1 past record
- 1990
service difficulty reports
115 reports
- 24 Jan 2018
Structure, cracked
OVERSIZED HOLES AND CRACKS WERE FOUND DURING SHOP ACCOMPLISHMENT OF EM 5230-01163 (AD 2017-22-07) TO FWD CARGO DOOR, P/N D52371000012 S/N UH-1153, REPAIRED…
- 8 Aug 2017
Connector, malfunctioned
WHILE PERFORMING EMERGENCY LIGHT TEST DURING SERVICE CHECK, HAD MULTIPLE MESSAGES INTERNAL LIGHT FAULT. DISCONNECTED & RECONNECTED R MIN CABIN EPSU CONNECTOR.…
- 30 Jun 2017
Lamp, inoperative
EMERGENCY LIGHT SEAT 5 LT INOPERATIVE, REPLACED THE LAMPS.
- 5 Feb 2017
Battery Pack, no test
SERVICE CHECK FOUND EMERGENCY LIGHTS TEST FAILED, REPLACED THE BATTERY.
- 6 Dec 2016
Frame, cracked
FRAME 16 WAS FOUND CRACKED, PERFORMED TEMPORARY REPAIR IAW ER/A 551555-14AD REVISION ORIGINAL.
- 4 Dec 2016
Stringer, corroded
CORROSION ON STRINGER 31R IN AFT CARGO COMPARTMENT BETWEEN FRAME 65 TO FRAME 66. REPLACED STRINGER 31R IN AFT CARGO COMPARTMENT FROM FRAME 64 TO FRAME 67 AS…
- 3 Dec 2016
Stringer, corroded
CORROSION ON STRINGER 25R IN AFT CARGO COMPARTMENT BETWEEN FRAME 65 TO FRAME 66. REPLACED STRINGER 25R IN AFT CARGO COMPARTMENT BETWEEN FR 64 TO FR 67 AS PER…
- 28 Nov 2016
Frame, cracked
CRACK ON LATERAL FWD SEGMENT FRAME ON EMERGENCY EXIT DOOR 844 IN PASSENGER CABIN, REPLACED LATERAL FWD SEGMENT FRAME IAW SRM 51-72-11 AND DRAWING D52279010
- 28 Sep 2015
Light, damaged
EMERGENCY SEAT MOUNTED LIGHT DAMAGED. REPLACED LIGHT ASSY.
- 1 Sep 2014
Light, missing
DURING NON-ROUTINE CHECK, FOUND SEAT 20A MISSING AISLE EMERGENCY LIGHT. MAINTENANCE REPLACED EMERGENCY LIGHT AND FUNCTIONAL CHECKED NORMAL.
- 4 Jul 2014
Wire, pulled
DURING NON ROUTINE CHECK, FOUND EMERGENCY LIGHTS AT SEATS 08C-23C INOPERATIVE. MAINTENANCE FOUND WIRE PULLED FROM SPLICE AT EACH LOCATION. SPLICED WIRES BACK…
- 12 Jul 2013
Battery Pack, failed
DURING CRUISE EMERGENCY EXIT LIGHTS AND THE EMERGENCY AISLE LIGHTING WERE FLASHING ERRATICALLY ON AND OFF WITH EMERGENCY LIGHT SWITCH IN ARMED POSITION. MX…
- 8 Jul 2013
Epsu, failed
DURING NON ROUTINE CHECK, FOUND EPSU INTERNAL LOAD EMERGENCY LIGHT FAILED. MX REPLACED EPSU 10WL AND FUNCTIONAL CHECKED NORMAL.
