- 13 Apr 2004
Slide, leaking
SLIDE REMOVED FOR SCHEDULED CHANGE. REPAIR STATION TEARDOWN INDICATED THE INFLATABLE TUBE IS POROUS AND WILL NOT PASS TEST. UNIT IS NOT REPAIRABLE. LAST…
- 12 Jan 2004
Light, inoperative
EMERGENCY EXIT LIGHT IN COCKPIT INOPERATIVE. REMOVED AND REPLACED EMERGENCY EXIT LIGHT ASSY. IN FLIGHT COMPARTMENT IAW BMM 33-50-01.
- 14 Nov 2003
Power Supply, inoperative
MAIN CABIN DOOR, SERVICE DOOR AND FORWARD, BULKHEAD EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED POWER SUPPLY. (M)
- 1 Nov 2003
Lamp, burned out
EMERGENCY EXIT OVERWING LIGHT HAS 3 LAMPS INOPERATIVE. RELAMPED EMERGENCY OVERWING EXIT LIGHT IAW B727 MM 33-50-11. (M)
- 6 Oct 2003
Charger, failed
BATTERY CHARGER FOR L1 EMERGENCY EXIT LIGHTING NOT CHARGING. REMOVED AND REPLACED CHARGER UNIT PER MM 33-50-51. (M)
- 27 Oct 2002
Indicator, defective
ON TAXI OUT, THE INBOARD FLAP INDICATOR DISPLAYED ASSYMETRIC CONDITION. FLAPS LOCKED OUT. RETURNED TO GATE. RESET FLAP INDICATION SYSTEM IAW MM. OPS CHECK…
- 15 Oct 2002
Light, inoperative
PSM - FOUND EMERGENCY LIGHTS AT L1 AND R1 FAILED TO TEST. REMOVED AND REPLACED LIGHT ASSEMBLIES AT L1 AND R1. (M)
- 2 Feb 2002
Power Supply, discharged
FLT 182 - IAD - RIGHT EXTERNAL AFT BODY FAIRING EMERGENCY LIGHT INOPERATIVE. TROUBLESHOT SYSTEM AND FOUND FAULTY POWER SUPPLY. REMOVED FAULTY POWER SUPPLY AND…
- 2 Feb 2002
Power Supply, faulty
FLT 182 - IAD - RIGHT EXTERNAL AFT BODY FAIRING EMERGENCY LIGHT INOPERATIVE. TROUBLESHOT SYSTEM AND FOUND FAULTY POWER SUPPLY. REMOVED FAULTY POWER SUPPLY AND…
- 22 Oct 2001
Power Supply, discharged
ORD - DURING LINE CHECK, FOUND EXTERIOR EMERGENCY LIGHT OUT. REMOVED AND REPLACED BATTERY POWER SUPPLY. (M)
- 22 Oct 2001
Power Supply, discharged
ORD - DURING LINE CHECK, FOUND AFT EXTERIOR EMERGENCY LIGHT OUT. REMOVED AND REPLACED BATTERY POWER SUPPLY. (M)
- 3 Jan 2001
Check Valve, failed
DURING TAKEOFF FROM MKE THE AIRCRAFT FILLED WITH SMOKE IN BOTH THE CABIN AND COCKPIT. THE FLIGHT CREW ABORTED THE TAKEOFF. THE AIRCRAFT WAS FERRIED TO MSP,…
- 1 Jan 2001
Wire, broken
THE OVERHEAD EMERGENCY LIGHT AT SEAT 24 STAYED ON AFTER THE POWERR IS WAS REMOVED AND THE SWITHC WAS TURNED OFF. REPAIRED BROKEN DISARM WIRE ON OVERHEAD…
- 18 Dec 2000
Gasper Fan, failed
DURING SHORT FINAL SMOKE APPEARED IN THE CABIN AND COCKPIT, THE GASPER FAN SEEMED TO BE THE SOURCE. THE GASPER FAN WAS SHUT OFF AND THE SMOKE CLEARED. REMOVED…
- 22 Nov 2000
Light, inoperative
DURING A MAINTENANCE LINE CHECK TWO LIGHTS WERE FOUND TO BE OUT ON THE EMERGENCY TRACK LIGHTING. RELAMPED EMERGENCY TRACK LIGHTING OPERATIONAL CHECKS GOOD.
