N308UA
1987 Boeing 737-322 standard FAA →
reservations
earlier registrations
1 past record
- 1987
service difficulty reports
53 reports
- 12 May 2008
Channel, cracked
CRACKS WERE FOUND AT THE FOLLOWING LOCATIONS: STR 15L SPLICE CHANNEL STA 360, STR 11L & 10L CLIPS STA 360, STR 11L & 12L CLIPS STA 294.5, INTERCOSTAL WEB STR…
- 1 Apr 2008
Unknown, unknown
FLIGHT DIVERTED DUE TO CRACKING NOISE IN FRONT OF A/C. *S/D* COULD NOT FIND CAUSE OR DUPLICATE NOISE.
- 7 Mar 2008
Skin, delaminated
LT INBD MID FLAP T/E LWR SKIN DELAM 18" FROM OUTBOARD EDGE. MAJOR REPAIR: REPAIR ACCOMPLISHED.
- 15 Dec 2007
Light, inoperative
RIGHT OVERWING EMERGENCY LIGHT INOP. FOUND LAMP BURNED OUT. LAMP REPLACED. SYSTEM OPS CHECKED GOOD.
- 17 Sep 2007
Light, inoperative
EXIT PATH LIGHTING EEL STRIPS INOP AT SEAT 1B & DOOR 2L INOP. REPLACED INVERTER.
- 11 Sep 2007
Steering Sys, malfunctioned
NWS PROBLEMS: WHEN CENTERED IT DRIFTS TO THE LEFT OCCASIONALLY. ALSO SEEMS TO BIND. FOUND STEERING METERING VALVE FAULTY. REPLACED THE STEERING METERING VALVE…
- 6 Sep 2007
Aileron, binding
AILERONS SLIGHT BINDING WHEN COMING OUT OF A RIGHT TURN.
- 24 Aug 2007
Skin, cracked
FUSELAGE SKIN CRACKED AT STA 938 AND 1FT ABOVE STRINGER 25L. CRACK STARTS FROM SKIN RADIUS AND EXTENDS BEYOND RIVET HOLE. APPROX LOCATION IS 1FT FWD OF WATER…
- 19 Aug 2007
Skin, cracked
FUSELAGE SKIN CRACKED AT STA 938 AND 1FT ABOVE STRINGER 25L.CRACK STARTS FROM SKIN RADIUS AND EXTENDS BEYOND RIVET HOLE, APPROX LOCATION IS 1FT FWD OF WATER…
- 18 Aug 2007
Light, inoperative
FLOOR EEL LIGHTS INOP FROM ROW 15 ON BACK. REPLACED LIGHT AT ROW 21, OPS CK GOOD.
- 9 Jul 2007
Unknown, unknown
PILOT REPORTED HEAVY ELEVATOR. COULD NOT DUPLICATE ISSUE. NO FINDINGS.
- 23 Jun 2007
Warning Light, illuminated
RTFL DUE TO ILLUMINATED WING BODY OVERHEAT LIGHT. FOUND PACK EXHAUST DUCT FROM AFT HEAT EXCHANGER COMING APART. REPLACED DUCT.
- 14 Jun 2007
Actuator, faulty
RTFL DUE TO LOSS OF LEFT ENGINE BLEED. FOUND FAULTY BLEED AIR REGULATOR. REPLACED BLEED AIR REGULATOR.
- 9 Jun 2007
Feeder Cable, inoperative
AFT SECTION OF EEL FLOOR STRIP INOPERATIVE. [06-22-07] REPLACED FEEDER CABLE, CK OK.
- 29 May 2007
Overheat Sys, activated
FLIGHT DIVERTED DUE TO RIGHT WING BODY OVERHEAT INDICATION. [06-22-07] FOUND FAULTY OVERHEAT DETECTOR ELEMENTS. REPLACED DETECTOR ELEMENTS M271 AND M356.
- 3 Apr 2007
Light, shorted
AFT CABIN EEL LIGHTS INOP FROM ROW 15 AFT TO AND INCLUDING EEL STRIP IN FRONT OF AFT GALLEY CART STOWAGE COMPARTMENT. FOUND EEL STRIP AT ROW 21 SHORTED,…
- 27 Dec 2006
Flap, stuck
FLAPS STUCK AT 1 POSITION AFTER TAKEOFF. DECLARED EMERGENCY. FAILED FLAP POSITION INDICATOR. FOUND LEFT SYNCHRO BAD. REPLACED INDICATOR ON A/C. REPLACED LEFT…
- 28 Sep 2006
Light, loose
EMERGENCY EXIT FLOOR LIGHT STRIP IS LOOSE AT ROW 15. REPLACED EEL STRIP.
- 23 Sep 2006
Battery, inoperative
EMERGENCY LIGHT STRIP LIGHTS INOP FROM ROW 15 AND AFT. *S/D* REPLACED 2 BATTERY PACKS AND ONE POWER SUPPLY.