- 11 Feb 2013
Shear Tie, corroded
DURING INSPECTION, FOUND FWD CARGO AT FR 31 BET CENTERLINE AND STR 43R, SHEAR TIE HAS CORROSION. CHECKED LIMITS L=1.00" W=1.00" D=0.010". NO ALLOWABLE DAMAGE…
- 7 Feb 2013
Structure, cracked
DURING INSPECTION, FOUND LT AFT EMERGENCY EXIT DOOR, AFT LOAD TRANSMITTING PROFILE FOUR FASTENER HOLES HAS CRACK. HFEC IAW NTM 51-10-08 CRACK INDICATION NOTED…
- 7 Feb 2013
Structure, cracked
DURING INSPECTION, FOUND LT FWD EMERGENCY EXIT DOOR, AFT LOAD TRANSMITTING PROFILE FASTENER HOLES (5EA) HAS CRACK. HFEC IAW NTM 51-10-08 CRACK INDICATION…
- 7 Feb 2013
Web, corroded
DURING INSPECTION, FOUND AFT CARGO BAY FRAME 55-56, STR 39-40R WEB PLATE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW ER/A…
- 7 Feb 2013
Floor Panel, corroded
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 152KF IS CORRODED. REMOVED CORROSION IAW SRM 51-74-00, L=1.0" W=0.70" D=0.050 NO ESTABLISHED SRM LIMITS.
- 6 Feb 2013
Structure, corroded
DURING INSPECTION, FOUND LT AFT EMERGENCY EXIT DOOR FWD LOWER T SECTION HAS CORROSION. REMOVED OLD "T" SECTION IAW SRM 51-42-11. TREATED AND PRIMED HOLES IAW…
- 6 Feb 2013
Floor Support, corroded
DURING INSPECTION, FOUND AFT CARGO BAY FRAME 59 STR 44 FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION NO LIMITS IN SRM 53-41-14 L=.5" W=.5" D=.020". REMOVED…
- 6 Feb 2013
Structure, corroded
DURING INSPECTION, FOUND RT AFT EMERGENCY EXIT DOOR, FWD LOWER TEE SECTION HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00 L=2.0" W=1.5" D=.040" NO…
- 6 Feb 2013
Structure, corroded
DURING INSPECTION, FOUND RT FWD EMERGENCY EXIT DOOR, FWD LOWER TEE SECTION HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00 L=1.0" W=.70" D=.012" NO…
- 6 Feb 2013
Structure, corroded
DURING INSPECTION, FOUND RT FWD EMERGENCY EXIT DOOR LOWER AFT TEE SECTION HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00 L=.90" W=.80" D=.010" NO ALLOWABLE…
- 6 Feb 2013
Structure, cracked
DURING INSPECTION, RT AFT EMERGENCY EXIT DOOR, AFT LOAD TRANSMITTING PROFILE FASTENER HOLE HAS CRACK. HFEC IAW NTM 51-10-08 CRACK INDICATION NOTED .027"…
- 6 Feb 2013
Structure, cracked
DURING INSP, FOUND RT FWD EMERGENCY EXIT DOOR, FWD LOAD TRANSMITTING PROFILE (9EA) FASTENER HOLE HAS CRACKED. HFEC IAW NTM 51-10-08 CRACK INDICATION NOTED…
- 6 Feb 2013
Profile, cracked
DURING INSPECTION, FOUND LT AFT EMERGENCY EXIT DOOR, AFT LOAD TRANSMITTING PROFILE (4EA) FASTENER HOLES HAS CRACK. CRACK INDICATION NOTED .025" LENGTH OF…
- 5 Feb 2013
Floor Support, corroded
DURING INSPECTION, FOUND AFT CARGO FRAME 58-59, STR 44, FLOOR SUPPORT CORRODED. REMOVED AFT CARGO FLOOR SUPPORT IAW A320 SRM 51-42-11 FR 58-59 STR 44. REMOVED…
