N279US
Dji AGRAS T40 FAA →
registration
earlier registrations
1 past record
- 1975
service difficulty reports
121 reports
- 12 Jul 2007
Light, inoperative
NO FLIGHT: THE COCKPIT DOOR EMERGENCY EXIT LIGHT WAS FOUND INOPERATIVE. REMOVED AND REPLACED EMERGENCY COCKPIT LIGHT. OPS CHECK NORMAL. AIRCRAFT WAS RETURNED…
- 24 Oct 2006
Accessory Unit, intermittent
FLIGHT 714 - FWA-MIA - DURING APPROACH UPON GEAR EXTENSION THE FLIGHT CREW OBSERVED THREE GREEN AND THREE RED LIGHTS ON THE LANDING GEAR POSITION INDICATOR.…
- 20 Oct 2006
Indication Sys, malfunctioned
FLIGHT 714 - FWA-MIA - DURING APPROACH UPON GEAR EXTENSION THE FLIGHT CREW OBSERVED THREE GREEN AND THREE RED LIGHTS ON THE LANDING GEAR POSITION INDICATOR.…
- 23 May 2006
Indicator, fluctuates
DURING APPROACH TO LANDING, THE IB FLAPS LOCKED OUT AT 2 DEGREES ASYMMETRICAL. THE FLIGHT CREW DECLARED AN EMERGENCY AND CONTINUED WITH THE LANDING APPROACH.…
- 14 Dec 2005
Pin, missing
EXCESSIVE NOSE WHEEL SHIMMY ON LANDING. THE AIRCRAFT WAS TOWED OFF THE RUNWAY. INSPECTION REVEALED THAT THE NOSE GEAR TORQUE LINK QUICK DISCONNECT WAS…
- 12 Feb 2005
Light, intermittent
DURING MAINTENANCE, THE CREW ENTRY DOOR EMERGENCY EXIT LIGHT WAS FOUND INTERMITTENT. REMOVED AND REPLACED EMERGENCY EXIT LIGHT. OPS CHECK GOOD. AIRCRAFT WAS…
- 7 Dec 2004
Clamp, broken
DURING CLIMB, NR 2 ENGINE FIRE WARNING AFTER TAKEOFF. SHUT DOWN NR 2 ENGINE. RETURNED TO AIRPORT. DECLARED EMERGENCY. LANDING WAS MADE WITHOUT INCIDENT. FOUND…
- 17 Jul 2004
Light, inoperative
L1 EMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED EMERGENCY EXIT ILGHT. OPERATION CHECK GOOD. AIRCRAFT RETURNED TO SERVICE. (M)
- 23 Jun 2004
Engine, malfunctioned
SHUTDOWN NR 3 DUE TO HIGH OIL PRESSURE AND RISING OIL TEMP. OIL PRESSURE WAS 53 PSI, OIL TEMP WAS 130 UNTIL POWER REDUCED, THEN OIL TEMP SPIKED OFF SCALE.…
- 19 Jun 2004
Engine, malfunctioned
FLT 2878 - DURING CLIMB, SFO-FWA - SHUTDOWN NR 3 DUE TO HIGH OIL PRESSURE AND RISING OIL TEMP. OIL PRESSURE WAS 53 PSI, OIL TEMP WAS 130 UNTIL POWER REDUCED,…
- 16 Jun 2004
Indicator, inoperative
ON CLIMB-OUT INBOARD FLAPS WOULD NOT RETRACT PAS 2 DEGREES. CREW RETURNED TO FWA WHERE A LANDING WAS MADE WITHOUT INCIDENT, LANDED AT 167600 LBS. REMOVED AND…
- 1 Apr 2004
Skin Panel, missing
ON POST FLIGHT INSPECTION FOUND RT OB AILERON DAMAGE AT IB LOWER SURFACE EDGE IB PANEL MISSING FROM AILERON. AIRCRAFT LANDED WITHOUT INCIDENT. INSTALLED…
- 18 Mar 2004
Fire Loop, shorted
FLT 602 - TOL-FWA - DURING CRUISE, NR 3 ENGINE FIRE PROTECTION GROUND FAULT LIGHT ILLUMINATED. FOUND SAFETY WIRE GROUNDING ON LOOP, REPOSTIIONED WIRE. NR 3…
- 25 Feb 2004
Fire Loop, out of adjust
FLT 875 - FWA-LAX - DURING PREFLIGHT, ENGINE NR 3 FIRE PROTECTION GROUND FAULT LIGHT REMAINS ILLUMINATED. ADJUSTED NR 3 ENGINE FIRE LOOP. CLOSED NR 3 COWL. NR…
- 24 Feb 2004
Fire Loop, malfunctioned
