N248AA
Anduril Industries INC CPJ-100 FAA →
registration
earlier registrations
1 past record
- 1984
service difficulty reports
33 reports
- 20 Jul 2009
Power Supply, discharged
OUTSIDE FUSELAGE EMERGENCY LIGHTS INOPERATIVE. REPLACED POWER SUPPLY FOR EXTERIOR EMERGENCY OVERWING LIGHTS.
- 20 Jul 2009
Battery Pack, discharged
FLOOR PROXIMITY LIGHTS FAILED WORK CARD 5403. REPLACED ABS-4 BATTERY PACK.
- 14 Dec 2008
Tee Fitting, cracked
LOWER FORWARD TEE FITTING CRACKED. REMOVED AND REPLACED CRACKED TEE FITTING.
- 13 Sep 2007
Pump, failed
ORD INFLIGHT T1493/13SEP - AFT CENTER TANK BOOST PUMP CIRCUIT BREAKER POPPED. RETURNED TO ORD AND LANDED WITHOUT INCIDENT. REPLACED AFT CENTER TANK BOOST…
- 5 Sep 2007
Bulb, inoperative
LGA - EMERGENCY LIGHT ON ANNUNCIATOR PANEL INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT ON ANNUNCIATOR PANEL. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 23 Jan 2007
Bulb, burned out
LGA - EMERGENCY LIGHT AT AFT SERVICE DOOR INOPERATIVE. RELAMPED EMERGENCY LIGHT AT AFT SERVICE DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 15 Nov 2005
Manifold, inoperative
LAX - LEFT ENGINE LOOP-A LIGHT FOLLOWED BY LEFT ENGINE FIRE WARNING DURING CLIMBOUT AT APPROXIMATELY 6000 FEET. THROTTLES TO IDLE AND LIGHTS AND WARNING WENT…
- 12 May 2003
Wire, inoperative
DURING OVERNIGHT MAINTENANCE, CEILING AISLE EMERGENCY EXIT LIGHTS FROM ROWS 8 THROUGHT 11 INOPERATIVE. INSTALLED NEW EMERGENCY EXIT LIGHT BATTERY GROUND WIRE.…
- 7 May 2003
Battery, inoperative
AUS - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTS AT SEAT 9D INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT BATTERY. SYSTEM GROUND CHECKED NORMAL…
- 3 Dec 2002
Shear Tie, cracked
TUL - FOUND SHEAR TIE CRACKED AT FASTENER HOLE, RIGHT SIDE OF L2R. REPLACED WITH SERVICEABLE SHEAR TIE PER SRM 51-30. (M)
- 3 Dec 2002
Shear Tie, cracked
TUL - FOUND SHEAR TIE CRACKED STATION 1437, RIGHT SIDE OF LONGERON 1R AFT SIDE. REMOVED AND REPLACED SHEAR TIE PER SRM 51-30. (M)
- 25 Nov 2002
Skin, cracked
TUL - FOUND CRACK IN FUSELAGE SKIN .375 INCH LONGERON FROM RIVET HEAD AT STATION 1380 L13R. STOP DRILLED CRACK, DYE CHECKED AND INSTALLED DOUBLER PER SRM…
- 22 Nov 2002
Frame, damaged
TUL - FOUND DAMAGE ON FORMER AT STATION 522 BETWEEN L20R AND L21R. INSTALLED FORMER REPAIR SPLICE PER SRM 53-03-00 FIG 3. (M)
- 21 Nov 2002
Skin, cracked
TUL - FOUND CRACKED .375 INCH IN FUSELAGE SKIN FROM RIVET HEAD STATION 1380 L14L. INSTALLED DOUBLER PER AARD 53-30-00-02. (M)
- 20 Nov 2002
Seat Track, corroded
TUL - FOUND CORROSION ON BOTTOM SIDE OF CLIP NUT TABS, BEYOND MANUAL LIMITS. SPLICE IN NEW SECTION OF NR 2 SEAT TRACK PER SRM 53-05. (M)
- 19 Nov 2002
Skin, corroded
TUL - FOUND CORROSION IN FUSELAGE SKIN INBOARD AREA OF FORWARD LAVATORY DRAIN ACCESS AREA BEYOND MANUAL LIMITS. INSTALLED DOUBLER PER ESO 80559, DATED…
- 19 Nov 2002
Web, damaged