- 4 Feb 2013
Frame Splice, gouged
DURING INSPECTION, FOUND FWD CARGO COMPT FR26 FRAME SPLICE AFT FACE IS GOUGED STR 35L. REPLACED FISH PLATE IAW SRM 51-42-11 DWG NR C2.D53230405. BLENDED FISH…
- 4 Feb 2013
Frame, gouged
DURING INSPECTION, FOUND FWD CARGO COMPT FR28 FRAME SPLICE AFT FACE IS GOUGED STR 35L. BLENDED FISH PLATE IAW SRM 51-73-00, MEASUREMENTS ARE L=1.5" W=.5" D=.…
- 4 Feb 2013
Structure, gouged
DURING INSPECTION, FOUND LT PYLON PYRAMID MATING FACE MID GUIDE PIN HOLE HAS GOUGE. REMOVED GOUGE IAW TRM 54-51-18. CHECKED LIMITS: AREA 1L=0.446" W=0.022"…
- 4 Feb 2013
Structure, gouged
DURING INSPECTION, FOUND LT PYLON PYRAMID MATING FACE AFT GUIDE PIN HOLE HAS GOUGE. REMOVED GOUGE IAW A320 TRM 54-51-18. CHECKED LIMITS: AREA 1L=0.284"…
- 4 Feb 2013
Door, corroded
DURING INSPECTION, FOUND LT AFT EMERGENCY EXIT DOOR FWD LOWER T SECTION HAS CORROSION. REMOVED OLD "T" SECTION IAW SRM 51-42-11. TREATED AND PRIMED HOLE S IAW…
- 3 Feb 2013
Stop Fitting, chafed
DURING INSPECTION, FOUND LT AFT PASSENGER ENTRANCE FRAME 68 ROLLER STOP FITTING ON MID OUTER SURFACE HAS CHAFED. REPLACED ROLLER STOP FITTING AT LT AFT PAX…
- 3 Feb 2013
Frame, corroded
DURING INSPECTION, FOUND AFT CARGO FRAME 55-58, STR 43L HAS CORROSION. REMOVED CORROSION IAW 51-74-00 FROM STRINGER 43L BET FRAME 55-58 AND FOUND NO…
- 2 Feb 2013
Stringer, corroded
DURING INSPECTION, FOUND AFT CARGO FRAME 56-57, STR 41L HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. CHECKED DAMAGE DIMENSION S L=5.0" W=1.0"D=0.012".…
- 2 Feb 2013
Skin, gouged
DURING INSPECTION, FOUND RT NR 4 SLAT LWR T/E SKIN HAS GOUGE 10" INBD OF SLAT TRACK NR 10. ACCOMPLISHED REPAIR IAW ER/A 509275-14 REV ORIGINAL AS PERMANENT…
- 31 Jan 2013
Floorboard, cracked
DURING INSPECTION, FOUND MID CABIN FLOORBOARD 232MF CORNER EDGE IS CRACKED. FLOORBOARD FABRICATED IAW SRM 53-02-00, FIG 209.
- 30 Jan 2013
Floorboard, delaminated
DURING INSPECTION, FOUND MID CABIN BETWEEN FR35 TO 36 MOST CENTER FLOORBOARD 241AF HAS DELAMINATION. REPLACED FLOORBOARDIAW AMM 53-12-12-400-001-A. FABRICATED…
- 29 Jan 2013
Floor Panel, damaged
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 161 BF IS DAMAGED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209. INSTALLED ON WC 2500-5019 AND DWG…
- 28 Jan 2013
Floor Support, damaged
DURING INSPECTION, FOUND FORWARD CABIN UTILITY AREA FLOORBEAM BETWEEN FR 16-20 Y-254 UPPER FLANGE HOLES HAS CORROSION. REMOVED DAMAGE IAW SRM 51-74-00. DAMAGE…
- 28 Jan 2013
Floor Panel, damaged
DURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261EF INSERTS DAMAGED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209. INSTALLED ON WC 2500-6602.