- 21 Nov 2000
Valve, leaking
DURING SHORT FINAL APPROACH SMOKE ENTERED THE CABIN. THE PACKS WERE NOTICED TO BE RUNNING HOT PRIOR TO THIS OCCURANCE. MAINTENANCE REMOVED AND REPLACED THE 35…
- 22 Aug 2000
Sign, inoperative
DURING HEAVY MAINTENANCE INSPECTION THE RIGHT FORWARD EMERGENCY EXIT DOOR SELF LUMINOUS EMERGENCY SIGN WAS FOUND INOP. REMOVED AND REPLACED SIGN IAW B727 MM…
- 12 Aug 2000
Valve, inoperative
DURING TAKEOFF ROLL, THE NUMBER ONE ENGINE REMAINED AT IDLE. THE TAKEOFF WAS ABORTED. REMOVED AND REPLACED PRBC AND START BLEED CONTROL VALVE. OPERATIONAL…
- 28 Jul 2000
Fire Warning, activated
AT GATE, FIRE BELL STARTED SOUNDING RANDOMLY. ENGINES OFF, APU SHUTDOWN. BELL CUTOUT SWITCH WILL NOT SILENCE BELL. REMOVED AND REPLACED FIRE TEST SYSTEM A & B…
- 7 Jul 2000
Battery Pack, inoperative
DURING A MAINTENANCE LINE CHECK THE LEFT OVERWING EMERGENCY EXIT SIGNS WERE FOUND INOPERATIVE.REMOVED AND REPLACED THE LEFT EMERGENCY OVERWING EXIT SIGN…
- 2 Jul 2000
Start Valve, failed
DURING CRUISE FLIGHT THE NUMBER THREE ENGINE START VALVE OPEN WARNING LIGHT ILLUMINATED. THE CREW SHUT DOWN THE ENGINE PER C.O.M. PROCEDURES. THE ENGINE SATRT…
- 11 Jun 2000
Battery Pack, inoperative
DURING A MAINTENANCE LINE CHECK, THE RIGHT FORWARD EMERGENCY LIGHT WAS FOUND INOPERATIVE. REMOVED AND REPLACED BATTERY AT RIGHT FORWARD OVERWING EMERGENCY…
- 5 Jun 2000
Battery Pack, inoperative
DURING A MAINTENANCE LINE CHECK, THE OVERWING EMERGENCY EXIT SIGNS WOULD ILLUMINATE FOR ONLY 20 SECONDS. REMOVED AND REPLACED BATTERY PACK FOR THE LEFT…
- 2 Jun 2000
Battery Pack, inoperative
DURING A MAINTENANCE LINE CHECK, THE LEFT SIDE OVERWING EMERGENCY EXIT SIGNS WERE FOUND INOPERATIVE. REMOVED AND REPLACED BATTERY PACK ASSEMBLY AT THE LEFT…
- 22 May 2000
Fire Loop, malfunctioned
DURING CRUISE, THE NUMBER ONE ENGINE FIRE BOTTLE, SHUT DOWN ENGINE AND BLEW FIRE BOTTLE. THE FLIGHT CREW RETURNED TO AIRPORT OF ORIGIN. MAINTENANCE INSPECTED…
- 28 Apr 2000
Battery, intermittent
DURING A LINE MAINTENANCE CHECK, THE LEFT HAND OVERWING EMERGENCY EXIT SIGNS WERE FOUND TO FLASH THEN EXTINGUISH AFTER 30 SECONDS. THE EMERGENCY EXIT SIGNS ON…
- 15 Apr 2000
Light, inoperative
DURING A ROUTINE LINE CHECK, THE EMERGENCY PATH LIGHT MODULE AT THE R2 DOOR WAS FOUND INOPERATIVE. THE EMERGENCY PATH LIGHT PIG TAIL MODULE WAS REMOVED AND…
- 8 Apr 2000
Engine, malfunctioned
WHILE TAXIING OUT FOR TAKEOFF, THE SMOKE ENTERED THE CABIN. THE NUMBER ONE ENGINE EIGHT STAGE AIR DUCT DISCOVERED EXCESS AIR. THE NUMBER ONE ENGINE WAS…
- 4 Feb 2000
Prbc Valve, inoperative
DURING FLIGHT, THE NUMBER TWO ENGINE HAD A COMPRESSOR STALL UPON INCREASING POWER FROM IDLE ON LEVEL OFF AND ON DESCENT. INSPECTED THE NUMBER TWO ENGINE…
- 3 Feb 2000
Compressor, malfunctioned
DURING LEVEL OFF AND ON DESCENT, THE NUMBER TWO ENGINE UPON ADVANCING THRUST LEVERS EXPERIENCED COMPRESSOR STALL. ENGINE RUN CARRIED OUT. HOT AND COLD…
- 29 Jan 2000
Battery, discharged
DURING A LINE MAINTENANCE CHECK THE OVERWING EMERGENCY EXIT LIGHTS ON THE LEFT SIDE WERE FOUND INOPERATIVE. REMOVED AND REPLACED THE BATTERY PACK AT 18ABC.…
- 28 Jan 2000
Battery, discharged
DURING A LINE MAINTENANCE CHECK, THE AFT AIRSTAIR OVERHEAD EMERGENCY LIGHTS WERE FOUND DIM. REMOVED AND REPLACED THE BATTERIES. LIGHT OPERATIONALLY CHECKS…
- 23 Jan 2000
Switch, failed
ON TAKEOFF, THE AUTO PACK TRIP FAILED TO ARM. ABORTED TAKEOFF AT 80 KNOTS. FOUND EXCESSIVE WATER IN LINE TO THE NUMBER 2 AUTO PACK CIP SWITCH. PURGED LINE AND…
- 22 Jan 2000
Light, inoperative
DURING A LINE MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTING ON THE LEFT SIDE BY THE FORWARD GALLEY WAS FOUND INOPERATIVE. FOUND A BROKEN WIRE. SPLICED…
- 14 Jan 2000
Battery Pack, discharged
DURING A LINE MAINTENANCE CHECK, THE LEFT SIDE OVERWING EMERGENCY EXIT SIGN LIGHTS WERE FOUND INOPERATIVE. REMOVED AND REPLACED THE BATTERY PACK ABOVE SEATS…
- 6 Jan 2000
Lamp, inoperative
DURING A LINE MAINTENANCE CHECK, TWO LAMPS WERE FOUND BURNT OUT OF THE EMERGENCY FLOOR PATH LIGHTING STRIP. RELAMPED AND SYSTEM CHECKS NORMAL.
