- 23 Sep 1997
Bulb, failed
GREEN LIGHT INOP ON RIGHT GEAR. REMOVED AND REPLACED BULBS. (M)
- 26 Jul 1997
Hyd Pump, inoperative
LEFT HYD PUMP INOP. REMOVED AND REPLACED HYD PUMP. (M)
- 21 Jul 1997
Attitude Ind, dirty
CAPTAINS ATTITUDE INDICATOR HAS OIL FILM ON FACE, INSIDE, MAKES IT DIFFICULT TO SEE IN SOME LIGHT. REMOVED AND REPLACED LEFT ATTITUDE INDICATOR, OPS CHECKED…
- 27 May 1997
Transceiver, failed
WEATHER RADAR INOP. REMOVED AND REPLACED RADAR TRANSCEIVER. (M)
- 22 May 1997
Tail Pipe, fell off
RIGHT TAIL PIPE FELL OFF. REMOVED RIGHT JET PIPE COWLING TO FACILIATE INVESTIGATION OF DISCRIPTION NR 1, AML NR 505066. (M)
- 3 Mar 1997
Battery Pack, discharged
TWO EMERGENCY OVERHEAD LIGHTS INOP. REMOVED AND REPLACED BATTERY PACKS. (M)
- 20 Feb 1997
Screw X, out of adjust
NR 2 ENGINE DID NOT REACH TARGET TORQUE OF 100.5 PERCENT, ONLY REACHED 84 PERCENT. ADJUSTED SCREW 'X' IAW GARRETT MM AND GROUND RAN. (X)
- 28 Jan 1997
Electrical Syst, smoking
SAW AND SMELLED SMOKE COMING FROM UNDERNEATH FIRST OFFICER'S SKIRT PANEL. GROUND RAN ELECTRICAL SYSTEM ON GPU. COULD NOT DUPLICATE. AIRCRAFT TEST FLOWN, ALL…
- 18 Sep 1996
Water Meth Syst, malfunctioned
WATER METHANOL SYSTEM CAUSES TORQUE SURGE. DEFERRED PER MEL 82-00-00. DM16329. PERFORMED OPERATIONAL CHECK OF WATER METHANOL SYSTEM, NO DEFECTS NOTED. OK FOR…
- 30 Nov 1995
Actuator, failed
RIGHT MAIN GEAR WOULD NOT RETRACT AFTER TAKEOFF. REMOVED AND REPLACED RT ACTUATOR IAW AMM 32-10-3. PERFORMED GEAR SWING, OPS CHECK GOOD. OK FOR SERVICE. (X)
- 11 Aug 1995
Switch Wire, broken
LANDING GEAR WILL NOT RETRACT. REPAIRED BROKEN WIRES ON NOSE OLEO SWITCH AND RESET PIN ON RELEASE VALVE. PERFORMED GEAR SWINGS. OPS CHECK GOOD. (M)
- 11 Jul 1995
Bushing, worn
AFTER TAKEOFF LEFT RUDDER PEDAL WOULD NOT MAKE MORE THAN ABOUT ONE THIRD OF TRAVEL REQ'D CAPTAIN AND FORWARD OFFICERS SIDES. RIGHT RUDDER PEDAL APPEARS TO…