FLT 875 - FWA-LAX - DURING PREFLIGHT, ENGINE NR 3 FIRE PROTECTION GROUND FAULT LIGHT REMAINS ILLUMINATED. (M)
- 30 Oct 2003
Brake Assy, separated
DURING TAXI TO DEPARTURE THE CAPTAIN NOTICED THAT THE LEFT BRAKES WERE DRAGGING. THE AIRCRAFT TAXIED BACK TO THE RAMP. THE NR 2 BRAKE DISK WAS FOUND SEPARATED…
- 5 Feb 2003
Light, inoperative
DURING ROUTINE MAINTENANCE AT FWA, IT WAS DISCOVERED THAT THE COCKPIT EMERGENCY EXIT LIGHT AND FORWARD ENTRY EXIT LIGHT WERE DIM. REMOVED AND REPLACED…
- 19 Sep 2002
Rib, cracked
DURING A LTC INSPECTION, IT WAS DISCOVERED THAT THE RIB CHORD AT FUSELAGE BS 760.95 LEFT WAS CRACKED AT THE FIRST TWO FORWARD HOLES. ACCOMPLISHED REPAIR IAW…
- 19 Sep 2002
Torque Box, cracked
DURING A LTC INSPECTION, IT WAS DISCOVERED THAT THE VENTRAL STAIRS RIGHT LOWER TORQUE BOX HAS A CRACKED REPAIR CHANNEL AT BS 1263. ACCOMPLISHED REPAIR IAW…
- 19 Sep 2002
Seat Track, cracked
DURING A LTC INSPECTION, IT WAS DISCOVERED THAT THE SEAT TRACK WAS CRACKED AT BS 720D, RBL 45.5. ACCOMPLISHED REPAIR IAW BOEING 727 SRM 53-10-5, FIGURE 1. THE…
- 19 Sep 2002
Floorbeam, corroded
DURING A LTC INSPECTION, IT WAS DISCOVERED THAT A FLOORBEAM AT BS 783, LBL 45.5 HAS CORROSION AT UPPER T-CAP. ACCOMPLISHED REPAIR IAW BOEING 727 SRM 53-10-8,…
- 19 Sep 2002
Beam, cracked
DURING A LTC INSPECTION, IT WAS DISCOVERED THAT THE AFT PRESSURE BULKHEAD VERTICAL BEAM AT BS 1183, WL 240, RBL 36 IS CRACKED AT THE INBOARD CHORD.…
- 19 Sep 2002
Frame, cracked
DURING A LTC INSPECTION, IT WAS DISCOVERED THAT A FRAME AT BS 344, STRINGER S2L WAS CRACKED. ACCOMPLISHED REPAIR IAW BOEING 727 SRM 53-10-2, FIGURE 3 AND…
- 19 Sep 2002
Seat Track, corroded
DURING A LTC INSPECTION, IT WAS DISCOVERED THAT THE SEAT TRACK AT BS 520, RBL 45.5 IS CORRODED. ACCOMPLISHED REPAIR IAW BOEING 727 SRM 53-10-5, FIGURE 1. THE…
- 19 Sep 2002
Skin, cracked
DURING A LTC INSPECTION, IT WAS DISCOVERED THAT THE MAIN CARGO DOOR INNER SKIN IS CRACKED AROUND NR 3 LATCH HOOK ASSEMBLY FROM AFT CENTER ATTACH BOLT.…
- 19 Sep 2002
Frame, dented
DURING A LTC INSPECTION, IT WAS DISCOVERED THAT THE FRAME AT BS 380 WAS DENTED AT STRINGER S5L. ACCOMPLISHED REPAIR IAW BOEING 727 SRM 53-10-4, FIGURE 2. THIS…
- 19 Sep 2002
Floorbeam, damaged
DURING A LTC INSPECTION, IT WAS DISCOVERED THAT THE FLOORBEAM AT BS 560, LBL 3 HAVE NUMEROUS HOLES THROUGH THE UPPER FLANGE AND RADIUS. ACCOMPLISHED A REPAIR…
- 19 Sep 2002
Frame, dented
DURING A LTC INSPECTION, IT WAS DISCOVERED THE THE FUSELAGE FRAME AT BS 400, STRINGER S6R WAS DENTED. ACCOMPLISHED REPAIR IAW BOEING 727 SRM 53-10-4, FIGURE…
- 19 Sep 2002
Skin, dented
DURING A LTC INSPECTION, IT WAS DISCOVERED THAT THE RIGHT WING OUTBOARD AILERON TAB HAS A SHARP DENT. REMOVED AND REPLACED THE RIGHT OUTBOARD AILERON TAB IAW…
- 19 Sep 2002
Frame, dented
DURING A LTC INSPECTION, IT WAS DISCOVERED THAT THE FRAME AT BS 540, STRINGER S9R WAS DENTED. ACCOMPLISHED REPAIR IAW BOEING 727 SRM 53-10-4, FIGURE 1. THE…