- 26 Dec 1999
Battery, discharged
DURING A LINE MAINTENANCE CHECK, THE EMERGENCY LIGHTS AT THE OVERWING EXITS WERE FOUND INOPERATIVE. FOUND BATTERY PACK AT M1090 TO BE LOW OF CHARGE. REMOVED…
- 7 Dec 1999
Prbc, lack of lube
ON FINAL APPROACH, THE NUMBER TWO COMPRESSOR STALLED WHEN POWER WAS ADDED. LUBRICATED PRBC VALVE IAW MM 720000. OPERATIONAL CHECK ON VALVE OK.
- 3 Dec 1999
Battery, discharged
DURING A LINE MAINTENANCE CHECK, THE AFT AIRSTAIRS EMERGENCY OVERHEAD LIGHT WAS FOUND VERY DIM. REMOVED AND REPLACED THE EMERGENCY OVERHEAD LIGHT BATTERIES.…
- 3 Dec 1999
Battery Pack, discharged
DURING A LINE MAINTENANCE CHECK, THE LEFT OVERWING EMERGENCY LIGHTS WERE FOUND INOPERATIVE. REMOVED AND REPLACED LEFT OVERWING EMERGENCY LIGHTS BATTERY PACK.…
- 28 Nov 1999
Valve, failed
TAKEOFF WAS ABORTED JUST SHY OF V1 DUE TO SMOKE IN THE COCKPIT. NO SMOKE NOTICED IN THE CABIN. REMOVED AND REPLACED FLOW MULTIPLIER PER MM 211211. RAN ALL…
- 14 Nov 1999
Fuel Line, leaking
UPON LEVEL OFF AT CRUISE ALTITUDE THE NUMBER TWO ENGINE SHUTDOWN. ALL INDICATIONS LOW. UPON INSPECTION FOUND FUEL LEAK AT THE PRESSURIZATION AND DUMP VALVE…
- 13 Nov 1999
Light, inop
DURING A LINE MAINTENANCE CHECK, THE WHITE FLOOR TRACK EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE AT SEAT ROW 32D. INSTALLED A NEW LAMP AT POSITION 32D,…
- 12 Oct 1999
Sidewall, loose
DURING TAKEOFF ROLL, A SIDEWALL PANEL CAME LOOSE ON THE RIGHT SIDE OF THE FIRST OFFICER'S SEAT JAMMING THE RIGHT RUDDER PEDALS. ABORTED TAKEOFF. INSTALLED…
- 7 Oct 1999
Light, inop
DURING HEAVY MAINTENANCE CHECK, RED FLOOR TRACK LIGHT INOPERATIVE AT AT SEAT 32D AREA. REPAIRED IAW B277 MM 335101.
- 7 Oct 1999
Bulb, failed
DURING HEAVY MAINTENANCE CHECK, CEILING EMERGENCY LIGHT INOP IN TAIL STAIR COMPARTMENT. REMOVED AND REPLACED LIGHT BULBS IN EMERGENCY LIGHT IAW B727 MM 331001…
- 26 Sep 1999
Intercoastal, elongated
DURING HEAVY MAINTENANCE CHECK STATION 330 TO 400 RBL 7 APPROXIMATELY, INTERCOSTAL HAS ELONGATED HOLES AT FLOORBEAM ATTACH ANGLE. REMOVED INTERCOASTAL IAW…
- 22 Sep 1999
Seat Track, corroded
DURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS IN THE FORWARD MAIN CABIN SEAT TRACK, STA 380 RBL 24. REMOVED CORROSION PER SRM 511006.…
- 22 Sep 1999
Floorbeam, corroded
DURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS ON FLOORBEAM TOP CAP AT STA 1070 JUST AFT OF L2 DOOR. REMOVED CORROSION FROM FLOORBEAM IAW…
- 15 Sep 1999
Stringer, corroded
DURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS IN EQUIPMENT AND ELECTRICAL BAY DOG HOUSE AREA, STR 24, AT BS 294. REMOVED CORROSION PER SRM…
- 15 Sep 1999
Bulkhead, corroded
DURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS IN LT WHEEL WELL FORWARD BULKHEAD AT BS 870, LBL 56 STIFFENER CORRODED NUMEROUS PLACES FROM…
- 14 Sep 1999
Floorbeam, corroded
DURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS APPROX FS 400 LBL 5 ON MAIN CABIN FLOOR STRUCTURE. REMOVED CORROSION FROM FLOORBEAM IAW B727…
- 14 Sep 1999
Floorbeam, corroded
DURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS APPROX FS 440 LBL 11 ON T CAP OF MAIN CABIN FLOOR STRUCTURE. REMOVED CORROSION FROM…
- 14 Sep 1999
Floorbeam, corroded
DURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS APPROX FS 440 BETWEEN RBL 6 AND 12 ON T CAP OF MAIN CABIN FLOOR STRUCTURE. REMOVED CORROSION…
