- 2008
service difficulty reports
30 reports
- 24 Jun 2020
Battery Pack, inoperative
DURING INSPECTION, FOUND EMERGENCY LIGHTS INOPERATIVE AT RT OVERWING WINDOW AND SEATS 10-14 RT. R & R BATTERIES FOR RT OVERWING ESCAPE WINDOW AND SEATS 10-14…
- 26 Nov 2019
Bulkhead Web, cracked
(LOG 1377182) DURING INSPECTION FOUND CRACK IN CENTER WING REAR SPAR VAPOR WEB ON RBL 40.00. REPAIRED CRACK REF B737 SRM 57-10-10 REPAIR 4.
- 4 Nov 2019
Lens, damaged
(LOG 1345765) DURING INSPECTION FOUND THRESHOLD LIGHT LENS / COVER DAMAGED. REPLACED LENS.
- 21 Jun 2019
Battery Pack, inoperative
DURING INSPECTION, FOUND LEFT OVERWING EXIT DOOR EMERGENCY LIGHTS INOPERATIVE. REPLACED THE BATTERY M1168 PER B737 AMM 33-51. OP CKS GOOD.
- 18 Feb 2019
Terminal, shorted
DURING EMERGENCY LIGHT CHECK FOUND GALLEY FLOOD EMERGENCY LIGHT OUT. T/S TO EMERGENCY CEILING LIGHT L1417 TERMINAL SHORTING TO GND. REPOSITION TERMINAL AND…
- 6 Feb 2019
Skin Panel, cracked
DURING INSPECTION FOUND 1/2 CRACK ON GROUND SVC PANEL FUSELAGE SKIN. INSTALLED CATEGORY "A" PERMANENT REPAIR PER SRM 53-10-15 REPAIR 4.
- 14 Oct 2018
Battery Pack, inoperative
(LOG 5181344) DURING INSPECTION FOUND FUNCTIONAL CHECK EMERGENCY LIGHTING, SEAT MOUNTED LIGHT FAILED TEST POWERED BY M1669. M1670 & M1672 POWER PACK. R/R…
- 27 Jan 2018
Attach Fitting, corroded
RIGHT MLG FWD TRUNNION ATTACH FITTING OTBD LOWER POINT HAS CORROSION COMING FROM BETWEEN THE LUG AND BUSHING, ON THE INBD AND OTBD FACES. REPAIRED IAW SRM…
- 27 Jan 2018
Attach Fitting, corroded
RIGHT MLG FWD TRUNNION ATTACH FITTING, OTBD UPPER POINT HAS CORROSION COMING FROM BETWEEN THE LUG AND BUSHING, ON THE OTBD FACE. REPAIRED IAW SRM 57-20-90,…
- 27 Jan 2018
Attach Fitting, corroded
RIGHT MLG FWD TRUNION ATTACH FITTING, INBD LOWER POINT HAS CORROSION COMING FROM BETWEEN THE LUG AND BUSHING ON THE INBB FACE. REPAIRED IAW SRM 57-20-90,…
- 27 Jan 2018
Attach Fitting, corroded
RIGHT MLG FWD TRUNNION ATTACH FITTING, INBD UPPER POINT HAS CORROSION COMING FROM BETWEEN THE LUG, AND BUSHING, ON THE INBD FACE. REPAIRED IAW SRM 57-20-90,…
- 27 Jan 2018
Attach Fitting, corroded
RIGHT MLG FWD TRUNNION ATTACH FITTING INBD UPPER POINT HAS EVIDENCE OF CORROSION COMING FROM BETWEEN THE LUG, AND BUSHING ON THE OTBD FACE. REPAIRED IAW SRM…
- 19 Jan 2017
Floorbeam, corroded
DURING INSPECTION, FOUND CABIN FLOORBEAM CORRODED AT BS 986.5 LBL 44. MAINTENANCE REPAIRED THE FLOORBEAM IAW SRM 53-70-51 REPAIR 4.
