N305UA
Drs Technologies SENTRY HP FAA →
registration
earlier registrations
1 past record
- 1987
NTSB
- 17 May 2005
incident, Denver CO
- 21 Aug 1990
incident, Los Angeles CA
- 29 Oct 1987
incident, Chicago IL
service difficulty reports
39 reports
- 21 Jun 2008
Oxygen Mask, leaking
CREW REPORT: F-O O2 MASK INFLATABLE HARNESS LEAKING - NOTE: OBSERVER AND CAPT MASKS ARE GOOD. SWAPPED FO'S MASK WITH FIRST OBS MASK. FO'S MASK CHKS OK PER…
- 18 May 2008
Strap, cracked
THE FOLLOWING CRACKS WERE AT VERTICAL STRAP STA 348 STR 16L, INTERCOSTAL CLIP STA 360 STR 11L, INTERCOSTAL CLIP STA 294.5 STR 11L AND INTERCOSTAL WEB STA…
- 18 May 2008
Frame, damaged
STA 294.5 FRAME AT STR 11L HAS TOOLING MARK.
- 18 May 2008
Strap, cracked
THE FOLLOWING CRACKS WERE AT VERTICAL STRAP STA 348 STR 16L, INTERCOSTAL CLIP STA 360 STR 11L, INTERCOSTAL CLIP STA 294.5 STR 11L AND INTERCOSTAL WEB STA…
- 18 May 2008
Frame, damaged
STA 294.5 FRAME AT STR 11L HAS TOOLING MARK. REPAIRED PER UA-EVA-71570 AND REO-L01074. THIS IS A TIME LIMITED REPAIR FOR 12 MONTHS. BOEING MUST ISSUE A NEW…
- 24 Apr 2008
Structure, damaged
FOUND STA 906 STR 26L HAS DAMAGE. INSTALLED REPAIR AT STA 90 6 STR 26L.
- 22 Apr 2008
Skin, damaged
FOUND DAMAGED SKIN AT STA 907 STR 26L. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED SKIN. INSTALLED DOUBLER, TRIPLER & STRUCTURUAL FILLER REPAIR.
- 16 Apr 2008
Fitting, leaking
CREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. FOUND FIRST OBSERVERS O2 MASK LEAKING AT QUICK DISCONNECT FITTING, REPLACED MASK AND STOWED PER…
- 13 Apr 2008
Slide, out of position
1R DOOR ESCAPE SLIDE SLID OUT OF CONTAINER. ACCOMPLISHED INSPECTION OF DOOR SLIDE INSTALLATION DOOR 1R SLIDE CHECKED NORMAL. AC OK FOR SERVICE.
- 27 Mar 2008
Plate, cracked
FLAP STAINLESS STEEL WEAR PLATE ON RIGHT FUSELAGE FAIRING AFT OF WHEEL WELL IS CRACKED APPROX 1.5 INCH AT FWD LOWER SECTION. REPLACED STAINLESS STEEL WEAR…
- 8 Mar 2008
Oxygen System, low
CREW O2 LOW. SERVICED OXYGEN SYSTEM.
- 4 Feb 2008
Smoke Detector, malfunctioned
CARGO DETECTION SUPPRESSION PANEL FWD PIT FAIL LIGHTS ILLUMINATED. MODULE INDICATING BOTH B AND ONE A LOOP INOPERATIVE. REPLACED 1A AND 2B SMOKE DETECTORS.
- 31 Jan 2008
Microphone, inoperative
FIRST OFFICER`S O2 MASK MICROPHONE INOP. REPLACED OXYGEN MASK.
- 31 Jan 2008
Microphone, inoperative
OBSERVER`S O2 MASK MICROPHONE INOP. SWAPPED TO FIRST OFFICERS POSITION PER MEL.
- 9 Nov 2007
Connector, burned
F/O ADI BENCH CONNECTOR D2425 PIN 7 IN BURNED. REPLACED EADI AND BENCH CONNECTOR.
- 28 Sep 2007
Door Frame, cracked
CABIN FWD GALLEY SERVICE ENTRY DOOR CUTOUT AFT LWR JAMB AREA CRACKED. MAJOR REPAIR ACCOMPLISHED: INSTALLED DOUBLER REPAIR.
- 25 Sep 2007
Skin, dented
RIGHT EXT FUSELAGE STA 320, 1-2 INCHES ABOVE STR 18R, ABOUT 10 INCHES BELOW FWD GALLEY DOOR, A .093" DEEP 2" WIDE DENT. MAJOR REPAIR: PERMANENT DOUBLER REPAIR…
- 11 Sep 2007
Flap, malfunctioned
CREW COMMENTS: FLAPS STOPPED AT 27 DEGREES AND WOULD NOT MOVE MORE OR LESS. REPLACED FLAP INDICATOR UNIT. FLAP LOCKOUT OCCURRED BECAUSE THERE WAS A F LAP…
- 2 Aug 2007
Wire, shorted
RIGHT MAIN GEAR INDICATION FAULT. FOUND SHORTED WIRING IN THE INDICATION SYSTEM. FOUND UPPER LOCK SENSOR RED WIRE SHORTED- REPLACED BOTH UP LOCK AND DOWN LOCK…
- 19 Mar 2007
Light, inoperative
EMERGENCY SLIDE LIGHT INOP AT DOOR 1L. [SUP 4-17-07] RELAMPED.
- 19 Mar 2007
Cable, faulty
EEL LIGHTS INOP AFT OF ROW 16. CLEANED LIQUID FROM EEL TRACK. REPLACED RIBBON CABLE.
- 19 Mar 2007
Light, inoperative
EEL LAMP INOP ROW 15. REPLACED EEL LAMP.
- 31 Jan 2007
Light, inoperative
ROW 16 ON BACK, EMERGENCY EXIT LIGHTS DON'T WORK. REPLACED POWER STRIP.
- 9 Jun 2006
Oil System, obstructed
NR 1 ENGINE SHUTDOWN DUE TO LOW OIL PRESSURE, LOW OIL QUANTITY AND HIGH OIL TEMPERATURE. THE CAUSE WAS A RED PROTECTION CAP HAD NOT BEEN REMOVED AND BECAME…
- 27 Mar 2006
Power Supply, inoperative
FOUND EEL LIGHTS FROM ROW 3-9 INOP.
- 27 Mar 2006
Power Supply, inoperative
EMERGENCY EXIT SIGNS ABOVE LT OVERWING HATCH AND LOWER FWD CORNER OF LT OVERWING HATCH INOP.
- 27 Mar 2006
Wire, damaged
EEL LIGHTS INOP FROM ROW 15 AFT TO AND INCLUDING EEL STRIP IN FRONT OF AFT GALLEY CART STOWAGE COMPARTMENT.
- 8 Jan 2006
A/C Pack, inoperative
LEFT PACK INOP. REMAINING PACK DELIVERING AIR AT 120 DEGREES AND COULD NOT BE COOLED. CONTROL CABIN DUCT OVERHEAT SWITCH FAILED. REPLACED SWITCH S11. NO…
- 2 Dec 2005
Wire, damaged
FIRST CLASS FLOOR EEL AND GALLEY STRIP EEL LIGHT IS INOP. REPLACED FEEDER CABLE.
- 16 Aug 2005
Skin, cracked
DENT FWD AND BELOW DOOR 2L.
- 23 Feb 2005
Floorbeam, corroded
CORROSION ON FWD LT CABIN FLOORBEAM AT STA 294.5 LBL 37-53. ACCOMPLISHED. BLENDED OUT DAMAGE AND INSTALLED ANGLE/STRAP REPAIR.
- 23 Feb 2005
Pressure Panel, cracked
STA 664 PRESSURE DECK IS CRACKED AT APPROXIMATELY LBL 30. ACCOMPLISHED. INSTALLED DOUBLER REPAIR.
- 16 Mar 2004
Target, out of adjust
RETURNED TO THE FIELD DUE TO A CARGO DOOR INDICATION. ADJUSTED TARGET. THE TARGET CAN BE DAMAGED/MISALIGNED DURING THE BAG LOADING PROCESS. THIS IS THE…
- 21 Sep 2003
Skin, dented
FWD CARGO PIT DOOR EXTERNAL SKIN, AFT LOWER QUADRANT-HAS NUMEROUS DENTS. MAJOR REPAIR ACCOMPLISHED, INSTALLED DOUBLER REPAIR.
- 25 Dec 2002
Warning Light, illuminated
AFT CARGO LIGHT CAME ON JUST BEFORE V1. RETURN TO FIELD.
- 28 Aug 1998
Annunciator, failed
DOOR 1L LIGHT ILLUMINATED. *S/D* REPLACED DOOR WARNING ANNUCIATOR MODULE.
- 18 Feb 1998
Mechanism, lack of lube
CABIN DOOR WARNING LIGHT ILLUMINATED. *S/D* CHECKED OPERATION OF DOOR 1L. CLEANED AND LUBED LATCH ROLLERS AND OPERATING MECHANISMS, DOOR OP CHECKED GOOD.
- 12 Aug 1996
Strip, damaged
EMERGENCY ESCAPE PATH LIGHTING INOP FROM ROW 13 TO THE AFT GALLEY. REPAIRED LIGHT STRIP AND TRIMMED CARPET, CHECKS OK.
- 6 Jun 1996
Coupler, failed
SEVERAL UNCOMMANDED RUDDER MOVEMENTS, DESCENDED TO LOWER ALTITUDE. *S/D* YAW COUPLER WAS REPLACED. SHOP FOUND YAW COUPLER RATE GYRO FAULTY, CHECKS OK.