- 23 Jan 2013
Fitting, corroded
DURING INSPECTION, FOUND NR 1 ENGINE SPIGOT RECEPTACLE FITTING BORE AT UPPER SPAR HAS FITTING CORROSION. REMOVED CORROSION IAW SRM 51-74-00 FINAL DIAMETER…
- 23 Jan 2013
Sill, corroded
DURING INSPECTION, FOUND RT AFT PASSENGER ENTRANCE LOWER DOOR SILL AT FWD FR68 GIRT BAR & INBD HOLES HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00.…
- 23 Jan 2013
Skin, gouged
DURING INSPECTION, FOUND LOWER FUSELAGE JUST AFT OF FR 65 BETWEEN STR 28L - 29L SKIN APPEARS TO BE GOUGED UNDER PAINT. N/R 100/4. CUTOUT DAMAGED SKIN IAW SRM…
- 22 Jan 2013
Floorboard, damaged
DURING INSPECTION, FOUND MAIN CABIN, FWD AREA FLOORBOARD 232DF HAS A HOLE .300" X .500". FABRICATED FLOORBOARD IAW SRM 53-02-00, FIG 209.
- 22 Jan 2013
Floor Panel, gouged
DURING INSPECTION, FOUND MAIN CABIN FWD AREA FLOOR PANEL 231CF HAS GOUGE 3" X 2". FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 22 Jan 2013
Floor Panel, corroded
DURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261FF HAS CORROSION 4" X 6". REPLACED FLOOR PANEL IAW SRM 51-72-00.
- 21 Jan 2013
Web, corroded
DURING INSPECTION, FOUND FORWARD CABIN RT SIDE STRINGER 23 BETWEEN FR 20 TO 21 UPPER SURFACE WEB CORRODED. REMOVED CORROSION IAW SRM 51-74-00. REPLACED WEB…
- 20 Jan 2013
Panel, eroded
DURING INSPECTION, FOUND AFT CARGO SLOPING WALL PANEL 152QF HAS EDGE EROSION (4" X 1") N/R 100/62. FABRICATED NEW SLOPING WALL PANEL IAW SRM 53-02-00 FIG 209.
- 20 Jan 2013
Panel, damaged
DURING INSPECTION, FOUND AFT CARGO SLOPING WALL PANEL 161FF IS DAMAGED (3" X 2") PN D5367204800000. N/R 100/69. FABRICATED NEW SLOPING WALL PANEL IAW SRM…
- 20 Jan 2013
Panel, punctured
DURING INSPECTION, FOUND AFT CARGO SLOPING WALL PANEL 152RF PUNCTURED (3" X 1") N/R 100/59. FABRICATED NEW SLOPING WALL PANEL IAW SRM 53-02-00, FIG 209.
- 20 Jan 2013
Panel, eroded
DURING INSPECTION, FOUND AFT CARGO SLOPING WALL PANEL 152EF HAS EDGE EROSION AROUND TOP CUT OUT (9" X 4"). FABRICATED NEW SLOPE PANE IAW SRM 53-02-00, FIG 209.
- 20 Jan 2013
Panel, punctured
DURING INSPECTION, FOUND FWD CARGO SLOPING WALL PANEL 131GF IS PUNCTURED. FABRICATED NEW SLOPE WALL PANEL IAW SRM 53-02-00, FIG 209.
- 20 Jan 2013
Panel, damaged
DURING INSPECTION, FOUND FWD CARGO SLOPING WALL PANEL 131KF HAS EDGE DAMAGE. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00, FIG 209.
- 20 Jan 2013
Panel, damaged
DURING INSPECTION, FOUND FWD CARGO SLOPING WALL PANEL 131FF HAS EDGE DAMAGE. FABRICATED NEW SLOPE WALL PANEL IAW SRM 53-02-00, FIG 209.
- 20 Jan 2013
Panel, damaged
DURING INSPECTION, FOUND FWD CARGO SLOPING WALL PANEL 131BF HAS EDGE DAMAGE. FABRICATED NEW SLOPE WALL PANEL IAW SRM 53-02-00, FIG 209.