- 15 Jan 2017
Shield, corroded
DURING INSPECTION FOUND AFT CARGO COMPARTMENT CARGO DOOR AFT SHIELD AT STATION 847 TO STATION 867, STRINGER 25R HAS CORROSION. MAINTENANCE REMOVED AND…
- 15 Jan 2017
Stiffener, corroded
DURING INSPECTION FOUND CABIN FLOORBOARD SUPPORT STIFFENER CORRODED AT BS947.5 + 3" LBL 53. MAINTENANCE LOCATED AND DRILLED PART & IAW SRM 51-40-05 AND…
- 14 Jan 2017
Angle, corroded
DURING INSPECTION FOUND AFT CARGO COMPARTMENT LEFT SIDE Z ANGLE FROM STATION 727B TO STATION 727D STRINGER 25L HAS MULTIPLE AREAS OF CORROSION. MAINTENANCE…
- 14 Jan 2017
Angle, corroded
DURING INSPECTION FOUND AFT CARGO COMPARTMENT LT SIDE Z ANGLE FROM STATION 747 TO 787 STRINGER 25L HAS MULTIPLE AREAS OF CORROSION. MAINTENANCE REPAIRED LT…
- 14 Jan 2017
Angle, corroded
DURING INSPECTION FOUND AFT CARGO COMPARTMENT LT SIDE Z ANGLE FROM STATION 727D TO STATION 747 STR 25L HAS MULTIPLE AREAS OF CORROSION. MAINTENANCE REPAIRED…
- 14 Jan 2017
Angle, corroded
DURING INSPECTION FOUND AFT CARGO COMPARTMENT LT SIDE Z ANGLE FROM STATION 787 TO STATION 827 STRINGER 25L HAS MULTIPLE AREAS OF CORROSION. MAINTENANCE…
- 12 Jan 2017
Angle, corroded
DURING INSPECTION, FOUND AFT CARGO BAY ANGLE FROM BS 727 TO 727B, STRINGER 25R HAS MULTIPLE AREAS OF CORROSION. MAINTENANCE REPAIRED THE ANGLE IAW SRM…
- 12 Jan 2017
Angle, corroded
DURING INSPECTION, FOUND AFT CARGO BAY RT ANGLE FROM BS 727D TO 767, STRINGER 25R HAS MULTIPLE AREAS OF CORROSION. MAINTENANCE REPAIRED THE ANGLE IAW SRM…
- 12 Jan 2017
Angle, corroded
DURING INSPECTION, FOUND AFT CARGO BAY ANGLE FROM BS 727B TO 727D, STRINGER 25R HAS MULTIPLE AREAS OF CORROSION. MAINTENANCE REPAIRED THE ANGLE IAW SRM…
- 12 Jan 2017
Floor Panel, corroded
DURING INSPECTION FOUND AFT CARGO COMPARTMENT FLOOR PANEL 140DF HAS MULTIPLE AREAS OF CORROSION ALONG EDGE OF PANEL. MAINTENANCE FABRICATED FLOOR PANEL 140DF…
- 10 Jan 2017
Floor Panel, corroded
DURING INSPECTION, FOUND AFT CARGO BAY FLOOR PANEL 140BF HAS MULTIPLE AREAS OF CORROSION ALONG EDGES OF PANEL. MAINTENANCE FABRICATED A NEW FLOOR PANEL IAW…
- 9 Jan 2017
Floor Panel, corroded
DURING INSPECTION, FOUND FORWARD CARGO BAY FLOOR PANEL 120AF CORRODED SEVERAL AREAS ALONG FORWARD EDGE. MAINTENANCE CUT AND DRILLED A NEW FLOOR PANEL IAW SRM…
- 3 Mar 2016
Doubler, cracked
DURING INSPECTION FOUND AREA OF THE GROUND POWER RECEPTACLE SURROUND DOUBLER WAS CRACKED JUST BELOW THE LOWER HIGE LOCATION. MAINTENANCE REPAIRED IAW 534599-14.
- 27 Oct 2015
Connector, loose
DURING INSPECTION FOUND SEAT EMERGENCY LIGHT AT 12D INOPERATIVE. MAINTENANCE FOUND LOOSE CONNECTOR. SECURED CONNECTOR, OPS NORMAL.
- 21 Feb 2014
Seat Track, cracked
DURING INSPECTION, FOUND FUSELAGE CABIN SEAT TRACK BS 727B SPLICE STRAP AT LBL 45.5 HAS CRACK DAMAGE. MAINTENANCE C/W ERA 523330-14AD, REV ORIG SECTION L,…
- 3 Jan 2012
Frame, damaged
WORKING ERA 484067-14 REV B HAD TO REMOVE DOUBLERS FROM PREVIOUS REPAIR INSTALLED ON SAME ERA WHICH FAILED DTA. REMOVED DOUBLES AND FOLLOWED INSTRUCTION REF…
- 16 Jul 2010
Skin, damaged
BAGGAGE LOADER HIT SIDE OF A/C AT STA 440 AT STR AT 24R (DL73W101923).