- 19 Sep 2002
Frame, dented
DURING A LTC INSPECTION, IT WAS DISCOVERED THAT A PREVIOUS REPAIR TO A FRAME AT BS 540, STRINGER S17R HAD BEEN DENTED. ACCOMPLISHED REPAIR TO FRAME IAW 727…
- 19 Sep 2002
Frame, dented
DURING LTC INSPECTION, IT WAS DISCOVERED THAT THE FRAME AT BS 560, STRINGER S7R IS DENTED. ACCOMPLISHED REPAIR IAW BOEING 727 SRM 53-10-4, FIGURE 2. THE…
- 19 Sep 2002
Frame, dented
DURING A LTC INSPECTION, IT WAS DISCOVERED THAT THE PREVIOUS REPAIR AT FRAME BS 600, STRINGER S17R. ACCOMPLISHED REPAIR IAW BOEING 727 SRM 53-10-4, FIGURE 2.…
- 19 Sep 2002
Stringer, cracked
DURING A LTC INSPECTION, IT WAS DISCOVERED THAT STRINGER S15R WAS CRACKED AT BS 730. ACCOMPLISHED REPAIR IAW BOEING 727 SRM 53-10-3, FIGURE 5. THE AIRCRAFT…
- 19 Sep 2002
Stringer, cracked
DURING A LTC INSPECTION, IT WAS DISCOVERED THAT STRINGER S15L WAS CRACKED AT BS 730. ACCOMPLISHED REPAIR IAW BOEING 727 SRM 53-10-3, FIGURE 5. THE AIRCRAFT…
- 19 Sep 2002
Seat Track, corroded
DURING A LTC INSPECTION, IT WAS DISCOVERED THAT THE SEAT TRACK AT BS 520, RBL 25 WAS CORRODED OUT OF LIMITS. ACCOMPLISHED REPAIR IAW BOEING 727 SRM 51-30-5,…
- 19 Sep 2002
Stiffener, cracked
DURING A LTC INSPECTION, IN WAS DISCOVERED THAT THE LEFT WING LEADING EDGE AT WS 62.4 HAS A BOTTOM STIFFENER CRACKED. ACCOMPLISHED REPAIR IAW BOEING 727 SRM…
- 21 Mar 2002
Light, inoperative
DURING ROUTINE MAINTENANCE, IT WAS DISCOVERED THAT THE COCKPIT EMERGENCY EXIT LIGHT WOULD NOT ILLUMINATE. REMOVED AND REPLACED THE EMERGENCY EXIT LIGHT…
- 2 Mar 2001
Warning Light, activated
FLT 723 - ROC-TOL, LOSER AFT BODY OVERHEAT MOMENTARY ILLUMINATION. ISOLATED BY LOWER AFT BODY OVERHEAT ILLUMINATION CHECKLIST. COULD NOT GET LIGHT TO…
- 10 Jan 2001
Accessory Unit, malfunctioned
FLT 708 - OKC-PHX - DURING APPROACH TO PHX, THE CREW NOTED ON GEAR EXTENSION THREE RED LIGHTS AND THREE GREEN LIGHTS ILLUMINATED. THE LANDING GEAR WAS…
- 4 Jan 2001
Socket, corroded
DURING NON-ROUTINE MAINTENANCE, IT WAS DISCOVERED THAT THE L1 DOOR EMERGENCY EXIT LIGHT WAS INOPERATIVE. CLEANED CORROSION FROM LIGHT SOCKET PINS AND CLEANED…
- 27 Nov 2000
Connector, dirty
FLT 728 - BOS-TOL - ON APPROACH TO TOL, WITH THE GEAR HANDLE DOWN, THE AIRCRAFT INDICATED THE RED NOSE GEAR LIGHT AN NO GEAR DOWN AND LOCKED LIGHT. THE…
- 11 Aug 2000
Shear Tie, corroded
DISCREPANCY: NO FLIGHT: FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY. FOUND SHEAR TIE CORRODED AT BS 950B FRAME, OUTBOARD OF…
- 7 Aug 2000
Seat Track, gouged
FOUND DUIRNG ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY, MAIN CABIN SEAT TRACK HAS GOUGES ON TOP FLANGE AT BS 526, LBL 5, RLB 5 REF TIMCO…
- 7 Aug 2000
Seat Track, gouged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY, MAIN CABIN SEAT TRACK HAS GOUGES ON TOP FLANGE AT BS 436 LBL 5 RBL 5 REF TIMCO…