- 20 Jan 2013
Floor Panel, damaged
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 161DF HAS DAMAGE AT TOP CUTOUT. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 20 Jan 2013
Floor Panel, damaged
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 161AF HAS CORNER DAMAGE & EROSION AROUND TOP CUTOUTS. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 20 Jan 2013
Floor Panel, damaged
DURING INSPECTION, FOUND FWD CARGO FLOOR PANEL 131EF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 20 Jan 2013
Floorboard, damaged
DURING INSPECTION, FOUND MAIN CABIN CENTER WING AREA FLOORBOARD 241JF IS DAMAGED AND MISSING INSERT. FABRICATED NEW FLOORBOARD IAW SRM 53-02-00, FIG 209.
- 20 Jan 2013
Floor Panel, dented
DURING INSPECTION, FOUND MAIN CABIN CENTER WING AREA FLOOR PANEL 241DF HAS INDENTION ON BOTTOM. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 20 Jan 2013
Floor Panel, punctured
DURING INSPECTION, FOUND MAIN CABIN CENTER WING AREA FLOOR PANEL 241LF HAS PUNCTURE. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 19 Jan 2013
Sill, corroded
DURING INSPECTION, FOUND LT AFT PASSENGER ENTRANCE LWR DOOR SILL AT AFT FR66 GIRT BAR HOLES UPPER SURFACE HAS REMOVED CORROSION IAW SRM 51-74-00. CHECKED…
- 18 Jan 2013
Shackle, damaged
DURING INSPECTION, FOUND RT PYLON AFT SHACKLE FWD PIECE, FWD FACE CHAFED AROUND THREE BUSHINGS. REPLACED WITH SERVICEABLE PART. SHACKLE INSTALLED ON W/C…
- 17 Jan 2013
Floor Panel, damaged
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151GF IS DAMAGED, PN D5367205300000. 3" X 2.5". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 17 Jan 2013
Floor Panel, damaged
DURING INPECTION, FOUND AFT CARGO FLOOR PANEL 151LF IS DAMAGED, 4.0" X 4.0". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 17 Jan 2013
Floor Panel, damaged
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151AF IS DAMAGED. 4.5" X 3.0". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 17 Jan 2013
Floor Panel, damaged
DURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151DF IS DAMAGED. 3.0" X 2.0". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 17 Jan 2013
Floor Panel, damaged
DURING INSPECTION, FOUND FWD CARGO FLOOR PANEL 131AF HAS EDGE DAMAGED 3.0" X 3.0". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.
- 17 Jan 2013
Panel, damaged
DURING INSPECTION, FOUND AFT CARGO SLOPING WALL PANEL 151NF IS SOFT (3" X 2.5"). FABRICATED NEW PANEL IAW SRM 53-02-00, FIG 209.
- 17 Jan 2013
Panel, punctured
DURING INSPECTION, FOUND AFT CARGO SLOPING WALL PANEL 151MF HAS PUNCTURE & EDGE EROSION A ROUND TDP CUT OUT (4" X 1"). FABRICATED NEW PANEL IAW SRM 53-02-00,…
- 17 Jan 2013
Panel, damaged
DURING INSPECTION, FOUND AFT CARGO SLOPING WALL PANEL 151EF IS DAMAGED 4" X 1". FABRICATED NEW PANEL IAW SRM 53-02-00, FIG 209.
- 17 Jan 2013
Panel, damaged
DURING INSPECTION, FOUND AFT CARGO SLOPING WALL PANEL 152CF IS DAMAGED (8" X 1"). FABRICATED NEW PANEL IAW SRM 53-02-00, FIG 209.
- 17 Jan 2013
Panel, damaged
DURING INSPECTION, FOUND AFT CARGO SLOPING WALL PANEL 162BF IS DAMAGED (3" X 12"). FABRICATED NEW PANEL IAW SRM 53-02-00 FIG 209.