- 7 Jul 2006
Smoke Detector, inoperative
CARGO SMOKE DETECTION INOP. FAILED FIRE DETECTION CONTROL SYSTEM PANEL. REPLACED FIRE DETECTION CONTROL SYSTEM PANEL. FOUND "CPLD/SWITCH" BOARD DAMAGED BEYOND…
- 20 Jan 2006
Light, inoperative
FLOOR EEL LIGHTS INOP FROM ROW 15 ABC TO THE AFT AND INCLUDING THE AFT GALLEY EEL FLOOR LIGHTS.
- 9 Dec 2005
Wire, arced
CAPT UPPER LT PITOT HEAT CB AT P13-3 C1 INSIDE WIRE ARCED TO GROUND WHEN OPENING PANEL FOR INSPECTION. WIRES BURNT THRU AND SEPERATED AT P18-3 C1 CIRCUIT…
- 27 Jul 2005
Skin, cracked
APPROXIMATE 1.5 INCH CRACK IN FUSELAGE AT LOWER AFT RADIUS OF DOOR 1R. REPAIRED DOOR 1R LOWER AFT CORNER REF SRM 53-10-01 PAGE 207.
- 14 Apr 2005
Transmission, leaking
NR 8 TRANSMISSION LEAKING, INPUT FROM THE TRANSMISSION HOUSING WHEN TRANSMISSION REMOVED TO BE REPLACED, POSSIBLE CAUSE RETAINER WASHER AND OR NUT FAILED.…
- 11 Apr 2005
Door Frame, cracked
FWD GALLEY DOOR, AFT LWR CORNER FRAME IS CRACKED AT FASTENER HOLE 2 EA PLACES. REPLACED FRAME.
- 11 Apr 2005
Skin, gouged
FWD CARGO DOOR CUTOUT, FWD SIDE AT APPROXIMATELY MID POSITION WAS FOUND TO HAVE DEEP GOUGE. INSTALLED 25 IN X 27 IN, TRIPLER REPAIR.
- 11 Apr 2005
Attach Fitting, corroded
LT HORIZONTAL STAB REAR SPAR UPPER AFT LUG HAS CORROSION AROUND BOLT HOLE ON AFT FACE OF LUG. REMOVED CORROSION AND REPAIRED LUG.
- 10 Apr 2005
Channel, corroded
AFT CABIN FLOOR SUPPORT HAT CHANNEL CORRODED AT STA 993 RBL 14 TO 44 WL 208. REPLACED HAT CHANNEL SECTION.
- 9 Apr 2005
Crossbeam, cracked
AFT PIT CARGO DOOR-SECOND FROM BOTTOM CROSS BEAM WEB IS CRACKED. INSTALLED NESTED DOUBLER L-ANGLE AND STRAP REPAIR TO WEB.
- 9 Apr 2005
Intercostal, cracked
AFT CARGO DOOR T-CHORD INTERCOSTAL AND WEB CRACKED AT BS 798 IN LINE WITH 2ND DOOR STOP FROM THE LOWER END. ACCOMPLISHED. INSTALLED NESTED DOUBLER L-ANGLE AND…
- 9 Apr 2005
Door Frame, cracked
AFT CARGO DOOR FWD BS 795 FRAME WAS FOUND CRACKED IN LINE WITH 2ND DOOR STOP FROM TOP. INSTALLED U-CHANNEL REPAIR WITH RADIUS BLOCKS AT UPPER AND LOWER FLANGES.
- 6 Apr 2005
Skin, damaged
AFT CARGO DOOR CUTOUT FWD EDGE 20 INCHES FROM LOWER DOOR SILL, SUSTAINED DAMAGE MEASURING .2187 INCHES DEEP BY 4 INCHES LONG. INSTALLED TRIPLER EXT FUSE SKIN…
- 4 Apr 2005
Door Frame, cracked
DOOR 1R LOWER FRAME CRACKED (LOWER AFT CORNER). REPLACED FRAME.
- 1 Apr 2005
Crease Beam, corroded
CABIN CREASE BEAM CORRODED AT STA 294.5 RIGHT TO STA 328 RIGHT WL 207, RBL 60. REPLACED CREASE BEAM.
- 1 Apr 2005
Skin, dented
AFT FUSELAGE DENT AT STA 996 FOUR INCHES ABOVE STR 14L. REMOVED DAMAGED AREA AND INSTALLED DOUBLER.
- 1 Apr 2005
Floorbeam, damaged
AFT CABIN FLOORBEAM HAS EXCESSIVE MATERIAL LOSS OF 15 PERCENT TO 88 PERCENT STA 947 LBL 43 TO RBL 52. REPLACED T-CAP.
