N246AA
1981 Beech B200 standard FAA →
registration
- 1981
aircraft radio
1 past record
earlier registrations
1 past record
- 1984
service difficulty reports
32 reports
- 22 Dec 2008
Strut, discharged
COS - INFLIGHT, CREW REPORTED NOSE LANDING GEAR GRINDING OR SPINNING NOISE ON RETRACTION WITH BURNING RUBBER ODOR NOTED. RETURNED TO COS AND LANDED WITHOUT…
- 11 Nov 2007
Cable, damaged
MCI INFLIGHT T2406 - LANDING GEAR WOULD NOT RETRACT. RETRACT HANDLE WOULD NOT RETURN TO RETRACT POSITION. RETURNED TO MCI AND LANDED WITHOUT INCIDENT.…
- 25 Mar 2007
Battery Pack, inoperative
LGA - OVERHEAD EMERGENCY LIGHTS IN FIRST CLASS INOPERATIVE. REPLACED BATTERY PACK FOR OVERHEAD EMERGENCY LIGHTS IN FIRST CLASS. SYSTEM GROUND CHECKED NORMAL…
- 15 Mar 2007
Battery Pack, inoperative
LGA - EMERGENCY EXIT SIGNS AT OVERWING EXIT INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY EXIT SIGNS AT OVERWING EXIT. SYSTEM GROUND CHECKED NORMAL…
- 21 Feb 2007
Wire Harness, damaged
YUL - EMERGENCY EXIT LIGHT AT SEAT 5EF INOPERATIVE. REPAIRED HARNESS FOR EMERGENCY LIGHT AT SEAT 5EF. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 2 Jan 2007
Wire, disconnected
LGA - EMERGENCY LIGHT AT SEAT 5E INOPERATIVE. FOUND WIRES PULLED FROM CONNECTOR. REPAIRED WIRING FOR EMERGENCY LIGHT AT SEAT 5E. SYSTEM GROUND CHECKED NORMAL…
- 14 Aug 2006
Oil Cap, leaking
ONT - ON TAKEOFF REPORTED SMOKE IN CABIN. RETURNED TO ONT AND LANED WITHOUT INCIDENT. FOUND APU OIL LEAK FROM OIL CAP. REINSTALLED CAP AND COALESCER BAGS ON…
- 27 Mar 2006
Battery Pack, inoperative
ORD - LEFT AND RIGHT HAND EMERGENCY EXIT SIGNS AT AFT ESCAPE HATCHES AND FORWARD ENTRY EMERGENCY LIGHT AT FORWARD GALLEY INOPERATIVE. REPLACED BATTERY PACKS…
- 28 Mar 2003
Terminal, inoperative
ORD - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT CEILING LIGHTS FROM ROW 18-21 INOPERATIVE. SECURED EMERGENCY EXIT CEILING LIGHT TERMINAL AT BATTERY. GROUND…
- 17 May 2002
Wire, loose
DFW - DURING OVERNIGHT MAINTENANCE, TAIL CONE EMERGENCY EXIT LIGHTS DIM. SECURED EMERGENCY EXIT LIGHT WIRE CONNECTION. SYSTEM GROUND CHECKED NORMAL OPERATION.…
- 21 Aug 2001
Battery Pack, discharged
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT PATH LIGHTING AT ROWS 28 THROUGH 31 INOPERATIVE. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL…
- 6 May 2001
Light, defective
DFW - DURING OVERNIGHT MAINTENANCE, SEAT MOUNTED EMERGENCY EXIT LIGHT DIM. REPLACED SEAT MOUNTED EMERGENCY EXIT LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION.…
- 9 Apr 2001
Battery, discharged
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT ASSEMBLY DIM. RE-CHARGED EMERGENCY EXIT LIGHT BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 3 Jun 2000
Wire, broken
DFW - DURING OVERNIGHT MAINTENANCE, COCKPIT AND FORWARD EMERGENCY EXIT LIGHTS INOPERATIVE. REPAIRED EMERGENCY EXIT LIGHT WIRE. (M)
- 10 Nov 1999
Wire, loose
DFW - DURING OVERNIGHT MAINTENANCE, OVERHEAD AISLE EMERGENCY EXIT LIGHTS AT ROWS 17 AND 24 INOPERATIVE. SECURED OVERHEAD AISLE EMERGENCY EXIT LIGHT GROUND…
- 24 Sep 1999
Seat Track, corroded