- 14 Sep 1999
Floorbeam, corroded
DURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS APPROX FS 440 BL 0 ON T CAP OF MAIN CABIN FLOOR STRUCTURE. REMOVED CORROSION FROM FLOORBEAM…
- 14 Sep 1999
Floorbeam, corroded
DURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS APPROX FS 440 LBL 18 ON T CAP OF MAIN CABIN FLOOR STRUCTURE. REMOVED CORROSION FROM…
- 14 Sep 1999
Seat Track, corroded
DURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS APPROX FS 410 LBL 21 ON SEAT TRACK SUPPORT ANGLE OF MAIN CABIN FLOOR STRUCTURE. REMOVED…
- 14 Sep 1999
Skin, corroded
DURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS LT AC BAY CENTER WING LOWER SKIN AT BS 833 TO BS 838 BL 24L TO 30L. REMOVED CORROSION IAW…
- 27 Jul 1999
Light, inop
DURING A LINE MAINTENANCE CHECK, THE AFT ENTRY AIRSTAIR EMERGENCY EXIT LIGHT ASSEMBLY WAS FOUND INOPERATIVE. REMOVED AND REPLACED BATTERY HOLDER ASSEMBLY. OPS…
- 8 Jul 1999
Fire Loop, failed
DURING FLIGHT, THE NUMBER THREE ENGINE FIRE WARNING LIGHT ILLUMINATED. DISCHARGED BOTH ENGINE FIRE BOTTLES AND FIRE LIGHT REMAINED ON. RETURNED AIRCRAFT TO…
- 21 May 1999
Smoke Detector, inoperative
DURING A LINE MAINTENANCE CHECK, THE AFT RIGHT LAVATORY SMOKE DETECTOR WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED THE SMOKE DETECTOR. OPERATIONALLY…
- 14 Mar 1999
Battery Pack, discharged
DURING A LINE MAINTENANCE CHECK, AN EMERGENCY LIGHT IN THE AFT AIRSTAIR WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED THE BATTERY PACK IN THE AFT AIRSTAIR…
- 28 Feb 1999
Oven, smoking
DURING FLIGHT, THE AFT NR 1 OVEN EMITTED SMOKE MOMENTARILY WHEN SWITCHED ON. REMOVED AND REPLACED THE OVEN.
- 25 Jan 1999
Battery, discharged
DURING A LINE MAINTENANCE CHECK, THE AFT AIRSTAIR EMERGENCY LIGHTS WERE FOUND TO BE DIM. REMOVED AND REPLACED THE BATTERIES, OPERATIONALLY CHECKS GOOD.
- 17 Jan 1999
Windshield, failed
THE FIRST OFFICER'S R1 WINDSHIELD WAS SEEN TO SPARK IN THE TOP RIGHT CORNER. REMOVED AND REPLACED THE R1 WINDOW IAW MM 561111. LEAK AND OPERATIONAL CHECK GOOD.
- 31 Dec 1998
Deice Duct, blown
DURING CLIMBOUT, CREW OBSERVED ENGINE NUMBER 3 FIRE WARNING AFTER PASSING 10,000 FEET. NUMBER THREE ENGINE WAS SHUT DOWN PRECAUTIONARY AND FIRE BOTTLE WAS…
- 17 Dec 1998
Battery Pack, discharged
DURING A LINE MAINTENANCE CHECK, THE EMERGENCY LIGHTS OUTSIDE OF THE L1 AND R1 DOORS ON THE SIDE OF THE AIRPLANE WERE FOUND TO BE INOPERATIVE. REMOVED AND…
- 12 Dec 1998
Battery Pack, discharged
DURING A LINE MAINTENANCE CHECK, THE SLIDE LIGHTS AT THE R1 AND L1 DOORS WERE FOUND TO BE INOPERATIVE. REMOVED AND REPLACED EMERGENCY BATTERY PACK,…
- 12 Dec 1998
Battery Pack, discharged
DURING A LINE MAINTENANCE CHECK, THE SLIDE LIGHTS AT THE R2 AND L2 DOORS WERE FOUND TO BE INOPERATIVE. REMOVED AND REPLACED EMERGENCY BATTERY PACK,…
- 23 Sep 1998
Light, inoperative
DURING A LINE MAINTENANCE CHECK, THE AFT AIRSTAIR OVERHEAD EMERGENCY LIGHT AT THE BOTTOM OF THE STAIRS WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED THE…
- 1 Sep 1998
Pressurization, malfunctioned
ON CLIMBOUT COULD NOT CONTROL THE CABIN PRESSURIZATION IN ANY MODE. PERFORMED AN OPERATIONAL CHECK OF THE PRESSURIZATION SYSTEM PER 3600 PAGE 501 AND…
- 14 Aug 1998
Seat Track, broken
DURING A HEAVY MAINT CHECK, A SEAT TRACK WAS FOUND BROKEN APPROX 4 INCHES LONG ON I/B SIDE OF TRACK AT STATION 720A WL 208 LBL 46. CUT OUT SEAT TRACK IAW SRM…