- 7 Aug 2000
Frame, dented
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY, STATION 660 FRAME DENTED BETWEEN STINGER 16R AND 17R. REF TIMCO NON-ROUTINE CARD…
- 7 Aug 2000
Frame, cracked
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY, STATION 720 LEFT FRAME CRACKED AND DENTED BETWEEN STRINGER 16L AND 17L, REF…
- 7 Aug 2000
Frame, damaged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY, STATION 600 FRAME HAS TWO OPEN HOLES NEXT TO EACH OTHER AT STRINGER 16R REF…
- 7 Aug 2000
Frame, dented
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY, STATION 600 FRAME DENTED BETWEEN STRINGER 16R AND STRINGER 17R REF TIMCO…
- 7 Aug 2000
Frame, cracked
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY, STATION 640 FRAME HAS CRACK COMING OUT OF GILL LINER ATTACH HOLE AT STRINGER 16R…
- 7 Aug 2000
Frame, cracked
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY, STATION 640 FRAME HAS DENT BETWEEN STRINGER 16R AND STRINGER 17R REF TIMCO…
- 7 Aug 2000
Stringer, corroded
FOUND DURING SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY, STRINGER SPLICE CORRODED BETWEEN FUSELAGE AND SPLICE AT BS 1010 FRAME STRINGER 29L.…
- 7 Aug 2000
Frame, dented
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY, FOUND FRAME DENTED BELOW STRINGER S16L AT BS 1166, REF N/R NR 20388. REPAIRED…
- 7 Aug 2000
Frame, damaged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC, MAINTENANCE FACILITY, DAMAGED FRAME AT STATION 560 BETWEEN STRINGER 8R AND 9R REF TIMCO NON ROUTINE…
- 7 Aug 2000
Seat Track, gouged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY, MAIN CABIN SEAT TRACK HAS GOUGES ON TOP FLANGE AT BS 436 RBL 45 AND RBL 46 REF…
- 7 Aug 2000
Seat Track, gouged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY, MAIN CABIN SEAT TRACK HAS GOUGES ON TOP FLANGE AT BS 436, RBL 24 AND RBL 25 REF…
- 7 Aug 2000
Frame, damaged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY, BS FRAME 380 UPPER AFT LIP AT BOTTOM SIDE HAS STIFFENING STRAP SEPARATING FROM…
- 7 Aug 2000
Stringer, corroded
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY, STRINGER 28R AT STATION 485 HAS CORROSION INSIDE STRINGER REF TIMCO NON-ROUTINE…
- 7 Aug 2000
Frame, damaged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY, FRAME HAS DOUBLE DRILED HOLE AT STATION 1130 LBL 65, 4 INCHES ABOVE FLOOR REF…
- 7 Aug 2000
Frame, dented
FOUND DURNIG ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY, STATION 440 LEFT FRAME FOUND DENTED FIVE INCHES ABOVE THE FLOOR, REF NR 20807.…
- 7 Aug 2000
Frame, damaged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY, STATION 1030 LBL 43 FLOORBEAM UPPER CHORD HAS A DOUBLE DRILL HOLE, REF TIMCO…
- 7 Aug 2000
Frame, misdrilled
FOUND DURING ROUTINE SCHEDULED MAINTENANCE , FRAME DOUBLER DRILLED AT STATION 520 AT STRINGER 16R REF NON ROUTINE CARD NR 20392. REPAIRED FRAME IAW B727 SRM…