TUL - NR 3 SEAT TRACK STA 1174 HAS CORROSION. BLENDED CORROSION, INSTALLED PLUG PER SRM 53-05 PART 1 FIG 4A. ALODINED AND PAINTED PER SRM 51-10-1. TST: 45,869…
- 24 Sep 1999
Seat Track, corroded
TUL - FOUND NR 2 SEAT TRACK HAS CORROSION IN CHANNEL. REPAIRED TRACK WITH 3 LIP PLUG REPAIR PER SRM 53-05 PART 1 PAGE 8C SHEET 1 FIG 4A. (M)
- 24 Sep 1999
Seat Track, corroded
TUL - FOUND SEAT TRACK NR 6 HAS CORROSION STATION 792-795. SPLICED SEAT TRACK AT STATION 730 PER SRM 53-05 PART 1 FIG 4F SHEET 2 THROUGH 11 PAGE 10K THROUGH…
- 24 Sep 1999
Seat Track, corroded
TUL - NR 3 SEAT TRACK HAS CORROSION STATION 733. INSTALLED SEAT TRACK PLUG REPAIR PER SRM 53-05 PART 1 FIG 4A. (M)
- 24 Sep 1999
Floorbeam, worn
TUL - FOUND MAIN CABIN FLOORBEAM HAS WORN AREA STATION 655 RIGHT 1 INCH. BLENDED DAMAGE FROM BOTTOM OF FLOORBEAM STATION 655, FABRICATED REPAIR ANGLE AND…
- 24 Sep 1999
Pan, corroded
TUL - EXFOLIATED CORROSION BELOW CABIN FLOOR AT APPROX STATION 182-200, LBL 44-55. NOTE EXFOLIATED CORROSION ABOVE CABIN FLOOR ALSO. REPAIRED CORROSION DAMAGE…
- 22 Sep 1999
Splice, corroded
TUL - CORROSION AROUND HI-LOKS IN LONGERON SPLICE. REMOVED AND REPLACED SPLICE PART MADE IN HOUSE PER AARD INTRO PAGE 8 SPLICE REPLACEMENT PER SRM 53-02. TST:…
- 20 Sep 1999
Longeron, cracked
TUL - FOUND LONGERON 4L CRACKED AT BELLFRAME 160. REPAIRED LONGERON PER SRM 53-02 PAGE 48 FIG 18. (M)
- 20 Sep 1999
Seat Track, corroded
TUL - FOUND NR 3 SEAT TRACK CORRODED AT STATION 794. CUT OUT DAMAGED SEAT TRACK FROM STATION 755 AND 815. INSTALLED NEW SEAT TRACK PER SRM 53-5 FIG 4F-1,…
- 29 Jul 1999
Wire, broken
DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING BETWEEN ROWS 17 AND 27 INOPERATIVE. REPAIRED WIRING TO EMERGENCY EXIT FLOOR PATH LIGHTING…
- 20 Apr 1999
Light, defective
DFW - DURING OVERNIGHT MAINTENANCE CHECK, EMERGENCY EXIT FLOOR PATH LIGHT SRIP AT FORWARD GALLEY INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP…
- 17 Jan 1998
Light, inoperative
DFW - DURING OVERNIGHT CHECK, DISCOVERED FIRST CLASS EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED LIGHT STRIP AT FIRST CLASS EMERGENCY EXIT. SYSTEM GROUND…
- 2 Mar 1997
Wire, broken
DFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS IN MAIN CABIN FROM WING AREA AND AFT INOPERATIVE. REPAIRED SHORTED EMERGENCY FLOOR LIGHT WIRING AT WING…
- 11 Aug 1996
Actuator, defective
SEA - FLT 1554 - AFTER TAKEOFF SEA WHEN LANDING GEAR RETRACTED, NOSE LANDING GEAR INDICATED UNSAFE. RECYCLED LANDING GEAR WITH SAME RESULTS. EXTENDED LANDING…
- 4 May 1996
Sensor, defective
DFW - FLT 296 - AFTER TAKEOFF TUS, WHEN LANDING GEAR RETRACTED, NOSE LANDING GEAR RED LIGHT STAYED ILLUMINATED INITIALLY AND THEN FLICKERED AND FINALLY…
- 2 May 1996
Fan, defective
DFW-DEN - FLT 1295 - DURING CRUISE, ELECTRICAL BURNING ODOR NOTED IN AFT CABIN AREA WITH NO OTHER ABNORMAL INDICATIONS. PRECAUTIONARY TURNED POWER OFF TO REAR…
- 6 Feb 1996
Floor Web, corroded
TULE - FOUND FLOOR WEB CORRODED UNDER THRESHOLD STRIP AT AFT END OF FORWARD GALLEY DOOR OPENING. INSTALLED CUSP DOUBLER AS PER SRM 53-01 FIG 2. (M)