- 10 Aug 1998
Shear Web, cracked
DURING A HEAVY MAINT CHECK, A CRACK WAS FOUND IN THE UPPER CHORD OF THE SHEAR WEB BETWEEN FLOORBEAMS STA 700 AND 720. REMOVED CRACKED SHEAR WEB IN UPPER…
- 7 Aug 1998
Skin, cracked
DURING A HEAVY MAINT CHECK, X-RAY INSPECTION OF THE LEFT HAND ELEVATOR REVEALED SEVERAL CRACKS AT THE TRAILING EDGES. CUT OUT CRACKED AREA OF SKIN IAW SRM…
- 7 Jun 1998
Control Valve, inoperative
ON CLIMBOUT THROUGH APPROXIMATELY 25,000 FEET, THE AIRCRAFT CABIN STARTED AN UNCONTROLLABLE CLIMB. INITIATED COM PROCEDURES AND CABIN REACHED APPROXIMATELY…
- 14 May 1998
Compressor, stalled
COMPRESSOR STALL ON ENGINE RUNUP, TAKEOFF ABORTED. INSPECTED ALL THREE ENGINES IN ACCORDANCE WITH 720000 FOR DAMAGE. NO DAMAGE FOUND. PERFORMED BLEED SHIFT…
- 9 Aug 1997
Power Supply, inoperative
THE OVERHEAD EMERGENCY EXIT LIGHTS WERE FOUND TO BE INOPERATIVE BETWEEN THE L-2 AND R-2 DOORS. REMOVED AND REPLACED POWER SUPPLY, LIGHT OPS CHECKED NORMAL IAW…
- 29 Jul 1997
Smoke Detector, failed
THE FORWARD LAV SMOKE DETECTOR CONTINUES TO SOUND AFTER RELEASING TEST SWITCH. REMOVED AND REPLACED SMOKE DETECTOR, OPS CHECKED GOOD.
- 20 Jul 1997
Battery Pack, discharged
THE LEFT FORWARD EXTERIOR EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. INSTALLED NEW BATTERY PACK FOR LEFT EXTERIOR EMERGENCY LIGHT, LIGHT CHECKED GOOD.
- 10 Jul 1997
Engine, failed
NUMBER 1 ENGINE FAILED IN FLIGHT AFTER ILLUMINATION OF NUMBER 1 LOW OIL PRESSURE/FILTER BYPASS LIGHT. FOUND N2 ROTOR NO LONGER LINKED TO GEARBOX. REMOVED AND…
- 24 Jun 1997
Support, corroded
DURING HEAVY MAINTENANCE VISIT, FOUND FLOOR SUPPORT FRAME CORRODED NEAR L-2 DOOR FLOOR AREA, STATION 1070 LBL 24 TO 65. REMOVED, FABRICATED, AND INSTALLED NEW…
- 12 Jun 1997
Seat Track, corroded
DURING HEAVY MAINTENANCE VISIT, FOUND CORROSION ON LEFT OTBD SEAT TRACK FROM STATION 1030 TO 1070. REMOVED AND INSTALLED NEW SEAT TRACK IAW B727 SRM 53-10-5,…
- 10 Jun 1997
Floorbeam, corroded
DURING HEAVY MAINTENANCE VISIT, FOUND FLOORBEAM AT STATION 1090 CORRODED. FABRICATED REPAIR IAW B727 SRM 53-10-8, 51-10-2, AND 53-10-2.
- 9 Jun 1997
Seat Track, corroded
DURING HEAVY MAINTENANCE VISIT, FOUND SPACING FOR RIGHT INBD SEAT TRACK STATION 400 TO 520 AND LEFT OTBD SEAT TRACK STATION 344 TO 500 NOT MAINTAINING 1 INCH…
- 8 Jun 1997
Seat Track, gouged
DURING HEAVY MAINTENANCE VISIT, FOUND GOUGED SEAT TRACK FROM STATION 420 TO 460, RBL 55. REMOVED, FABRICATED, AND INSTALLED NEW SEAT TRACK IAW B727 SRM…
- 8 Jun 1997
Seat Track, mis mfg
DURING HEAVY MAINTENANCE VISIT, FOUND LEFT INBOARD SEAT TRACK AT STATION 460 - 520 NOT CONFORMING TO 1 SPACING. REMOVED, FABRICATED, AND INSTALLED SEAT TRACK…
- 8 Jun 1997
Floorbeam, corroded
DURING HEAVY MAINTENANCE VISIT, FOUND THE FLOORBEAM AT STATION 369 RBL 12 TO LBL 24 CORRODED. REMOVED 38 SECTION OF UPPER FLOORBEAM, FABRICATED AND INSTALLED…
- 8 Jun 1997
Skin, corroded
DURING HEAVY MAINTENANCE VISIT, FOUND SKIN PILLOWING THRU RIVET PATTERN OF SKIN LAP 4 RIGHT FROM APPROXIMATELY STATION 700 TO 720. REMOVED, FABRICATED AND…
- 8 Jun 1997
Support, corroded
DURING HEAVY MAINTENANCE VISIT, FOUND FLOOR SUPPORT AT STATION 1110 TO 1130, LBL 18 CORRODED. REMOVED, FABRICATED AND INSTALLED NEW SUPPORT IAW B727 SRM…
- 8 Jun 1997
Angle, corroded
