N239NV
Airbus A320-214 FAA →
registration
service difficulty reports
10 reports
- 4 Dec 2025
Battery Pack, faulted
(AIRCRAFT NOT GROUNDED) EPSU BATTERY FAULT. REMOVED AND REPLACED EPSU REF WO537555"
- 8 Aug 2025
Wire, broken
(AIRCRAFT NOT GROUNDED) L1 DOOR WALL MOUNTED EMERGENCY LIGHT INOP. FOUND WIRE TERMINAL BROKEN. RECRIMPED WIRE TERMINAL IAW ESPM 20-48-14-01 B. (B). OPS CHECK…
- 21 Feb 2025
Lubrication Unit, faulted
(AIRCRAFT GROUNDED) (EMERGENCY DECLARED) CLIMBING OUT OF 12000 FEET GOT ADV FOR LOW OIL QTY ENG 1. FOLLOWED BY DROPPING OIL PRESSURE. OIL PRESSURE DROPPED IN…
- 5 Feb 2025
Cover, out of position
(AIRCRAFT NOT GROUNDED) L1 DOOR SLIDE INDICATION NOT SHOWING WITH DOOR CLOSED AND ARMED. / REMOVED L1 DOOR DECORATIVE SLIDE COVER AND INSPECTED SLIDE FLAP AND…
- 2 Feb 2025
Indication Sys, intermittent
(AIRCRAFT NOT GROUNDED) L1 SLIDE INTERMITTENLY INDICATES ARMED ON SD. / PERFORMED TSM 52-11-00-810-806-A FOUND DECORATIVE COVER STRAPS INTERFERING WITH GERT…
- 28 Dec 2023
Unknown, unknown
EMERGENCY LIGHT BATTERY CAPACITY CHECK FAILED AS PER AMM 33-51-00-710-003-A / REMOVED AND REPLACED 11 WL."
- 17 Dec 2023
Girt Bar, unknown
(MAJOR REPAIR) AT R1 FWD GIRT BAR FITTING AREA, FWD OUTBD HOLE FOUND CORRODED / R1 DOOR SILL BEAM FWD GIRT BAR FITTING AREA, FWD OUTBD HOLE PERMANENTLY…
- 10 Dec 2023
Unknown, unknown
(MAJOR REPAIR) AT R1 AFT GIRT BAR FITTING AREA, FWD INBD, AFT INBD AND OUTBD HOLES FOUND CORRODED / R1 DOOR SILL BEAM AFT GIRT BAR FITTING AREA, FWD INBD, AFT…
- 23 Dec 2022
Power Supply, no test
EMERGENCY POWER SUPPLY UNIT OPERATIONAL CHECK FAILED / R/R EMERGENCY POWER SUPPLY UNITS (10WL) (11WL) (12WL) (13WL), OPS CHECK GOOD. IAW AMM 33-51-38 PB 401"
- 29 Jun 2021
Epsu, failed
EMERGENCY BATTERY PACKS 10WL,11WL,12WL AND 13WL FAILED BATTERY TEST. / R&R'D EMERGENCY LIGHT BATTERY PACKS 10WL,11WL,12WL AND 13WL REF AMM 33-51-38 PB-401.…