N264SK
2000 Embraer EMB-145LR standard FAA →
earlier registrations
1 past record
- 2000
service difficulty reports
13 reports
- 20 Sep 2017
Spacer, loose
WHEN INSPECTING THE AILERON CABLES THE INSPECTOR FOUND THAT THE SPACER LISTED BELOW HAD GAP IN IT CAUSING THE BOLT TO WOBBLE IN THE HOLE AND THE BELLCRANK TO…
- 1 May 2009
Fan, disconnected
FLIGHT 5880, IAH TO BTR - DURING CLIMB-OUT AT APPROXIMATELY FL030, THE FLIGHT CREW RECEIVED A NR 1 AHRS OVERHEAT MESSAGE. THE QRH WAS FOLLOWED AND IT WAS…
- 29 Apr 2009
Unknown, unknown
FLIGHT 5844, CLE TO PVD - DURING CLIMB WHEN THE CREW CHECKED PRESSURIZATION, THE CPAM INDICATED ALL ZEROS. THERE WAS NO EICAS MESSAGE PRESENT. THE CREW…
- 5 Jul 2008
Sensor, open
FLIGHT 5881, DCA TO CLE. WHILE CLIMBING THROUGH 17,000 FT A FUEL 1 LOW LEVEL MESSAGE APPEARED ON EICAS. THE LT TANK INDICATED ZERO WITH THE RT TANK INDICATING…
- 28 Jun 2008
Inverter, inoperative
MAINTENANCE FOUND THE FLOOR BOARD EMERGENCY LIGHTS INOP BETWEEN ROW 3 AND 12. THE EMERGENCY LIGHT INVERTERS NR 2 AND NR 5 WERE REPLACED AND THE EMERGENCY…
- 15 Jun 2008
Fcu, false indication
FLIGHT 5855, ORF TO RIC. DURING CLIMB THE CREW RECEIVED A FUEL IMBALANCE AND FUEL LOW LEVEL MESSAGE ON EICAS FOR THE LT FUEL TANK. THE FLIGHT DIVERTED AND…
- 15 Jun 2008
Inverter, defective
THE LT EXTERNAL EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE DURING OVERNIGHT MAINTENANCE. MAINTENANCE FOUND THE NR 2, 5, AND 6 INVERTERS INOPERATIVE. AFTER…
- 30 Jul 2007
Control Valve, inoperative
ON CLIMB-OUT FROM CLE WITH PACK 2 DEFERRED WERE UNABLE TO MAINTAIN COMFORTABLE CABIN/COCKPIT TEMPERATURE. TEMPERATURE REACHED 38 DEGREES C IN COCKPIT. WE…
- 4 Mar 2006
Bulb, burned out
FIRST PROXIMITY STRIP IS DAMAGED. REMOVED AND REPLACED FLOOR PROXIMITY STRIP IAW EMB 145 MM 33-50-12.
- 2 Oct 2005
Sign, inoperative
FORWARD EMERGENCY EXIT LOCATOR SIGN IN CEILING INOPERATIVE. REMOVED AND REPLACED EMERGENCY EXIT LOCATOR SIGN IAW EMB MM 33-50-15. OPS CHECK GOOD.
- 30 Jan 2005
Static Inverter, unserviceable
MAIN DOOR EMERGENCY EXIT SIGN IS INOP. FOUND THE STATIC INVERTER FAULTY FOR THE MAIN DOOR EMERGENCY EXIT SIGN. REMOVED AND REPLACED THE STATIC INVERTER IAW…
- 4 Nov 2004
Lamp, burned out
GALLEY OVERHEAD EMERGENCY LIGHT INOP. REMOVED AND REPLACED GALLEY OVERHEAD EMERGENCY EXIT LIGHT PER EMB 145 MM 33-50-09. RIGHT EMERGENCY OVERWING EXTERNAL…
- 3 Sep 2004
Bulb, inoperative
LEFT HAND FORWARD EMERGENCY EXIT LIGHT IS INOP. REMOVED AND REPLACED LIGHT BULB IAW EMB 145 MM 33-50-10. OPS CHECK GOOD.