N281AS
Ea Vision EA J100 FAA →
registration
earlier registrations
2 past records
- 1991
service difficulty reports
24 reports
- 1 Apr 2003
Battery Pack, inoperative
DURING A GROUND INSPECTION IN DFW, THE EMERGENCY LIGHTS IN THE AFT SECTION OF THE CABIN WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE…
- 7 Jul 2002
Bulb, burned out
DURING A GROUND INSPECTION IN DFW, THE LEFT UPPER EXTERNAL EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BURNED OUT EMERGENCY LIGHT…
- 4 Jul 2002
Light, inoperative
DURING GROUND INSPECTION IN ATL, THE RIGHT UPPER EXTERNAL EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE INOPERATIVE EXTERNAL EMERGENCY…
- 15 Jun 2002
Lamp, inoperative
DURING GROUND INSPECTION, THE FORWARD MOST OVERWING EMERGENCY LIGHT ON THE RIGHT HAND SIDE OF THE FUSELAGE WAS INOPERATIVE. MAINTENANCE REMOVE AND REPLACED…
- 12 Feb 2002
Attach Fitting, corroded
DURING C-CHECK INSPECTION IN BNA, CORROSION WAS FOUND ON THE REAR FUSELAGE AT THE VERTICAL STABILIZER ATTACH POINTS. MAINTENANCE WILL REPAIR CORROSION AND…
- 12 Feb 2002
Attach Fitting, corroded
DURNG C-CHECK INSPECTION IN BNA, CORROSION WAS FOUND ON THE REAR FUSELAGE AT THE VERTICAL STABILIZER ATTACH POINTS. MAINTENANCE WILL REPAIR CORROSION AND…
- 6 Feb 2002
Stringer, corroded
DURING C-CHECK INSPECTION IN BNA, THE STRINGER 19 (P/N 120-05744-013) LEFT WAS FOUND TO BE CORRODED BETWEEN FRAMES 13A AND 17. CORROSION WAS ALSO FOUND ON…
- 6 Feb 2002
Strap, corroded
DURING C-CHECK INSPECTION IN BNA, THE LEFT BUTT STRAP WAS CORRODED BETWEEN FRAMES 13 AND 14. MAINTENANCE REMOVED AND REPLACED THE CORRODED BUTT STRAP IAW…
- 6 Feb 2002
Strap, corroded
DURING C-CHECK INSPECTION IN BNA, THE LEFT BUTT STRAP BETWEEN FRAMES 21 AND 26 WAS FOUND CORRODED. MAINTENANCE REMOVED AND REPLACED THE CORRODED BUTT STRAP…
- 6 Feb 2002
Crossbeam, corroded
DURING C-CHECK INSPECTION IN BNA, ALL CROSSBEAMS AT FRAME 16 WERE FOUND CORRODED. THE LEFT INBOARD AND RIGHT OUTBOARD CROSSBEAMS WERE FOUND TO BE OUT OF…
- 6 Feb 2002
Sill, corroded
DURING C-CHECK INSPECTION IN BNA, THE RIGHT FLOOR SILL PLATE WAS CORRODED BETWEEN FRAMES 21 AND 26. MAINTENANCE REMOVED AND REPLACED THE CORRODED SILL PLATE…
- 6 Feb 2002
Crossbeam, corroded
DURING C-CHECK INSPECTION IN BNA, THE RIGHT OUTBOARD CROSSBEAM AT FRAME 36 WAS FOUND CORRODED BEYOND LIMITS. MAINTENANCE REMOVED AND REPLACED THR RIGHT…
- 6 Feb 2002
Crossbeam, corroded
DURING C-CHECK INSPECTION IN BNA, THE LEFT INBOARD AND RIGHT OUTBOARD CROSSBEAMS AT FRAME 16 WERE CORRODED. MAINTENANCE REMOVED AND REPLACED BOTH THE LEFT…
- 6 Feb 2002
Strap, corroded
DURING C-CHECK INSPECTION IN BNA, THE LEFT BUTT STRAP WAS CORRODED BETWEEN FRAMES 14 AND 21. MAINTENANCE REMOVED AND REPLACED THE CORRODED BUTT STRAP IAW SRM…
- 6 Feb 2002
Seat Track, corroded
DURING C-CHECK INSPECTION IN BNA, THE LEFT FLOOR SEAT TRACK, MID SECTION, WAS FOUND CORRODED BETWEEN FRAMES 22 AND 32. CORROSION WAS ALSO FOUND ON THE LEFT…
- 6 Feb 2002
Seat Track, corroded
DURING C-CHECK INSPECTION IN BNA, THE RIGHT FLOOR SEAT TRACK WAS FOUND CORRODED ON THE FORWARD SECTION BETWEEN FRAMES 15 AND 22 AND 31. MAINTENANCE FABRICATED…
- 6 Feb 2002
Sill, corroded
DURING C-CHECK INSPECTION IN BNA, THE RIGHT FLOOR SILL PLATE WAS FOUND CORRODED BETWEEN FRAMES 13 AND 21. MAINTENANCE REMOVED AND REPLACED THE CORRODED SILL…
- 13 Jan 2002
Fuse, loose
DURING A HANGAR INSPECTION IN TXK, THE AFT EMERGENCY TRACK LIGHTING WAS FOUND TO BE INOPERATIVE. MAINTENANCE REINSERTED A LOOSE FUSE INTO THE BAYONET…
- 13 Jan 2002
Battery Pack, discharged
FLT 4903 - DURING GROUND INSPECTION IN DFW, THE EMERGENCY LIGHTS AT EXIT ROW 5 WERE FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE EMERGENCY BATTERY PACK AT…
- 28 Nov 2001
Spar Cap, cracked
DURING SCHEDULED MAINTENANCE IN MCN, A CRACK WAS FOUND ON THE RIGHT SIDE LOWER SPAR CAP. MAINTENANCE REPAIRED THE CRACKED SPAR CAP IAW ASA EO 120-57-0117. THE…
- 12 May 1999
Valve, inoperative
AFTER ENGINE START RIGHT PACK FAIL LIGHT ILLUMINATED ADN CABIN FILLED WITH SMOKE. DETERMINED RIGHT PACK TO BE PROBLEM. MOVED TO DEFER LOG PER MEL 21-50-1.…
- 5 May 1999
Duct, cracked
ON CLIMB-OUT FROM XNA-DFW, THE RIGHT DUCT LEAK WARNING LIGHT ILLUMINATED FOLLOWED BY THE LEFT DUCT LEAK WARNING LIGHT. THE CREW SMELLED SMOKE BUT DID NOT…
- 29 Oct 1998
Angle, cracked
AFT FUSELAGE-TO-FIN CONNECTING ANGLE AT THE BASE OF THE VERTICAL STABILIZER AT FS 16128.0, TWO CRACKS .25 INCH LONG TRAVELING FORWARD FROM TWO FASTENERS. THIS…
- 17 Mar 1997
Frame, corroded
DURING SCHEDULED MAINTENANCE, FOUND CORROSION ON FRAME 21 BETWEEN STRINGERS 20 LEFT AND 18 LEFT. REPAIRS MADE IAW THE SRM AND EO 120-53-0056. RII WAS…