- 1987
service difficulty reports
29 reports
- 29 Aug 2014
Engine, damaged
NUMBER 1 ENG OIL QTY LOSS DOWN TO ZERO, PRESS DECREASE FOLLOWED SHORTLY THEREAFTER. SHUTDOWN ENG & DIVERTED. APPROX 35 PSI WHEN ENG SHUTDOWN DECISION WAS…
- 21 Aug 2014
Unknown, malfunctioned
ON TAKEOFF, RT MAIN GEAR FAILED TO RETRACT. RAN QRH, CYCLED GEAR, IT CAME UP. CONTINUED FLIGHT. PERFORMED GVI OF RT MLG CHECKED GOOD. INTERROGATED PSEU ALL…
- 23 Jun 2014
Flap, cracked
LEFT HAND INBD FLAP APPEARS CRACKED. CUT OUT CRACK IAW SRM. REQUIRES HFEC TO VERIFY REMOVAL OF CRACK. PERFORMED HFEC TO VERIFY REMOVAL OF ALL DAMAGE. NO…
- 23 Jun 2014
Skin, cracked
DURING WALK AROUND, FOUND LT WING OTBD SLAT CUT OUT PANEL FWD LT CORNER, NR 5 SLAT CUT OUT PANEL CRACKED. PERFORMED HFEC INSPECTION IAW NDT SPM 06-10-01 &…
- 30 Oct 2013
Unknown, odor
FUEL ODOR IN COCKPIT. APU HAD NO PRESENCE OF LEAKS. APU STARTED WITH NO ODOR NOTICED. ACFT OK FOR SERVICE.
- 13 Aug 2013
Control Panel, inoperative
ON ELECTRICAL SYS CONTROL PANEL, EMERGENCY POWER "OFF" LIGHT WILL NOT ILLUMINATE. R & R ESCP, OPS CHECKED GOOD IAW AMM 24-08-02.
- 7 Jun 2013
Wire Harness, failed
REJECT TAKEOFF, RNWY 36L AT APROX 60 KTS FOR NR 2 ENG EXCEEDANCE WITH EGT 1055. ACARS DATA SHOWS JUST AFTER REACHING TAKEOFF POWER A SUDDEN EGT INCREASE AT A…
- 4 May 2013
Bulb, malfunctioned
NR 1 ENGINE OIL TEMP WENT INTO RED ON DEPARTURE THEN YELLOW X. RETURNED TO DEPARTURE. R & R NR 1 ENG OIL TEMP BULB.
- 8 Mar 2013
Support, cracked
CENTER MAIN WHEEL WELL LT, MOST FWD LT- ANGLE STIFFENER WEB SUPPORT DOUBLER FOR SPOILER PUSH ROD HAS A CRACK FORMING ON BOTTOM EDGE OF FASTENER HOLE. REMOVED…
- 8 Mar 2013
Doubler, cracked
CENTER MAIN WHEEL WELL RT MOST FWD LT-ANGLE STIFFENER WEB SUPPORT DOUBLER FOR SPOILER PUSH ROD HAS MULTIPLE CRACKS FORMING ON THE RADIOUS TOP TO BOTTOM. R & R…
- 8 Mar 2013
Angle, cracked
CENTER WHEEL WELL FWD BULKHEAD LT UPPER CORNER FWD OF AILERON TRIM DRUM TEE ANGLE CRACKED IN RADIOUS. CRACK IS APPROX .400" LONG. CRACK HAS BEEN VERIFIED BY…
- 25 Oct 2012
Wire Harness, chafed
WITH T/O POWER SET, GOT AT APPROX 100 KIAS, A LEVEL 1 ALERT ENG 1 EXCEEDENCE AND NR 1 EGT HIGH (984) REJECTED TAKEOFF AND RAN QRH. DURING TAXI IN AT IDLE (N1…
- 4 Jul 2012
Bottle, empty
THE L1 DOOR ASSIST EMERGENCY BOTTLE IS EMPTY. RAMP PERSONNEL OPENED THE L1 DOOR WITH EMERGENCY HANDLE FROM THE OUTSIDE. RESET DOOR ASSIST BOTTLE AND DOOR ,…
- 29 Apr 2011
Skin, cracked
NOSE GEAR LT DOOR EXT SURFACE SHOWING 3" LONG CRACK ALONG 2ND WEB. REMOVED LT NOSE GEAR FWD DOOR, ACCOMPLISHED HFEC ON SUBJECT AREA, MARKED END OF CRACK. MFG…
- 24 Feb 2011
Valve, false activation
PASSING 11,000' ON DESCENT HAD A NR 1 ENG FIRE INDICATION. USED QRH PROCEDURES FIRE INDICATION OUT AND REPLACED "A" FIRE LOOPS DETECTORS FOR FAN, CORE, AND…