- 17 Jan 2013
Panel, damaged
DURING INSPECTION, FOUND AFT CARGO SLOPING WALL PANEL 161EF HAS EDGE DAMAGE AROUND TDP CUT OUT (1" X 1"). FABRICATED NEW PANEL IAW SRM 53-02-00, FIG 209.
- 17 Jan 2013
Panel, damaged
DURING INSPECTION, FOUND FWD CARGO SLOPING WALL PANEL 131JF HAS EDGE DAMAGE 3.5" X 4.0". FABRICATED NEW PANEL IAW SRM 53-02-00, FIG 209.
- 17 Jan 2013
Panel, damaged
DURING INSPECTION, FOUND FORWARD CARGO COMPARTMENT SLOPE PANEL 131CF IS DAMAGED. 1" X 1". FABRICATED NEW PANEL IAW SRM 53-02-00, FIG 209.
- 17 Jan 2013
Seat Track, corroded
DURING INSPECTION, FOUND FORWARD CABIN SEAT TRACK BETWEEN FR 20 TO FR 21 Y-765 UPPER CROWN HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. BLENDED AREA…
- 16 Jan 2013
Floor Panel, corroded
DURING INSPECTION, FOUND MAIN CABIN FWD UTILITY AREA FLOOR PANEL 221FF HAS CORROSION ON BOTTOM AREA 3" X 1". NO ESTABLISHED LIMITS IAW SRM. REPLACED FLOOR…
- 16 Jan 2013
Floor Panel, corroded
DURING INSPECTION, FOUND MAIN CABIN FWD UTILITY AREA FLOOR PANEL 222FF HAS CORROSION ON BOTTOM AREA 6" X 1". NO ESTABLISHED LIMITS IAW SRM. REPLACED FLOOR…
- 16 Jan 2013
Fitting, mismanufactured
DURING INSPECTION, FOUND RT AFT PASSENGER ENTRANCE LOWER MID FWD SHAPE FITTING EXISTING HOLES MISDRILLED. REMOVED DOORSILL SHAPE FITTING IAW SRM 51-42-11.…
- 16 Jan 2013
Floor Panel, corroded
DURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 262FF HAS CORROSION. FLOOR PANEL REPLACED IAW SRM 51-72-00.
- 14 Jan 2013
Seat Track, gouged
DURING INSPECTION, FOUND MID CABIN SEAT TRACK BETWEEN FR35-FR36 Y765 HAS GOUGE. REMOVED DAMAGE & FOUND TO BE OUT OF LIMITS IAW TRM 53-00-15, FIG 1, BOTTOM…
- 14 Jan 2013
Structure, corroded
DURING INSPECTION, FOUND LT AFT PASSENGER ENTRANCE LOWER MID FWD SHAPE FITTING CORRODED. REMOVED CORROSION IAW SRM 51-74-00. REPLACED SHAPE SILL IAW SRM…
- 14 Jan 2013
Hinge Pin, damaged
DURING INSPECTION, FOUND LT AILERON, HINGE PIN NR 3 SCORED. NEW LT AILERON NR 3 HINGE INSTALLED. SCORED NR 3 HINGE PIN FOUND OUT OF LIMITS PER AMM 27-14-41,…
- 13 Jan 2013
Floor Support, corroded
DURING INSPECTION, FOUND FORWARD CABIN FLOOR SUPPORT BETWEEN FR20 TO FR23, Y-189 UPPER FLANGE CORROSION AND SCRIBE LINE MARKS. BLENDED FLOOR SUPPORT IAW SRM…
- 12 Jan 2013
Floor Support, corroded
DURING INSPECTION, FOUND AFT CABIN UTILITY AREA FLOOR SUPPORT BETWEEN FR64 TO FR66, Y765 UPPER FLANGE AND INSIDE HARD POINT HOLES HAS CORROSION. REMOVED…
- 11 Jan 2013
Floor Support, corroded
DURING INSPECTION, FOUND FORWARD CABIN UTILITY AREA FLOOR SUPPORT BETWEEN FR12 TO FR22, Y254 UPPER FLANGE HAS CORROSION. REMOVED CORROSION FROM FLOOR SUPPORT…
