service difficulty reports
21 reports
- 14 Aug 2007
Battery Pack, inoperative
LGA - EMERGENCY LIGHT AT FORWARD CABIN INOPERATIVE. REPLACED BATTERY PACK AT FORWARD GALLEY CEILING FOR EMERGENCY LIGHT AT FORWARD CABIN. SYSTEM GROUND…
- 21 Jul 2007
Coalescer Bag, disconnected
TUL INFLIGHT T2528/21JUL - DURING CLIMB FLIGHT ATTENDANT REPORTED ODOR AND SMOKE IN CABIN. RETURNED TO TUL AND LANDED WITHOUT INCIDENT. FOUND RIGHT COALESCER…
- 14 Sep 2006
Apu, inoperative
STL - CREW REPORTED SMOKE IN CABIN. RETURNED TO STL AND LANDED WITHOUT INCIDENT. FOUND APU HAD INGESTED OIL. REPLACED APU ON 16 SEPTEMBER AT DFW. SYSTEM…
- 22 Aug 2005
Pump, inoperative
DFW INFLIGHT T1296/22AUG - AIRCRAFT WOULD NOT TRANSFER FUEL FROM CENTER TANK. FORWARD BOOST PUMP CIRCUIT BREAKER POPPED ON TAKEOFF. RETURNED TO DFW AND LANDED…
- 2 Nov 2002
Battery Pack, discharged
DFW - DURING OVERNIGHT MAINTENANCE, TAIL COMPARTMENT EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 2 Jul 2002
Battery, loose
DFW - DURING OVERNIGHT MAINTENANCE, EMEREGNCY EXIT LIGHTS IN TAIL INOPERATIVE. RESEATED EMERGENCY EXIT LIGHT BATTERY. SYSTEM GROUND CHECKED NORMAL OPERATION.…
- 20 Feb 2002
Battery, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, COCKPIT AND FORWARD ENTRANCE AND GALLEY EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED COCKPIT AND FORWARD ENTRANCE AND…
- 7 May 2001
Wire, loose
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT AFT GALLEY INOPERATIVE. RE-SECURED EMERGENCY EXIT LIGHT WIRE AT BATTERY PACK. SYSTEM GROUND…
- 30 Apr 2001
Socket, defective
DFW - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT LIGHT AT SEAT 7D INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT SOCKET AT SEAT 7D. SYSTEM GROUND CHECKED NORMAL…
- 28 Mar 2000
Panel, corroded
TUL - FORWARD LAV SERVICE PANEL PAN HAS CORROSION ON INBOARD SURFACE FLANGE AROUND DUMP CHUTE AND BETWEEN PAN AND PAN STIFFENER. REPLACED PAN AND PAN…
- 5 May 1999
Light, inoperative
DFW - DURING MAINTENANCE, EMERGENCY EXIT PATH LIGHT AT OVERWING EXIT INOPERATIVE. REPLACED EMERGENCY PATH LIGHT STRIP. SYSTEM GROUND CHECKED NORMAL OPERATION.…
- 27 Jun 1996
Actuator, leaking
DFW - FLT 2012 - AFTER TAKEOFF DFW WHEN LANDING GEAR RETRACTED, NOSE LANDING GEAR DID NOT RETRACT AND NOSE GEAR UNSAFE LIGHT ILLUMINATED. EXTENDED LANDING…
- 28 May 1996
Cusp, corroded
TUL - FOUND CORROSION ON RIGHT CUSP AT FORWARD SERVICE DOOR. INSTALLED DOUBLER PER SRM 53-01 PAGE 2, SHEET 3, PER ESO 80554, DATED 5-21-96. (M)
- 20 May 1996
Seat Track, corroded
TUL - FOUND SEAT TRACK CORROSION BLENDED BEYOND MANUAL LIMITS FROM STATION 1060 TO STATION 1182, REF E58-4A 0095459, 0095471, 0095483. SPLICED IN NEW SECTION…
- 17 May 1996
Support, corroded
TUL - FOUND CORROSION ALONG FLOOR SUPPORT STATION 160 TO 200 AT CLIP NUT AREAS, CORROSION BEYOND LIMITS. REPLACED ANGLE SUPPORT. (M)
- 17 May 1996
Cusp, corroded
TUL - FOUND CORROSION ON RIGHT CUSP AT FORWARD SERVICE DOOR AREA STATION 160 TO 200 (CORROSION REMOVED AND BEYOND LIMITS FOR THICKNESS). INSTALLED DOUBLER PER…
- 17 May 1996
Cusp Fitting, corroded
TUL - FOUND CORROSION AT CUSP FITTING JUST AFT OF FORWARD SERVICE DOOR CUTOUT, (CORROSION REMOVAL BEYOND LIMITS). INSTALLED DOUBLER PER ESO NR 80559. (M)
- 16 May 1996
Seat Track, corroded
TUL - FOUND CORROSION ON SEAT TRACK NR 3 AT STATION 1195. INSTALLED PLUG IN SEAT TRACK AT STATION 1195 PER SRM 53-05 FIG 4A. (M)
- 16 May 1996
Seat Track, corroded
TUL - FOUND CORROSION ON TOP OF TRACK NR 1 AND GALLEY TIE DOWNS HAS INTERGRANULAR CORROSION IS FROM STATION 1212-1250. CUT OUT AREA THAT WAS BEYOND LIMITS AND…
- 16 May 1996
Seat Track, corroded
TUL - FOUND GALLEY TIE DOWN IN SEAT TRACK NR 1 HAS INTERGRANULAR CORROSION AT STATION 1210. CUT OUT AREA THAT WAS BEYOND LIMITS AND INSTALLED PLUG PER SRM…
- 15 May 1996
Jamb, corroded
TUL - FOUND CORROSION LEFT CUSP AT FORWARD ENTRY STATION 160 TO 200. INSTALLED DOUBLER PER ESO 80559, DATED 5-17-96. (M)