DURING HEAVY MAINTENANCE VISIT, FOUND CORROSION ON FLOOR SUPPORT LOCATED AT STATION 1110, LBL 0 TO 60. FABRICATED AND INSTALLED REPAIR ANGLES IAW B727 SRM…
- 8 Jun 1997
Seat Track, corroded
DURING HEAVY MAINTENANCE VISIT, FOUND CORROSION ON RIGHT SEAT TRACK AT STATION 720E. REMOVED AND INSTALLED NEW SEAT TRACK IAW B727 SRM 53-10-5, 51-10-2, AND…
- 7 Jun 1997
Floorbeam, corroded
DURING HEAVY MAINTENANCE VISIT, FOUND CABIN FLOORBEAM CORRODED AT STATION 380, RBL 12 TO 48. CUT OUT CORRODED AREA, FABRICATED AND INSTALLED REPAIR PER EO…
- 7 Jun 1997
Support, corroded
DURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON FLOOR SUPPORT AT STATIONS 344 TO 380, LBL 10 TO RBL 22. INSTALLED REPAIR IAW B727 SRM 53-10-8, 51-30-2,…
- 7 Jun 1997
Floor Web, corroded
DURING HEAVY MAINTENANCE VISIT, FOUND CORROSION UNDER FLOOR WEB AT STATION 360 TO 373, RBL 64. FABRICATED AND INSTALLED REPAIR DOUBLER IAW B727 SRM 51-40-2,…
- 7 Jun 1997
Seat Track, corroded
DURING HEAVY MAINTENANCE VISIT, FOUND CORROSION ON AFT GALLEY SEAT TRACKS FROM STATION 1090 TO 1130, LBL 45. REMOVED AND INSTALLED NEW TRACK IAW B727 SRM…
- 7 Jun 1997
Support, corroded
DURING HEAVY MAINTENANCE VISIT, FOUND CORROSION ON FLOOR SUPPORTS AT STATION 1030, RBL 12 TO LBL 12, AND LBL 24 TO LBL 65. REMOVED, FABRICATED, AND INSTALLED…
- 7 Jun 1997
Seat Track, corroded
DURING HEAVY MAINTENANCE VISIT, FOUND SEAT TRACK CORRODED STATION 378, RBL 22. REMOVED AND INSTALLED NEW SEAT TRACK IAW B727 SRM 53-10-2, 53-10-5, AND 51-30-2.
- 7 Jun 1997
Rib, cracked
DURING HEAVY MAINTENANCE VISIT, FOUND RIB LOCATED AT LEFT WING STATION 738.5 CRACKED ON THE UPPER FLANGE AT THE STRINGER 12 ATTACH POINT. REMOVED AND REPLACED…
- 6 Jun 1997
Bracket, cracked
DURING HEAVY MAINTENANCE VISIT, FOUND LEFT HORIZONTAL STABILIZER L2 BALANCE PANEL CENTER SUPPORT BRACKET CRACKED AT RIVET HOLE LOCATION. REMOVED, FABRICATED,…
- 5 Jun 1997
Angle, cracked
DURING HEAVY MAINTENANCE VISIT, FOUND THE RIGHT WING TRAILING EDGE PANEL SUPPORT ANGLES (2 EACH) CRACKED AT SUPPORT STRUTS BETWEEN SPOILER ACTUATORS NUMBER 12…
- 8 May 1997
Duct, cracked
LEFT PACK UNABLE TO MAINTAIN CABIN PRESSURE AT FL 240, DESCENDED TO 10,000 FEET AND CABIN PRESSURE STABILIZED. AIRCRAFT DIVERTED TO ALTERNATE AIRPORT. FOUND…
- 23 Mar 1997
Battery, discharged
FORWARD LAV SMOKE DETECTOR BEEPED. REMOVED AND REPLACED BATTERY AND TESTED NORMAL.
- 20 Mar 1997
Bulb, failed
L-2 DOOR EMERGENCY SLIDE LIGHT WAS FOUND INOP. REMOVED AND REPLACED BULB AND SYSTEM, FUNCTIONALLY CHECKED NORMAL.
- 13 Mar 1997
C1 Blades, damaged
AT APPROXIMATELY 50 FEET, FOD WAS INGESTED INTO THE NUMBER 1 ENGINE, THE ENGINE FAIL LIGHT ILLUMINATED WITH AURAL WARNING, AND THE NUMBER 1 ENGINE N1…
- 12 Mar 1997
Batteries, discharged
AFT AIRSTAIR OVERHEAD EMERGENCY LIGHTS FOUND DIM. REMOVED AND REPLACED BATTERIES AND OPS CHECKED GOOD.
- 12 Jan 1997
Coalescer Bags, contaminated
CREW REPORTED SMOKE IN CABIN. AIRCRAFT RETURNED TO GATE. REPLACED COALESCER BAGS, INSPECTED PNEUMATIC SYSTEM, PERFORMED ENGINE RUNS, AND NO DEFECTS NOTED.…
- 6 Jan 1997
Light, inoperative
AFT EMERGENCY TRACK LIGHT WAS FOUND INOP. REPLACED PIGTAIL ASSEMBLY, LENS, AND LAMP AND OPS CHECKED GOOD IN ACCORDANCE WITH MM 33-50-00.
- 3 Jan 1997
Bulb, failed
FOUND AFT AIRSTAIR EMERGENCY LIGHTS INOP. RELAMPED 3 EMERGENCY LIGHTS AND OPS CHECKED GOOD.