- 9 Jan 2013
Floor Support, corroded
DURING INSPECTION, FOUND AFT CABIN UTILITY AREA FLOOR SUPPORT BETWEEN FR 65-67, Y-308 INSIDE HARD POINT HOLES 3EA HAS SURFACE CORROSION. BLENDED AREA IAW SRM…
- 8 Jan 2013
Floor Support, corroded
DURING INSPECTION, FOUND FORWARD CABIN UTILITY AREA FLOORBEAM BETWEEN FR 12-16, Y503.2 UPPER FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. ORIG…
- 7 Jan 2013
Floorbeam, corroded
DURING INSPECTION, AFT CABIN UTILITY AREA FLOORBEAM AT FR 66, Y1292 UPPER FLANGE HAS CORROSION AND ELONGATED HOLE. REMOVED CORROSION IAW SRM 51-74-00. CHECKED…
- 20 Sep 2012
Charger, faulty
DURING NON ROUTINE CHECK, FOUND EMERGENCY BATTERY CHARGER UNIT FAULTING FWD LT. MX REPLACED EMERGENCY LIGHTS EPSU AND FUNCTIONAL CHECK WAS NORMAL.
- 9 Apr 2012
Light, inoperative
DURING NON ROUTINE CHECK, FOUND LT AFT EPSU UNIT FAULT TEST. MAINTENANCE REPLACED EPSU UNIT AND OPERATIONAL CHECK WAS NORMAL. AIRCRAFT WAS RETURNED TO SERVICE.
- 28 Aug 2011
Light, wrong part
DURING EMERGENCY LIGHT TEST ALL 4 EMERGENCY EXIT HANDLE LIGHTS WERE NOT WORKING. REPLACED BULBS NO HELP. FOUND WRONG BULBS INSTALLED, REPLACED BULBS AND TESTS…
- 27 Jul 2011
Wire, broken
DURING NON-ROUTINE CHECK, FOUND THE EMERGENCY ESCAPE LIGHT AT 23C INOPERATIVE. MAINTENANCE REPAIRED BROKEN WIRE AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT…
- 15 Mar 2011
Battery Pack, discharged
DURING EMERGENCY LIGHT TEST, FOUND LEFT FRONT BATTERY PACK INOP. BATTERY PACK WAS REPLACED AND TESTS OK.
- 17 Dec 2010
Floor Panel, delaminated
DURING L-CHECK, FOUND FWD CARGO COMPARTMENT, ZONE 130 FLOOR PANEL 131EF HAS DELAMINATION. REMOVED FLOOR PANEL 131EF IAW AMM 53-22-14-000-001. FABRICATED NEW…
- 17 Dec 2010
Floor Panel, cracked
DURING L-CHECK, FOUND AFT CARGO COMPARTMENT FLOOR PANEL 151PF CRACKED. REMOVED FLOOR PANEL IAW AMM 53-42-14-000-001. FABRICATED NEW PANEL IAW SRM 53-02-00,…
- 17 Dec 2010
Floor Panel, delaminated
DURING L-CHECK FOUND FWD CARGO COMPARTMENT, ZONE 130 - FLOOR PANEL 131AF DELAMINATED. REMOVED FLOOR PANEL 131AF IAW AMM 53-22-14-000-001. FABRICATED NEW PANEL…
- 17 Apr 2010
Power Supply, inoperative
DURING A NON ROUTINE CHECK, FOUND EMERGENCY LIGHT AT 13WL INOPERATIVE. MX REPLACED POWER SUPPLY AND FUNCTIONAL CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.
- 12 Apr 2010
Power Supply, inoperative
DURING A NON ROUTINE CHECK, FOUND THE EMERGENCY PATH LIGHT AT ROW 13WL INOPERATIVE. MX REPLACED POWER SUPPLY AND OPS CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.
