service difficulty reports
44 reports
- 3 Jun 2016
Switch, out of adjust
MAIN CABIN DOOR SHOWS OPEN ON THE MFD. ADJUSTED FWD LOCK BOX SWITCH ON MED IAW AMM 52-12-09. OPS CHECK GOOD.
- 25 May 2016
Spring, damaged
F/A ADVISES STAIRS SLAM FLAT WHEN RAISING MCD. R & R SPRINGS ON TOP OF MCD IAW AMM 52-10-07. OPS CHECK GOOD.
- 29 Oct 2015
Handle, unsecure
THE MAIN ENTRY DOOR HANDLE WAS FOUND NOT SECURE. MAINTENANCE SECURED THE HANDLE IAW AMM 52-11-06 AND ALL OPS CHECKS WERE GOOD.
- 19 Feb 2015
Floor Support, corroded
DURING INSPECTION, THE RT OMEGA BEAM AT FRAME 20 WAS FOUND TO BE CORRODED. THE BEAM WAS REPAIRED IAW ETD 2015-145-016197.
- 15 Feb 2015
Floor Support, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE LT OMEGA BEAM INBD FLOORBOARD FLANGE AT FRAME 25. THE FLANGE WAS REPAIRED IAW SRM 51-40-024.
- 14 Feb 2015
Shear Tie, cracked
DURING INSPECTION, THE RT SHEAR CLIP AT FRAME 80 AND STRINGERS 5R-7R WAS FOUND TO BE CRACKED. THE SHEAR CLIP WAS REPLACED IAW SRM 51-40-02.
- 14 Feb 2015
Shear Tie, cracked
DURING INSPECTION, THE APU FIREWALL SHEAR CLIP WAS FOUND TO BE CRACKED AT FRAME 80 AND STRINGERS 8L-9L. THE SHEAR CLIP WAS REPLACED IAW SRM 51-40-02.
- 13 Feb 2015
Floor Support, corroded
DURING INSPECTION, THE CENTER OMEGA BEAM WAS FOUND TO BE CORRODED FROM FRAME 19 TO FRAME 22. THE BEAM WAS REPLACED IAW SRM 51-40-02.
- 12 Feb 2015
Floor Support, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE LT INBD OMEGA BEAM FLOOR FLANGE. THE FLANGE WAS REPLACED IAW SRM 53-00-10.
- 12 Feb 2015
Door Frame, corroded
DURING INSPECITON, CORROSION WAS FOUND ON THE LOWER SIDE OF THE SERVICE DOOR BOTTOM FRAME. THE FRAME WAS REPAIRED IAW ETD 2015-145-016097.
- 11 Feb 2015
Floor Support, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE REPAIR ANGLE AT THE LT OMEGA BEAM AND FRAME 20. THE ANGLE WAS REPAIRED IAW SRM 53-21-10.
- 11 Feb 2015
Threshold, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE REPAIR DOUBLER ON THE CENTER SERVICE DOOR THRESHOLD SILL. THE THRESHOLD WAS REPLACED IAW SRM 51-40-02.
- 11 Feb 2015
Structure, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE RT OTBD SILL AT FRAME 18 THROUGH 20. THE SILL WAS REPLACED IAW SRM 51-40-02.
- 10 Feb 2015
Frame, misinstalled
DURING INSPECTION, THE WORKING RIVETS ON FRAME 79 BETWEEN STRINGERS 4R AND 6R WERE REPLACED IAW ETD 2015-145-017668.