- 7 Aug 2000
Frame, damaged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, FRAME DOUBLE DRILLED AT STATION 540 AT STRINGER 16R REF NON ROUTINE CARD NR 20393. REPAIRED FRAME IAW B727 SRM…
- 7 Aug 2000
Frame, cracked
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, FOUND CRACK IN MLG WELL AT BS 940, LBL 50 REF N/R NR 20014, 20692, AND 20816. REPAIRED IAW BOEING DRAWING 65-89360…
- 7 Aug 2000
Frame, dented
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, FRAME DENT AT STATION 580 BETWEEN STRINGER 16R AND STRINGER 17R REF NON ROUTINE CARD NR 20499. REMOVED OLD REPAIR…
- 7 Aug 2000
Frame, misdrilled
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, STATION 580 HAS DOUBLE DRILLED HOLES AT STRINGER 16R REF NON ROUTINE CARD NR 20502. REMOVED DAMAGE, FABRICATED…
- 7 Aug 2000
Frame, misdrilled
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, STATION 620 FRAME HAS TWO OPEN HOLES NEXT TO EACH OTHER AT STRINGER 16R REF NON ROUTINE CARD NR 20506. REMOVED…
- 7 Aug 2000
Frame, dented
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, FRAME DENT STATION 520 BETWEEN STRINGER 16R AND STRINGER 17R REF NON ROUTINE CARD NR 20514. REMOVED DAMAGE,…
- 7 Aug 2000
Frame, dented
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, FRAME DENTED STATION 540 BETWEEN STRINGER 6R AND STRINGER 7R REF NON ROUTINE CARD NR 20516. REPAIRED FRAME IAW…
- 7 Aug 2000
Skin, dented
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, SKIN WAS FOUND DENTED AT BS 420, STRINGER 20R, REF N/R 20305. INSTALLED REPAIR SHEAR TIE AND FILLER AT BS 440…
- 7 Aug 2000
Shear Tie, damaged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, AT BS 1010 BETWEEN STRINGER 30L AND STRINGER 29L, FOUND A SHEAR TIE DRILLED INTO FROM A PREVIOUS REPAIR, AND SIX…
- 7 Aug 2000
Skin, corroded
FOUND DURNG ROUTINE SCHEDULED MAINTENANCE, AT BS 485, STRINGER 28R, THE INTERIOR SKIN WAS FOUND TO BE CORRODED, REF NR 20564. REPAIRED FUSELAGE SKIN IAW B727…
- 7 Aug 2000
Frame, gouged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, AT BS 720E, THE FRAME WAS FOUND TO BE GOUGED BETWEEN STRINGER 16L AND STRINGER 17L, REF NR 20614. REPAIRED…
- 7 Aug 2000
Floorbeam, corroded
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, MAIN CABIN FLOORBEAM HAS CORROSION AROUND CLIP NUT HOLES AT BS 312, LBL 3 AND LBL 10, REF NR 20622. REPAIRED…
- 7 Aug 2000
Frame, misdrilled
FOUND DURING ROUTINE MAINTENANCE, FOUND FRAME AT BS 783 NEAR STRINGER S17R HAD A HOLE DRILLED IN THE RADIUS, REF NR 20639. REPAIRED FRAME IAW B727 SRM 51-40-3…
- 7 Aug 2000
Stringer Clip, damaged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, STRINGER CLIP AT BS 700, STRINGER 2R FOUND TO BE DAMAGED, REF NR 20750. REMOVED AND REPLACED STRINGER CLIP IAW…
- 7 Aug 2000
Stringer Clip, damaged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, STRINGER CLIP AT BS 700, STRINGER 2L FOUND TO BE DAMAGED, REF NR 20785. REMOVED AND REPLACED STRINGER CLIP IAW…