- 4 Jan 2009
Epsu, inoperative
EMERGENCY SEAT PATH LIGHTS SEAT ROW 18-21 ARE INOPERATIVE, REPLACED EPSU 13WL AND CHECKS GOOD. (K)
- 20 Sep 2008
Lamp, inoperative
EMERGENCY EGRESS LIGHTING TEST FAILS. RELAMPED EXIT SIGN, RESET POWER SUPPLIES 11WL, 12WL, 13WL. REPLACED EPSU 10WL, CHECKS OK.
- 9 Feb 1998
Skin Valve, inoperative
FOLLOWING TAKEOFF, CREW UNABLE TO PRESSURIZE THE AIRCRAFT. RETURNED TO MCO AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE AVIONICS EQUIPMENT COOLING…
- 30 Jan 1998
Skin Valve, failed
FOLLOWING TAKEOFF, CREW WAS UNABLE TO PRESSURE THE AIRCRAFT. DIVERTED TO LAX AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE AVIONICS EQUIPMENT COOLING…
- 13 Dec 1997
Bulb, failed
DURING TEST OF CABIN EMERGENCY LIGHTS, EMERGENCY EXIT SIGNS AT SEAT ROWS 11, 12, LEFT, AND RIGHT DID NOT ILLUMINATE. MAINTENANCE REPLACED BULBS. OPERATIONAL…
- 12 Dec 1997
Valve, faulted
DURING CLIMB, RECEIVED VENT SKIN VALVE FAULT AND UNABLE TO PRESSURIZE AIRCRAFT. DIVERTED TO MKE AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE SKIN AIR…
- 8 Dec 1997
Valve, failed
DURING CLIMBOUT, RECEIVED VENT SKIN VALVE FAULT AND UNABLE TO PRESSURIZE THE AIRCRAFT. AIRCRAFT DIVERTED TO PHX AND LANDED WITHOUT INCIDENT. MAINTENANCE…
- 12 Dec 1996
Window, shattered
CAPTAIN'S WINDSHIELD OUTER PANE SHATTERED AT FL350. RETURNED TO MEM AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE WINDOW, OPERATIONAL CHECK OK.
- 26 Nov 1996
Power Supply, discharged
DURING LINE MAINTENANCE ALL OF FIRST CLASS EMERGENCY FLOOR PROXIMITY LIGHTS FOUND INOPERATIVE. MAINTENANCE REPLACED POWER SUPPLY 110WL-1, OPS CHECKED OK.
- 19 Sep 1996
Support, corroded
DURING IL CHECK, FOUND CORROSION ON THE AFT GALLEY FLOOR SUPPORT BETWEEN FRAMES 67 AND 68 AT THE LEFT AFT ENTRY DOOR SILL. REPAIRED SUPPORT PER EA 32-106351.
- 17 Feb 1996
Tr Unit, malfunctioned
DURING LANDING, THE NR 1 ENGINE FLAMED OUT AFTER COMING OUT OF SECOND THRUST REVERSER ENGAGEMENT AND ENGINE RESTARTED DURING TAXI INTO GATE. GROUND…
- 6 Dec 1995
Longeron, corrosion
DURING 1C1 MAINTENANCE VISIT, FOUND CORROSION ON STRINGER 41R BETWEEN FRAMES 33-34. REPAIRED STRINGER PER EA 32-104389.
- 19 Feb 1995
Flt Contl Unit, inoperative
DURING CLIMB-OUT, FLIGHT CONTROL UNITS NR 1 AND NR 2 FAILED. RESET CIRCUIT BREAKERS, NO HELP. DECISION WAS MADE TO RETURN TO MSP. REPLACED FLIGHT CONTROL…
- 10 Jan 1995
Computer, failed
DURING CLIMB-OUT FROM DTW, RECEIVED 'VENT SKIN VALVE' FAULT. UNABLE TO PRESSURIZE AIRCRAFT. RETURNED TO DTW AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED…