N304WA
1985 Boeing 737-347 standard FAA →
earlier registrations
1 past record
- 1985
service difficulty reports
24 reports
- 2 Apr 2005
Fire Loop, faulty
APU FIRE WARNING LIGHT/ALARM BELL IN FLIGHT APPROX 1 TO 2 MINS AFTER APU SHUTDOWN IN FLIGHT AT 10 TO 12,000 FT ALT FIRE BOTTLE USED. REMOVED APU SHROUD, APU…
- 11 Oct 2004
Skin, dented
FUSELAGE SKIN DENTED AT STA 827 BETWEEN STR 26R - 28R. REPAIRED IAW ERA 093986-14.
- 18 Feb 2003
Hose, leaking
ON ARRIVAL DEN FOUND FUEL LEAKING FROM RT ENGINE. INSP FOUND MAIN FUEL LINE FROM PYLON TO ENG FUEL PUMP LEAKING AT SWEDGED END / PYLON SIDE. REPLACED SAME.
- 13 Feb 2003
Fire Loop, unserviceable
DURING PUSHBACK APU FIRE WARNING CAME ON APU SHUTDOWN AND INDICATION EXTINGUISHED APPROXIMATELY 2 MINUTES LATER. FIRE INDICATION RETURNED AND REMAINED ON.…
- 11 Feb 2003
Control Module, failed
AT 8000 FT APU FIRE LIGHT AND BELL SOUNDED, C/W PROC LIGHT STILL ON. AIR TURNBACK TO OAK. REPLACED FIRE DETECTOR CONTROL MODULE.
- 29 Oct 2002
Spar, corroded
DURING OVERHAUL THE NR 1 MID-FLAP WAS FOUND WITH CORROSION IN THE REAR SPAR LOWER CHORD. REPAIR PER ER/A 417872-14.
- 1 Apr 2002
Beam, corroded
CORROSION WAS FOUND ON THE CROWN BEAM LUG BORES ON THE #1 AND #2 PYLONS. THE BORES WERE OVERSIZED TO REMOVE THE CORROSION AND REPAIR BUSHINGS WERE INSTALLED.…
- 22 Mar 2002
Skin, delaminated
UPPER SKIN OF THE OUTBOARD SPOILER WAS FOUND DELAMINATED IN TWO AREAS. REPAIR PER ER/A 411104-14 NORDAM EWO E0037119 REV I/R.
- 18 Jun 2001
Skin, damaged
THE FUSELAGE BELLY SKIN WAS GOUGED, DENTED AND PUNCTURED AT SEVERAL LOCATIONS BETWEEN FS 400 & 470 AND BETWEEN STRINGERS 26L & 26R.
- 5 Jun 2001
Web, cracked
DURING INSPECTION PER SB 737-53A1173 REVISION 3, FOUND COCKPIT FLOOR WEBS JUST AFT OF 178 BULKHEAD CRACKED.
- 31 Mar 2001
Attach Fitting, broken
DURING GEAR EXTENSION THE NOSEGEAR DID NOT EXTEND. THE VALVES COULD BE HEARD SHIFTING BUT THE NOSEGEAR REMAINED UP. THE GEAR WAS CYCLED 3 TIMES WITHOUT MOVING…
- 1 Mar 2001
Circuit Breaker, malfunctioned
AT TOP OF DESCENT ALL COCKPIT INSTRUMENTS AND INDICATORS EXPERIENCED A MOMENTARY LOSS OF POWER - ON ENGINE GENERATORS, VISUAL CONDITIONS. POWER WAS RESTORED…
- 13 Jan 2001
Coalescer Bag, odor
BIRD STRIKE NR 2 ENGINE IN CLIMBOUT. HIT BIRD AT ABOUT 500 FT AGL. ENGINE PARAMETERS NORMAL, BAD ODOR IN AIRCRAFT. PERFORMED BIRD STRIKE INSPECTION PER MM…
- 11 Dec 1999
Wire, broken
FIRST CLASS LAV SMOKE DETECTOR INOP. REPLACED BROKEN WIRES AT SWITCH DETECTOR.
- 26 Oct 1999
Pcu, failed
AT FL370, MACH .76 THE ACFT EXPERIENCED AN UNCOMMANDED YAW, (TWO SEPARATE SHARP INPUTS). YAW DAMPER SWITCH TURNED OFF. MTC IN PROGRESS REPLACING RUDDER PCU,…
- 5 Oct 1999
Unknown, odor
PAX AT 2C SMELLED SLIGHT ODOR IN CABIN, F/O REPORTED A FAINT ODOR, BUT COULD NOT RECOGNIZE WHAT TYPE. RECIRCULATION FAN AND CABIN BALLAST LIGHT TURNED OFF. NR…
- 23 Sep 1999
Switch, out of adjust
DURING FLAP EXTENSION HAD L/E INTRANSIT LIGHT FOR NR 4 SLAT AND L/E FLAPS/SLAT INTRANSIT LIGHT ON FWD PANEL. WITH FLAPS AT 15 DEG THERE WAS AN INCREASE IN AIR…
- 3 Feb 1999
Overheat Light, illuminated
ON APPROACH COS, NR 1 ENGINE OVERHEAT LIGHT ILLUMINATED. CREW DISCHARGED BOTH BOTTLES, LIGHT REMAINED ILLUMINATED EVEN AFTER ENGINE SHUTDOWN. PARTS ARRIVING…
- 28 Dec 1998
Line, leaking
AIR TURNBACK DUE TO ELECTRICAL SMELL IN CABIN. MTC TROUBLESHOT AND FOUND THE LEFT PACK WAS OVERHEATING. ITEM THEN FWD TO MCO. FOUND HYDRAULIC LINE LEAK.…
- 7 Mar 1998
Battery Charger, damaged
NORMAL BLOWER POPPED CIRCUIT BREAKER. LEFT PACK TRIP TWICE. NR 1 GENERATOR VOLT/FREQUENCY ZERO. ELECTRICAL SMELL IN CABIN. FOUND BATTERY CHARGER BURNT.…
- 30 Nov 1997
Prox Sensor, failed
UNABLE TO RETRACT GEAR. REPLACED PROX SENSORS ON NOSE GEAR AND RT MLG, PERFORMED GEAR SWING.
- 30 Mar 1997
Smoke Detector, failed
FWD LAV SMOKE BELL WARNING AFTER PUSH OUT. REPLACED FWD LAV SMOKE DET.
- 15 Nov 1995
Frame, cracked
THE C-1 DOOR, LWR AFT FRAME HAS A 2.5 INCH LONG CRACK IN THE OUTBOARD RADIUS BELOW STOP NUMBER 4 AND OUTBOARD OF THE LOWER TORQUE TUBE. THE LOWER FWD FRAME…
- 14 Nov 1995
Eel Power Supply, discharged
BOTH OVERWING EMERGENCY LIGHTS INOP. REPLACED POWER SUPPLY, OPERATION NORMAL.