N296AS
1977 Beech C90 FAA →
reservations
earlier registrations
1 past record
- 1977
NTSB
- 4 Jun 1983
incident, Portland OR
service difficulty reports
8 reports
- 22 May 2001
Actuator, failed
HEAT VALVE FAILED IN OPEN CAUSING RAW BLEED AIR TO ENTER CABIN. CABIN FILLED WITH SMOKE (IFE).
- 10 Apr 1996
Charger, failed
GUM - DURING SERVICE CHECK, EMERGENCY LIGHT CHECK, EXIT PATH LIGHTING FROM ROW 23 TO AFT BULKHEAD FADED AFTER 10-15 SECONDS, REMAINDER OF LIGHTING TESTED…
- 30 Dec 1995
Battery, discharged
GUM - ON SERVICE CHECK, FOUND AFT EXTERNAL EMERGENCY LIGHT AFT OF LEFT INBOARD FLAP INOP. MECHANIC REPLACED BATTERY PACK ASSY AND SYSTEM FUNCTION CHECK GOOD.…
- 23 Feb 1995
Temp Switch, failed
FLT 925 - GUM - AFTER TAKEOFF RIGHT AIR CONDITIONING PACK TRIPPED OFF. CREW PERFORMED ABNORMAL CHECK LIST AND COULD NOT RESET PACK. AIRCRAFT RETURNED BACK TO…
- 19 Jan 1995
Stringer, cracked
TNN - DURING 1/4D CHECK INSPECTION ON AIRCRAFT AT AIR ASIA, CRACKS WERE FOUND ON OUTER WING UPPER Z-STRINGER AT RIB ATTACHMENT HOLE IN THE FOLLOWING…
- 19 Jan 1995
Stringer, cracked
TNN - DURING 1/4D CHECK INSPECTION ON AIRCRAFT AT AIR ASIA, CRACKS WERE FOUND ON OUTER WING UPPER Z-STRINGER AT RIB ATTACHMENT HOLE IN THE FOLLOWING…
- 19 Jan 1995
Stringer, cracked
TNN- DURING 1/4D CHECK INSPECTION ON AIRCRAFT AT AIR ASIA, CRACK WAS FOUND ON LT OUTER WING UPPER VENT STRINGER AT RIB ATTACHMENT HOLE, S-13 AND WS 656.5. THE…
- 19 Jan 1995
Stringer, cracked
TNN - DURING 1/4D CHECK INSPECTION ON AIRCRAFT AT AIR ASIA, CRACKS WERE FOUND ON OUTER WING UPPER Z-STRINGER AT RIB ATTACHMENT HOLE IN THE FOLLOWING…