- 1 Apr 2005
Floorbeam, corroded
FLOORBEAM HAS LIGHT SURFACE CORROSION LOCATED STA 294.5 RT RBL 38. REPLACED HAT CHANNEL.
- 31 Mar 2005
Crease Beam, corroded
AFT CABIN CREASE BEAM RBL 57, WL 208.1 CORRODED IN NUMEROUS LOCATIONS FROM STA 947.5 TO STA 990. REPLACED CREASE BEAM.
- 30 Mar 2005
Skin, worn
UPPER FUSELAGE SKIN WORN AT STA 868 AT LBL 5 INCHES FROM DORSAL FIN SEAL WEAR. REPAIR STRAPS, FILLERS AND WEAR STRIP INSTALLED EXTERNAL SKIN AT DORSEL FIN…
- 29 Mar 2005
Floorbeam, corroded
AFT CABIN FLOORBEAM STA 986 RBL 16 TO RBL 28 WL 208 IS CORRODED. REPAIR ANGLE AND FLOOR BEAM T-CAP REPLACED.
- 29 Mar 2005
Floorbeam, corroded
CABIN FLOORBEAM UPPER SURFACE LIGHT CORROSION AT STA 312 AT RBL 8 WL 208. REPLACED TEE CHORD.
- 29 Mar 2005
Floorbeam, corroded
AFT CABIN FLOORBEAM T-CAP HAS CORROSION AT STA 967 LBL 17 TO RBL 12. REPLACED TEE CAP.
- 2 Dec 2004
Overheat Loop, failed
DIVERTED TO SLC DUE TO WING BODY OVERHEAT INDICATION. DISCREPANCY FOUND TO BE NR 2 ENGINE, STRUT CAVITY OVERHEAT DETECTOR ELEMENT FAULT. REPLACED OVERHEAT…
- 21 Nov 2004
Overheat Loop, failed
DIVERTED TO PIT DUE TO WING BODY OVERHEAT INDICATION. DISCREPANCY FOUND TO BE NR 2 ENGINE, STRUT CAVITY OVERHEAT DETECTOR ELEMENT FAULT. REPLACED OVERHEAT…
- 26 Aug 2004
Smoke, detected
ACRID SMOKE IN THE CABIN. CHECKED ALL CABIN LIGHTS AND ALL GALLEY EQUIPMENT, RAN BOTH PACKS, RECIRC FAN AND ENG BLEEDS, CHILLERS AND OVENS. VISUAL CHECK FOR…
- 19 Jan 2002
Odor, detected
AIRCRAFT RETURNED TO FIELD DUE TO RUBBER SMELL IN CABIN. NO ROOT CAUSE WAS FOUND. INSPECTED WHEEL WELLS, CABIN SERVICE AND LIGHTING. ALSO, RAN BOTH ENGINES…
- 9 Mar 2001
Skin, dented
DENT ON FUSELAGE AFT OF DOOR 1L AT STA 392, WL 210, AND STRINGER 16L NEEDS PERMANENT REPAIR. THIS IS CONSIDERED A MAJOR REPAIR. ACCOMPLISHED NON-DESTRUCTIVE…
- 9 Mar 2001
Frame, cracked
LEFT HAND OVERWING FRAME BS 616L IS CRACKED. REPAIRED OVERWING FRAME BS 616L. ACCOMPLISHED MAJOR REPAIR.
- 23 Jan 2001
Bellcrank, broken
LEFT SIDE INBOARD LEADING EDGE FLAP STUCK IN DOWN POSITION AFTER TAKEOFF. *S/D* FOUND BROKEN BELLCRANK. REPLACED THE BELLCRANK.
- 9 Sep 2000
Computer, malfunctioned
GROUND PROXIMITY WARNING SYSTEM INDICATION. *S/D* REPLACED GROUND PROXIMITY WARNING SYSTEM COMPUTER (P/N: 965-0976-003-104-104) AND TESTED. PASSES WITH NO…
- 25 Aug 2000
Control Box, failed
RIGHT WING-BODY OVERHEAT DETECTION SYSTEM INOPERATIVE. *S/D* REPLACED COMPARTMENT OVERHEAT CONTROL UNIT, WING-BODY OVERHEAT DETECTION SYSTEM TEST NORMAL.
- 24 Aug 1999
Valve, failed
UNABLE TO PRESSURIZE BEYOND .8 PSI DIFFERENTIAL AT 10,000 FT WITH APU BLEED OFF AND RIGHT PACK TO HIGH. *S/D* RIGHT HAND FLOW CONTROL AND MODULATION VALVE…
- 13 Jun 1997
Indicator, malfunctioned
PER CREW, AFTER EXTENDING FLAPS TO 5 DEGREES, FLAPS LOCKED OUT. UNABLE TO MOVE UP OR DOWN. CYCLING TRAILING EDGE FLAP CIRCUIT BREAKER, NO HELP. NEEDLES ARE…