- 29 Dec 2014
Switch, faulty
THE CREW REPORTED THAT THEY RECEIVED A BLEED 2 VLV CLOSED MSG IN FLIGHT. THE CREW DIVERTED THE ACFT & LANDED WITHOUT INCIDENT. REPLACED THE BLEED SYS 2…
- 28 Jun 2013
Battery, inoperative
DURING INSPECTION, THE MAIN ENTRY DOOR EMERGENCY EXIT SIGN WAS FOUND NOT TO ILLUMINATE. MX REPLACED THE EMERGENCY LIGHT INVERTER BATTERY NR 1 AFTER WHICH ALL…
- 20 May 2013
Pressure Switch, malfunctioned
CREW REPORTED THAT DURING CLIMBOUT THEY RECEIVED A YAW DAMPNER FAIL MESSAGE FOLLOWED BY A RUDDER SYSTEM ONE AND TWO INOPERATIVE MESSAGE. THE CREW FOLLOWED THE…
- 20 May 2013
Relay, failed
CREW REPORTED THAT DURING CLIMBOUT THEY RECEIVED A YAW DAMPNER FAIL MESSAGE FOLLOWED BY A RUDDER SYSTEM ONE AND TWO INOPERATIVE MESSAGE. THE CREW FOLLOWED THE…
- 20 May 2013
Relay, failed
CREW REPORTED THAT DURING CLIMBOUT THEY RECEIVED A YAW DAMPNER FAIL MESSAGE FOLLOWED BY A RUDDER SYSTEM ONE AND TWO INOPERATIVE MESSAGE. THE CREW FOLLOWED THE…
- 21 Mar 2013
Fitting, cracked
DURING INSPECTION, A CRACKED SHEAR CLIP WAS FOUND AT FRAME 38 FROM STRINGERS 21L TO 21R. THE SHEAR CLIP WAS REPLACED IN ACCORDANCE WITH SRM 51-40-02.
- 18 Mar 2013
Fitting, cracked
DURING INSPECTION, A CRACK WAS FOUND ON THE SHEAR CLIP AT FRAME 68 BETWEEN STRINGERS 6L AND 7L. THE SHEAR CLIP WAS REPLACED IN ACCORDANCE WITH 53-31-04.
- 16 Mar 2013
Skin, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE SKIN BETWEEN FRAMES 37 AND 38 AND STRINGERS 21R AND 21L. THE SKIN WAS REPAIRED IN ACCORDANCE WITH SRM 53-23-01.
- 16 Mar 2013
Skin, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE SKIN BETWEEN FRAMES 38 AND 39 AND STRINGERS 21R AND 21L. THE SKIN WAS REPAIRED IN ACCORDANCE WITH SRM 53-23-01.
- 28 Jan 2013
Light, damaged
DURING INSPECTION, THE EMERGENCY LIGHTING STRIP THAT IS FARTHEST AFT WAS FOUND TO HAVE A BROKEN LEAD. THE EMERGENCY FLOOR LIGHT STRIP WAS REPLACED.…
- 29 Mar 2012
Hinge, cracked
DURING INSPECTION, THE LEFT AILERON DAMPER HINGE WAS FOUND TO BE CRACKED. THE LEFT AILERON DAMPER HINGE WAS REPLACED IAW SRM 51-40-08 AND 51-40-02.
- 1 Mar 2012
Acm, failed
CREW REPORTED THAT THERE WAS SMOKE IN THE CABIN AND COCKPIT DURING TAKEOFF. THE CREW ABORTED TAKEOFF AND RETURNED TO THE GATE WITHOUT INCIDENT. MAINTENANCE…
- 24 Oct 2011
Inverter, inoperative
DURING INSPECTION, THE EMERGENCY EXIT SIGN ABOVE THE SERVICE DOOR WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHT INVERTER ABOVE THE…
- 28 Jun 2011
Relay, burned
CREW REPORTED THAT DURING FLIGHT RECEIVED A PITOT 3 INOPERATIVE MESSAGE ON THE EICAS FOLLOWED SHORTLY BY AN UNUSUAL ODOR IN THE FLIGHT DECK. THE CREW DIVERTED…
- 27 May 2011
Frame, corroded
DURING INSPECTION, CORROSION WAS FOUND ON FRAME 65, BETWEEN STRINGERS 15L AND 17L. THREE AREAS WERE FOUND WITH THE DEEPEST DAMAGE BEING 0.022" DEEP. THE…
- 27 May 2011
