N236US
Boeing 737-201 FAA →
reservations
earlier registrations
1 past record
service difficulty reports
23 reports
- 11 Feb 2000
Skin, cracked
TPA - FOUND .5 INCH SKIN CRACK, STATION 540, JUST BELOW LAP AND STRINGER 14L SKIN. INSTALLED FILLER AND DOUBLER PER SRM 53-30-3 AND EA 66144. (M)
- 17 Jul 1999
Web, cracked
PIT - DURING RON CHECK, FOUND 6 INCH CRACK AT PRESSURE SIDEWALL WEB, NOSE WHEEL WELL AT BS 259.5, WL 175.6. INSTALLED SHEETMETAL DOUBLERS AND FILLERS PER…
- 17 Jul 1999
Skin, cracked
PIT - DURING RON CHECK, FOUND A .75 INCH CRACK AT STATION 747 STRINGER 18 RT AND A .75 INCH LONG CRACK AT STATION 767 STRINGER 19 RT ON SKIN. INSTALLED…
- 17 Jul 1999
Skin, cracked
PIT - DURING RON CHECK, FOUND .5 INCH LONG CRACK AT STATION 727A STRINGER 18 RT ON SKIN. INSTALLED EXTERNAL DOUBLER PER SRM 53-30-3 FIG 6. (M)
- 14 Jun 1999
Charger, failed
ORD - MAINTENANCE FOUND THE LEFT AND RIGHT FORWARD ENTRY EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE FORWARD BATTERY CHARGER ASSEMBLY.…
- 14 Jan 1999
Skin, cracked
CLT - DURING PCI CHECK VISUAL INSPECTION, FOUND A 1 INCH CRACK ON FUSE SKIN STATION 727 BELOW STRINGER 17R. INSTALLED DOUBLER PER SRM 53-30-3 FIG 1. (M)
- 2 Jul 1998
Seal, out of position
PIT - FLT 856 - AFTER TAKEOFF FROM PIT, AIRCRAFT FAILED TO PRESSURIZE. A LOUD AIR NOISE WAS HEARD COMING FROM DOOR R1. FLIGHT RETURNED TO PIT AND LANDED…
- 21 Jun 1998
Engine, overtemp
PIT - FLT 1894 - AFTER TAKEOFF FROM PIT, THE NR 1 ENGINE ENCOUNTERED HIGH OIL TEMPERATURE. FLT RETURNED TO FIELD AT PIT AND LANDED WITHOUT INCIDENT. NO…
- 10 Feb 1998
Anti-Ice Duct, leaking
TPA - FLT 1874 - THE NR 2 ENGINE OVERHEAT LIGHT ILLUMINATED DURING CLIMB-OUT APPROXIMATELY 25 MILES NORTH OF TPA. CREW FOLLOWED EMERGENCY PROCEDURES FOR…
- 30 Jan 1998
Windshield, defective
ORF - FLT 1279 - CAPT REPORTED VIA ACARS THAT FLIGHT WAS RETURNING TO FIELD AT ORF DUE TO A LOUD AIRLEAK COMING FROM THE F/O'S WINDSHIELD. NOISE WAS TOO LOUD…
- 24 Oct 1997
Skin, cracked
ROA - DURING BX CHECK VISUAL INSPECTION, FOUND 3 INCH SKIN CRACK STATION 950 STRINGER 24L FUSELAGE SKIN. REMOVED CRACK AND INSTALLED DOUBLER, REPAIRED PER SRM…
- 24 Oct 1997
Skin, cracked
ROA - DURNG BX CHECK VISUAL INSPECTION, FOUND 1.125 INCH CRACK AFT ENTRY DOOR SKIN AFT UPPER CORNER. STOP DRILLED CRACK AND INSTALLED DOUBLER, REPAIRED PER…
- 31 Aug 1996
Battery Pack, failed
CLT - MAINTENANCE FOUND BOTH OVERWING EMERGENCY EXIT LIGHTS FLASHING. MAINTENANCE REMOVED AND REPLACD THE BATTERY PACK FOR THE OVERWING EMERGENCY EXIT LIGHTS.…
- 30 Aug 1996
Light Ballast, burned
IAH - FL 1183 - ON DESCENT INTO IAH, CREW DETECTED SMELL OF SMOKE IN THE COCKPIT. WHILE LOOKING FOR THE SOURCE, THE SMOKE ALARM IN THE FORWARD LAV WENT OFF.…
- 22 Aug 1996
Stringer, cracked
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND TWO .25 INCH CRACKS AT FASTENER HOLES STATION 532, STRINGER 15R. REMOVED DAMAGED SECTION OF STRINGER AND…
- 22 Aug 1996
Beam, corroded
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND SEVERAL 1 INCH BY 1 INCH CORRODED AREAS BS 420 TO BS 500, STRINGER 26R BEAM. FABRICATED AND REPLACED WITH NEW…
- 22 Aug 1996
Angle, corrosion
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 40 INCH STATION 277 TO 340 'Z' ANGLE RIGHT SIDE. INSTALLED DOUBLER, REPAIRED PER SRM…
- 22 Aug 1996
Stringer, cracked
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND TWO .25 INCH CRACKS IN FASTENER HOLES FOR STRINGER 15R TO STATION 532. CUT OUT DAMAGED AREA AND FABRICATED AND…
- 22 Aug 1996
Floor Beam, corrosion
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND CORROSION .5 INCH BY 6 INCH AT STATION 947.5 FLOOR BEAM. REPAIRED T-CAP, DOUBLERS AND REPAIR ANGLES. REPAIRED…
- 22 Aug 1996
Stringer, corroded
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 7 INCH CORRODED AREA STRINGER 27L, STATION 967. CUT OUT DAMAGE AND INSTALLED STRINGER SPLICE REPAIR.…
- 22 Aug 1996
Floor Beam, broken
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND UPPER 'T' OF FLOOR BEAM BROKEN INTO STATION 663 BL0. INSTALLED DOUBLER ON T-CAP AND WEB. REPAIRED PER BOEING…
- 22 Aug 1996
Floor Beam, cracked
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND ONE .25 INCH CRACK BS 520 AT RBL 25 CABIN FLOOR BEAM. INSTALLED NEW CHANNELS AND DOUBLERS PER EA 41421. (M)
- 22 Aug 1996
Floor Beam, cracked
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND ONE .25 INCH CRACK BS 520 AT RBL 45 INCH FLOOR BEAM. INSTALLED NEW CHANNEL AND DOUBLERS, REPAIRED PER EA…