTION STRUCTURE INSPECTION PER RDAS 80150308/002/2016 ISSUE B ROTO TEST INSPECTIONS, THERE WERE FOUND TOOL MARKS BETWEEN STRG 19LH AND STRG…
- 17 Apr 2022
Frame, cracked
DURING THE INSPECTION STRUCTURE INSPECTION PER RDAS 80150308/002/2016 ISSUE A ROTO TEST INSPECTIONS, THERE WERE FOUND TWO HOLES WITH CRACK INDICATION AT FRAME…
- 8 Feb 2022
Epsu, none
EPSU TEST READS EMER R (12WL) FAILED TEST. / REMOVED AND REPLACED R/H EMERGENCY ROW EPSU BATTERY (12WL) IAW AMM 33-51-38. TEST OK."
- 19 Oct 2021
Battery Pack, no test
EPSU BAT FAULT FOR 10WL AND 13WL DURING EPSU TEST. / REMOVED AND REPLACED EPSU BATTERY FOR 10WL AND 13WL REF A319 AMM 33-51-38 PB401. OPS CHECK GOOD."
- 25 Feb 2020
Power Supply, no test
EMERGENCY POWER SUPPLY FAILED DURING LIGHTING CK /REPLACED EMERGENCY POWER SUPPLY"
- 25 Feb 2020
Power Supply, no test
EMERGENCY POWER SUPPLY FAILED DURING LIGHTING CK /REPLACED EMERGENCY POWER SUPPLY"
- 31 Jan 2020
Megaphone, inoperative
FWD CABIN MEGA PHONE INOP / REPLACED FWD CABIN MEGA PHONE"
- 8 Jun 2019
Unknown, odor
EMERGENCY DECLARED) BURNING SMELL AND HAZE IN COCKPIT & CABIN DURING T/O ROLL AND INITIAL CLIMB / APU OPS CHECK GOOD.