- 7 Aug 2000
Stringer Clip, damaged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, STRINGER CLIP AT BS 700, STRINGER 3L FOUND TO BE DAMAGED, REF NR 20786. REMOVED AND REPLACED STRINGER CLIP IAW…
- 7 Aug 2000
Stringer Clip, damaged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, STRINGER CLIP AT BS 460, STRINGER 3L FOUND TO BE DAMAGED, REF NR 20789. REMOVED AND REPLACED STRINGER CLIP IAW…
- 7 Aug 2000
Stringer Clip, damaged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, STRINGER CLIP AT BS 480, STRINGER 3L FOUND TO BE DAMAGED, REF NR 20790. REMOVED AND REPLACED STRINGER CLIP IAW…
- 7 Aug 2000
Stringer Clip, damaged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, STRINGER CLIP AT BS 460, STRINGER 7L FOUND TO BE DAMAGED, REF NR 20791. REMOVED AND REPLACED STRINGER CLIP IAW…
- 7 Aug 2000
Stringer Clip, damaged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, STRINGER CLIP AT BS 460, STRINGER 6L FOUND TO BE DAMAGED, REF NR 20792. REMOVED AND REPLACED STRINGER CLIP IAW…
- 7 Aug 2000
Frame, damaged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, FOUND FRAME DENTED AT BS 1166, STRINGER 17R, REF NR 20808. REPAIRED FRAME IAW B727 SRM 51-40-3, FIGURE 1. THE…
- 7 Aug 2000
Intercostal, cracked
FOUND DURING ROUTINE SCHEDULED MAINTENANCE, FOUND MAIN CABIN FLOORBEAM INTERCOSTAL CRACKED AT BS 311, LBL 32.5, REF NR 20810. REMOVED AND REPLACED CRACKED…
- 7 Aug 2000
Lamp, inoperative
FOUND DURING SCHEDULED MAINTENANCE AT TIMCO/OSC, EMERGENCY EXIT LIGHT AT L-1 DOOR HAS ONE LAMP INOPERATIVE. CLEANED LAMP HOLDER CONTACT AND SECURED LAMP.…
- 7 Aug 2000
Frame, damaged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC, FOUND FRAME DENT BETWEEN STRINGER 5R AND STRINGER 6R AT BS 380, REF 20822. REMOVED DAMAGED AREA,…
- 7 Aug 2000
Fitting, cracked
DISCREPANCY: NO FLIGHT: FOUND DURING ROUTINE SCHEDULED MAINTENANCE . FOUND BS 370 STRINGER S-5R FITTING CRACKED. REF 20823. CORRECTIVE ACTION: REMOVED AND…
- 7 Aug 2000
Angle, cracked
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC, FOUND FRAME ATTACH ANGLE CRACKED BS 620, AFT SIDE OF CUSP, REF NR 20854. REMOVED AND REPLACED CRACKED…
- 7 Aug 2000
Clip, damaged
FOUND DURNIG ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC, FOUND STRINGER CLIP GROUND OUT OF LIMITS AT BS 700, S3L, REF NR 20788. REMOVED AND REPLACED CLIP IAW…
- 7 Aug 2000
Rib, damaged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC, VERTICAL STAB CLOSURE REQUIRES SPOT FACING IAW S/B 727-55-071, REF NR 20880. REWORKED STAB CLOSURE…
- 7 Aug 2000
Stringer Clip, damaged
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC, IMPROPER BLEND OUT ON STRINGER CLIP AT BS 680, S7L, REF NR 20619. REMOVED AND REPLACED STRINGER CLIP…
- 8 Jul 2000
Frame, dented
