- 15 May 1997
Batt Charger, burned
AN ELECTRICAL ODOR WITH A SLIGHT TRACE OF HAZE WAS NOTICED IN THE CABIN WHILE ON DESCENT INTO CLE. THE GASPER FAN AND GALLEY POWER WAS TURNED OFF AND THE ODOR…
- 4 May 1997
Strut, cracked
A GRINDING SOUND WAS HEARD COMING FROM LANDING GEAR AREA DURING TAXI. MAINTENANCE FOUND THE NR 2 BRAKE ASSEMBLY DAMAGED DUE TO A SHEARED BOLT AND THE LT MLG…
- 13 Jan 1997
Fan, inoperative
THE FLIGHT ATTENDANTS REPORTED, A BURNING ODOR IN CABIN WHILE EN ROUTE. THE SMOKE CHECKLIST PROCEDURE WAS ACCOMPLISHED AND THE ODOR DISSIPATED AFTER THE RT…
- 15 Nov 1996
Relay Module, burnt
SMOKE WITH FUMES WAS OBSERVED COMING FROM ELECTRICAL PANEL BY THE JUMP SEAT ON AIRCRAFT RIGHT ON APPROACH. THE M181 MODULE WAS HOT TO TOUCH, THE MODULE WAS…
- 3 Sep 1996
Drive Mechanism, worn bearing
WHEN FLAPS WERE SELECTED TO 30 DEGREES ON APPROACH, THE AIRCRAFT ROLLED LEFT. THE FLAPS WERE SET TO 25 DEGREES AND THE ROLL STOPPED. THE AIRCRAFT LANDED…
- 29 May 1996
Frame, cracked
INSPECTION FOUND A 3 INCH CRACK IN UPPER FLANGE OF C-1 DOORWAY AFT FRAME. THE CRACKED FRAME WAS REMOVED AND A NEW FRAME SECTION WAS FABRICATED AND INSTALLED…
- 29 May 1996
Angle, corroded
INSPECTION FOUND NOSE WHEEL WELL CEILING SUPPORT I BEAM AND ATTACHING ANGLES CORRODED. THE BEAM AND ANGLES WERE REMOVED. A NEW BEAM AND ANGLES WERE FABRICATED…
- 29 May 1996
Stringer, corroded
INSPECTION FOUND STRINGER CHANNEL CORRODED AT STA 351.2 TO 360, S20L. THE STRINGER CHANNEL WAS REMOVED AND A NEW CHANNEL WAS FABRICATED AND INSTALLED IAW SRM…
- 29 May 1996
Skin, dented
INSPECTION FOUND FUSELAGE SKIN DENTED IN TWO PLACES AT STA 1016, S29R. THE DENTED AREAS WERE CUT OUT, A REPAIR DOUBLER WAS FABRICATED AND INSTALLED IAW SRM…
- 27 May 1996
Skin, corroded
INSPECTION FOUND SKIN CORRODED AT BS 410, STRINGER 18L. THE CORRODED SKIN WAS CUTOUT. A REPAIR DOUBLER AND FILLER WAS FABRICATED AND INSTALLED IAW SRM…
- 27 May 1996
Floorbeam, corroded
INSPECTION FOUND CORROSION ON AFT UPPER FLANGE OF FLOORBEAM AT BS 294.5, RBL 20 TO RBL 40. THE CORRODED SECTION OF FLOORBEAM WAS REMOVED, A NEW SECTION OF…
- 27 May 1996
Skin, creased
INSPECTION FOUND SKIN CREASED FROM BS 228 TO 360, JUST ABOVE STRINGER 19R. THE DAMAGED SKIN WAS CUT OUT, REPAIR DOUBLERS AND FILLERS WERE FABRICATED AND…
- 27 May 1996
Stringer, corroded
INSPECTION FOUND CORROSION OVER AN 18 INCH SECTION OF STRINGER 22R BETWEEN BS 390 AND 410. THE CORRODED SECTION OF STRINGER WAS REMOVED. REPAIR CHANNEL AND…
- 27 May 1996
Stringer, corroded
INSPECTION FOUND A 3 INCH SECTION OF STRINGER 21R CORRODED AT BS 416. THE CORRODED SECTION OF STRINGER WAS REMOVED AND REPAIR CHANNEL AND ANGLES WERE…
- 27 May 1996
Skin, dented
INSPECTION FOUND SKIN DENTED BETWEEN STRINGER 23R AND 24R AT BS 394. THE DAMAGED SECTION OF SKIN WAS CUT OUT, A DOUBLER AND FILLER REPAIR WAS FABRICATED AND…
- 27 May 1996
Skin, dented
INSPECTION FOUND SKIN DENTED BETWEEN STRINGER 23R AND 24R AT BS 394. THE DAMAGED SECTION OF SKIN WAS CUT OUT, A DOUBLER AND FILLER REPAIR WAS FABRICATED AND…
- 24 May 1996
Skin, dented
INSPECTION FOUND FUSELAGE SKIN DENTED AT STA 344 TO 380, STRINGER 20R TO 22R. THE DENTED AREA OF SKIN WAS CUT OUT AND NEW SKIN, FILLER AND DOUBLER WERE…
- 11 Oct 1995
Angle, cracked
GSO - INSPECTION FOUND A 2.5 INCH CRACK IN RADIUS OF RT LOWER FORWARD SHEAR BEAM ATTACH ANGLE AT STA 664. THE CRACKED ANGLE WAS REMOVED AND SHEAR BEAM…
- 4 Oct 1995
Floor Beam, cracked
GSO - INSPECTION FOUND FLOOR BEAM WEB CRACKED AT FIVE EACH LOWER FASTENER HOLES BETWEEN BS 700-BS 717, BBL 0.07. THE COMBINED CRACK LENGTH WAS APPROXIMATELY 5…
- 11 Sep 1995
Skin, corroded
IAH - INSPECTION FOUND A POPPED FASTENER WITH CORROSION IN SKIN AT LAP JOINT FORWARD OF C-1 DOOR THRESHOLD STATION 400. THE CORRODED AREA OF SKIN WAS CUT OUT…