TUL - FOUND STATION 636 FORWARD SIDE OF DOOR JAMB DAMAGE TO STRUCTURE FROM TO LONGERON SCREW BEING INSTALLED IN FLOORBOARD. INSTALLATION OF DOUBLER PER AARD…
- 19 Nov 2002
Seat Track, corroded
TUL - FOUND CORROSION BEYOND MANUAL LIMITS. SPLICE NEW SECTION OF SEAT TRACK NR 6 SRM PER SRM 53-05. (M)
- 15 Nov 2002
Beltframe, cracked
TUL - FOUND TWO CRACKS ON BELL FRAME STATION 1174, L6L. INSTALLED DOUBLER, STOP DRILLED CRACKS PER 53-10-00-30. (M)
- 15 Nov 2002
Longeron, cracked
TUL - FOUND LONGERON 17L CRACKED WHERE IT INTERSECTS FRAME 237. INSTALLED LONGERON SPLICE PER SRM 53-02-00 FIG 18. (M)
- 15 Nov 2002
Longeron, cracked
TUL - FOUND LONGERON 17L CRACKED AT STATION 332. INSTALLED LONGERON SPLICE PER SRM 53-02-00 FIG 18. (M)
- 14 Nov 2002
Web, torn
TUL - FOUND RIGHT CUSP TORN AT STATION 1000. REPLACED CUSP, RIGHT SIDE, STATION 1000 PER SRM 53-01. (M)
- 14 Nov 2002
Web, damaged
TUL - FOUND TWO DAMAGED HOLES IN FORWARD EDGE OF CUSP AT STATION 984. INSTALLED CUSP DOUBLER AT STATION 984 PER SRM 53-01 FIG 4. (M)
- 14 Nov 2002
Longeron, cracked
TUL - FOUND LONGERON 17L IS CRACKED AT STATION 408. CUT OUT DAMAGED SECTION OF LONGERON. INSTALLED LONGERON SPLICE REPAIR PER SRM 53-02-00. (M)
- 12 Nov 2002
Skin, wrinkled
TUL - FOUND 3 INCH WRINKLE ON EXTERNAL SKIN STATION 109, FORWARD OF LONGERON 25R. INSTALLED FILLER A DOUBLER PER SRM 53-01-00 FIG 2 SHEET 3. (M)
- 12 Nov 2002
Beam, corroded
TUL - FOUND CORROSION ON HORIZONTAL AND VERTICAL SURFACES OF MID CARGO DOOR BEAM. REMOVED CORROSION PER SRM 51-10-03. INSTALLED DOUBLER ON DOOR BEAM WHERE…
- 4 Jul 2002
Battery, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, CEILING EMERGENCY EXIT LIGHTS AT ROW 8 THROUGH 11 DIM. RESEATED CEILING EMEREGNCY EXIT LIGHTS BATTERY. SYSTEM GROUND…
- 4 Apr 2002
Seal, missing
AMA- FLT 717 - EN ROUTE DFW-OAK, AT 31,000 FEET FLIGHT ATTENDANTS REPORTED FUMES AND SMOKE IN REAR OF AIRCRAFT. PASSENGER IN SEAT 24B REPORTED TO FLIGHT…
- 25 Oct 2001
Wire, loose
SAN - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT INOPERATIVE. RESECURED EMERGENCY EXIT LIGHT WIRE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 28 May 1999
Connectors, defective
MIA - FLT 1479 - DURING CLIMB-OUT FROM FLL AT APPROX 15,000-18,000 FT, THE MASTER CAUTION AND FIRE DETECTION LIGHTS ILLUMINATED, ALONG WITH LOOP 'B' LIGHT FOR…
- 24 Nov 1997
Conductor, defective
DFW - DURING OVERNIGHT CHECK, EMERGENCY EXIT LIGHTS FOUND INOPERATIVE FROM FIRST CLASS BULKHEAD TO FORWARD OVERWING EXIT. REPLACED FLAT CONDUCTOR AT FIRST…
- 10 Feb 1997
Connector, loose
SFO - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS IN MAIN CABIN FROM PAX SEAT ROW 21 FORWARD INOPERATIVE. RESECURED LOOSE EMERGENCY FLOOR LIGHT STRIP…
- 6 Jul 1996
Fuel Control, malfunctioned
SFO - FLT 1308 - DURING CLIMB-OUT, RIGHT ENGINE SURGED TO 95 PERCENT N1 FOLLOWED BY FLAME OUT. ACCOMPLISHED ENGINE SHUTDOWN PROCEDURES AND AIRCRAFT DIVERTED…