- 7 Jan 2010
Sensor, malfunctioned
REJECTED TAKEOFF DUE TO ENGINE EXCEEDANCE, NR 3 N1 AT 131.7%. EXCEEDANCE OCCURED WHILE INITIALLY SETTING POWER FOR TAKEOFF. AIRSPEED <50 KNOTS. VIA 3 SHOWED…
- 18 Nov 2005
Indication Sys, malfunctioned
OAK - LEFT MAIN GEAR UNSAFE IN UP POSITION ON BOTH MAIN GEAR INDICATOR AND SYNOPTIC DURING DESCENT. ACCOMPLISHED RED TAB PROCEDURES, BOTH INDICATIONS NML.…
- 6 May 2005
Loop, shorted
LEVEL 2, NR 2 MANIFOLD FAIL ALERT DURING CRUISE, MEL 06MAY05. RELEASED FOR SERVICE PER MEL/CDL: 36-23-01-02. NR 2 MANIFOLD FAIL DETECTION LOOP INOP. MX MUST…
- 2 Sep 2004
Connector, miswired
AT C-CHECK, NR HYD SYS SHUTOFF VALVE FAILED THE OP'S CK. THE ELECTRIC ELEVATOR SHOV FAILED TO MOVE TO THE CLOSED POSITION. NR 3 ELEVATOR OFF ALERT SHOWS. T/S…
- 1 May 2004
Bulb, faulty
ENG 1 OIL TEMP HIGH, TEMP 226; ABOVE RED LINE. READJUSTED POWER, TEMP REMAINED ABOVE RED LINE. SHUT DOWN NR 1 ENGINE AND LANDED. OIL TEMP SLOWLY RETURNED TO A…
- 18 Feb 2004
Proximity Switch, malfunctioned
ON TAKEOFF OUT OF OAK, SLATS DID NOT RETRACT. ALERT FOR SLAT DISAGREE. RAN THE QRH CHECKLIST AND RETURNED TO OAK. CYCLED TWICE. CHECKED PSEU & FCC 1 & 2.…
- 30 Aug 2000
Bearing, corroded
RT AND LT HORIZONTAL STAB PIVOT BEARINGS CORRODED DUE TO LACK OF GREASE CAUSED BY PLUGGED GREASE PARTS AROUND BEEPING SURFACE AREA.
- 8 Feb 2000
Blade, damaged
ON T/O, FLEW THROUGH FLOCK OF BIRDS, NR 1 ENG START TO VIB. VIB SUBSIDE BELOW 65 DEG N1. RETURN TO SFS. *S/D* REMOVED AND REPLACED DAMAGED BLADES (5) PER MM…
- 5 Feb 2000
Seat Track, cracked
SNRM 246 - UPPER FUSELAGE SEAT TRACK BASE CRACKED AT BS 965, RBL 28.0. REWORKED AND SPLICE PLATES FABRICATED, PAINT AND WET INSTALLED PER SRM 53-70-00 FIG VOL…
- 5 Mar 1999
Wire, melted
APU GENERATOR FEEDER CABLE SHORTING OUT WHERE IT PASSES THRU BS 2007 - PRESSURE BULK HEAD. REMOVD AND REPLACED C PHASE CABLE AND THE PRESSURE SEAL FITTING ASSY.
- 8 Apr 1997
Switch, malfunction
ALL 4 GEAR LIGHTS AT F/O AND S/O PANEL REMAINED RED AFTER RAISING HANDLE. RECYCLED TWICE TO GET LIGHTS TO GO OUT, FEFI 32-30AA. FELT LIKE GEAR CAME UP EACH…
- 1 Mar 1997
Banjo Fitting, cracked
N 00192, RT NR 4 BANJO FITTING FWD MID HOLE HAS A CRACK INDICATION FWD FLANGE, FWD DIRECTION. REF EO 8-5510-7-3314, COMPLIED WITH EA 8-5530-32533 OVERSIZE…
- 26 Feb 1997
Skin, cracked
NR 0488 48, FOUND 2 CRACKS IN THE CONSTANT SECTION OF THE HORIZONAL STABILIZER. CRACK NR 1 IN RT UPPER PLANK NR 7 (P/N 7228-1), CRACK IS .250 INCH LONG NR 7…
- 24 Apr 1995
Cylinder, failed
AFTER TAKEOFF HYD SYS NR 3 ELEV LIGHT CAME ON SECOND OFFICERS PANEL IN CONJUNCTION WITH LOUD BANG AND CORRESPONDING LOSS OF SYS NR 3 HYD QTY (DOWN TO ONE GAL)…