- 26 Dec 1996
Window Seal, not seated
COULD NOT HOLD PRESSURIZATION IN CABIN AT 25,000 FT, NOISE WAS HEARD AT L1 AND L2 AREA DURING CLIMBOUT. RETURNED TO LAS. RESEATED AND RETORQUED L1 WINDOW,…
- 7 Dec 1996
Battery Pack, discharged
L2 DOOR EMERGENCY EXIT SIGN INOP. REMOVED AND REPLACED BATTERY PACK FOR L2 DOOR EMERGENCY EXIT SIGN, OPS CHECK GOOD.
- 3 Dec 1996
Frame, corroded
DURING INSPECTION, CORROSION DAMAGE WAS DISCOVERED ON THE FUSELAGE SKIN AT BS 328 RT, JUST OUTBOARD OF THE NLG WHEEL WELL CUTOUT. ALSO, CORROSION WAS FOUND ON…
- 26 Sep 1996
Smoke Detector, intermittent
FORWARD LAVATORY SMOKE DETECTOR TEST BUTTON WAS FOUND INTERMITTENT. REMOVED AND REPLACED SMOKE DETECTOR AND OPS CHECKED GOOD.
- 22 Aug 1996
Skin, cracked
FOUND A SMALL CRACK IN SKIN ON THE C3 DOOR, LOWER AFT CORNER. REPAIRED CRACK IN ACCORDANCE WITH SRM 52-20-2.
- 13 Aug 1996
Floor Light, split
SECTION OF EMERGENCY FLOOR TRACK LIGHTING SPLIT FROM GALLEY CART TRAFFIC, NEAR AFT GALLEY AREA FORWARD OF 33D. REPLACED BAD SECTION OF TRACK LIGHTING IN AFT…
- 13 Aug 1996
Light, damaged
EMERGENCY FLOOR TRACK LIGHTING SPLIT IN SECTION NEXT TO SEAT 5D. REPLACED BAD SECTION OF TRACK LIGHTING. OPS CHECKED OK.
- 9 Aug 1996
Smoke Detector, inoperative
RIGHT AFT LAV SMOKE DETECTOR WILL NOT SHUT OFF. REMOVED AND REPLACED THE RIGHT AFT LAV SMOKE DETECTOR, OPS CHECKED GOOD.
- 19 Jul 1996
Lamp, inoperative
FOUND RIGHT SERVICE DOOR OVERHEAD EXIT SIGN LIGHTS INTERMITTENT. RELAMPED AND OPS CHECKED NORMAL.
- 19 Jul 1996
Lamp, inoperative
FOUND LEFT FORWARD OVERWING EXIT SIGN INTERMITTENT. RELAMPED AND OPS CHECKED NORMAL.
- 11 Jul 1996
Power Supply, inoperative
THE LEFT OVERWING EMERGENCY LIGHT WAS FOUND INOP. REPLACED BATTERY POWER SUPPLY ASSEMBLY AND OPS CHECKED OK.
- 3 Jul 1996
S-Duct, corroded
DURING MAINTENANCE INSPECTION, CORROSION WAS FOUND IN THE INLET OF THE S-DUCT ON ENGINE 2. REMOVED CORROSION, FABRICATED AND INSTALLED A REPAIR IN ACCORDANCE…
- 21 May 1996
Track Light, inoperative
FLOOR EMERGENCY TRACK LIGHTING WAS FOUND INOP AT SEATS 21 DEF. REPAIRED WIRES IN TRACK, OPS CHECK OK.
- 20 May 1996
Frame, damaged
WHILE ACCOMPLISHING AD 94-02-04, ELONGATED HOLES WERE FOUND IN THE BS 760 AND 783 FRAMES. REPAIRED HOLES IN ACCORDANCE WITH B727 SB53-197 AND BOEING TELEX…
- 10 May 1996
Angle, corroded
DURING HEAVY MAINTENANCE VISIT, LEVEL 2 CORROSION WAS FOUND ON AFT UPPER ATTACH ANGLE AT BS 351.2 RBL 24. REMOVED CORRODED ANGLE, FABRICATED AND INSTALLED NEW…
- 7 May 1996
Floor Beam, corroded
DURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON A FLOOR BOARD SUPPORT BEAM AT FS 1065, RBL 28. REMOVED CORROSION, FABRICATED AND INSTALLED A REPAIR IN…
- 20 Mar 1996
Smoke Det Batt, discharged
LEFT AFT LAV SMOKE DETECTOR WOULD NOT TEST. REMOVED AND REPLACED BATTERY IN LEFT AFT LAV SMOKE DETECTOR. DETECTOR OPS CHECKED GOOD.
- 26 Nov 1995
Switch, dirty
THE NUMBER ONE LEADING EDGE FLAP FAILED TO RETRACT AFTER TAKEOFF, AIRCRAFT RETURNED TO BASE. THE NUMBER ONE LEADING EDGE FLAP POSITION SWITCH AND ACTUATOR…
- 16 Nov 1995
Engine, failed
DURING TAKEOFF ROLL, THE NUMBER TWO ENGINE EXPERIENCED A CONTAINED FAILURE AND ENGINE PARTS WERE REPORTED DEPARTING THE AIRCRAFT. THE ENGINE WAS REPLACED. THE…
- 25 Oct 1995
Smoke Det Batt, discharged
THE RIGHT AFT LAV SMOKE DETECTOR WAS FOUND BEEPING CONSTANTLY. THE BATTERY VOLTAGE WAS FOUND LOW, REPLACED BATTERY AND DETECTOR TESTED GOOD.