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT TIMCO/OSC MAINTENANCE FACILITY, FRAME DENT AT STATION 500 BETWEEN STRINGER 16R AND STRINGER 17R REF TIMCO NON…
- 18 Jan 2000
Light, inoperative
DURING ROUTINE MAINTENANCE AT MHR IT WAS DISCOVERED THAT THE EMERGENCY EXIT LIGHT OVER THE MAIN ENTRANCE DOOR WAS INOPERATIVE. REMOVED AND REPLACED THE…
- 28 Sep 1999
Smoke Detector, inoperative
DURING ROUTINE MAINTENANCE AT TOL IT WAS DISCOVERED, THAT THE NR 2, NR 4, NR 5, AND NR 6 SMOKE DETECTORS WOULD NOT TEST. REMOVED AND REPLACED THE NR 2, NR 4,…
- 21 Jun 1999
Skin, dented
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT AIA/OSC MAINTENANCE FACILITY. FOUND DENT ON RIGHT WING NR 4 MIDFLAP LEADING EDGE. INSTALLED PERMANENT REPAIR AT…
- 21 Jun 1999
Skin, dented
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT AIA/OSC MAINTENANCE FACILITY. FOUND DENT ON MAIN CARGO DOOR DOUBLER AT STATION 568 AND 648. INSTALLED PERMANENT…
- 21 Jun 1999
Frame, cracked
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT AIA/OSC MAINTENANCE FACILITY. FOUND FRAME CRACKED BS 600 AT FASTENER HOLE BETWEEN STRINGER 25L AND 26L.…
- 21 Jun 1999
Skin, cracked
FOUND DURING ROUTINE SCHEDULED MAINTENANCE AT AIA/OSC MAINTENANCE FACILITY. FOUND SKIN DAMAGED BELOW C-3 DOOR FROM BS 1090 TO 1140. INSTALLED PERMANENT REPAIR…
- 22 Apr 1999
Indication, malfunctioned
ON CLIMB-OUT OF TOL, THE RIGHT GEAR DOOR LIGHT CAME ON IN FORWARD FE'S FORWARD PANEL. SELECTED GEAR TO UP POSITION. THE LIGHT WENT OUT AND STAYED OUT WHEN…
- 9 Feb 1999
Detector, dirty
EN ROUTE FROM MHR-TOL, THE CARGO SMOKE DETECTION CARGO LIGHT ILLUMINATED. THE AIRCRAFT DECLARED AN EMERGENCY AND DIVERTED TO SLC. THE AIRCRAFT LANDED WITHOUT…
- 16 Nov 1998
Power Supply, inoperative
EN ROUTE TO TOL TO PHX, THE AIRCRAFT HAD THE FIRE WARNING BELL CAME ON WITHOUT ANY WARNING LIGHT INDICATION AS TO WHICH ENGINE OR ANY OTHER INDICATIONS DURING…
- 11 Nov 1998
Switch, malfunctioned
EN ROUTE FROM TOL TO SLC, THE AIRCRAFT HAD THE FIRE WARNING BELL COME ON WITH ANY WARNING LIGHT INDICATION AS TO WHICH ENGINE OR ANY OTHER INDICATIONS. THE…
- 10 Nov 1998
Fire Loop, malfunctioned
EN ROUTE FROM MCI TO PHX THE AIRCRAFT HAD THE FIRE WARNING BELL COME ON WITH OUT ANY WARNING LIGHT INDICATION AS TO WHICH ENGINE OR ANY OTHER INDICATIONS. THE…
- 8 Oct 1998
Battery Pack, discharged
EMERGENCY EXIT LIGHT IN COCKPIT DOES NOT ILLUMINATE. REMOVED AND REPLACED TWO BATTERIES. OPERATIONAL CHECK OK. AIRCRAFT WAS THEN RETURNED TO SERVICE. (M)
- 6 Jun 1998
Gearbox, leak
PRECAUTIONARY SHUTDOWN NR 3 ENG. ENG LOW OIL PRESS LIGHT ILLUMINATED WHILE LANDING, OIL QTY GAUGE READS ZERO. ENG OIL PRESS LOW. COWLING OPENED AND MAJOR OIL…
- 2 Feb 1998
Wire, broken
FLT 738, ON APPROACH INTO MHR GOT AN UNSAFE NOSE GEAR INDICATION WHEN THE GEAR WAS EXTENDED. CYCLED SEVERAL TIMES AND NO CHANGE. AN UNEVENTFUL LANDING WAS…
- 13 Jan 1998
