N276X
1994 Sikorsky S-76C standard FAA →
earlier registrations
1 past record
- 1994
service difficulty reports
36 reports
- 1 Mar 2009
Engine, warning light
CRUISING AT 2500 FEET THE NR 1 ENGINE CHIP LIGHT ILLUMINATED AND APPROX 5 SECONDS THEREAFTER THE ENGINE SHUTDOWN.
- 31 May 2006
Starter Gen, noisy
NOISE WAS HEARD FROM ENGINE COMPARTMENT, SEVERAL SECONDS LATER, NR 2 GENERATOR LIGHT CAME ON, NR 2 ENGINE N2 NEEDLES WENT TO ZERO ON BOTH SIDES. PERFORMED…
- 14 Jun 2005
Hmu, malfunctioned
MASTER CAUTION 5-PACK ILLUMINATED. CHECKED CAUTION PANEL AND NR 2 LOW FUEL PRESSURE SEGMENT WAS DIMLY ILLUMINATED. MASTER CAUTION WOULD NOT RESET. SUSEQUENTLY…
- 12 Feb 2003
Chip Detector, shorted
CHIP PLUG INTERMITTENTLY SHORTS INTERNALLY. SCRAPPED.
- 21 Dec 1999
H.E. Generator, inoperative
H.E. UNIT INOPERATIVE. REPLACED UNIT.
- 15 Dec 1999
Actuator, intermittent
ACTUATOR WORKS INTERMITTENLY AND STICKS. REPLACED UNIT.
- 5 Nov 1999
Engine, making metal
ENGINE ASSEMBLY MAKING METAL. REPLACED WITH ANOTHER ENGINE.
- 13 Dec 1995
Catch Assembly, cracked
AFT COWL CATCH CRACKED . REPLACED UNIT.
- 13 Dec 1995
Blower, inoperative
BLOWER INOPERATIVE . REPLACED UNIT.
- 13 Dec 1995
Nose Wheel, corrosion
CORROSION IN HUB CENTER AREA. REPLACED UNIT.
- 13 Dec 1995
Oil Cap, defective
R & R CAP. REPLACED UNIT
- 13 Dec 1995
Catch Assembly, cracked
ENGINE COWL CATCH CRACKED. REPLACED UNIT
- 13 Dec 1995
Valve, defective
BLEED SOV LEAKING. REPLACED UNIT
- 8 Dec 1995
Valve, sticks
VALVE STICKS OPEN . REPLACED UNIT
- 30 Nov 1995
Bearing, worn
WORN BEARINGS S/NOS: 4483, 4754, 4749, 4686 REPLACED UNIT WITH S/NOS: 37674, 37540, 37624, 37581
- 27 Nov 1995
Intake Screen, cracked
FOUND INLET SCREEN CRACKED IN CENTER AREA WHICH CONTRIBUTED TO ENGINE FOD ON ENGINE S/N: 15094. REPLACED UNIT
- 27 Nov 1995
Engine Assy, fod
COMPRESSOR FOD. REPLACED UNIT
- 21 Nov 1995
Detector, defective
FLAME DETECTOR WOULD NOT TEST, THIS DETECTOR ORIGINALLY INSTALLED IN N476X. REPLACED UNIT
- 21 Nov 1995
Solenoid, defective
ENGINE NOT STARTING. REPLACED UNIT
- 21 Nov 1995
Drain Valve, defective
ENGINE NOT STARTING. REPLACED START DRAIN VALVE UNIT.
- 21 Nov 1995
Switch, sticking
SWITCH STICKING. REPLACED UNIT
- 20 Nov 1995
Tip Cap, separated
TRAILING EDGE SEPERATED. REPLACED UNIT
- 20 Nov 1995
Tip Cap, separated
TRAILING EDGE SEPERATED REPLACED UNIT
- 17 Nov 1995
Intake Screen, cracked
INTAKE SCREEN CRACKED. REPLACED UNIT
- 14 Nov 1995
Blower, oil leaks
OIL LEAKS AT IMPELLER SHAFT. REPLACED UNIT
- 12 Oct 1995
Upper Housing, corroded
WHILE CHANGING OIL COOLER DRIVE QUILL SEAL , FOUND CORROSION ON QUILL MOUNT PAD , TREATED AND APPLIED MASTING UNTIL PERMANENT REPAIR CAN BE MADE.
- 12 Oct 1995
Rate Gyro, inoperative
RATE GYRO INOPERATIVE, REPLACED UNIT.
- 12 Oct 1995
Starter, failed
STARTER WON'T ENERGIZE, REPLACED UNIT.
- 10 Oct 1995
Oil Pump, defective
LOW OIL PRESSURE AT MODULE 5 TEST POINT, ALSO OIL LEAKS FROM OIL TANK TO ENGINE GEARBOX. REPLACE UNIT
- 9 Oct 1995
Tip Cap, seoaration
TRAILING EDGE SEPERATION. REPLACE UNIT
- 22 Aug 1995
Uniball Bearing, corroded
UNIBALL BEARING CORROSION. REPLACE UNIT
- 12 Jul 1995
Valve Assy, failed
ENGINE WILL NOT SHUTOFF WITH THROTTLE. NEW A/C PURCHASED FROM SIKORKSY
- 12 Jul 1995
Actuator, inoperative
ACTUATOR INOPERATIVE ORDER REPLACEMENT PART
- 12 Jul 1995
Indicator, inoperative
SECTIONS OF LED LITES INOPERATIVE DURING ALL SETTINGS REPLACE UNIT
- 12 Jul 1995
Shuttle Valve, leaking
SHUTTLE VALVE LEAKING REPLACED WITH NEW STYLE P/N (98-71-2) AS PER CSL 76-A0-95-005
- 26 Apr 1995
Transmitter, defective
FLUX VALVE PRECESS 30 AND WILL NOT SLAVE RMI. ORDER NEW