- 6 Oct 1995
Eel Batteries, discharged
THE COCKPIT DOOR OVERHEAD EMERGENCY LIGHT TESTED VERY DIM. REMOVED AND REPLACED BATTERIES AND LIGHT TESTED GOOD.
- 23 Sep 1995
Eel Wire, damaged
LEFT SIDE FORWARD SECTION OF EMERGENCY TRACK LIGHTING WAS FOUND TO BE INOPERATIVE. REPAIRED SPLICE AT AFT SECTION OF FORWARD TRACK AND LIGHTING TESTED GOOD…
- 23 Aug 1995
Eel Battery Pack, discharged
THE RIGHT OVERWING EXTERIOR EMERGENCY LIGHT WAS FOUND INOPERATIVE, DURING A FUNCTIONAL TEST. CHARGED BATTERY PACK AND LIGHT TESTED GOOD.
- 23 Aug 1995
Eel Connector, loose
THE FORWARD OVERHEAD AISLE EXIT SIGN WAS FOUND INOPERATIVE, DURING FUNCTIONAL TEST. RESEATED THE CANNON PLUG ON EXIT SIGN AND THE LIGHT TESTED GOOD.
- 10 Aug 1995
Batteries, discharged
THE FORWARD AND AFT LEFT LAVATORY SMOKE DETECTOR EMITTED A CHIRPING SOUND WHILE EN ROUTE. REMOVED AND REPLACED BATTERIES IN THREE LAV SMOKE DETECTORS AND OPS…
- 25 Jul 1995
Eel Battery, discharged
FOUND THE EMERGENCY EXIT AISLE SIGN BETWEEN THE L-2 AND R-2 DOOR TO BE INOPERATIVE. REMOVED AND REPLACED BATTERY PACK M1095 AT THE AFT EMERGENCY AISLE EXIT…
- 18 Jul 1995
Eel Battery Pack, discharged
FOUND THE EMERGENCY EXIT LIGHTING ABOVE R-2 DOOR BLINKING REMOVED AND REPLACED R-2 DOOR BATTERY PACK IAW MM 33-50-71, SYSTEM TESTED GOOD.
- 9 Jul 1995
Eel Batteries, discharged
AFT AIRSTAIR EMERGENCY EXIT LIGHT ON VERY DIM. FOUND BATTERY PACK WITH LOW VOLTAGE AND SOME CORROSION ON TERMINALS. CLEANED TERMINALS AND INSTALLED NEW…
- 7 Jun 1995
Fire Wire, faulty
WHILE STARTING THE APU IN DFW THE FIRE WARNING LIGHT ILLUMINATED, BUT DID NOT RECEIVE THE WARNING BELL. THE FIRE HANDLE WAS PULLED AND ONE FIRE BOTTLE WAS…
- 27 May 1995
Eel Power Supply, failed
LEFT AFT OVERWING EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED POWER SUPPLY, EMERGENCY LIGHTS TEST GOOD.
- 5 May 1995
Skin, corroded
DURING C-CHECK, FOUND 3 DISHED RIVETS AND SKIN BULGES IN THE FUSELAGE BELLY SKIN, AT BODY STATION 680 BUTT SEAM BL3R. FABRICATED DOUBLERS AND FILLERS,…
- 23 Apr 1995
Retract Mech, malfunctioned
LANDING GEAR REQUIRED ONE RECYCLE TO GET NOSE GEAR TO COME DOWN. FIRST ATTEMPT MAIN LANDING GEAR INDICATED DOWN AND LOCKED, BUT NOSE DOORS AND GEAR REMAINED…
- 3 Mar 1995
Eel Battery Pack, discharged
FORWARD AISLE EMERGENCY EXIT SIGN IS INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK AT FORWARD AISLE EXIT SIGN. OPERATIONS CHECK GOOD.
- 1 Mar 1995
Overheat Line, broken
AFTER SHUT DOWN OF APU HAD FIRE INDICATION OF RED LIGHT IN FIRE SWITCH WITH EGT OF 550 DEGREES. PULLED FIRE SWITCH AND DISCHARGED BOTTLE. FIRE INDICATIONS…
- 25 Jan 1995
Smoke Det, discharged
MSP - AFT LAVATORY SMOKE DETECTOR INOPERATIVE. INSTALLED NEW BATTERY AND TESTED GOOD. (W)
- 23 Jan 1995
Valve, leaks
MSP - ACFT RETURNED TO GATE, CREW REPORTED SMOKE IN CABIN AND COCKPIT. FOUND THE PARKING BRAKE VALVE LEAKING SKYDROL INTO APU INTAKE. REPLACED VALVE AND…
- 19 Dec 1994
Packings, faulty
DEN - FLT 129 - NR 3 ENGINE PRECAUTIONARY SHUT DOWN DUE TO LOSS OF OIL TO ZERO QUANTITY. LOSS WAS APPROXIMATELY ONE-THIRD GALLON EVERY 15 MINUTES. FOUND FUEL…