Skin, damaged
DURING INSPECTION, A PREVIOUS BLEND ON THE RIGHT CENTER FUSELAGE SKIN, SECTION I BETWEEN FRAME 16-17 AND STRINGER 19R-20R, WAS FOUND TO BE OUT OF LIMITS. THE…
- 21 May 2011
Skin, dented
DURING INSPECTION THE LOWER CONTROL SURFACE OF THE LEFT ELEVATOR WAS FOUND TO BE DENTED APPROXIMATELY AT YH-1280.00. THE DENT WAS REPAIRED IN ACCORDANCE WITH…
- 20 May 2011
Beam, corroded
DURING INSPECTION CORROSION WAS FOUND ON THE CARGO FLOOR STRUCTURE LOWER BEAM. THE CARGO FLOOR STRUCTURE LOWER BEAM WAS REPLACED; THE NEW PART WAS INSTALLED…
- 6 Sep 2009
Uplock Switch, faulty
FLIGHT 3075, LGA TO RIC. ON TAKEOFF THE CREW REPORTED THAT THE NOSE LANDING GEAR WOULD NOT RETRACT. THE NOSE GEAR INDICATION SHOWED YELLOW CROSS HATCHES AND A…
- 28 Jun 2009
Controller, inoperative
THE ACFT HAD THE AUTO PRESSURIZATION MODE DEFERRED WHEN IT DEPARTED. DURING CLIMB-OUT, WHILE CLIMBING THROUGH 9,000 FT THE CABIN ALTITUDE INDICATED 8,500 FT.…
- 19 May 2009
Inverter, inoperative
DURING INSPECTION THE EMERGENCY FLOOR LIGHTS NR 4, 6, 7, 8 WERE FOUND INOP. THE NR 4 FLOOR PROXIMITY LIGHT STRIP AND NR 4 INVERTER WERE REPLACED AND THE…
- 21 Jan 2009
Proximity Sensor, faulty
FLIGHT 3008, CMH TO LGA - DURING INITIAL CLIMB-OUT AFTER GEAR RETRACTION, THE CREW RECEIVED A LG AIR/GND FAIL MESSAGE ON EICAS, AND WITHIN 1 MINUTE A ENG 1-2…
- 19 Oct 2008
Inverter, inoperative
FLIGHT 3084, CMH TO DCA. DURING INSPECTION THE EMERGENCY EXIT SIDEWALL LIGHT AT SEATS 12 D&F WAS INOP. MAINTENANCE FOUND THE NR 4 INVERTER INOP AND WAS…
- 12 May 2006
Carbon Seal, defective
NORMAL FLIGHT UNTIL CLIMBING THROUGH FL300, NOTICED OIL PRESSURE FOR NR 2 ENGINE WAS IN THE AMBER RANGE ON THE EICAS. CHECKED QUANTITY OF OIL ON NR 2 ENGINE,…
- 5 Nov 2005
Wire, broken
AFT STRIP EMERGENCY FLOOR LIGHTING HAS BROKEN WIRES. REPLACED AFT EMERGENCY LIGHTING STRIP IAW MM 33-26-06. OPS TEST GOOD.
- 9 Aug 2005
Radio, inoperative
FLIGHT 3143 - GSP-LGA - DURING DESCENT, AN ODOR SIMILAR TO ELECTRICAL BURNING WAS NOTICED FOLLOWED BY COM 1 FAILING. REMOVED AND REPLACED THE NR 1 INTEGRATED…
- 12 Jul 2005
Engine, unserviceable
AFTER STARTING DESCENT OUT OF 16,000 FT, HEAT-TYPE ODOR NOTED SHORTLY AFTER MAKING INITIAL POWER REDUCTION. ODOR SUBSIDED AND ATTRIBUTED TO OCCASIONAL PACK…
- 13 Apr 2005
Engine, failed
DURING LATE STAGES OF CLIMB, AT APPROX 24500 FT., NOTICED A SPIKE IN NR 2 ITT OF 911 C. FOR 1 SEC. REDUCED THRUST ON NR 2, ITT RETURNED TO GREEN RANGE.…
- 9 Oct 2004
Engine, leaking
DURING FLIGHT 3089 FROM CVG TO PHL, DURING TAKEOFF ROLL AT AROUND 85 KNOTS SMOKE BEGAN TO ACCUMULATE IN THE CABIN ALONG WITH A BURNING SMELL. THE TAKEOFF WAS…
- 6 Oct 2004
Carbon Seal, leaking
FLIGHT 3115 FROM ROC TO DCA - WHEN TAKEOFF POWER WAS ADDED THE FLIGHT DECK AND CABIN INSTANTLY FILLED UP WITH SMOKE. THE TAKEOFF WAS ABORTED AND THE PLANE WAS…