Overheat Loop, failed
FLT 739 - LEFT OAK AND EXPERIENCED A LOWER AFT BODY OVERHEAT LIGHT ON. RAN CHECKLIST. LIGHT DID NOT GO OUT. RETURNED TO OAK AFTER DECLARING AND EMERGENCY. AN…
- 5 Aug 1997
Pin, broken
DURING C-CHECK, REMOVAL OF HORIZONTAL STABILIZER REVEALED THAT RT STABILIZER ATTACHMENT PIN WAS SEVERELY RUSTED AND BROKEN IN HALF. ALSO, FOUND FAIL-SAFE BOLT…
- 2 Apr 1997
Smoke Detector, failed
FLT 725 - BRO-TOL - THE PILOT REPORTED THE FOLLOWING ON LOG PAGE 718-14. FAULTY CARGO SMOKE INDICATION. SMOKE DETECTOR SYSTEM OPS CHECKS NORMAL ON GROUND. (M)
- 26 Mar 1997
Smoke Light, illuminated
FLT 725 - BRO-TOL - DURING FLT, THE PILOT REPORTED, THE FOLLOWING ON LOG PAGE 718-03, ON DESCENT INTO TOL, SMOKE LIGHT CAME ON. WE VERIFIED NO SMOKE AND…
- 12 Dec 1996
Smoke Detector, malfunctioned
STL/SJC - FLT 712 - DURING DESCENT INTO SJC; CARGO COMPARTMENT SMOKE DETECTOR ILLUMINATED. VISUALLY VERIFIED NO SMOKE PRESENT IN CARGO CABIN. LIGHT WENT OUT…
- 12 Dec 1996
Smoke Det Amp, failed
CARGO SMOKE LIGHT ILLUMINATED IN-FLIGHT. CHANGED SMOKE DETECTOR CONTROL AMP AND NRS 1, 2, 3, 4, AND 6 SMOKE DETECTORS. (X)
- 11 Dec 1996
Smoke Detector, intermittent
SJC/TOL - FLT 711 - CARGO COMPARTMENT SMOKE DETECTOR ILLUMINATED. MAINTENANCE REPLACED NR 5 SMOKE DETECTOR. SYSTEM OPS CK NORMAL. (X)
- 6 Dec 1996
Smoke Light, illuminated
CARGO SMOKE LIGHT ILLUMINATED DURING DESCENT, VERIFIED NO SMOKE OR FIRE AS PER EMERGENCY CHECK LIST. COULD NOT DUPLICATE. OPERATES NORMALLY ON GROUND IAW B…
- 23 Nov 1996
Smoke Detector, malfunctioned
FLT NR 279 - BRO-DFW - DURING CRUISE THE CARGO COMPARTMENT SMOKE DETECTOR ILLUMINATED. VISUALLY VERIFIED NO SMOKE PRESENT IN CARGO CABIN. MAINTENANCE COULD…
- 21 Nov 1996
Smoke Det, malfunctioned
FLT 711 - SJC-TOL - DURING CRUISE, IN LAST HOUR OF FLT CARGO COMPARTMENT SMOKE DETECTOR ILLUMINATED. VISUALL VERIFIED NO SMOKE PRESENT IN CARGO. AGAIN DURING…
- 28 Oct 1996
Smoke Light, malfunctioned
FLT NR 725 - IAH-TOL - PRIOR TO DESCENT INTO TOL, MAIN CARGO CABIN SMOKE DETECTOR LIGHT CAME ON. CHECKED CABIN NO SMOKE NOTED. MAINTENANCE CHECKED SMOKE…
- 4 Jun 1996
Smoke Detector, illuminated
IAH/TOL - FLT 725 - DURING DESCENT INTO TOL, MAIN CARGO CABIN SMOKE DETECTOR LIGHT CAME ON. CHECKED CABIN, NO SMOKE NOTED. MAINTENANCE CHECKED SYSTEM, NO…
- 19 Mar 1996
Smoke Light, illuminated
FLT NR 711 - SJC-TOL - WHILE IN CRUISE TO TOL, THE FLIGHT CREW NOTICED THE CARGO COMPARTMENT SMOKE DETECTION LIGHT ILLUMINATED, NO EVIDENCE OF SMOKE WAS…
- 13 Sep 1995
Trunnion, corroded
DURING PERIODIC CHECK, FOUND CORROSION ON THE UPPER RIGHT NOSE GEAR TRUNNION FITTING. REPLACED FITTING (P/N 65-17676-40), PER SRM 51-10-01 PG 4 PARA 4.
- 13 Sep 1995
Trunnion Fitting, corroded
DURING PERIODIC CHECK, FOUND CORROSION ON THE NOSE LANDING GEAR UPPER RIGHT TRUNNION FITTING. REPLACED FITTING (P/N 65-17676-40), PER SRM 51-10-01 PG 4 PARA 4.